BLUE SEA 7700, 7702, 7701, 7703 User guide

Page 1
Marine Electrical Prod
ucts
ML– Series
Remote Battery Switches (with manual control)
PN 7700 / PN 7702
Solenoid Switches (without manual control)
PN 7701 / PN 7703
• Magnetic Latch—draws no current in ON or OFF state, only draws current when changing state of switch
• Silver alloy contacts provide high reliability for switching live loads
• Manual control override knob provides an added level of safety allowing control with or without power, and offering LOCKED OFF capability for servicing (Remote Battery Switch ONLY)
• LED output to remotely indicate switch state
• Tin-plated copper studs for maximum conductivity and corrosion resistance
Label recesses for circuit identication
Specications 12VDC 24VDC
Cranking Rating See table below See table below Intermittent Rating See table below See table below Continuous Rating See table below See table below ML-Coil Function Bi-Stable Bi-Stable Operating Voltage (contacts) 0-64V 0-64V Control Voltage 9-16V DC 18-32V DC Amperage Operating Current 0 mA continuous 0 mA continuous <7A when changing state (20 ms) <4A when changing state (20 ms) Terminal Stud Size 3/8"-16 3/8"-16 Maximum Terminal Stud Torque 140 in-lb (15.8 N•m) 140 in-lb (15.8 N•m) Ring Terminal Size 3/8" (M10) 3/8" (M10) Terminal Ring Diameter Clearance 1.18" (30 mm) 1.18" (30 mm) Live Current Switching 10,000 @ 12V, 300A 10,000 @ 12V, 300A 10,000 @ 24V, 150A 10,000 @ 24V, 150A 2,000 @ 48V, 100A 2,000 @ 48V, 100A Mechanical Switching 100,000 Cycles 100,000 Cycles
RemoteSwitchPN2145
Action Momentary SPDT (ON)-OFF-(ON) Seals Internal & External Gasket Panel Seal Mounting Hole 0.83"x 1.45" (21.08 mm x 36.83 mm) LED Rating 100,000 hours half-life
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, CE marked, Rated IP66
Wire Size and Current Ratings
Wire Size
2/0 AWG (70 mm²) 1,000A 400A 225A
4/0 AWG (120 mm²) 1,100A 400A 300A
2× 4/0 AWG (2x 120 mm²) 1,450A 700A 500A
Cranking
30 sec.
Intermittent
5 min.
Continuous
(UL 1107)
The ML-Series Remote Battery Switch/Solenoid Switch provides high-current carrying and switching under load. The Remote Battery Switch/Solenoid Switch is installed close to the battery banks. A single pole double throw (SPDT) Control Switch Panel, or two momentary push button switches, operate the Remote Battery Switch/Solenoid Switch. Control Switches are installed in a convenient location near other electrical controls or companionway (see Illustrations on reverse).
Overview of Application
The Manual Control Override Knob provides (Remote Battery Switch Only):
• an added level of safety that allows manual ON-OFF control with or without power
• LOCK OFF for servicing the electrical system
Remote Operation. The momentary (SPDT) (ON)-OFF-(ON) Remote Control Contura Switch can
provide cross connect and/or battery isolation. The Control Switch should be mounted in a convenient loca­tion near helm controls to allow for quick access.
To connect battery bank to load, or combine battery banks
To disconnect battery bank from load, or isolate battery banks that are connected
Momentarily depress control switch actuator to “ON”. Remote LED indicates closed connection.*
Momentarily depress control switch actuator to “OFF”.*
Emergency Manual Control Override Operations (Remote Battery Switch Only)
To connect battery bank to load, or combine battery banks
To disconnect battery bank from load, or isolate battery banks that are connected
To prevent remote operation
To secure for servicing
* If the Control Switch is held ON or OFF for 5 seconds, the internal coil protection will engage and the Remote Battery Switch/Solenoid Switch will not respond to further remote input for approximately 10 seconds.
With Override Knob in (REMOTE position), push button until latched (Push to Latch On).
Rotate Override Knob to right to release button from Latch On mode (button pops up). Rotate Override Knob to left (REMOTE position).
Rotate Override Knob to right (LOCK OFF position).
With Override Knob in (LOCK OFF position), pass cable tie through hole.
1
2
Solenoid Switch
PN Termination
7701 Tinned Wires No 12V DC 7703 Tinned Wires No 24V DC
990180170 Rev.006
Manual Control
Control
Circuit
Remote Battery Switch
PN Termination
7700 Tinned Wires Yes 12V DC 7702 Tinned Wires Yes 24V DC
Manual Control
Blue Sea Systems, Inc. 4600 Ryzex Way Bellingham, WA 98226 USA Phone 360.738.8230
www.bluesea.com
Control
Circuit
Page 2
+VDC, 24 HR. (red)
A
B
+VDC, TO CLOSE (brown)
+VDC, TO OPEN (orange)
LED OUTPUT (yellow)
GROUND (black)
START
BATTERY
ENGINE
LED
1
2
3
+8
-7
CONTROL SWITCH
Momentary SPDT
(ON)-OFF-(ON)
2 AMP MIN.
10 AMP MIN.
CAUTION
These instructions are intended to provide assistance with the installation of this product, and are not a substitute for a more comprehensive understanding of electrical systems. We strongly recommend that a competent electrical professional perform the installation of this product.
The illustrated wiring diagram represents a common installation and is not meant to be a guide for wiring
a specic vessel. The wiring diagram shows a single battery bank installation.
Disconnect all negative battery connections before beginning the installation.
All unused control wires should be carefully insulated from each other and from accidental contact using heat shrink tubing or electrical tape. External contact or shorting between control wires can lead to malfunction.
Installation Instructions
Mounting
Install as close as possible to battery bank. To avoid corrosion to connecting wires and terminals, mount in a dry and protected location. Avoid mounting directly above vented lead acid batteries so that the Remote Battery Switch/Solenoid Switch is not exposed to corrosive gasses expelled from the batteries.
High Current Primary Circuit Connections (stud terminals A and B)
For help selecting the appropriate wire size and circuit protection rating, go to www.bluesea.com and click the Circuit Wizard quick link.
NOTE: Stud terminals A and B are interchangeable. The load can be connected to A or B; the battery bank can be connected to A or B.
To connect high current circuit wires:
1. Connect the battery bank to one of the stud terminals marked A or B.
2. Connect the load to the other stud terminal marked B or A.
3. Torque the high current terminal stud nuts to 140 in-lbs (15.8 N•m) maximum.
NOTE: If switching an inverter, windlass, bow thruster, etc., the circuit wires must have circuit protection to comply with ABYC guidelines. Wires used for engine starting do not require circuit protection.
Control Circuit Connections (wires contained in the wire harness)
NOTE: The Remote Battery Switch/Solenoid Switch is designed to be controlled by momentary SPDT switch,
(included), or two momentary push button switches. Use minimum 16 AWG wire for the Control Circuit.
ToconnectDCpowertotheRemoteBatterySwitch/SolenoidSwitchControlCircuit:
1. Connect the red wire through a 10A (min) circuit protection device to DC+. The power source should be a direct connection to the battery.
2. Connect the black wire to DC ground.
ToconnectthemomentarySPDTConturaControlSwitch:
1. Connect the common load terminal of the Control Switch, pin 2, through a 2A (min) circuit protection device to DC+. Use a 24-hour power source (connected directly to the battery).
2. Connect the brown wire to the CLOSE side of the Control Switch, pin 3.
3. Connect the orange wire to the OPEN side of the Control Switch, pin 1.
4. Connect the LED power terminal of the Control Switch, pin 8, through 2A (min) circuit protection device to DC+. Note:Thisconnectioncansharethesamewire/fuseasstep#1above,(seediagram).
5. Connect the LED Ground terminal of the Control Switch, pin 7, to the yellow wire of the Remote Battery Switch.
Guarantee
Blue Sea Systems stands behind its products for as long as you own them. Find detailed information at www.bluesea.com/about. For customer service, call 800-222-7617.
1.965"
49.91mm
5.47"
138.94mm
4.50"
114.30mm
1.010"
25.65mm
Installation Instructions
1.125"
.595"
15.10mm
3.75"
95.25mm
3.00"
76.20mm
28.58mm
51.56mm
2.03"
1.450"
36.83mm
1.90"
48.26mm
0.830"
21.08mm
TEST CUT
HOLE IN
ACTUAL
CENTER
1.03"
26.16mm