Blue Angel Pumps BTU30 User Manual [en, es, fr]

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
1
The pedestal pump is designed for home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. Motor is air cooled; it is not designed to operate under water. A float switch is provided for automatic pump operation. This pump is not suitable for aquatic life.
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Caution indicates a
potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
1. Read these rules and
instructions carefully. Failure to follow these instructions could cause serious bodily injury and/or property damage.
Operating Instruction and Parts Manual BTU30
360901-002 1/07
Do not submerge
motor or allow motor to be exposed to water. Personal injury and/or death could result.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or death could result.
This pump is not
designed to handle salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty.
All wiring must be
performed by a qualified electrician.
If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.
A battery backup
system should be used. Call 1-888-636-6628 to order an emergency backup system.
Always disconnect the power source before attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor, water or discharge piping
when pump is connected to electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
1. Insert the float rod through hole in the switch lever (See Figure 1).
2. Place rubber grommet on float rod in temporary position.
3. Using pliers to hold the float rod, screw the float on as shown in Figure 1.
Pedestal Sump Pump
Figure 1
Description
Safety Guidelines
General Safety Information
Assembly
© 2007 Blue Angel™ Pumps
movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.
IMPORTANT: Make sure there is adequate room for float switch to move freely during operation.
7. Protect electrical cord from sharp object, hot surfaces, oil and chemicals. Avoid kinking the cord and replace damaged cords immediately.
8. A sump pit cover must be installed to prevent debris from clogging or damaging the pump.
Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
Never cut off the
round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.
9. Insert the float switch cord plug
directly into a 120 volt outlet (See Figure 4).
ADJUST AND TEST
1. Fill sump with water.
2. Adjust rubber grommet into a
permanent position on float rod so that the pump switches on with approximately 14” of water in the sump.
3. While the pump is draining the pit,
verify that the discharge piping is carrying the water to a point several feet away from the foundation.
4. If the pump discharge line is
exposed to freezing temperature, the exposed line must be pitched to drain. Trapped water will freeze and damage the pump.
1. A ground fault circuit interrupter (GFCI) is required.
2. This pump is for use on 120 Volt (single phase), 60 hz, 15 amp service and is equipped with a 3 conductor cord and a 3 prong grounding plug.
3. Install pump in a sump pit with minimum size as shown (See Figure
3). Construct sump pit of tile, concrete, steel or plastic.
4. Locate unit on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure (See Figure 3).
5. (Optional) Thread check valve (not included) into pump body carefully to avoid stripping or cross threading. Do not use pipe joint sealant.
6. Connect 1-1/4” rigid pipe to rubber boot on check valve. Reverse boot for 1-1/2” diameter pipe. Tighten hose clamps.
Support pump and
piping when assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.
Flood risk. If
flexible discharge hose is used, make sure pump is secured in sump pit to prevent
2
Operating Instructions and Parts Manual
Always disconnect the electrical supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.
1. Disassembly of the motor prior to
expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.
2. Keep pump inlet clean and free of all
foreign objects and inspect annually. A clogged inlet will damage pump.
3. Check pump monthly for proper
operation.
Note: Pump is equipped with an automatic reset thermal protector.
Figure 4
Installation
Figure 3
Maintenance
3
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Pump will not start or run
Pump starts and stops too often
Pump will not shut off or thermal protector turns off
Pump operates but delivers little or no water
1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective switch
5. Impeller
6. Float obstructed
1. Backflow of water from piping
2. Float out of adjustment
1. Defective switch
2. Obstacle in piping
3. Float obstructed
1. Low line voltage
2. Plugged impeller
1. If blown, replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace motor or pump
4. Replace switch (Blue Angel pedestal switch kit #56396)
5. If impeller will not turn, remove housing and remove blockage
6. Make sure float moves freely up and down
1. Install or replace check valve (Blue Angel check valve kit #66005-BLA)
2. Adjust grommet
1. Replace switch (Blue Angel pedestal switch kit #56396)
2. Remove pump and clean pump and piping
3. Make sure float moves freely up and down
1. If voltage is under 108 volts, check wiring size
2. Clean out impeller
Notes
BTU30
4
Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as shown in parts list
Address parts correspondence to: Correspondance: Puede escribirnos a:
Blue Angel 100 Production Drive Harrison, OH 45030 U.S.A.
Replacement Parts List Liste de Pièces de Rechange Lista de repuestos
Sírvase darnos la siguiente información:
- Número del modelo
- Número de serie (de haberlo)
- Descripción y número del repuesto según la lista
S’il vous plaît fournir l’information suivante:
- Numéro du Modèle
- Numéro de Série (si présent)
- Description et numéro de la pièce
Operating Instructions and Parts Manual
• Only use factory parts to repair this pump.
• Utiliser seulement les pièces de l’usine pour la réparation de cette pompe.
• Use sólo repuestos legítimos para reparar esta bomba.
For Replacement Parts, call 1-888-636-6628 Pour Les Pièces de Rechange, appeler 1-888-636-6628 Para ordenar repuestos, comuníquese con el distribuidor más cercano a su domicilio.
Ref. No. Part Number Nº de Ref. Description Description Descripción Numéro de Pièce No de Ref. Número del Repuesto
1 Float Kit Néc. de flotteur Piezas del flotante 57030-001
2 Switch Assembly Assem. d’interrupteur Ensamblaje del interruptor 56396
3 Float Guide Guide de flotteur Guía del flotador 01509001
4 Impeller Kit Néc. de turbine Piezas de la propela 60096-WYN1