Installation and User’s Manual
BLMI-300A
BLMI-500A
BLMI-650A
BLMI-900A
I512A-200
ver.201803_02
Table of Contents
Freight Claim Procedure(Important)
1.
Specifications .................................................................................. 4
1.1 Technical Specification
1.2 Product Dimensions
1.3 Accessories Included with the Unit
1.4 How to determine read model names and serial numbers
2. Installation & Operations Guide ................................................. 8
2.1 Location Requirements
2.2 Installation Requirements
2.3 Electrical Requirements
2.4 Installation Checklist
2.5 How to Remove Machine Panel
2.6 Bin Installation
2.7 Bin S/W Installation
2.8 Water supply & Drain Connections
2.9 Wire
2.10 Final Check
2.11 Test Run
3. Operation ........................................................................................ 18
3.1 Button
3.2 Status Light
3.3 7-Segments
3.4 Operation Cycle
3.5 Safety
3.6 Error Codes
4. Maintenance & Cleaning ............................................................. 22
4.1 Maintenance Period
4.2 Interior Cleaning & Sanitizing Procedure
4.2.1 Cleaning Procedure
4.2.2 Sanitizing Procedure
4.2.3 Product Disassembly
4.3 Level sensor Cleaning
4.4 Exterior Cleaning
4.5 Storage Container and Scoop
4.6 Air Filter
4.7 Condenser
4.8 How to Prepare Unit for Long Term Storage
2
Freight Claim Procedure(Important)
Inspect Immediately
This product has been carefully inspected and packed in accordance with the
carrier’s packing specifications. Responsibility for safe delivery has been
assumed by the carrier. If loss or damage occurs, you as the consignee must file
a claim with the carrier and hold the container for carrier’s inspection.
Visible Loss or Damage
Any external evidence of loss or damage must be fully described and noted on
your freight bill or express receipt and signed by the carrier’s agent. The claim
should be filed on a form available from the carrier.
Concealed Loss or Damage
Concealed loss or damage should be reported to the carrier and vendor within 24
hours af delivery.
After 24 hours the seller is not responsible for any freight damage incurred.
Keep the product as well as all of the original packaging material in a receiving
area for carrier's inspection.
Warning
Connect to potable water supply only.
Adult Supervision is required for safe use either by children under 8 years of age
or the developmentally disabled.
The warranty does not apply to the following.
Repair or replacement of parts required due to misuse, improper care or storage,
negligence, alteration, use of incompatible supplies or lack of specified maintenance.
Regular maintenance items.
Failures caused by improper or erratic voltages, adverse environmental or water
conditions, improper drainage, interruption in electrical or water supply.
Improper or unauthorized repair.
Any ice machine that has been installed and/or maintained inconsistent with the
instructions provided by Blue Air
3
1. Specifications
1.1 Technical Specification
● Electrical & Refrigerant Data
300A
Condenser
Rated Voltage
Rated Ampere
Compressor
Pump
Fan
Maximum Breaking
Capacity of Fuse Size
Designed Pressure
Refrigerant
Safety Approval
Sanitation Approval
Energy Star
CE
KC
Air Cooling
115V/60Hz/1Ph 220-240V/50Hz/1Ph
8A 6A
115 V 37 LRA 6.35RLA 198-254V 18.6LRA 4.04RLA 187-254V 23.4LRA 4.46RLA
115V 0.53FLA 59.9W 220-230V 0.16FLA 35.9W 220-230V 0.2FLA 41.3W
115V 0.68FLA 75.2W 220-230V 0.16FLA 35.9W 220-230V 0.29FLA 62.2W
15A -
HI –580 / LO –320 psig HI – 380 / LO – 195psig
R-410A 400g (14.1OZ) R-404A 450g (15.8OZ)
UL N/A
ETL N/A
Certified N/A
N/A Certified
N/A N/A
220V/60Hz/1Ph
6A
-
HI – 380 / LO – 195psig
R-404A 650g (22.9OZ)
N/A
N/A
N/A
N/A
Certified
500A
Condenser
Rated Voltage
Rated Ampere
Compressor
Pump
Fan
Maximum Breaking
Capacity of Fuse Size
Designed Pressure
Refrigerant
Safety Approval
Sanitation Approval
Energy Star
CE
KC
Air Cooling
115V/60Hz/1Ph 220-240V/50Hz/1Ph
14A 7A
115 V 57 LRA 11.4RLA 198-254V 18.6LRA 4.04RLA 198-254V 30.0LRA 4.35 RLA
115V 0.53FLA 59.9W 220-230V 0.16FLA 35.9W 220-230V 0.2FLA 41.3W
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
25A -
HI – 580 / LO –320 psig HI – 380 / LO – 195psig
R-410A 450g (15.8OZ) R-404A 650g (22.9OZ)
UL N/A
ETL N/A
Certified N/A
N/A Certified
N/A N/A
4
220V/60Hz/1Ph
7A
-
HI – 380 / LO – 195psig
R-404A 600g (21.1OZ)
N/A
N/A
N/A
N/A
Certified
650A
Condenser
Rated Voltage
Rated Ampere
Compressor
Pump
Fan
Maximum Breaking
Capacity of Fuse Size
Designed Pressure
Refrigerant
Safety Approval
Sanitation Approval
Energy Star
CE
KC
Air Cooling
208-230V60Hz/1Ph 220-240V/50Hz/1Ph
9A 6A
208~230 V 29LRA 6.8 RLA 198 ~ 264 V 24 LRA 5.9RLA 208~230 V 29LRA 5.6 RLA
115V 0.55FLA 63.5W 230V/50Hz 0.29FLA 61.7W 220V/60Hz 0.28FLA 61.0W
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
15A -
HI –580 / LO –320 psig HI –580 / LO –320 psig
R-410A 700g (24.6OZ) R-410A 700g (24.6OZ)
UL N/A
ETL N/A
Certified N/A
N/A
N/A N/A
Certified N/A
220V/60Hz/1Ph
6A
-
HI –580 / LO –320 psig
R-410A 700g (24.6OZ)
N/A
N/A
N/A
Certified
900A
Condenser
Rated Voltage
Rated Ampere
Compressor
Pump
Fan
Maximum Breaking
Capacity of Fuse Size
Designed Pressure
Refrigerant
Safety Approval
Sanitation Approval
Energy Star
CE
KC
Air Cooling
208-230V/60Hz/1Ph 220-240V/50Hz/1Ph
9A 9A
208~230V 41LRA 7.6RLA
115V 0.55FLA 63.5W 230V/50Hz 0.29FLA 61.7W 220V/60Hz 0.28FLA 61.0W
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
15A -
HI –580 / LO –320 psig HI –580 / LO –320 psig
R-410A 1100g (38.8OZ) R-410A 900g (31.7OZ)
UL N/A
ETL N/A
N/A N/A
N/A
N/A N/A
220V 50LRA 9.4 RLA 208 ~ 230 V 48 LRA 8.8RLA
Certified N/A
5
220V/60Hz/1Ph
9A
-
HI –580 / LO –320 psig
R-410A 1100g (38.8OZ)
N/A
N/A
N/A
Certified
● Approximate Ice Production
No Model Rated Voltage
1 300A 115V/60Hz/1Ph 323lbs/day (146 kg/day)
2 300A 220-240V/50Hz/1Ph 303lbs/day (137 kg/day)
3
4
5
6
7
8
9
10
300A 220V/60Hz/1Ph 337lbs/day (153 kg/day)
500A 115V/60Hz/1Ph 517lbs/day (235 kg/day)
500A 220-240V/50Hz/1Ph 463lbs/day (210 kg/day)
500A 220V/60Hz/1Ph 457lbs/day (208 kg/day)
650A 208-230V60Hz/1Ph 625lbs/day (283 kg/day)
650A 220-240V/50Hz/1Ph 726lbs/day (329 kg/day)
650A 220V/60Hz/1Ph 643lbs/day (292 kg/day)
900A 208-230V60Hz/1Ph 890lbs/day (404 kg/day)
AT 70 °F / WT 50°F
AT 21 °C / WT 10°C
11
12
900A 220-240V/50Hz/1Ph 858lbs/day (389 kg/day)
900A 220V/60Hz/1Ph 915lbs/day (415 kg/day)
6
1.2 Product Dimensions
● 300A/500A
FRONT
TOP
SIDE
REAR
7
● 650A
FRONT
TOP
SIDE
REAR
8
● 900A
FRONT
TOP
SIDE
REAR
9
1.3 Accessories Included with the Unit
No Name Picture Quantity
1 Bin switch 1
2 M5 Bolt 4
3 Screw M6 2
4 Earth Screw 1
5 User Manual 1
1.4 How to determine model names and serial numbers
1.4.1 Model names
BL : Blueair
M : Modular
(U:Undercounter)
I : Crescentice
1.4.2 Serial number
BLMI-900A
a b d e f c
Year 2015 2016 2017 2018 2019 2020
Mark G H J K M N
Month Jan. Feb. Mar. Apr. May. Jun.
Mark 1 2 3 4 5 6
Month Jul. Aug. Sep. Oct. Nov. Dec.
Mark 7 8 9 A B C
Air - cooled
daily ice production in pound
a (4 digits) : CIS code for specific model
b (1 digit) : Product group
c (2 digits) : Manufacturing site
(supplier code)
d (1 digit) : Manufacturing year
e (1 digit) : Manufacturing month
f (5 digit) : Serial number (00001 ~ 99999)
10
2. Installation & Operation Guide
WARNING
-
The ice machine should be installed, following the local regulations of the country, state and region.
- Read the manual thoroughly before installation. Incorrect installation may cause
malfunction, or bodily injury and death.
- Do not drop tools into the bin or the floor of the unit during installation. It may cause
injure during routine operation of the machine.
- Do not operate unit with enclosure removed. This is marked by a sticker labelled "CAUTION
or WARNING - Parts. Do Not Operate Unit With Enclosure Removed."
(When disassembly for cleaning or similar servicing exposes moving parts.)
2.1 Location Requirements
The installation location of the ice machine should satisfy following conditions.
If the location does not satisfy these conditions, do not install the machines in that location.
The installment location must be changed to meet following conditions.
- The location should be in indoors and have good ventilation
- The location should not be near a heat source and should not be in direct sunlight
- The operating temperature at the location should be between 45°F- 100°F(7°C- 38°C).
- The location should have access to a water supply, drainage and an easily connected
source of electricity
- The location should not have any obstacles, disturbing air circulation(heat exchange)
- The location should have enough clearance for wiring and plumbing on the rear.
- The location should have no food waste nor food contaminant.
- The location should support the full weight of the machine filled with ice.
2.2 Installation Requirements
- The head and bin should be level.
- The vent of the of ice machine and drain of the bin should be separated.
- The drain tip of the bin should have an air gap.
- The ice machine and bin should be completely cleaned after installation.
- The drain line should be easily separated from the ice machine.
- There must be minimum of (8 inches (20 cm) )of clearance, around, above and below the
machine for enough air circulation and maintenance.
- Carefully align the ice machine with the bin to ensure a secure seal.
11