Blueair BBB23 - 1B, BBB69 - 3B, BBB59 - 2B, BBB59 - 2S, BBB69 - 3S Installation & Operation Manual

...
Installation & Operation Manual
Glass Door Countertop Refrigerator
Please read this manual completely before installing or operating this unit!
BBB23 - 1B / 1S BBB59 - 2B / 2S BBB69 - 3B / 3S
BBB90
4B / 4S
BBB23 - 1BG / 1SG BBB59 - 2BG / 2SG
BBB69
3BG / 3SG
BBB90 - 4BG / 4SG
BDD23 -1B / 1
S
Blue Air reserves the right to make product modification at any time. Specifications and Designs are subject to change without notice.
BDD59 - 2B / 2S BDD69 - 3B / 3S BDD90 - 4B / 4S
IMPORTANT SAFETY INSTRUCTION ( SAVE THESE INSTRUCTIONS )
Visit our website at www.blueairinc.com
Contents
Specifications ……………………………….............................
Installation ……………………………………………………….
3
4
Maintenance & Cleaning ………………………………………
Operation & Caution “ Important” ………………………….
Air Hose & Tower Installation Schematic Diagram………..
4
5
6
Beer Line & COLine Installation Schematic Diagram…..
Troubleshooting ……………………………..............................
7
8
Blue Air Refrigeration has a Nationwide Service Network
to provide timely services for our customer’s needs.
Service Contact
Please call or fax us to the following numbers.
Blue Air Refrigeration Nationwide Service Network
Toll Free, 1-866-677-8500
TEL, (310) 808-0102
Fax, (310) 808-0242/0262
2
Specifications
Product Back Ba
r
Model
BBB23-1B/1S BBB59-2B/2S BBB69-3B/3S BBB90-4B/4S
BBB23-1BG/1SG BBB59-2BG/2SG BBB69-3BG/3SG BBB90-4BG/4SG
Capacity (cu.ft) 7 19 23 31.5
Exterior Dimensions [IN]
(1B/1S - Including 4" Casters)
W 23 2/5 59 69 90 1/3
D 29 1/2 27 1/9 27 1/9 27 1/9
H
39 1/4
37
37
37
Net Weight (lbs) Solid/Glass Door 187/198 276/298 298/320 441/474
Rated Voltage AC115V /60Hz
Amps 3.3 A 6.3 A 6.3 A 6.3 A
Compressor (HP) 1/5 HP 3/8 HP 3/8 HP 3/8 HP
Type of Power Cord NEMA 5-15
Shelves 2EA 4EA 4EA 6EA
Number of Doors 1 2 2 3
Refrigerant R-134a
Range of Temperature 32~40°F
Product Direct Draw Beer Dispenser
Model BDD23-1B/1S BDD59-2B/2S BDD69-3B/3S BDD90-4B/4S
Capacity (cu.ft) 7 19 23 31.5
Exterior Dimensions [IN]
(1B/1S - Including 4" Casters)
(Except Height Tower)
W 23 2/5 59 69 90 1/3
D 29 1/2 27 1/9 27 1/9 27 1/9 H 39 1/4 37 37 37
Net Weight (lbs) 187 276 298 441
Rated Voltage AC115V /60Hz
A
mps
3.3 A
6.3 A
6.3 A
6.3 A
Compressor (HP) 1/5 HP 3/8 HP 3/8 HP 3/8 HP
Type of Power Cord NEMA 5-15
1/2 Barrels 1EA 2EA 3EA 4EA
Number of Doors 1 2 2 3
Refrigerant R-134a
Ran
g
e of Temperature 32~40°F
3
Specifications and Designs are subject to change without notice.The name plate (including Serial No.) is located on the upper left side of the cabinet interior.
gp
Installation
1. INDOOR USE ONLY
• This unit is intended for indoor use only.
2. LOCATION
• Be sure that the location is strong enough to support the total weights of the unit and its contents.
• Keep the unit away from sunlight and other heat generating equipment.
• The minimum clearance between the back of the unit and the wall should be at least 7 inches.
3. INSTALLING CASTORS
• Ensure that castors with brake are installed in front.
4. LEVEL
• The unit should be level to provide adequate drainage.
5. ELECTRICAL CONNECTION
• The unit should be plugged into a 115V/60Hz, grounded wall receptacle to prevent electrical shock and fire hazards.
• Do not plug other electrical units into same wall receptacle this unit is plugged into.
• Do not use an extension cord.
• Compressor warranties are void if the compressor burns out due to low voltage.
6. INSTALLING SHELF
• Install shelves using shelf-clips provided.
Maintenance & Cleaning
1
. To maintain proper refrigeration performance, the condenser fins should be
checked monthly and cleaned with a soft brush or vacuum cleaner as needed.
2. Wait at least 6 minutes after unplugging the unit before replugging it in.
3. The interior and exterior of the unit can be cleaned with mild detergent and water.
• Do not use abrasive cleaners to avoid scratching the unit.
4
4. The door-gasket should be cleaned to maintain proper seal.