General safety instructions
The Blueair 500/600 Series air purier is an electrical appliance. Please read the safety instructions before use and take the necessary precautions to reduce the risk of re, electric shock or injury. The Blueair Limited
Warranty applies only if the unit is used according to these instructions.
7 Filters
Thank you for choosing Blueair. Before you start using your Blueair air purier, take a few minutes to become familiar with the basics.
Filter replacement
Be sure to change your Blueair lters according to the recommended lter replacement schedule. This helps keep your Blueair air purier running in top condition. See page 6.
Extend your warranty
Complete and send your warranty card to Blueair today to extend your limited warranty.
Help keep the planet healthy, too
Blueair air puriers provide maximum improvement of indoor air quality with minimum impact on the environment. The entire unit can be recycled.
Use the grounded power cable provided with your Blueair unit. The
plug ts into a grounded outlet. Do not alter the plug in any way.
Use the cable provided to plug the Blueair unit directly into an
appropriate electrical outlet (please refer to the voltage label on your unit). The cable is packaged beneath the unit.
This appliance is not intended for use by children or other persons whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely unless properly supervised.
Children should not be allowed to tamper with the controls or play with the appliance.
Placement
Place the unit in a location that allows air to circulate freely in, out and around the unit. The minimum acceptable distance from another object is 4˝ or 10 cm. Use only genuine Blueair lters. Do not place the unit:
Directly on or against soft furnishings, such as bedding or curtains.
Near sources of heat, such as radiators, fireplaces or ovens.
Near wet areas, such as bathrooms or laundry rooms, where it may come into contact with water.
Outdoors.
2 Blueair 500/600 Series Blueair 500/600 Series 3
English English
Settings*
Plug the cable into a grounded wall outlet and turn on your Blueair unit. The blue light-emitting diode indicates that the unit is working. Set the control knob to maximum speed, which is recommended for fast initial cleaning, daytime use, or very polluted air. After a few minutes, adjust the control to the desired speed. Minimum speed is generally recommended for nighttime use.
Care and maintenance
Blueair air puriers feature high quality design, materials and workman­ship. To keep your unit in top condition, we recommend routine cleaning.
Vacuum the air intake grille from the inside when you remove
the lters to replace them.
Vacuum the small inlets with a soft brush attachment.
Wipe the exterior of the unit with a soft, clean, damp cloth.
Never clean with gasoline, chemical solvents or corrosive material
also as these agents may damage the surface.
Do not allow foreign objects to enter the ventilation or exhaust
openings. This may cause electric shock or damage the unit.
Do not try to repair or adjust any of the electrical or mechanical
functions on your Blueair unit yourself. Contact your local dealer or Blueair for warranty information.
How it works
Air passes through an ion chamber where airborne particles are charged with negative ions. Charged particles are drawn to the HEPASilent™ lter surface. Puried air, which is virtually contaminant­free is re-circulated into the room.
Getting the most from your Blueair system
The Blueair system is easy to use. Make sure your unit is the right size for your room, and change the lters according to recommended lter replacement schedule. Remember that, just as air conditioners and heaters have limits to the volume of air they can cool or heat, every air purication system has limits to the volume of air it can clean. Follow these common-sense guidelines.
Close your windows
You wouldn’t throw open your windows on a hot summer day and expect your air conditioner to work efciently, because you can feel the hot air coming in and the cool air going out. Even though you can’t see the contaminated air coming in and the clean air going out, the same logic applies to your air purier.
Close your doors, too
Just as you might seal off part of your house on a cold winter night to keep your heater working more efciently, seal off the room in which your system is working for best results. This is especially important for people using a Blueair system to ease nighttime asthma or allergy attacks.
Run your system 24 hours per day
For best results, run your Blueair unit 24 hours a day, 7 days a week. Round-the-clock operation ensures that a continuous supply of clean, ltered air constantly circulates throughout the room. Blueair systems are designed for phenomenally low power usage. In fact, it costs about the same to power a Blueair air purier as it does to power a single light bulb, depending on the unit and the operating speed.
* For Blueair E Series units (250E, 450E, 550E, 650E), please refer to the separate sheet included with your unit for instructions on settings.
Blueair 500/600 Series 54 Blueair 500/600 Series
English English
Changing the filters
Step 1
Unplug the unit and lift the lid from the top of the unit.
Step 3
Remove the filters on each side. Vacuum the grille from the inside.
Step 5
Place the third filter on top of the unit and ensure that the side with the words “facing out” is facing upwards.
Step 2
Remove the filter on top.
Step 4
Guide the first and second replace­ment filters into the side slots. Ensure that the side with the words “facing out” is turned toward the outer wall of the unit.
Step 6
Snap the lid back into place.
Filters
Patented HEPASilent™ technology makes the Blueair 500/600 Series incredibly quiet. The unit comes with a complete set of three HEPASilent™ lters already installed.
Particle Filter Kit. Includes three particle lters that remove dust, pollen, bacteria, pet dander, mold spores and other airborne particles. The particle lter is made of polypropylene, which help mechanically lter out airborne particles. To maximize lter effectiveness, particles are negatively charged by the Blueair unit before reaching the lters.
Smokestop™ Filter Kit. Includes three lters with enhanced active carbon to remove gaseous pollutants such as cigarette and cigar smoke or other VOCs (volatile organic compounds, including household paints and other chemicals). You may notice a slight odor from the enhanced active carbon when the lter is rst used; this will quickly dissipate.
For optimal performance, Blueair recommends that you replace filters every six (6) months.
We offer a convenient Filter Subscription Program in some countries. Contact your local dealer or Blueair to nd out whether the program is available to you.
IMPORTANT! Use only genuine Blueair lters to ensure proper function of your unit and to qualify for full warranty coverage.
Customer’s record
The model number and serial number of this product can be found on the bottom of the unit. Please note them in the space provided below and keep for future reference.
Model number Dealer’s name
Serial number Dealer’s address
Date of purchase Telephone number
6 Blueair 500/600 Series Blueair 500/600 Series 7
Loading...
+ 7 hidden pages