Bloomfield SS-10, SS-10D Installation Instructions Manual

ELECTRICAL
MODEL VOLTS WATTS AMPS PHASE WIRING
SS-10 SS-10
SS-10 SS-10D SS-10D SS-10D 240
120 450 208 240 120 208
338 450 450 338 450
3.8
1.6
1.9
3.8
1.6
1.9 SINGLE
SINGLE 14 AWB Cu SINGLE SINGLE SINGLE SINGLE
FIELD
GAUGE
14 AWB Cu 14 AWB Cu 14 AWB Cu 14 AWB Cu 14 AWB Cu 75°C
CUTOUT DETAILS
11
(279)
8 1/2
(216)
TOP CUTOUT
RATING
INCHES
(MM)
TEMP.
75°C 75°C 75°C 75°C 75°C
INSTALLATION INSTRUCTIONS
BUILT-IN ROUND FOOD WARMERS
CLEARANCES
SUGGESTED CLEARANCES
UNIT TO THE NEAREST SURFACE
BACK SIDE BOTTOM FRONT
1 1
(25)
SEE CONDITIONS OF ACCEPTABILITY BELOW
WHEN CONTROL BOX IS LOCATED BELOW THE UNIT, FRONT CLEARANCE CAN BE 2 INCHES.
NOTE: DEPENDING ON THE INSTALLATION, CLEARANCES CAN BE CHANGED UPON EVALUATIONS TO UL STANDARDS.
(25) (216)
8 1/2
PRODUCT DIMENSIONS
MODELS SS-10 (D)
4
(102)
2 3/8
(60)
#32 DRILL 2 HOLES
3 7/16
(87)
1
(25)
FRONT PANEL CUTOUT
1 7/8
(48)
3 3/16
(81)
4 15/16
(125)
#19 DRILL 2 HOLES
INSTALLATION INSTRUCTIONS
UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER. THE INSTALLATION OF RECOGNIZED COMPONENT UNITS REQUIRES ADDITIONAL EVALUATIONS TO UNDERWRITERS LABORATORIES INC. STANDARDS.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. This appliance shall be installed in an all metal counter with suitable wiring and control enclosures conforming to national and local electrical codes.
2. Electrical component temperatures, including wiring, within and surrounding the appliance must be monitored in the end use installation for suitability.
3. Electrical grounding of all dead metal parts must be reliably connected to the grounding means of the appliance and must comply with the requirements outlined in appropriate Underwriters Laboratories Inc. classification, national and local electrical codes.
4. Increased clearances are required if storage of combustible materials is in close proximity to this appliance.
5. Unit shall be accessible for servicing from the bottom.
6. The name/rating plate information shall be accessible.
7. For water and waste connections: This appliance is to be installed to comply with the applicable federal, state or local plumbing codes.
TO FABRICATE:
1. Lay out "cutout" dimensions on countertop and front apron.
2. Lay out and fabricate control panel holes in counter apron using the control box as a template.
3. Cut out and/or drill holes as required in countertop and apron.
4. Unit must be accessible for servicing from the bottom.
WELLS/BLOOMFIELD * VERDI, NV
NOTE: * CONTROL MUST NOT BE MOUNTED IN THIS HIGH
12
(305)
4 7/16
(113)
TO INSTALL:
1. Locate warmer and control box over countertop cutout. Pass control through opening, then mount control electrical box to the rear of the apron.
3. From underneath, insert a screwdriver into "slots" on the wellslok frame and twist the "ears" outward to secure the flange tightly to the countertop (see detail above).
4. Mount the control panel to the front of the counter apron using the screws supplied. RECOMMENDATION: Units with drains should be installed with a union for ease of service.
WARMER FLANGE
GASKET
TEMPERATURE AREA.
*
1
(25)
7/8 (22)
SCREWDRIVER
COUNTERTOP
8 1/2 (216)
WELLSLOK
1/2 NPT (D MODELS ONLY)
METAL SHIELD
37122-3 REV (-)
8 3/4 (222)