NOTE: This Programming Manual is intended for use by qualified technical
personnel only. Persons not qualified in the servicing of Bloomfield
equipment must not attempt to install or program this equipment.
CAUTION: DO NOT plug in or energize this appliance until Installation
Instructions are read and followed. Damage to the Brewer will occur if
these instructions are not followed.
WARNING: All installation procedures must be performed by a qualified
technician with full knowledge of all applicable electrical and plumbing
codes. Failure could result in property damage and personal injury.
WARNING:This appliance dispenses very hot liquid. Serious bodily
injury from scalding can occur from contact with dispensed liquids.
WARNING:All servicing requiring access to non-insulated components
must be performed by a qualified service technician. Do not open any
access panels which require the use of tools. Failure to follow these
directions can result in electrical shock.
NOTE:This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is sold or
moved to another location.
xi
638 p/n 74781 SS-1 Programming Manual
TABLE OF CONTENTS
General Procedures & PrecautionsPage xi
Electrical Specifications Page 1
Operating Instructions Page 2
Programming Instructions
Control Panel Keys Page 6
To Access the Programming Mode Page 9
Tips for Navigating in the Programming Mode Page 9
Programming Table Page 8
Programming the Satellite Brewer
To over-ride the Brew Wait
Mode, press and hold the
BREW switch for 3 seconds
when the brewer is in Brew Wait
mode (i.e. when brew light is
flashing). The brew will proceed
immediately regardless of water
temperature. This feature
should only be used when
testing water volume, otherwise
the brew will proceed with the
water below the precise brew
temperature. (The Brew Wait
option can also be permanently
disabled in the programming
Before connecting to the electricity, make sure the Satellite Brewer
has been properly connected to the water supply. When electricity
has been connected to the unit, there will be a momentary flash of
the power light. Turn the brewer on by depressing the ON/OFF
switch. The brewer will start to fill the tank with the message on the
screen “filling…”. With the proper water supply the tank should be
filled in about 2½ minutes. Once filled, the heating element will
come on until the proper tank temperature has been reached,
(which will take about 20 minutes on 120-Volt models or about 12
minutes on 120/240 Volt models).
In regular operating mode, the Satellite Brewer maintains the tank
temperature within +/- 1ºF of the brew temperature. Normally this
will mean that a brew will be started as soon as the BREW switch
is depressed. However, there may be a slight delay if the BREW
switch is depressed immediately after a brew has been completed
(notably on 120-volt models). If the tank temperature is below
the brew temperature, the brew will be delayed going into the
“Brew Wait” mode, with the brew light flashing, and the message
on the screen “heating…”. As soon as the correct temperature
is reached the brew will commence with the brew light on
continuously during the brew. The time remaining in the brew will
count down on the display. During the brew if the BREW switch
is depressed, it will be ignored. Only if the brew is complete can
another brew be started.
Note: the following safety features have been incorporated to
prevent multiple unattended brews:
• When the “Brew” light is on or flashing, repeated pressing of
mode.
Consult the Programming
section in this manual.)
3. Brew Cancel
4. Normal Operation
(Non Brewing):
* Only one brew can be stored in “Brew Wait” at a time.
To cancel a brew in progress, or a brew waiting, depress the
CANCEL switch: two beeps will sound and the “Brew” light will go
out. Water flowing to the brew basket will be stopped immediately,
but, if there is already water in the brew basket, it will take a few
moments to drip through as coffee.
When the unit is not brewing, the Satellite Brewer maintains the
water temperature at the Precise Temperature for Brewing™
(PTB™). The heating element will cycle on and off automatically
to maintain this temperature.
the BREW switch will be ignored, (there will be a beep each
time it is pressed). A Brew will only be activated or put in Brew
Wait when the “Brew” light is off. (If BREW switch is pressed
and held 3 seconds during “Brew Wait” the brew will proceed
immediately.)
638 p/n 74781 SS-1 Programming Manual
2
OPERATING INSTRUCTIONS (continued)
To view the water temperature on the screen, the Satellite Brewer
must be ON, and not brewing or in the filling mode. Press and hold
the 4th key, and depress the 6th key. The actual water
temperature will be displayed for 3 seconds.
The Satellite Brewer maintains a count of the number of completed
brews for a 7-day period. To access the count, turn the brewer
OFF. In the OFF mode, press and hold the CANCEL key for 3
seconds. The current day and brew count will be displayed.
Depress the ON/OFF key repeatedly to view each preceding day.
When all 7 days have been displayed a 7-day total will be
displayed. If you wish to exit the daily brew count before viewing
all of the days, press CANCEL key.
To turn the brewer OFF, press the ON/OFF switch: 2 beeps will be
heard and the brewer will be turned OFF, indicated by all lights
being off, (including any warmer plates on decanter brewers). To
turn the brewer ON, press the ON/OFF switch: 2 beeps will sound,
all lights will flash once, then the “Power” light will remain on, (the
“Heat” light may come on if water temperature is too low).
The factory programmed Satellite Brewer has the automatic timer
turned off. To set the automatic timer, refer to the Programming
section in this manual, “Time Functions” Menu. If the Automatic
Timer feature is programmed off, the brewer can be turned on and
off by depressing the ON/OFF switch, as noted above.
* When the Automatic Timer feature is programmed ON the
Satellite Brewer will turn on and off automatically, at a
programmed time, Monday to Friday; with a separate on and
off programmed time schedule for Saturday and Sunday.
* Temporarily Overriding the Automatic On/Off function. While in
the automatic timed OFF mode the brewer can be started by
depressing the ON/OFF switch. The brewer will remain on
until the automatic programmed OFF time, when it will turn off
and resume normal automatic timed functioning. Similarly, if
turned OFF during the automatic timed ON mode the brewer
will remain OFF until the next programmed ON time, when it
will turn on and resume normal automatic timed functioning.
If the Satellite Brewer automatic timer is OFF (the factory setting)
and power is disconnected, the brewer will start up when power is
restored, in the mode it had been in prior to the power disconnect.
If the Satellite Brewer has the timer setting ON and power is
disconnected, the brewer will start up in the mode that it should be
in at the time the power is restored.
638 p/n 74781 SS-1 Programming Manual
5. View Water Temperature
in Tank
6. Daily Brew Count
7. ON/OFF – Non Automatic
Timer
8. ON/OFF – Automatic
Timer Feature
9. Automatic Start-Up in
Previous Mode
3
OPERATING INSTRUCTIONS (continued)
10. Brew Volume - Viewing
Programmed Brew
Volume
11. Changing Brew Volume
12. Clock
Battery Backup of Time
13. Changing Day and Time
14. After Hours™
Consult the Programming
section in this manual to set the
After Hours™ mode.
The factory programming has
the After Hours™ mode turned
OFF.
The Satellite Brewer can have up to 4 different brew volumes.
When a volume other than the standard, or first brew volume, is
selected, the Satellite Brewer will complete that volume and then
automatically reset to the standard, or first brew volume.
Press the required volume key. If a volume is programmed for that
key, the volume will be displayed on the screen for 3 seconds and
the light above the key will be turned on. If no volume is
programmed, the previous light will remain on and the screen will
read “no volume prog” (i.e. no volume programmed). When a brew
volume other than the 1st, or standard brew volume is selected, the
Satellite Brewer will complete the brew then return to the 1st or
standard brew volume automatically.
The Satellite Brewer has a battery backup system which will
maintain the proper time during power failures, or when the brewer
is unplugged (even for very prolonged periods of time). Normally
there will not be a need to set the time except for Daylight Saving
Time changes, or moving the brewer to different time zones.
To change time, turn the Satellite Brewer off. Press the 2nd key
twice followed by the 1st key twice to access the time change
mode, (i.e. press CANCEL, CANCEL, BREW, BREW). In the time
change mode the screen will read “Day:” followed by the current
day setting. Use the 6th key to advance the day, or the 5th key to
reverse. When day has been properly set, press the 3rd key. The
screen will now read “Time:” with the set time on the screen, the
hour and am or pm flashing. Use the 5th key to go back or the 6th
key to advance the hour, making sure that the am or pm is correct.
When the hour and am/pm is correctly set, press the 3rd key, and
the screen will read “Time:” with the set time on the screen,
minutes flashing. As previously, use the 5th or 6th keys to adjust
the minutes, and press the 3rd key when complete. The Satellite
Brewer will return to the off mode. (Changing time can also be
done in the regular programming mode.)
The After Hours™ can be programmed to come on from 1 to 6
hours after the last brew. When the Satellite Brewer goes into the
After Hours™ mode, the water in the tank will be allowed to drop
from the normal brewing temperature and will reheat less
frequently – this feature saves energy and extend component life.
While in the After Hours mode, the power light will flash
continuously. When the BREW switch is pressed the Satellite
Brewer automatically reverts back to normal operation, heating the
water to the Precise Temperature for Brewing™ (PTB™), before
starting the brew. (The power light will be on continuously and the
Brew light will flash until the correct water temperature is reached.)
638 p/n 74781 SS-1 Programming Manual
4
OPERATING INSTRUCTIONS (continued)
The Satellite Brewer factory programming has the Countdown
Quality Timer™ turned OFF. Consult the Programming section in
this manual to activate the Countdown Quality Timer™ feature:
* A Countdown Quality Timer™ is availa ble for the last brew.
The timer can be set from 20 to 120 minutes (in 5-minute
increments). When a brew is completed, the countdown
time will begin. At the end of the selected time there will
be two beeps and the volume light will flash continuously
until reset. When a new brew is started the timer will be
reset automatically.
If a particular brew volume has utilized the pulse or pre-infusion
option, that volume will be displayed with an asterisk (*) after the
volume. As an example “Volume#2*” would indicate that the
second programmed brew volume has utilized the pulse or
pre-infusion program options.
If the Keypadlock™ feature is activated, there will be no response
by the brewer when the keys are depressed (except for the beep
after a key is depressed). To temporarily “unlock” the keypad,
press and hold the CANCEL key for 6 seconds. A beep will be
heard indicating the keypad is now “unlocked”; a brew can be
initiated, etc. The keypad will remain unlocked until the brew is
completed, then automatically return to keypadlock™ mode. If a
brew is not initiated 60 seconds after “unlocking”, the system will
time out and return to the “locked” position.
To view filter statistics, turn the brewer off. Press and hold the 6th
key, and touch the 3rd (ON/OFF) key. Total Water Volume
(TotalVol.) Touch the 3rd key again to view the filter life (FltrLife:).
The percentage of the filter that has been used will be displayed.
(If the filter option is used, the filter life volume needs to be entered
in the program – see Programming section in this manual, Service
& Counters Menu.)
15. Countdown Quality
Timer™
16. Pulse or Pre-Infusion
Volume Options
To set these features, refer to
the Programming section in this
manual, Brew Settings Menu.
17. Keypadlock™
To set the feature refer to the
Programming section in this
manual, Machine Settings
Menu. This feature is OFF in
the standard factory settings.