Bloomfield SATELLITE BREWERS Operation Manual

BLOOMFIELD INDUSTRIES
V
10 SUNNEN DRIVE
St. Louis, MO 63143
telephone: 314-781-2777
fax: 314-781-2714
www.wellsbloomfield.com
638
for
SATELLITE BREWERS
BREW
BREW
HEAT
Volume
CANC EL
POWER
ON
OFF
CAUT IO N
HOT LIQU ID
OLUMES
LIFT FOR
HOT WATER
E-Max BREWERS are covered under
U. S. Patents #5704275, 5862738, 6095031.
Other U.S. Patents and Canadian Patents Pending
p/n 2m-74781 Rev. C P638 090327 rms
GENERAL PROCEDURES & PRECAUTIONS
NOTE: This Programming Manual is intended for use by qualified technical
personnel only. Persons not qualified in the servicing of Bloomfield equipment must not attempt to install or program this equipment.
CAUTION: DO NOT plug in or energize this appliance until Installation
Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
WARNING: All installation procedures must be performed by a qualified
technician with full knowledge of all applicable electrical and plumbing codes. Failure could result in property damage and personal injury.
WARNING: This appliance dispenses very hot liquid. Serious bodily
injury from scalding can occur from contact with dispensed liquids.
WARNING: All servicing requiring access to non-insulated components
must be performed by a qualified service technician. Do not open any access panels which require the use of tools. Failure to follow these directions can result in electrical shock.
NOTE: This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is sold or moved to another location.
xi
638 p/n 74781 SS-1 Programming Manual
TABLE OF CONTENTS
General Procedures & Precautions Page xi Electrical Specifications Page 1 Operating Instructions Page 2 Programming Instructions
Control Panel Keys Page 6 To Access the Programming Mode Page 9 Tips for Navigating in the Programming Mode Page 9
Programming Table Page 8 Programming the Satellite Brewer
Brew Settings Menu Page 10 Time Functions Page 11 Machine Settings Page 12 Factory Settings Page 13 Calibration instructions Page 14 Brew and Pre-Infusion Capabilities Page 15 Pulse Feature Operation Page 16 Water Delivery (Outflow) Rates: Page 16 Pulse Examples Page 17
Test Program Page 18
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
SATELLITE BREWER
MODEL WATTS VOLTS HZ CIRCUIT REQUIRED
9511J 3890 200V 50/60 3 + ground 3 PHASE WIRE TO CIRCUIT BREAKER
638 p/n 74781 SS-1 Programming Manual
1
OPERATING INSTRUCTIONS – SATELLITE BREWER
1. Energizing the Brewer
2. Brewing (PTB™ - Precise Temperature Brewing™ )
To over-ride the Brew Wait Mode, press and hold the
BREW switch for 3 seconds when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediately regardless of water temperature. This feature should only be used when testing water volume, otherwise the brew will proceed with the water below the precise brew temperature. (The Brew Wait option can also be permanently disabled in the programming
Before connecting to the electricity, make sure the Satellite Brewer has been properly connected to the water supply. When electricity has been connected to the unit, there will be a momentary flash of the power light. Turn the brewer on by depressing the ON/OFF switch. The brewer will start to fill the tank with the message on the screen “filling…”. With the proper water supply the tank should be filled in about 2½ minutes. Once filled, the heating element will come on until the proper tank temperature has been reached, (which will take about 20 minutes on 120-Volt models or about 12 minutes on 120/240 Volt models).
In regular operating mode, the Satellite Brewer maintains the tank temperature within +/- 1ºF of the brew temperature. Normally this will mean that a brew will be started as soon as the BREW switch is depressed. However, there may be a slight delay if the BREW switch is depressed immediately after a brew has been completed (notably on 120-volt models). If the tank temperature is below the brew temperature, the brew will be delayed going into the “Brew Wait” mode, with the brew light flashing, and the message on the screen “heating…”. As soon as the correct temperature is reached the brew will commence with the brew light on continuously during the brew. The time remaining in the brew will count down on the display. During the brew if the BREW switch is depressed, it will be ignored. Only if the brew is complete can another brew be started.
Note: the following safety features have been incorporated to prevent multiple unattended brews:
When the “Brew” light is on or flashing, repeated pressing of
mode. Consult the Programming section in this manual.)
3. Brew Cancel
4. Normal Operation (Non Brewing):
* Only one brew can be stored in “Brew Wait” at a time. To cancel a brew in progress, or a brew waiting, depress the
CANCEL switch: two beeps will sound and the “Brew” light will go out. Water flowing to the brew basket will be stopped immediately, but, if there is already water in the brew basket, it will take a few moments to drip through as coffee.
When the unit is not brewing, the Satellite Brewer maintains the water temperature at the Precise Temperature for Brewing™ (PTB™). The heating element will cycle on and off automatically to maintain this temperature.
the BREW switch will be ignored, (there will be a beep each time it is pressed). A Brew will only be activated or put in Brew Wait when the “Brew” light is off. (If BREW switch is pressed and held 3 seconds during “Brew Wait” the brew will proceed immediately.)
638 p/n 74781 SS-1 Programming Manual
2
OPERATING INSTRUCTIONS (continued)
To view the water temperature on the screen, the Satellite Brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual water temperature will be displayed for 3 seconds.
The Satellite Brewer maintains a count of the number of completed brews for a 7-day period. To access the count, turn the brewer OFF. In the OFF mode, press and hold the CANCEL key for 3 seconds. The current day and brew count will be displayed. Depress the ON/OFF key repeatedly to view each preceding day. When all 7 days have been displayed a 7-day total will be displayed. If you wish to exit the daily brew count before viewing all of the days, press CANCEL key.
To turn the brewer OFF, press the ON/OFF switch: 2 beeps will be heard and the brewer will be turned OFF, indicated by all lights being off, (including any warmer plates on decanter brewers). To turn the brewer ON, press the ON/OFF switch: 2 beeps will sound, all lights will flash once, then the “Power” light will remain on, (the “Heat” light may come on if water temperature is too low).
The factory programmed Satellite Brewer has the automatic timer turned off. To set the automatic timer, refer to the Programming section in this manual, “Time Functions” Menu. If the Automatic Timer feature is programmed off, the brewer can be turned on and off by depressing the ON/OFF switch, as noted above.
* When the Automatic Timer feature is programmed ON the Satellite Brewer will turn on and off automatically, at a programmed time, Monday to Friday; with a separate on and off programmed time schedule for Saturday and Sunday.
* Temporarily Overriding the Automatic On/Off function. While in the automatic timed OFF mode the brewer can be started by depressing the ON/OFF switch. The brewer will remain on until the automatic programmed OFF time, when it will turn off and resume normal automatic timed functioning. Similarly, if turned OFF during the automatic timed ON mode the brewer will remain OFF until the next programmed ON time, when it will turn on and resume normal automatic timed functioning.
If the Satellite Brewer automatic timer is OFF (the factory setting) and power is disconnected, the brewer will start up when power is restored, in the mode it had been in prior to the power disconnect. If the Satellite Brewer has the timer setting ON and power is disconnected, the brewer will start up in the mode that it should be in at the time the power is restored.
638 p/n 74781 SS-1 Programming Manual
5. View Water Temperature in Tank
6. Daily Brew Count
7. ON/OFF – Non Automatic Timer
8. ON/OFF – Automatic Timer Feature
9. Automatic Start-Up in Previous Mode
3
OPERATING INSTRUCTIONS (continued)
10. Brew Volume - Viewing Programmed Brew Volume
11. Changing Brew Volume
12. Clock Battery Backup of Time
13. Changing Day and Time
14. After Hours™
Consult the Programming section in this manual to set the After Hours™ mode. The factory programming has the After Hours™ mode turned OFF.
The Satellite Brewer can have up to 4 different brew volumes. When a volume other than the standard, or first brew volume, is selected, the Satellite Brewer will complete that volume and then automatically reset to the standard, or first brew volume.
Press the required volume key. If a volume is programmed for that key, the volume will be displayed on the screen for 3 seconds and the light above the key will be turned on. If no volume is programmed, the previous light will remain on and the screen will read “no volume prog” (i.e. no volume programmed). When a brew volume other than the 1st, or standard brew volume is selected, the Satellite Brewer will complete the brew then return to the 1st or standard brew volume automatically.
The Satellite Brewer has a battery backup system which will maintain the proper time during power failures, or when the brewer is unplugged (even for very prolonged periods of time). Normally there will not be a need to set the time except for Daylight Saving Time changes, or moving the brewer to different time zones.
To change time, turn the Satellite Brewer off. Press the 2nd key twice followed by the 1st key twice to access the time change mode, (i.e. press CANCEL, CANCEL, BREW, BREW). In the time change mode the screen will read “Day:” followed by the current day setting. Use the 6th key to advance the day, or the 5th key to reverse. When day has been properly set, press the 3rd key. The screen will now read “Time:” with the set time on the screen, the hour and am or pm flashing. Use the 5th key to go back or the 6th key to advance the hour, making sure that the am or pm is correct. When the hour and am/pm is correctly set, press the 3rd key, and the screen will read “Time:” with the set time on the screen, minutes flashing. As previously, use the 5th or 6th keys to adjust the minutes, and press the 3rd key when complete. The Satellite Brewer will return to the off mode. (Changing time can also be done in the regular programming mode.)
The After Hours™ can be programmed to come on from 1 to 6 hours after the last brew. When the Satellite Brewer goes into the After Hours™ mode, the water in the tank will be allowed to drop from the normal brewing temperature and will reheat less frequently – this feature saves energy and extend component life. While in the After Hours mode, the power light will flash continuously. When the BREW switch is pressed the Satellite Brewer automatically reverts back to normal operation, heating the water to the Precise Temperature for Brewing™ (PTB™), before starting the brew. (The power light will be on continuously and the Brew light will flash until the correct water temperature is reached.)
638 p/n 74781 SS-1 Programming Manual
4
OPERATING INSTRUCTIONS (continued)
The Satellite Brewer factory programming has the Countdown Quality Timer™ turned OFF. Consult the Programming section in this manual to activate the Countdown Quality Timer™ feature:
* A Countdown Quality Timer™ is availa ble for the last brew. The timer can be set from 20 to 120 minutes (in 5-minute increments). When a brew is completed, the countdown time will begin. At the end of the selected time there will be two beeps and the volume light will flash continuously until reset. When a new brew is started the timer will be reset automatically.
If a particular brew volume has utilized the pulse or pre-infusion option, that volume will be displayed with an asterisk (*) after the volume. As an example “Volume#2*” would indicate that the second programmed brew volume has utilized the pulse or pre-infusion program options.
If the Keypadlock™ feature is activated, there will be no response by the brewer when the keys are depressed (except for the beep after a key is depressed). To temporarily “unlock” the keypad, press and hold the CANCEL key for 6 seconds. A beep will be heard indicating the keypad is now “unlocked”; a brew can be initiated, etc. The keypad will remain unlocked until the brew is completed, then automatically return to keypadlock™ mode. If a brew is not initiated 60 seconds after “unlocking”, the system will time out and return to the “locked” position.
To view filter statistics, turn the brewer off. Press and hold the 6th key, and touch the 3rd (ON/OFF) key. Total Water Volume (TotalVol.) Touch the 3rd key again to view the filter life (FltrLife:). The percentage of the filter that has been used will be displayed. (If the filter option is used, the filter life volume needs to be entered in the program – see Programming section in this manual, Service & Counters Menu.)
15. Countdown Quality Timer™
16. Pulse or Pre-Infusion Volume Options
To set these features, refer to the Programming section in this manual, Brew Settings Menu.
17. Keypadlock™
To set the feature refer to the Programming section in this manual, Machine Settings Menu. This feature is OFF in the standard factory settings.
18. View Filter Statistics:
638 p/n 74781 SS-1 Programming Manual
5
PROGRAMMING INSTRUCTIONS
V
CONTROL PANEL KEYS
Brew comple te
BREW
HEAT
POWER
CAUTIO N
HOT LIQUID
OLUMES
1st key
2nd key
3rd key
KEY #
From
Left
1 2 3 4 5 6
BREW CANCEL ON/OFF 1/2 GALLON VOLUME 1 GALLON VOLUME 1-1/2 GALLON VOLUME
BREW
Volume
CANCEL
KEY NAME
ON
OFF
LIFT FOR
HOT WATER
6th key 5th key 4th key
PROGRAM FUNCTION
MENU Advance to next menu EXIT Programming Mode ITEM Select & Advance to next item
Used for Pulse/Pre-infusion only
DECREASE (-) Value INCREASE (+) Value
638 p/n 74781 SS-1 Programming Manual
6
Loading...
+ 16 hidden pages