Bloomfield Integrity 8746 Owner's Manual

Page 1
OWNER'S MANUAL
BLOOMFIELD INDUSTRIES
INTEGRITY™
OPERATING INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
and
PARTS LIST
70473
8746-M
Brewing Systems
ICED TEA
2 ERIK CIRCLE, P.O. BOX 280
VERDI, NEVADA 89439
FAX (800) 356-5142
Page 2
INDEX
INTRODUCTION TO THE UNITS ............................................……………. ...3
UNIT SET UP ..................................................................................………..…3& 4
BREWING OF TEA..................... ..................... .........................……………....4
TEABREWERADJUSTMENTS……………………………………………………4
TIMER/VOLUME ADJUSTMENT
BREWER WATER VOLUME ADJUSTMENT……………………………………5 RATIO CHANGE
PARTS LIST .................................... ............................................……………..6 & 7
EXPLODED VIEW OF BREWING UNIT .........................................……………8
EXPLODED VIEW, DISPENSER UNITS………………………………………….9
PARTS LIST, DISPENSER UNITS.......... .......................................……………9
SOLENOID EXPLOSION & PARTS LIST ......................................……..……..10
WIRING DIAGRAM................... ............. .....................................……………..10
WARRANTY .................................... ......................................………………….11
The INTEGRITY BREWERS have been designed with adjustment flexibility to cover a wide spectrum of customer needs. Adjustments on the running thermostat and inlet timer are simple adjustments easily accomplished by the purchaser, but NOT COVERED UNDER ANY WARRANTY SERVICE AGREEMENT. Brewers must be installed in accordance with installation instructions in the owner's manual for the warranty to be valid.
WARNING:
DO NOT PLUG IN OR ENERGIZE THIS UNIT UNTIL INSTALLATION INSTRUCTIONS ARE READ AND FOLLOWED.
PAGE 2
Page 3
INTRODUCTION TO THE UNITS
This manual covers the six (6) gallon tea brewer and the six (6) gallon tea dispenser.
1.
The Model 8746 is the tea brewing section only and does not have a storage and/or dis­pensing reservoir as part of the unit.
2. The Model 8806 is the six (6) gallon stainless steel reservoir to hold the finish brew.
All brewers are shipped from the factory with:
1. A Stainless Steel Brew Funnel.
2. A Wire Grid to support the filter paper and
3. A 25 pack of Filter Papers, and
4. A Water Line Filter.
Electrical Requirements:
Plumbing Requirements:
Unit requires a power source capable of supplying:
115 Volt, AC., 60 Hertz, Single Phase, 15 Amp.
Service.
Unit must be installed on a water line with a flowing pressure between 20 PSI and 90 PSI. If water pressure does not fall into this range or varies greatly a pressure regulator should be installed
The unit is shipped from the factory with a 3-wire,
2-pole polarized power cord and cap attached.
in the water supply line.
SET UP
1. Carefully remove brewer and tea reservoir from cartons.
2. Set brewer in operating location and level, using adjustable legs.
3. Connect water line to 1/4” flare fitting on back of unit. Turn on water and check for leaks.
4. Make sure tank heater switch on front panel is in
OFF
position.
Bottom
portion of switch
rocker should be pressed in.
5. Plug unit into 110-120 Volt grounded outlet, fused at 15 Amps.
6. Place reservoir under brewer.
7. Press momentary brew switch, to initiate brewing cycle.
NOTE: Water will immediately begin to
flow from dilute water spout
CAUTION: During this initial fill cycle, check level of water in reservoir. Before initiating another brew cycle, the reservoir must be emptied to prevent overfilling and flooding.
8. Repeat brewing cycles until water begins to
flow from spray disc.
Page 3
Page 4
9.
After end of final cycle, turn tank heater switch to ON position - top portion of
7
switch rocker pressed in.
10.
When tank water is up to proper temper­ature, the green READY TO BREW light will be lit.
NOTE: During the initial
heatup,
some water will drip from spray disc. This is normal.
11.
Discard all water in reservoir and brew one (1) additional cycle. CAUTION! Water dispensed from spray disc will be HOT! Watch out for splashing. If water level needs to be adjusted, see tea brewer
adjustments.
12.
Discard water in six gallon dispenser, place brew-through cover on dispenser then reposition empty dispenser on brewer.
13.
Place filter and tea in brew chamber. Slide brew
chamber into place on brewer.
14.
Brewer is now ready for brewing tea.
BREWING
1.
Place filter paper in brew chamber and add
5.
tea. Slide brew chamber into rails, pushing
it to full back stop location.
2.
Check to see that reservoir with cover is pro­perly located to accept dilute water spout
flow and brew chamber drain flow.
6.
3.
Press brew switch to initiate brewing cycle.
4.
Dilute water will begin to flow immediately
7.
into reservoir. Brewed tea will begin to flow
from brew chamber in about 20 to 30
seconds, and continue for approximately 10 to
12 minutes. Make sure drip-out is complete
before removing brew chamber.
If for any reason there is a need to stop the brewing cycle before its completion, press the
“Brew Stop” switch. This stops water flow to the brew chamber and the flow from dilute water spout. The timing cycle is also cancelled and timer resets to start.
Check level in reservoir - finished brew should be approximately 1” from top edge.
Brewed tea is now ready for use. If a change in strength is desired, add or reduce tea, to taste . preference and continue for approximately 10 to 12 minutes. Make sure drip-out is complete before removing brew chamber.
The brewer is factory adjusted to produce six (6)
gallons of tea in a 1-5
brew
to dilute water ratio.
Should it become necessary to adjust for total
volume, follow these steps below.
3.
4.
TIMER ADJUSTMENT
(Total Volume Change)
1. Unplug unit.
5.
2.
Remove four (4) screws (2 on each side of cover) lift off cover to expose timer.
TEA BREWER ADJUSTMENTS
To brew more tea, turn knob slightly clockwise; to
brew less, turn slightly counterclockwise.
Plug unit in and cycle unit. Check for required volume - repeat if needed, until desired volume
is attained. Replace cover on brewer.
Normal delivery should be six (6) gallons (766 ounces) of water.
Do not readjust setting of needle valve!
Page 4
Page 5
BREW WATER VOLUME ADJUSTMENT
(Ratio Change)
1.
Follow steps 1 through 4 in Timer Adjustment Procedure.
2.
Turn the handle of the needle valve clockwise
IN (facing the valve stem and handle) to in­crease the ratio. This causes more water to be diverted to the dilute flow, and less to the brew. A counter-clockwise OUT rotation will do the opposite.
3.
Adjustments must be made in 1/4 turn incre­ments to avoid drastic changes. One (1) full turn in either direction is the maximum ad­vised. Average factory setting is two full turns counter-clockwise from a fully closed position.
NEEDLE VALVE
FOR BREW RATIO
-
CHANGE
SOLENOID
VALVE
-
4.
Water flow from spray disc and dilute spout should be measured separately to determine that the desired ratio has been achieved.
NOTE: If flow from spray disc is very weak and slow in starting, the ratio adjustment made is starving the brew water flow.
If, however, water flows from the vent tube, located next to the spray disc assembly, then
the ratio of water for brewing is too great. It is
advisable that the spray disc and vent tube be
viewed after an adjustment has been made.
5.
After desired adjustments have been made, a complete brew should be made to insure quality of finished product.
TOP VIEW WITH
COVER REMOVED
FRONT OF BREWER
Page 5
-
THERMOSTAT
HIGH LIMIT
-
CONTROL
ADJUSTMENT
Page 6
REPLACEMENT PARTS LIST - OF BREWING UNIT
MODEL 8746
REF. NO.
PART NO.
DESCRIPTION
1 2 3 4
6 7
8 9
10 11 12 13 14 15 16 17
19
20 21
23 24 25 26 27 28
29 30 31 32 33 34 35
36 37
1
38 39
40 41 42 44
45 46 47
49
50
8543-52
#08x3x8 B.PN.P.SS
8746-12
BASIN TOP WELDED
7200-6X
#O8-32 X 5/16 PN.P.SS
8043-5
HOLD DOWN STRAP ASSY
8043-47
#10-32 X 1 PN.P.SS
8543-69
SHORTY BUSHING-HEYCO TUBE, CONNECTOR
8746-38
WATER OUTLET TUBE
8043-13
SPRAY ELBOW
8746-5 1
12 MINUTE TIMER 120V
8746-13
BASIN WELDED ASSY
8706-9
WIRE RACK
8707-3
#1O-32 X 5/16 HEX HEAD
8707-2
BASKET HANDLE
88 12-760
BREW CHAMBER STAMPED
8543-42
SPRAYHEAD GASKET
8543-44
SPRAYER DISC
8718-31
PILOT LT. GREEN, 125V
8707-28 BREW SWITCH, ROCKER 8812-79 SWITCH, MOMENTARY NC 8707-34 SWITCH, LIGHTED 12OV 8543-23 TINNERMAN NUT 8746-22 BODY WELDED ASSY 8746-16
WATER SPOUT ASSY
88 12-56
MALE HOSE BARB FTG.
8812-15
HOSE 1-1/2” LONG
88 12-54
FTG. NYLON Y 1/4 X 3/16
8746-59
SPOUT CONN. HOSE 3# 8710-10 NUT 7/16-20 X 1/8 88 12-57
UNION 1/4X 1/4M FLR. 8810-70
WASHER-RESTRICTOR 851 4-26
NEEDLE SEAT VALVE 8746-52
TANK INLT. TUBE ASSY 8812-55 PIPE TEE 8596-1240
1/4 x 1/8 FPT. REDUCER
8706-20
VENT TUBE 8043-15
VENT TUBE 8541-120
SOLENOID VALVE, 12OV 8706-160
CONNECTOR 8746-50
TUB. ASSY. VALVE INLT 8746-34
WATER TANK, 6 GAL TEA 7510-22
NUT, 1/2-24
8812-70
WASHER-BACK-UP
8812-41
OUTLET ELBOW ASSY
8043-506
#8-32 HEX ACORN NUT
8746-36
FILL TUBE ASSEMBLY
9102-9
HTG. ELEM, 12OV, 1675W
8551-53
S.S. WASHER
8942-33
GASKET, FILL TUBE
Page 6
Page 7
REPLACEMENT PARTS LIST
(continued)
REF. NO.
PART NO.
DESCRIPTION
51
8043-30
HTG ELEMENT GASKET
52
8710-10
NUT 7/16-20 X 1/8
53 8043-12
TANK COVER GASKET
54
8043-28
NUT, HEX /2-20 2B
55
8512-41
SEAL WASHER
57
8512-51
THERMOSTAT - R. SHAW
59
88 12-34
TANK COVER. WELDED ASSY
60
8043-83
HI-LIMIT THERMOSTAT
61
8746-28
LEG (LEFT)
62 8746-21
BACK PANEL
63
8942-92
NUT, #8-32 KEPS HEX
65
8746-30
TEA 6 G STAND BASE
66 D 20002-3
#10-32 X 5/16 PN.P.SS
67
8033-56
LEG LEVELER CAP
68
8033-55
LEG LEVELER
69 88 12-47
FITTING, NYLON Y3/16
70
8746-27
END CAP FOR LEG
71
8746-29
LEG (RIGHT)
72
35-210
CORD, GRIP, HEYCO LG
73
8942-48
CORD & CAP - (12OV)
74
8812-73
BREW BASKET CLIP
75
8812-80 BREW CHAMBER ASSY
76
7506-39
#8-32 X 1/2
77
3-100
SCREW 6-32 X 1/4 R.H.
ITEMS NOT SHOWN
PART NO. DESCRIPTION
8747-8
BASIN FRONT LABEL (LUZIANNE) 8541-120JS SOLENOID REPAIR KIT 8541-120KS SOLENOID OVERHAUL KIT
Page 7
Page 8
EXPLODED VIEW - OF BREWING UNIT
/--
MODEL 8748
Page 9
d
IO
EXPLODED VIEW
FOR
RESERVOIR AND DISPENSER
SECTIONS OF MODEL NO. 8808
9
‘1’
85
1
2
MODEL NO. 8806
Model Without Slght Glass
REPLACEMENT PARTS LIST
REF NO.
PART NO.
DESCRIPTION
1
6600-50
2
8600-28
3 6600-12 4 6600-6 5
6600-15
6
6700-25 L
7 6600-26 6
6600-27
9
6942-33
10
6606-l
11
6606-5
12
66061
Nut Flat Washer Nylon Washer
Siynk
Faucet ONLY, Plastic Seat Cup
“c”
Ring Wing Nut Gasket
VS%l
ClY4er
Label (“Luzianne” _ not shown)
Pago 9
Page 10
ADDITIONAL SERVICE INFORMATION
COLD WATER ENTRANCE SOLENOID VALVE PART NO. 8541-120
,ton*irtr Of hl”F and Flow Control,
SOLENOID VALVE REPLACEMENT PARTS
(For Black Coil Valve)
INo Kit Parts Sold Separately)
(1)
8541.120CS
Coil Assembly 120V.
(2) 8541-120K
Solenoid Repair Kit Vacuum
Pat
consists of:
(2A)
Spring
(28)
Plunger
(2C)
Seal Ring
(3)
8541-120JS
Solenoid Repair Kit
Vacuum
Pat
consists of:
(2A)
Spring
(28)
Plunger
(2C)
Seal Ring
(20) Service Wrench
(4)
8541-120KS
Solenoid Overhaul Kit
Vacuum
Pat
consists of:
@A)
Spring
(28) Plunger (2C)
Seal Ring (20) Service Wrench
(3A)
Flow Control
(5)
8541.12OF
(3A)
Flow Control
(6) 8541-120WS (2D)
Service Wrench
WIRING DIAGRAM ICE TEA BREWER
MODEL 8746
Page 10
Page 11
WARRANTY
For a period of one (1) year from date of installa-
tion, all defective parts on Bloomfield equipment will be replaced free of charge, providing parts did
not become defective through accident, neglect,
improper installation, mishandling or damage in transit. The service necessary to replace these defective parts will also be free of charge, pro­vided this service is performed by an authorized
BLOOMFIELD service station, wherever author-
ized service is available.
BREWER WARRANTY IS VOID IF:
Other than genuine Bloomfield replacement parts
are used. Brewer is plugged into voltage other than speci-
fied on serial plate. Tank heating element is energized before water
tank is filled.
Recommended Bloomfield servicing procedures
are not followed.
How to Order-
Individual users and owners must order replace­ment parts thru their distributors or the local authorized service station.
Terms - Prices, terms, designs, materials, weights, specifications and dimentions for equip­ment or parts are subject to change without notice.
Service Information - To obtain service assistance in addition to that contained in this manual, call Bloomfield’s toll free number (800) 621-8556.
Be prepared to give the Model and Serial Numbers of your brewer, as well as the problem and the trouble-shooting steps already taken, to the ser­vice technician when calling for assistance.
=BLOOMFIELD
BLOOMFIELD INDUSTRIES
2 ERIK CIRCLE
P.O. BOX 280
VERDI, NV 89439
FAX (800) 358-5142
PRINTEO IN U.S.A.
-
page 11
Page 12
1
h
/
2
FIGURE A
INSTALLATION INSTRUCTION
FOR BASE EXTENDER KIT #83334
FOR MODEL 8748
TEA BREWER
ELECTRICAL SHOCK HAZARD: Turn off the Tank Heater Switch and disconnect
power supply to Brewer before removal of any panel. Electrical shock will cause
-*
death or serious Injury.
CAUTION:
Wait until the water in the tank has cooled down to room temperature
before Installing this Kit. Failure to comply will cause severe burns.
STEP 1: Remove the Screws from the Back Panel (ITEM 1). Remove the Back Panel. (FIG A) STEP 2: Drain Tank. STEP 3: Set the Brewer on It’s side and remove the Bottom Base and Legs (ITEM 2). (FIG A) STEP 4: Locate the Base Extender (ITEM 4) and the Speed Nuts (ITEM 3) included in the Kit.
Push the Speed Nuts onto the top and bottom flanges at each hole location. (FIG B) STEP 5: Orient the Base Extender (ITEM 4) with the seam to the rear, the Bottom Base (ITEM 5)
. and the Bottom Panel (ITEM 6) included in the Kit as shown on the exploded view (FIGURE B). Make sure all the holes line up. Mount the Extender first, then the Base and Bottom Plate with the Screws included in the Kit.
STEP 6: Replace the Back Panel (ITEM 1). FOLLOW THE INITIAL INSTALLATION INSTRUCTION IN THE 8746 MANUAL FOR PROPER BREWING.
-
12
Part Number 73332
Loading...