Bloomfield HT-500AF Installation Instructions Manual

ELECTRICAL
INSTALLATION INSTRUCTIONS
DROP-IN BAIN MARIE STYLE HEATED TANK
MODEL HT-500AF WITH WATER FILL
WATTSVOLTSMODEL
HT-500AF
240HT-500AF
UNITS ARE SHIPPED THREE PHASE AND ARE FIELD CONVERTIBLE TO SINGLE PHASE
70 1/2 (1791)
16 7/8
(429)
4500208 6000
3 1/8
(79)
AMPS PER LINE 3 PHASE
13.0
4 1/8 (105)
5
(127)
18.7
21.7
22 7/8
(581)
AMPS
L3L2L1
8.7
10.0
SINGLE
PHASE
25.015.0
PRODUCT DIMENSIONSCUTOUT DETAILS
3 7/8
(98)
1/4 NPT WATER FILL CONNECTION
FIELD WIRING GAUGE
3 PHASE 1 PHASE
10 AWB Cu21.7
67 3/4
(1721)
71 1/2 (1816)
(457)
6 1/4
(159)
18
8 AWB Cu 8 AWB Cu
19 7/8
(505)
9 3/4 (248)
CONTROL PANEL WITH FLEXIBLE CONDUIT
TEMP.
RATING
90°C 90°C10 AWB Cu
23 5/8
(600)
1 INCH NPT DRAIN WITH BALL VALVE
INCHES
(MM)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. Required installation clearances: Wooden and Metal Installation: DO NOT install closer than 4 1/8 inches to front wall, 1 inch to back and side walls, and 6 3/4 inches to surface below the unit.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is recommended that a baffle be placed 8 1/2 inches below the unit to avoid contact with elevated temperatures.
4. For water and waste connections: This appliance is to be installed to comply with the applicable federal, state or local plumbing codes.
TO FABRICATE:
1. Lay out "cutout" dimensions on countertop and front apron.
2. Lay out and fabricate control panel holes in counter apron using the control box as a template.
3. Cut out holes.
TO INSTALL:
IMPORTANT - DO NOT disconnect lead wires from the Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through the countertop cutout, then through the apron cutout. Lower modular section into countertop cutout and position. RECOMMENDATION: Before final seating of modular section to countertop, apply a bead of silicone adhesive/sealant to the underside of gasket supplied on the mounting flange.
2. From underneath, insert screwdriver into slots in Wellslock frame and twist ears outward (clockwise) as required to secure flange tightly to countertop.
3. Mount Control Box to apron cutout as shown in drawing.
4. Mount Control Panel onto electrical box using the screws supplied.
WELLS/BLOOMFIELD * VERDI, NV
MINIMUM CLEARANCE REQUIRED
FROM UNIT TO THE NEAREST SURFACE
FRONTBOTTOMSIDEBACK
11
(25)
WARMER FLANGE
GASKET
SCREWDRIVER
TO PLUMB:
1. A drain with valve is supplied on all units. Location of the valve handle is at the discretion of the fabricator (see drawing).
2. Connect 1" drain connection to a suitable drain line.
3. Connect 1/4 NPT flexible water fill line to solenoid valve in outlet box, maximum pressure 120 PSI, maximum temperature 120°F.
COUNTERTOP
MASTER CONTROL PANEL
WELLSLOK
6 3/4
(171)(25)
1/4 NPT WATER FILL CONNECTION
4 1/8
(105)
TO WIRE:
1. Final connection is accomplished by bringing proper power supply leads (see 'WIRING REQUIREMENTS' label) through conduit knockout to terminal block supplied within the Master Control Panel. Check nameplates for voltage and phase.
NOTES:
BAIN MARIE STYLE HEATED TANKS ARE DESIGNED FOR WET OPERATION ONLY.
A BACK FLOW PREVENTER IS INCORPORATED IN THE WATER FILL LINE BETWEEN SOLENOID VALVE AND PAN. LOCAL CODES MAY REQUIRE AN ADDITIONAL VACUUM BREAK DEVICE, NOT PROVIDED BY WELLS.
INSTALLATION MUST MEED LOCAL PLUMBING AND ELECTRICAL CODES.
301779-4 REV (-)