Bloomfield HT-300 Installation Instructions Manual

ELECTRICAL
HT-300 HT-300 240
208 2700
3600
42 1/2 (1080)
13.0
15.0 SINGLE
3 1/8
(79)
SINGLE 14 AWB CU 90°C
22 1/2
(572)
4 1/8 (105)
FIELD
GAUGE
3 7/8
(98)
TEMP.
RATING
90°C14 AWB CU
PRODUCT DIMENSIONSCUTOUT DETAILS
39 3/4
(1010)
43 1/2 (1105)
INCHES
(MM)
6 1/4
(159)
INSTALLATION INSTRUCTIONS
DROP-IN BAIN MARIE
STYLE HEATED TANK
MODEL HT-300
23 5/8
19 7/8
(600)
(505)
5
(127)
4 7/8 (124)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. Required installation clearances: Wooden and Metal Installation: DO NOT install closer than 4 1/8 inches to front wall, 1 inch to back and side walls, and 6 3/4 inches to surface below the unit.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is recommended that a baffle be placed 8 1/2 inches below the unit to avoid contact with elevated temperatures.
TO FABRICATE:
1. Lay out "cutout" dimensions on countertop and front apron.
2. Lay out and fabricate control panel holes in counter apron using the control box as a template.
3. Cut out holes.
TO INSTALL: IMPORTANT - DO NOT disconnect lead wires from the Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through the countertop cutout, then through the apron cutout. Lower modular section into countertop cutout and position. RECOMMENDATION: Before final seating of modular section to countertop, apply a bead of silicone adhesive/sealant to the underside of gasket supplied on the mounting flange.
2. From underneath, insert screwdriver into slots in Wellslock frame and twist ears outward (clockwise) as required to secure flange tightly to countertop.
3. Mount Control Box to apron cutout as shown in drawing.
4. Mount Control Panel onto electrical box using the screws supplied.
9 3/4 (248)
5 7/8
(149)
CONTROL PANEL WITH FLEXIBLE CONDUIT
1 INCH NPT DRAIN WITH BALL VALVE
CLEARANCES
MINIMUM CLEARANCE REQUIRED
UNIT TO THE NEAREST SURFACE
FRONTBOTTOMSIDEBACK
11
(25)
WARMER FLANGE
GASKET
WELLSLOK
SCREWDRIVER
COUNTERTOP
TO PLUMB:
1. A drain with valve is supplied on all units. Location of the valve handle is at the discretion of the fabricator (see drawing).
2. Connect 1" drain connection to a suitable drain line.
TO WIRE:
1. Final connection is accomplished by bringing proper power supply leads (see 'WIRING REQUIREMENTS' label) through conduit knockout to wire leads supplied within the Master Control Panel. Check nameplates for voltage and phase.
MASTER CONTROL PANEL
6 3/4
(171)(25)
NOTES:
BAIN MARIE STYLE HEATED TANKS ARE DESIGNED FOR WET OPERATION ONLY.
INSTALLATION MUST MEED LOCAL PLUMBING AND ELECTRICAL CODES.
4 1/8
(105)
WELLS/BLOOMFIELD * VERDI, NV
301765-2 REV (-)