Bloomfield 9311, 9311-SS1 User Manual

10 Sunnen Drive
St. Louis, MO 63143
telephone: 800-807-9054
fax: 314-781-2714
www.wellsbloomfield.com
BLOOMFIELD INDUSTRIES
OWNERS MANUAL
for
SS1 - SERIES
SATELLITE
COFFEE BREWERS
with
ELECTRO-MECHANICAL
CONTROL
and
INTERNALLY HEATED
SATELLITE SERVER
MODEL:
9311
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 9311 Satellite Brewer
p/n DD-74415 Rev. I M661 090724
w/optional
3902 Drip Tray
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
SHIPPING DAMAGE CLAIMS PROCEDURE
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates; conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
All electrical equipment manufactured by WELLS BLOOMFIELD is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, decanters excluded.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Wells Bloomfield for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific limitations are shown below (Additional Warranty Exclusions). Wells Bloomfield Authorized Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory or your food service equipment dealer; or, for information and other details concerning warranty, write to:
Service Parts Department
Wells Bloomfield, LLC 10 Sunnen Dr. P.O. Box 430129 St. Louis, MO 63143 USA
Phone: 1-800-807-9054 Fax: 1-800-396-2677
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted for ninety (90) days from date of purchase on non- warranted equipment.
Any use of non-genuine Wells Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
xi
TABLE OF CONTENTS
Thank You for purchasing this WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 4 AGENCY APPROVAL INFORMATION 4 INSTALLATION 5 OPERATION 7 CLEANING INSTRUCTIONS 9 SERVICING INSTRUCTIONS 11 TROUBLESHOOTING SUGGESTIONS 16 EXPLODED VIEW 18 WIRING DIAGRAM 20 SATELLITE 21
Wells Bloomeld appliance.
Proper installation, professional
operation and consistent
maintenance of this appliance will
ensure that it gives you the very
best performance and a long,
economical service life.
This manual contains the
information needed to properly
install this appliance, and to use,
care for and maintain or repair the
appliance in a manner which will
ensure its optimum performance.
SPECIFICATIONS
MODEL VOLTS WATTS AMPS POWER
9311 120/208 - 240 VAC
60 Hz 1ø
3200 - 4280W 15.4 - 17.8A 3-wire required
(L1, L2, Neut) + Gnd
Cord NOT Provided
CORD
1
FEATURES AND OPERATING CONTROLS
Fig 1. SS-1 Satellite Brewing System Features & Operating Controls
2
FEATURES AND OPERATING CONTROLS (continued)
Brewer
Adjustable Legs
Bypass Nozzle Connector
Hot Water Faucet Nameplate
Control Panel
Brew Switch Ready to Brew Indicator Stop Switch Satellite Indicator
Tank Heat Switch Volume Selector Switch
Brew Chamber
Brew Chamber Wire Rack
Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer.
Dilution water ows into satellite server from here.
Connects to satellite. Allows satellite heater to be energized. Allows brewer to sense that a satellite is in place.
Hot water dispensed here. Lists manufacturer, model and serial number.
Also lists voltage and wattage rating of brewer.
Press to start a brew. Glows when water in tank is up to temperature. Press to cancel a brew in progress. Glows when a satellite is properly installed.
Flashes at end of Quality Time. Applies power to tank heater element. Glows when ON. Allows selection if 1/2 gallon, 1 gallon or 1-1/2 gallon brew.
Holds coffee grounds during brew cycle.
Holds paper lter and coffee grounds in proper position in brew
chamber.
Satellite
Brew-Thru Lid
Connector
Handles Nameplate
Serving Faucet Sight Glass
Drip Tray (optional)
Allows entry of brewed coffee and dilution water into satellite. Minimizes splashing in the event satellite is tipped.
Connects to brewer. Allows heater to be energized. Allows brewer to sense that a satellite is in place.
Allow the satellite to be safely carried. Lists manufacturer, model and serial number.
Also lists voltage and wattage rating of satellite. Fresh coffee dispensed from satellite here. Check the level of coffee remaining here.
Optional drip tray catches drips and spills from serving faucet. Easily removed for cleaning.
3
GENERAL INFORMATION AND PRECAUTIONS
E9253
E9253
STD 4
This appliance is intended for use in commercial
WARNING:
SHOCK HAZARD
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel that requires the use of tools. Failure to follow this warning can result in severe electrical shock.
CAUTION:
BURN HAZARD
Surfaces of the brewer and brew chamber may be hot to the touch and can cause burns on contact.
establishments only. This appliance is intended
coffee, for human consumption. No other use is recommended or authorized by the manufacturer or its agents.
Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.
Surfaces of the brewer, brew chamber and satellite can be hot to the touch, and may cause burns on contact.
Disconnect the brewer from electrical power before performing any maintenance or servicing.
DO NOT submerge satellites in water. DO NOT splash or pour water over, onto or into any controls,
control panel or wiring. Any procedure which requires the use of tools must be performed
by a qualied technician.
This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware.
to brew hot beverage, specically
AGENCY APPROVAL INFORMATION
This dual satellite brewing system is listed under E9253 and listed under E9253.
This dual satellite brewing system meets NSF Standard 4 only when installed and maintained per the instructions in this manual.
4
INSTALLATION INSTRUCTIONS
SCREW INTO BREWER FRAM E
ADJUST FOR HEIGHT
ATTACH RUBBER FEET
INSTALL LEGS
The brewer is provided with adjustable legs and rubber feet. Be sure the legs are securely screwed into the base of the brewer, and that the rubber feet are properly installed.
LEVEL THE UNIT The adjustable legs allow the brewer to be leveled. Set the brewer
in its ultimate operating location and check for level with a spirit level Adjust the brewer for level from front-to-rear, and from side-
to-side. Be sure all four feet rest rmly on the counter.
PLUMBER’S INSTALLATION INSTRUCTIONS IMPORTANT:
This equipment must be installed in accordance with the Basic
Plumbing Code of the Building Ofcials and Code Administrators
International (BOCA), and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). Also, this equipment installation must comply with all local plumbing codes and ordinances.
IMPORTANT:
Brewer must be installed on a water line with a full-ow pressure
between 20 psi and 90 psi. NOTE: If water pressure varies greatly, or exceeds 90 psi at any
time, a water pressure regulator must be installed. Plumbing installer must supply the regulator.
Brewer must be connected to a potable water supply. Bloomeld
recommends not less than 1/4” copper tubing for installations of 12’ or less, and not less than 3/8” copper tubing for installations exceeding 12’. Brewer must be connected to a COLD water line.
NOTE: DO NOT use a saddle tap for this water line connection. A shut-off valve must be installed between the main water supply
and the brewer. Plumbing installer must supply the shut-off valve. A 1/4-turn ball valve is recommended.
Bloomeld highly recommends the use of the provided water
strainer to help prevent deposits in the brewing system.
NOTE:
To enable the installer to make a quality installation and to minimize installation time, these tests and suggestions should be completed before the actual installation is begun.
CAUTION:
UNSTABLE EQUIPMENT HAZARD
Rubber feet must be installed on each leg of the brewer. Legs must be adjusted so that all four
feet rest rmly on the counter.
Failure to properly install the feet can result in movement of the brewer, which can cause personal injury and/or damage to the brewer.
CAUTION:
SHOCK HAZARD
Brewer must be properly grounded to a reliable earth ground to prevent possible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
Fig. 3 Water Line Installation
Flush the water line before connecting to the brewer.
Fig. 2 Adjustable Legs
5
INSTALLATION INSTRUCTIONS (continued)
CAUTION:
SHOCK HAZARD
Brewer must be properly grounded to a reliable earth ground to prevent possible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
IMPORTANT:
Initial set-up must be performed
by a qualied installer or qualied service technician.
Improper set-up will damage the brewer and void the warranty.
IMPORTANT:
Complete water line installation before connecting brewer to electrical power.
MAKE SURE THE FRONT PANEL “TANK HEATER” SWITCH IS IN THE OFF POSITION BEFORE CONNECTING BREWER TO ELECTRICAL POWER.
DO NOT turn the TANK HEATER switch on until the
water tank is lled. Heating
element must be completely submerged in water at all times. Damage to the brewer caused by operating the heating elements dry is NOT covered by warranty.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
Refer to Electrical Specications, page 1.
Brewer requires a dedicated single-phase circuit: Model 9311 120/240 Volt AC, 50/60 Hz 4-Wire 20 Amps.
INITIAL SET-UP INSTRUCTIONS
Plumber’s and Electrician’s installation procedures must be completed before proceeding with the set-up.
Be sure all electrical connections are secure, and that all plumbing connections are secure and leak-proof.
1. CHECK BREWER FOR PROPER CONFIGURATION Make sure spray disk gasket is in place INSIDE of spray
head. Make sure spray disk is properly installed. Check hot water faucet for proper operation.
2. FILL WATER TANK Be sure TANK HEATER switch is OFF, then connect brewer
to electric power. Insert an empty brew chamber under the brew head. Place
an empty satellite in position. Turn the VOLUME SELECTOR
switch to 1 GAL.
Press START. Water will begin lling the tank. Repeat until
water ows from the brew chamber. For initial start-up, tank
requires two or more 1 GAL. cycles to ll.
3. CHECK HEATING Press TANK HEATER switch ON. Water in tank will heat
to brewing temperature in approximately 30 minutes. When
the water temperature reaches the brew temperature set
point, the READY-TO-BREW light will glow. Hold a suitable container under the hot water faucet, then
open the faucet . Continue drawing water until all trapped air
is expelled.
6
OPERATING INSTRUCTIONS
Fig. 4 Control Panel
BREWING COFFEE Prepare the Brew Basket:
Make sure the wire rack is properly installed in the brew chamber.
Insert one (1) Bloomeld paper lter into the brew chamber.
Make sure the lter is properly supported by the wire rack.
Add a measured amount of grounds to the brew basket. Recommendations (may vary, depending on type of coffee
and personal taste preferences): To brew 1/2 gallon, use 2.25 oz (64 gm) of coffee To brew 1 gallon, use 4.50 oz (128 gm) of coffee To brew 1-1/2 gallon, use 8.40 oz (240 gm) of coffee Gently shake the basket to level the grounds.
Slide the brew chamber under the brew head.
Insert the Satellite:
Brewer will not brew unless a satellite is properly installed. Slide satellite under the brew chamber until it is
fully seated. The SATELLITE indicator will glow when the
satellite is properly positioned.
Select Brew Volume: Turn VOLUME SELECT switch to 1/2 GAL, 1 GAL or
1-1/2 GAL. Start the Brew:
Press the START switch. NOTE: The brew can be cancelled at any time by pressing
the STOP switch. At the end of the brew, be sure all water has stopped dripping
before removing the brew chamber. When the READY-TO-BREW light comes on, the brewer is
ready to run another brew cycle.
Empty the Brew Basket:
Discard the grounds and the paper lter. Rinse the brew
chamber under clear water.
Fig. 5 Brew Basket
NOTE: Brewer will not brew unless a satellite is properly installed.
NOTE: The brew can be cancelled at any time by pressing the STOP switch.
NOTE: DO NOT turn the VOLUME SELECT switch during a brew. This will disrupt the brew cycle.
CAUTION:
BURN HAZARD
Basket and contents are hot to the touch and may cause burns on contact.
7
Loading...
+ 19 hidden pages