All electrical equipment manufactured by BLOOMFIELD
INDUSTRIES is warranted against defects in materials and
workmanship for a period of one year from the date of original
installation or eighteen (18) months from the date of shipment
from our factory, whichever comes first, and is for the benefit
of the original purchaser, except that:
a. airpots carry a 30 day parts warranty only.
b.dispensers; i.e., tea and coffee carry a 90 days parts
warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY
EQUIPMENT MANUFACTURING CORPORATION SHALL
NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY
CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by
an Authorized Service Agency that the equipment has been
modified, misused, misapplied, improperly installed, or
damaged in transit or by fire, flood or act of God.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers,
overload protectors, or fuse replacements unless
warranted conditions are the cause.
2. All problems due to operation at voltages other than
specified on equipment nameplates; conversion to
correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in
accordance with electrical code requirements and
wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include
such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is
considered a preventative maintenance function and is
not covered by warranty.
It also does not apply if the serial nameplate has been
removed or unauthorized service personnel perform service.
The prices charged by Bloomfield Industries for its products
are based upon the limitations in this warranty. Seller’s
obligation under this warranty is limited to the repair of defects
without charge by a Bloomfield Industries Authorized Service
Agency or one of its sub-agencies. This service will be
provided on customer’s premises for non-portable models.
Portable models (a device with a cord and plug) must be
taken or shipped to the closest Authorized Service Agency,
transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific
limitations are shown below (Additional Warranty Exclusions).
Bloomfield Industries Authorized Service Agencies are located
in principal cities.
This warranty is valid in the United States and void elsewhere.
Please consult your classified telephone directory or your food
service equipment dealer; or, for information and other details
concerning warranty, write to:
Phone: (775) 689-5700 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied
with each machine. Those miscellaneous adjustments
noted are customer responsibility. Proper attention will
prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an
authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours.
Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted
for ninety (90) days from date of purchase on non warranted equipment. Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered
warranty.
12. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technicians ability
to perform services are not covered by warranty.
This includes institutional and correctional facilities.
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by
skilled personnel before leaving the factory.
Upon acceptance of this shipment, the transportation
company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill
or express receipt, and that the note of loss or damage
is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3.CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and file
“CONCEALED DAMAGE” claim with them. This
must be done within fifteen (15) days from the date the
delivery was made to you. Be sure to retain the
container for inspection.
Bloomfield Industries cannot assume liability for damage or
loss incurred in transit. We will, however, at your request,
supply you with the necessary documents to support your
claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi
SPECIFICATIONS 1
FEATURES & OPERATING CONTROLS 2
PRECAUTIONS & GENERAL INFORMATION 4
AGENCY APPROVAL INFORMATION 4
INSTALLATION 5
OPERATION 7
CLEANING INSTRUCTIONS 10
PROGRAMMING INSTRUCTIONS 12
TROUBLESHOOTING SUGGESTIONS 17
SERVICING INSTRUCTIONS 18
EXPLODED VIEWS 20
WIRING DIAGRAM 24
SATELLITE 25
SPECIFICATIONS
Thank You for purchasing this
Bloomfield Industries appliance.
Proper installation, professional
operation and consistent
maintenance of this appliance will
ensure that it gives you the very
best performance and a long,
economical service life.
This manual contains the
information needed to properly
install this appliance, and to use,
care for and maintain or repair the
appliance in a manner which will
ensure its optimum performance.
MODEL
9221EX
VOLTS
3NAC
380-415
WATTS
6250
L1
8.7
L2
8.7
AMPS
9.8
L3
N
1.1
HZ
50/60
1
FEATURES AND OPERATING CONTROLS
Fig 1. SS-2 Satellite Brewing System Features & Operating Controls
2
FEATURES AND OPERATING CONTROLS (continued)
Brewer
Adjustable Legs
Brewing Controls
Bypass Nozzle
Heater Switch
Hot Water Faucet
Nameplate
Ready-To-Brew Light
System Switch
(not shown)
Satellite Locator/Warmer
Warmer Switches
Brew Chamber
Brew Chamber
Bypass Diverter
Satellite
Brew-Thru Lid
Handles
Nameplate
Serving Faucet
Sight Glass
Drip Tray (optional)
Allows brewer to be leveled. Also allow clearance for cleaning
underneath brewer.
Start or stop brew and select brew volume. Right and left section
are independent.
Dilution water flows into brew chamber channel from here.
Dilution water DOES NOT flow through the coffee grounds.
Turns power to tank heater ON or OFF.
Hot water dispensed here.
Lists manufacturer, model and serial number.
Also lists voltage and wattage rating of brewer.
Glows when the tank water is up to temperature.
Located on lower right rear of brewer. Turns main power to
brewer ON or OFF .
Positions externally heated satellite on brewer. Maintains
temperature of product in satellite.
Control individual warmers for externally heated satellite .
Holds coffee grounds during brew cycle.
Forms dilution flow channel by holding filter clear of the brew
chamber wall.
Allows entry of brewed coffee and dilution water into satellite.
Minimizes splashing in the event satellite is tipped.
Allow the satellite to be safely carried.
Lists manufacturer, model and serial number.
Also lists voltage and wattage rating of satellite.
Fresh coffee dispensed from satellite here.
Check the level of coffee remaining here.
Optional drip tray catches drips and spills from serving faucet.
Easily removed for cleaning.
3
GENERAL INFORMATION AND PRECAUTIONS
WARNING:
Electric
Shock hazard
All servicing requiring access
to non-insulated electrical
components must be
performed by a factory
authorized technician.
DO NOT open any access
panel which requires the use
of tools. Failure to follow this
warning can result in severe
electrical shock.
CAUTION:
Burn Hazard
Surfaces of this brewer can
be hot and can cause burns
on contact.
IMPORTANT !
Do not store any combustible
materials or flammable liquids
anywhere near the appliance.
This appliance is intended for use in commercial establishments
only.
This appliance is intended
for human consumption. No other use is
by the manufacturer or its agents.
to brew hot beverage, specifically coffee,
recommended or authorized
Operators of this appliance must be familiar with the appliance use,
limitations and associated restrictions. Operating instructions must be
read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and
follow all included cleaning instructions and schedules to ensure the
safety of the food product.
Surfaces of the brewer, brew basket and satellite can be hot to the
touch, and may cause burns on contact.
Disconnect the brewer from electrical power before performing any
maintenance or servicing.
DO NOT submerge satellites in water.
DO NOT splash or pour water over, onto or into any controls,
control panel or wiring.
Any procedure which requires the use of tools must be performed by a
qualified technician.
This manual is considered to be a permanent part of the appliance.
This manual and all supplied instructions, diagrams, schematics, parts
breakdown illustrations, notices and labels must remain with the
appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this
appliance has American sizes on all hardware.
AGENCY APPROVAL INFORMATION
This dual satellite brewing system meets Standards
This dual satellite brewing system meets NSF Standard 4 only when
installed and maintained per the instructions in this manual.
STD 4
4
INSTALLATION INSTRUCTIONS
INSTALL LEGS & LEVEL THE UNIT
The brewer is provided with 4" (100 mm) adjustable legs and
rubber feet. Be sure the legs are securely screwed into the base
of the brewer, and that the rubber feet are properly installed.
The adjustable legs allow the brewer to be leveled. Set the brewer
in its ultimate operating location and check for level with a spirit
level Adjust the brewer for level from front-to-rear, and from sideto-side. Be sure all four feet rest firmly on the counter.
PLUMBER’S INSTALLATION INSTRUCTIONS
IMPORTANT:
Brewer must be installed on a potable water supply line with a
full-flow pressure between 20 psi (138 kPa) and 90 psi (620 kPa).
NOTE:
If water pressure varies greatly, or exceeds 90 psi (620 kPa) at
any time, a water pressure regulator must be installed. Plumbing
installer must supply the regulator.
Brewer must be connected to a potable water supply. Bloomfield
recommends not less than 1/4” (6 mm) inside diameter copper
tubing for installations of 12’ (4 meters) or less, and not less than
3/8” (10 mm) I.d. copper tubing for installations exceeding
12’ (4 meters).
Brewer must be connected to a COLD water line.
NOTE: DO NOT use a saddle tap for this water line connection.
A shut-off valve must be installed between the main water supply
and the brewer. Plumbing installer must supply the shut-off valve.
A 1/4-turn ball valve is recommended.
Flush the water line before connecting to the brewer.
Bloomfield highly recommends the use of the provided water
strainer to help prevent deposits in the brewing system.
CAUTION:
Hazard from
Unstable Equipment
Rubber feet must be installed
on each leg of the brewer.
Legs must be adjusted so that
all four feet rest firmly on the
counter. Failure to properly
install the feet can result in
movement of the brewer, which
can cause personal injury and/
or damage to the brewer.
SCREW INTO
BREWER
FRAME
ADJUST
FOR
HEIGHT
ATTACH
RUBBER
FEET
Fig. 2 Adjustable Leg
CAUTION:
Electric Shock
Hazard
Brewer must be properly
grounded to a reliable earth
ground to prevent possible
shock hazard. Do not assume
a plumbing line will provide
such a ground. Electrical shock
may cause serious injury.
5
INSTALLATION INSTRUCTIONS (continued)
IMPORTANT !
These installation instructions
are prepared for personnel
authorized, qualified, certified or
licensed to install electrical
equipment, who should perform
all initial startup and
adjustments.
IMPORTANT !
Do not store any combustible
materials or flammable liquids
anywhere near the appliance.
EUROPEAN ELECTRICAL INSTALLATION INSTRUCTIONS
IMPORTANT !
•Make sure the incoming voltage is the same voltage,
frequency and phase as specified on the appliance
nameplate. Connecting the appliance to the wrong voltage
may cause severe damage to internal components, or may
cause a severe decrease in performance.
IMPORTANT !
•An approved all pole power disconnect switch with at least a
3mm contact gap must be supplied and installed in the fixed
wiring in an accessible location (close proximity to the
appliance) by a licensed electrician. Refer to General Layout Data sheet for electrical ratings.
SUPPLY CORDS
•Power supply cords should be oil-resistant, sheathed flexible
cable not lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord (code
designation 245 IEC 57) or an approved metal conduit
connection.
•Minimum cross sectional area of conductors per line must be
1.5 square mm and total length not to exceed 2 meters
between supply connection and appliance. Supply wires
must be suitable for at least 90ºC temperature rating
•For flexible power cords, an approved strain relief fitting must
be supplied by others.
WIRING CONNECTIONS
•Using a screwdriver, remove rear panel.
•Knock out the appropriate hole plug and connect conduit
strain relief.
•Thread supply leads through strain relief and connect power
leads to terminals marked “L1”, “L2” & “L3”. Connect
neutral lead to terminal marked “N”.
•Connect ground lead (green with yellow stripe) to ground lug
marked “ ”.
•Secure all connections and reinstall terminal cover.
6
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.