Bloomfield 9221EX-SS2 Service Manual

671EX
OWNERS MANUAL
for
SS2 - SERIES
DUAL SATELLITE
COFFEE BREWERS
ELECTRO-MECHANICAL
CONTROL
and
EXTERNALLY HEATED
SATELLITE SERVERS
MODEL:
9221EX
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 9221EX Dual Satellite Brewer
p/n 76624 Rev. B ECN-12664 M671EX 040405 cps
WARRANTY STATEMENT
All electrical equipment manufactured by BLOOMFIELD INDUSTRIES is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by an Authorized Service Agency that the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements unless warranted conditions are the cause.
2. All problems due to operation at voltages other than specified on equipment nameplates; conversion to correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in accordance with electrical code requirements and wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is considered a preventative maintenance function and is not covered by warranty.
It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest Authorized Service Agency, transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific limitations are shown below (Additional Warranty Exclusions). Bloomfield Industries Authorized Service Agencies are located in principal cities.
This warranty is valid in the United States and void elsewhere. Please consult your classified telephone directory or your food service equipment dealer; or, for information and other details concerning warranty, write to:
Phone: (775) 689-5700 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied with each machine. Those miscellaneous adjustments noted are customer responsibility. Proper attention will prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours. Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted for ninety (90) days from date of purchase on non­ warranted equipment. Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered warranty.
12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians ability to perform services are not covered by warranty. This includes institutional and correctional facilities.
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Bloomfield Industries cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 4 AGENCY APPROVAL INFORMATION 4 INSTALLATION 5 OPERATION 7 CLEANING INSTRUCTIONS 10 PROGRAMMING INSTRUCTIONS 12 TROUBLESHOOTING SUGGESTIONS 17 SERVICING INSTRUCTIONS 18 EXPLODED VIEWS 20 WIRING DIAGRAM 24 SATELLITE 25
SPECIFICATIONS
Thank You for purchasing this Bloomfield Industries appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for and maintain or repair the appliance in a manner which will ensure its optimum performance.
MODEL
9221EX
VOLTS 3NAC
380-415
WATTS
6250
L1
8.7
L2
8.7
AMPS
9.8
L3
N
1.1
HZ
50/60
1
FEATURES AND OPERATING CONTROLS
Fig 1. SS-2 Satellite Brewing System Features & Operating Controls
2
FEATURES AND OPERATING CONTROLS (continued)
Brewer
Adjustable Legs
Brewing Controls
Bypass Nozzle
Heater Switch
Hot Water Faucet
Nameplate
Ready-To-Brew Light
System Switch (not shown)
Satellite Locator/Warmer
Warmer Switches
Brew Chamber
Brew Chamber
Bypass Diverter
Satellite
Brew-Thru Lid
Handles
Nameplate
Serving Faucet
Sight Glass
Drip Tray (optional)
Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer.
Start or stop brew and select brew volume. Right and left section are independent.
Dilution water flows into brew chamber channel from here. Dilution water DOES NOT flow through the coffee grounds.
Turns power to tank heater ON or OFF.
Hot water dispensed here.
Lists manufacturer, model and serial number. Also lists voltage and wattage rating of brewer.
Glows when the tank water is up to temperature.
Located on lower right rear of brewer. Turns main power to brewer ON or OFF .
Positions externally heated satellite on brewer. Maintains temperature of product in satellite.
Control individual warmers for externally heated satellite .
Holds coffee grounds during brew cycle.
Forms dilution flow channel by holding filter clear of the brew chamber wall.
Allows entry of brewed coffee and dilution water into satellite. Minimizes splashing in the event satellite is tipped.
Allow the satellite to be safely carried.
Lists manufacturer, model and serial number. Also lists voltage and wattage rating of satellite.
Fresh coffee dispensed from satellite here.
Check the level of coffee remaining here.
Optional drip tray catches drips and spills from serving faucet. Easily removed for cleaning.
3
GENERAL INFORMATION AND PRECAUTIONS
WARNING:
Electric Shock hazard
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.
CAUTION:
Burn Hazard
Surfaces of this brewer can be hot and can cause burns on contact.
IMPORTANT !
Do not store any combustible materials or flammable liquids anywhere near the appliance.
This appliance is intended for use in commercial establishments only.
This appliance is intended for human consumption. No other use is by the manufacturer or its agents.
to brew hot beverage, specifically coffee,
recommended or authorized
Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.
Surfaces of the brewer, brew basket and satellite can be hot to the touch, and may cause burns on contact.
Disconnect the brewer from electrical power before performing any maintenance or servicing.
DO NOT submerge satellites in water.
DO NOT splash or pour water over, onto or into any controls, control panel or wiring.
Any procedure which requires the use of tools must be performed by a qualified technician.
This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware.
AGENCY APPROVAL INFORMATION
This dual satellite brewing system meets Standards
This dual satellite brewing system meets NSF Standard 4 only when installed and maintained per the instructions in this manual.
STD 4
4
INSTALLATION INSTRUCTIONS
INSTALL LEGS & LEVEL THE UNIT
The brewer is provided with 4" (100 mm) adjustable legs and rubber feet. Be sure the legs are securely screwed into the base of the brewer, and that the rubber feet are properly installed.
The adjustable legs allow the brewer to be leveled. Set the brewer in its ultimate operating location and check for level with a spirit level Adjust the brewer for level from front-to-rear, and from side­to-side. Be sure all four feet rest firmly on the counter.
PLUMBER’S INSTALLATION INSTRUCTIONS
IMPORTANT:
Brewer must be installed on a potable water supply line with a full-flow pressure between 20 psi (138 kPa) and 90 psi (620 kPa).
NOTE:
If water pressure varies greatly, or exceeds 90 psi (620 kPa) at any time, a water pressure regulator must be installed. Plumbing installer must supply the regulator.
Brewer must be connected to a potable water supply. Bloomfield recommends not less than 1/4” (6 mm) inside diameter copper tubing for installations of 12’ (4 meters) or less, and not less than 3/8” (10 mm) I.d. copper tubing for installations exceeding 12’ (4 meters).
Brewer must be connected to a COLD water line.
NOTE: DO NOT use a saddle tap for this water line connection.
A shut-off valve must be installed between the main water supply and the brewer. Plumbing installer must supply the shut-off valve. A 1/4-turn ball valve is recommended.
Flush the water line before connecting to the brewer.
Bloomfield highly recommends the use of the provided water strainer to help prevent deposits in the brewing system.
CAUTION:
Hazard from Unstable Equipment
Rubber feet must be installed on each leg of the brewer. Legs must be adjusted so that all four feet rest firmly on the counter. Failure to properly install the feet can result in movement of the brewer, which can cause personal injury and/ or damage to the brewer.
SCREW INTO BREWER FRAME
ADJUST FOR HEIGHT
ATTACH RUBBER FEET
Fig. 2 Adjustable Leg
CAUTION:
Electric Shock Hazard
Brewer must be properly grounded to a reliable earth ground to prevent possible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
5
INSTALLATION INSTRUCTIONS (continued)
IMPORTANT !
These installation instructions are prepared for personnel authorized, qualified, certified or licensed to install electrical equipment, who should perform all initial startup and adjustments.
IMPORTANT !
Do not store any combustible materials or flammable liquids anywhere near the appliance.
EUROPEAN ELECTRICAL INSTALLATION INSTRUCTIONS
IMPORTANT !
Make sure the incoming voltage is the same voltage, frequency and phase as specified on the appliance nameplate. Connecting the appliance to the wrong voltage may cause severe damage to internal components, or may cause a severe decrease in performance.
IMPORTANT !
An approved all pole power disconnect switch with at least a 3mm contact gap must be supplied and installed in the fixed wiring in an accessible location (close proximity to the appliance) by a licensed electrician. Refer to General Layout Data sheet for electrical ratings.
SUPPLY CORDS
Power supply cords should be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (code designation 245 IEC 57) or an approved metal conduit connection.
Minimum cross sectional area of conductors per line must be
1.5 square mm and total length not to exceed 2 meters between supply connection and appliance. Supply wires must be suitable for at least 90ºC temperature rating
For flexible power cords, an approved strain relief fitting must be supplied by others.
WIRING CONNECTIONS
Using a screwdriver, remove rear panel.
Knock out the appropriate hole plug and connect conduit
strain relief.
Thread supply leads through strain relief and connect power leads to terminals marked “L1”, “L2” & “L3”. Connect neutral lead to terminal marked “N”.
Connect ground lead (green with yellow stripe) to ground lug marked “ ”.
Secure all connections and reinstall terminal cover.
6
Loading...