Bloomfield 9114EX Service Manual

WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
6 0 0
INSTALLATION INSTRUCTIONS
PART # 86280
Standard Brewers
Kit #86280 retrofits existing metal-shell thermostat with new hi-tech resin-bodied thermostat.
PREPARATION:
1. Disconnect brewer from electric power and allow to cool. Shut off water supply to brewer.
2. Remove top, front and/or back panels as required for access to thermostat.
3. Disconnect wiring from old thermostat. Loosen two screws holding thermostat to tank cover.
4. Remove thermobulb gland nut from tank cover. Withdraw thermobulb from fitting. Discard thermostat assembly.
INSTALLATION:
1. Insert bulb well into fitting on tank cover. Be sure well is fully seated in fitting.
2. Insert thermobulb into bulb well. Be sure bulb is inserted to the extreme bottom of the well.
3. Carefully insert capillary seal components into tank fitting.
IMPORTANT: Tighten gland nut only enough to prevent leaks. Over-tightening is not necessary.
4. Mount thermostat body to tank bracket. Reconnect wiring.
5. Reconnect brewer to electrical and water supplies. Test brewer for proper operation. Refer to page 2 for temperature adjustment procedure.
Upon completion, reinstall access panels.
CAUTION:
SHOCK HAZARD
Unplug brewer from electric power before beginning this procedure.
CAUTION:
BURN HAZARD
Allow brewer to cool before proceeding.
GLAND NUT
CAPILLARY SEAL
TANK FITTING
BULB WELL
THERMOBULB
INSERT BULB
FULLY INTO BULB WELL
Fig. 1 Thermobulb Installation
PRINTED IN UNITED STATES OF AMERICA
p/n 76697 Rev. A ECN-13394
1 of 2
I
600 080211 cps
CAUTION:
ELEVATION (feet above seal level)
0
500
1,000
1,500
2,000
2,500
3,000
3,500
4,000
4,500
5,000
5,500
6,000
6,500
TEMP. (ºF)
195
200
205
210
190
IDEAL BREWING TEMPERATURE RANGE
MAXIMUM SAFE TEMPERATURE SETTING
BOILING POINT OF WATER
SHOCK HAZARD
These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only.
NOTE:
Optimum brewing temperature range is 195ºF to 205ºF (90ºC to 96ºC).
IMPORTANT:
A mechanical thermostat will maintain temperature within ±5ºF. To prevent boiling water in the brewer, thermostat should be adjusted to a maximum temperature equal to the local boiling temperature minus 5ºF.
TEMPERATURE ADJUSTMENT
NOTE: This is a typical adjustment procedure for a standard
displacement brewer. Your exact procedure may vary depending on the method of adding cold water to the water heater.
1. Disconnect brewer from electric power. Remove top panel.
2. Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole.
THERMOSTAT
ADJUSTING
SHAFT
VENT
DIAL-TYPE THERMOMETER IN VENT HOLE
TANK LID
ASSEMBLY
Fig. 2 Checking and Adjusting Brew Temperature
3. Place an empty container under brew chamber. Reconnect brewer to electrical power. Energize brewer. Press TANK HEATER switch ON where applicable.
4. Press BREW switch OR pour one decanter (64 oz.) of cold water into pour-over opening. When READY TO BREW light glows (or HEAT light goes dark), read temperature displayed on thermometer.
5. Adjust thermostat by turning shaft; clockwise increases temperature counter-clockwise decreases temperature.
NOTE: 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on altitude.
600 76697 Instr Retro Cotherm Thermo
Table 1 Boiling Temperature by Altitude
6. Upon completion, remove thermometer and reinstall vent tube.
2 of 2
Loading...