Bloomfield 8541, 8573, 9011, 9013 Operation Manual

BLOOMFIELD INDUSTRIES SERVICE INSTRUCTIONS
Integrity™
9011 9013
Domestic and Export
B. INSTRUCTIONS
b. Remove TOP PANEL, FRONT PANEL and
SOLENOID ACCESS DOOR.
c.
Disconnect wires to solenoid. Re
move silicone
d. Remove BRASS NUT from INLET FITTING.
Lift solenoid
/
timer
/
bracket
assembly from mounting clip.
e.
Loosen screws on bottom of solenoid and
separate solenoid from bracket.
Remove solenoid and fi
ttings from cabinet.
Note::
SOLENOID
REMOVE SHADED COMPONENTS
2 Erik Circle Verdi, Nevada 89439 SOLENOID VALVE RETROFIT KIT
(775) 345-0444 84574 (120V) and 84575 (220/240V)
A. APPLICABILITY
CAUTION: ELECTRIC SHOCK HAZARD Unplug brewer before beginning conversion
1. REMOVE EXISTING SOLENOID (See fig. B.1 and B.2)
a. Unplug brewer and shut off water supply.
SUPPLY HOSE from solenoid.
Reinstall bracket on mounting clip.
Integrity™ shown Koffee-King™ similar
ACCESS DOOR
Fig. B.1
p/n 74536 Rev. (-) 040500cps Page 1 Of 3
ASSEMBLY
Fig. B.2
* SOLENOID ACCESS DOOR * SOLENOID AND FLOW CONTROL
* |N LET FITTING, TEE & ADAPTERS
B. INSTALLATIONS (continued)
ROUTE HOSES
Fig.
B.5
ATTACH PLASTIC
2. INSTALL NEW SOLENOID (See figure B.3, B.4 and B.5)
a. Assemble the SOLENOID BRACKET to the new ACCESS DOOR. Assemble the SOLENOID to
the SOLENOID BRACKET.
b. Route the silicone SUPPLY TUBE through the 3rd hole (from the front) then out the access door
opening. Attach tube to SOLENOID. Push the tube fully onto the outlet of the solenoid coil. c. Assemble the ACCESS DOOR / SOLENOID to the cabinet. Connect wiring to the solenoid. d. Turn wat er supply ON. Check for leaks. e. Insert BUTTON PLUG in the hole formerly occupied by the inlet fitting. f. Reinstall TOP PANEL and FRONT PANEL. Plug unit in and test.
AS SHOWN
Fig. B.3
HOSE TO OUTLET WITH SOLENOID:
* PUSH HOSE FULLY
AGAINST VALVE BODY
p/n 74536 Rev. (-) o405oocps page 2 of 3
Fig. B.4
Loading...