Bloomfield 8851, 8872, 8852, 8708, 8871 User Manual

WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707
www.wellsbloomfield.com
fax: 775-689-5976
763
For
Hot Plate-Style
Model 8702
Model 8852
Decanter W armer
MODELS
8708 Dual In-Line Warmer
8851 Single Warmer
8852 Dual Warmer
8871 Single Warmer
8872 Dual Warmer
Includes:
Installation Use & Care
Model 8871
NOTE: All warmers shown with optional 8900-Series Glass Decanters (available separately).
PRINTED IN CHINA
p/n 77719 Rev. (-) ECN-13409 M763 080124 cps
WARRANTY STATEMENT
Carafe Warmer models 8708, 8851, 8852, 8871 and 8872 manufactured by Wells Bloomfield, LLC are warranted against defects in material and workmanship for a period of ninety (90) days from original purchase original purchaser. THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING, BUT NOT LIMIT E D T O , WARRA N T I E S O F MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH WELLS BLOOMFIELD PRODUCTS.
,
and is for the benefit of the
This warranty is void if it is determined upon inspection by the factory that the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God. It also does not apply if the serial nameplate has been removed or service is performed by unauthorized personnel. This warranty is valid in the United States and Canada and void elsewhere. In addition to restrictions contained in this warranty, specific limitations are detailed in the ADDITIONAL WARRANTY EXCLUSIONS section.
Please contact: Bloomfield Service Department for all warranty claims: Phone: 775-689-5400 Fax: 775-698-5976
SERVICE POLICY AND PROCEDURE GUIDE
1. All problems due to operation at voltages other than specified on equipment name plates-conversion to correct voltage must be the customer's responsibility.
2. All problems due to electrical connections not made in accordance with electrical code
Additional Warranty Exclusions
requirements and wiring diagrams supplied with the equipment.
3. Replacement of items subject to normal wear. Normal maintenance functions are not covered under warranty.
4. Proper attention, full care and maintenance will prolong the life of the machine.
SHIPPING DAMAGE CLAIMS PROCEDURE
SHIPPING DAMAGE CLAIMS PROCEDURE
Note: For your protection, please note that the equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
If Shipment arrives damaged:
1. Visible loss or damage: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. File claim for damage immediately: Regardless of the extent of the damage.
3. Concealed loss or damage: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file "Concealed Damage" claim with them. This must be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Bloomfield Industries cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
763 p/n 77719 OpManual Decanter Warmers
TABLE OF CONTENTS
WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING COFFEE 8 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 Deliming Instructions 16 EXPLODED VIEWS & PARTS LISTS 18 SERVICE KITS 22 WIRING DIAGRAMS 23
Thank You for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for the appliance in a manner which will ensure its optimum performance.
SPECIFICATIONS
MODEL STYLE VOLTS 1ø WATTS AMPS POWER SUPPLY CORD
8708 8851
Dual Step-Up 200 1.7 NEMA-5-15P
Single 100 0.8
120 VAC 120 VAC
NEMA-5-15P
8852 8871 8872
Dual 200 1.7
Single 100 0.8
Dual 200 1.7
120 VAC 120 VAC 120 VAC
NEMA-5-15P NEMA-5-15P NEMA-5-15P
Decanter warmers operate at a warming temperature of approximately 185ºF ± 10ºF (85 ºC ± 6ºC).
763 p/n 77719 OpManual Decanter Warmers
1
FEATURES AND OPERATING CONTROLS
POWER CORD
WARMER PLATE
WARMER SWITCH " I " INDICATES "ON" "O" INDICATES "OFF"
Fig. 1 Features & Operating Controls Model 8852 shown. Features are similar for all models.
OPTIONAL DECANTER (SHOWN FOR POSITION ONLY)
SLIP-RESISTANT FEET
763 p/n 77719 OpManual Decanter Warmers
2
PRECAUTIONS AND GENERAL INFORMATION
WARNING: ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools.
Failure to heed this warning can result in electrical shock.
WARNING: INJURY HAZARD
All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical codes. Failure could result in property damage and pe rsonal injury.
WARNING: ELECTRIC SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or se rious injury.
This appliance is intended for indoor commercial use only. This appliance is intended for use to maintain the temperature of
hot liquids beverage products for human consumption. No other use is recommended or authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments, where all operators are familiar with the appliance use, limitations and associated hazards. Operating instructions and warnings must be read and understood by all operators and users.
The following trouble shooting, component views and parts lists are included for general reference, and are intended for use by qualified service personnel.
This manual should be considered a permanent part of this appliance. The manual must remain with the appliance if it is sold or moved to another location.
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the warmer may occur if these instructions are not followed.
CAUTION:
BURN HAZARD
Exposed surfaces of the warmer may be HOT to the touch. The warmer plate will be very hot during operation and can cause serious burns on contact.
Do not discard this appliance as usual trash at the end of its useful life. Recycle properly.
AGENCY LISTING INFORMATION
This warmer is listed under UL file E9253.
763 p/n 77719 OpManual Decanter Warmers
This brewer meets
CUS
Standard 4 only when installed,
operated and maintained in accordance with the enclosed instructions.
3
CUS
LISTED E9253
STD 4
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
CAUTION:
UNSTABLE
It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit.. Failure to do so will result in movement of the brewer which can cause personal Injury and/or damage to brewer.
EQUIPMENT HAZARD
WARNING:
SHOCK HAZARD
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.
IMPORTANT:
The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong nor twist a blade to fit an existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle.
Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly installed.
LEVELING THE UNIT
Verify that slip-resistant foot is installed at each corner of the warmer.
Set warmer in its operating location. Level the warmer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed.
Warmer models 8708, 8851, 8852, 8871 and 8872 are equipped with a cord and plug. They require a 115 - 125 volt 15 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R receptacle).
763 p/n 77719 OpManual Decanter Warmers
4
OPERATION
Place a decanter of hot beverage on a warmer plate. Press warmer switch for that warmer plate to ON ( I ). Press warmer switch to OFF (O) when a warmer plate is not in
use for any extended period. SUGGESTION: Coffee loses its fresh flavor if allowed to set on a
warmer for too long. Discard stale coffee promptly. DO NOT allow an empty decanter to set on a hot warmer. This
will damage the decanter. Discard any decanter that has been allowed to boil dry.
Disconnect warmer from electric power if unused for prolonged periods (i.e. overnight).
PROCEDURE: Clean Coffee Warmer
PRECAUTIONS: Disconnect warmer from electric power. Allow warmer to cool.
FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge
1. Disconnect warmer from electric power. Allow warmer to cool before cleaning. Remove decanters.
2. Wipe the warmer plates with a sponge dampened with warm water and a mild detergent. Rinse with clean water and allow to air dry.
3. Wipe the exterior of the warmer with a soft clean cloth or sponge moistened with clean water and allow to air dry.
Procedure is complete
CAUTION:
BURN HAZARD
Exposed surfaces of the warmer may be HOT to the touch. The warmer plate will be very hot during operation and can cause serious burns on contact.
CLEANING INSTRUCTIONS
CAUTION:
BURN HAZARD
Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns.
CAUTION:
SHOCK HAZARD
Do not submerge or immerse warmer in water. Do not pour or splash water onto switches or wiring.
IMPORTANT:
DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the warmer.
763 p/n 77719 OpManual Decanter Warmers
5
Genuine Parts
Protect - YOU - All - Ways
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
Commercial Food Equipment Service Association
Wells Bloomfield proudly supports CFESA
Commercial Food Equipment Service Association
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
PRINTED IN CHINA
Loading...