Bloomfield 2086EX, 2088EX, 2082, 2086, 2088, 2080 User Manual
Model 2082
Airpot Brewer
with optional
7759 Airpot
652
OWNERS MANUAL
for
E-Max™
AIRPOT and THERMAL
COFFEE BREWERS
MODELS
2080 2082
2086 2086EX
2088 2088EX
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 2080
Thermal Brewer
with optional
7754 Thermal Server
E-Max BREWERS are covered under
U. S. Patents #5704275, 5862738, 6095031.
Other U.S. Patents and Canadian Patents Pending
PRINTED IN UNITED STATES OF AMERICA
p/n 73574 Rev. S ECN-12817 M652 050208 cps
WARRANTY STATEMENT
All electrical equipment manufactured by BLOOMFIELD
INDUSTRIES is warranted against defects in materials and
workmanship for a period of one year from the date of original
installation or eighteen (18) months from the date of shipment
from our factory, whichever comes first, and is for the benefit
of the original purchaser, except that:
a. airpots carry a 30 day parts warranty only.
b.dispensers; i.e., tea and coffee carry a 90 days parts
warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY
EQUIPMENT MANUFACTURING CORPORATION SHALL
NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY
CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by
an Authorized Service Agency that the equipment has bee n
modified, misused, misapplied, improperly installed, or
damaged in transit or by fire, flood or act of God.
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers,
overload protectors, or fuse replacements unless
warranted conditions are the cause.
2. All problems due to operation at voltages other than
specified on equipment nameplates; conversion to
correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in
accordance with electrical code requirements and
wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include
such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is
considered a preventative maintenance function and is
not covered by warranty.
It also does not apply if the serial nameplate has been
removed or unauthorized service personnel perfor m service.
The prices charged by Bloomfield Industries for its products
are based upon the limitations in this warranty. Seller’s
obligation under this warranty is limited to the repair of defects
without charge by a Bloomfield Industries Authorized Service
Agency or one of its sub-agencies. This service will be
provided on customer’s premises for non-portable models.
Portable models (a device with a cord and plug) must be
taken or shipped to the closest Authorized Service Agency,
transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific
limitations are shown below (Additional W arranty Exclusions).
Bloomfield Industries Authorized Service Agencies are located
in principal cities.
This warranty is valid in the United States and void elsewhere.
Please consult your classified telephone directory or your food
service equipment dealer; or, for information and other details
concerning warranty, write to:
Phone: (775) 689-5700 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied
with each machine. Those miscellaneous adjustments
noted are customer responsibility. Proper attention will
prolong the life of the machine.
8. Trav el mileage is limited to sixty (60) miles from an
authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours.
Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted
for ninety (90) days from date of purchase on non warranted equipment. Any use of non-genuine Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered
warranty.
12. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technicians ability
to perform services are not covered by warranty.
This includes institutional and correctional facilities.
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
SHIPPING DAMAGE CLAIMS PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by
skilled personnel before leaving the factory.
Upon acceptance of this shipment, the transportation
company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill
or express receipt, and that the note of loss or damage
is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3.CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and file
“CONCEALED DAMAGE” claim with them. This
must be done within fifteen (15) days from the date the
delivery was made to you. Be sure to retain the
container for inspection.
Bloomfield Industries cannot assume liability for damage or
loss incurred in transit. We will, however, at your request,
supply you with the necessary documents to support your
claim.
xi
TABLE OF CONTENTS
WARRANTY STATEMENT xi
SPECIFICATIONS 1
FEATURES & OPERATING CONTROLS 2
PRECAUTIONS & GENERAL INFORMATION 3
INSTALLATION 4
AGENCY LISTING INFORMATION 5
OPERATION 6
CLEANING INSTRUCTIONS 11
SERVICING INSTRUCTIONS
PLUMBING 12
ELECTRICAL 14
DELIMING WATER TANK 16
TROUBLESHOOTING SUGGESTIONS 17
EXPLODED VIEWS AND PART LISTS 18
WIRING DIAGRAMS 22
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
Thank You for purchasing this
Bloomfield Industries appliance.
Proper installation, professional
operation and consistent
maintenance of this appliance will
ensure that it gives you the very
best performance and a long,
economical service life.
This manual contains the
information needed to properly
install this appliance, and to use,
care for and maintain or repair the
appliance in a manner which will
ensure its optimum perf ormance.
MODEL
2080 Thermal
2082 Airpot (incl 2082SNB)
2086 Thermal
2088 Airpot
2086EX
2088EX
k 1500 watts in Canada
VOLTS
50/60Hz 1ø
120 15
120/240 13.3 3200
220-240 13.3 3200
AMPS WATTS
1800k
POWER SUPPLY
REQUIREMENTS
15 Amp (NEMA 5-15R)
L1, N plus Ground
Hardwire to Circuit Breaker
L1, L2, N plus Ground
Hardwire to Circuit Breaker
L1, L2, N plus Ground
1
FEAT U R E S AN D OPER ATING CONTR O L S
2
PRECAUTIONS AND GENERAL INFORMATION
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated components must be performed by qualified
service personnel. Do not open any access panels which require the use of tools. Failure to
heed this warning can result in electrical shock.
WARNING:Injury Hazard
All installation procedures must be performed by qualified personnel with full knowledge of all
applicable electrical and plumbi n g code s. Failure could result in property damage and
personal injury.
WARNING Electric Shock Hazard
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a
plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING:Burn Hazard
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from
contact with dispensed liquids.
This appliance is intended for commercial use only.
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments,
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and
warnings must be read and understood by all operators and
users.
Except as noted, this piece of equipment is made in the USA
and has American sizes on hardware. Please note: Metric
hardware is used to mount the inlet (Fill) solenoid. All metric
conversions are approximate and can vary in size.
The following trouble shooting, component views and parts lists
are included for general reference, and are intended for use by
qualified service personnel.
This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is
sold or moved to another location.
CAUTION: Equipment
Electrical Damage
DO NOT plug in or
energize this appliance until all
Installation Instructions are read
and followed. Damage to the
Brewer will occur if these
instructions are not followed.
CAUTION: Burn Hazard
To avoid splashing or
overflowing hot liquids,
ALWAYS use an empty decanter
before starting the brew cycle.
Failure to comply can cause
serious burns.
CAUTION: Burn Hazard
After a brew cycle, brew
basket contents are HOT.
Remove the brew basket and
dispose of used grounds with
care. Failure to comply can cause
serious burns.
CAUTION: Burn Hazard
Exposed surfaces of the
appliance, brew basket
and decanter may be HOT to the
touch, and can cause serious
burns.
3
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
To enable the installer to make
a quality installation and to
minimize installation time, the
following suggestions and tests
should be done before the
actual unit installation is started:
CAUTION: Equipment
Electrical Damage
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.
CAUTION: Unstable
Equipment Hazard
It is very important for safety
and for proper operation that the
brewer is level and stable when
standing in its final operating
position. Provided adjustable,
non-skid legs must be installed
at each corner of the unit.
Failure to do so will result in
movement of the brewer which
can cause personal Injury and/
or damage to brewer.
NOTE: Water supply inlet line
must mee t cer tain mini m u m
criteria to insure successful
operation of the brewer.
Bloomfield recommends 1/4"
copper tubing for installation of
less than 12 feet and 3/8" for
more than 12 feet from a 1/2"
water supply line.
UNPACKING & INITIAL INSPECTION
1. Unpack the unit. Inspect all components for completeness
and condition. Ensure that all packing materials have been
removed from the unit.
2. (See page 13) Verify that the Spray Head and Spray Head
Gasket are properly installed.
LEVELING THE UNIT
1. Verify that an adjustable leg is installed at each corner of the
brewer.
2. Set Brewer in its operating location.
3. Level the Brewer. A spirit level should be placed on the top
of the unit, at the edge, as a guide when making level
adjustments.
4. Level the unit from left to right and front to back by turning the
adjustable feet. Be sure all four feet touch the counter to
1. Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to brewer.
2. DO NOT use a saddle valve with a self-piercing tap for the
water line connection. Such a tap can become restricted by
waterline debris. For systems that must use a saddle tap,
shut off the main water supply and drill a 3/16” (minimum) tap
for the saddle connection, in order to insure an ample water
supply. Remember to flush the line prior to installing the
saddle.
3. The brewer must be installed on a water line with average
pressure between 20 PSI and 90 PSI. If your water pressure
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply line to limit the pressure to not
more than 90 PSI in order to avoid damage to filters, lines
and solenoid.
4. A water shut-off valve should be installed on the incoming
water line in a convenient location (Use a low restriction type
valve, such as a 1/4-turn ball valve, to avoid loss of water
flow thru the valve.
4
INSTALLATION INSTRUCTIONS (continued)
For ‘Filter-Ready” units, refer to filter installation and hook-up
instructions packed with the brewer.
5. NSF requires that the brewer be able to be moved for
cleaning underneath. Loops of copper tubing will satisfy this
requirement.
6. In some areas, local codes require a backflow preventer
(check valve) to be installed on the inlet water line. If a back
flow preventer is used, you must install a water hammer arrester in the incoming line, between the backflow
preventer and the brewer inlet, as far away from the brewer
as space will allow. This will relieve the excessive back
pressures that can cause faucet leaks and solenoid
malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
NOTE: Models 2080 & 2082 require a 115 - 125 V 15A circuit
(50/60 Hz, 2 wire plus earth ground, with
NEMA 5-15R or 5-20R Receptacle)
Models 2086 & 2088 require a 120/240V 20A circuit
(50/60 Hz, 2 hot legs / 1 neutral leg, plus earth ground).
Circuit must be capable of 3500 Watts.
AGENCY LISTING INFORMATION
This brewer is and
This brewer meets
operated and maintained in accordance with the enclosed
instructions.
listed under UL file E9253.
Standard 4 only when installed,
NOTE: This equipment must
be installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING ELECTRIC
SHOCK HAZARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT: Do not attempt to
override the automatic tank fill
feature which requires that the
tank must be full of water to
start operations. Any attempt to
override this feature will void
the warranty.
IMPORTANT:
Before connecting to electricity,
make sure the E-Max™ has
been properly connected t o the
water supply.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
E9253
STD 4
E9253
5
OPERATION
OPERATING INSTRUCTIONS
IMPORTANT:
All E-Max™ brewers are
tested and set at the factory
If programming adjustments are necessary,
refer to the E-Max™
Programming Manual
(p/n/73674).
To over-ride the Brew
Wait mode, press and
hold the BREW key for
3 seconds when the
brewer is in Brew Wait
mode (i.e. when brew light
is flashing). The brew will
proceed immediately
regardless of water
temperature. This feature
should only be used when
testing water volume,
otherwise the brew will
proceed with the water
below the precise brew
temperature.
Note: the following
safety features have been
incorporated to prevent
multiple unattended
brews:
The brew key is disabled
during a brew cycle. This
minimizes the possibility
of double brewing.
When the “Brew” light is
on or flashing, repeated
pressing of the BREW
switch will be ignored,
(there will be a beep each
time it is pressed). A
Brew will only be activated
when the “Brew” light is
off.
.
1.Energizing the Brewer: When electricity has been connected to
the unit, there will be a momentary flash of the power light. Turn
the brewer on by pressing the POWER key. The
brewer will start to fill the tank. With the proper
water supply the tank should be filled in about 2½
minutes. Once filled, the heating element will come
on until the proper tank temperature has been
reached, (which will take about 20 minutes on
120-Volt models or about 12 minutes on 120/240
Volt models).
2. Brewing (Precise Temperature for Brewing™ — PTB™): In the
regular operating mode, the E-Max™ maintains the tank
temperature within +/- 1ºF of the brew temperature.
Normally this will mean that a brew will be started
as soon as the BREW key is pressed. However,
there may be a slight delay if the BREW key is
pressed immediately after a brew has been
completed (notably on 120 volt models). If the tank
temperature is below the brew temperature, the
brew will be delayed, going into the “Brew Wait”
mode, with the brew light flashing. As soon as the
correct temperature is reached the brew will
commence with the brew light on continuously during the brew . When
the brew begins the main warming station will be turned on
automatically (if it is not already on). During the brew cycle, if the
BREW key is pressed, it will be ignored. Only when the brew is
complete can another brew be started.
3. Brew Cancel: To cancel a brew in progress, press the CANCEL
KEY: two beeps will sound and the “Brew” light
will go out. Water flowing to the brew chamber
will be stopped immediately, but if there is
already water in the brew chamber, it will take a
few moments before this drips through as
coffee.
4. Normal Operation (Non Brewing): When the unit is not brewing,
the E-Max™ maintains the water temperature at the Precise
Temperature for Brewing™ (PTB™). The heating element will
cycle on and off automatically to maintain this temperature.
5. After Hours Mode: If no brew is detected for a pre-selected length
of time, the brewer will enter the After Hours mode. Temperature
will be allowed to drop to save energy. Pressing the BREW KEY
returns the brewer to normal operation.
6
USER’S GUIDE
OPERATION (continued)
1. Remove the brew chamber from
under the spray head. Place one (1)
genuine Bloomfield paper filter into
the brew chamber. Add your choice
of pre-measured ground coffee.
Shake the brew chamber gently to
level the coffee.
Slide the brew chamber back into
place.
2. Place an empty airpot or thermal server
under the brew chamber.
3. If any volume other than “Standard”
brew volume is required, press the
appropriate volume key.
4. To begin the brew cycle, press BREW
key. Hot water will start spraying over
the coffee, and brewed coffee will start
filling the server. When the coffee stops
flowing from the brew chamber, the fresh
coffee is ready to serve.
NOTE: Brewing will not begin until the
Precise Temperature for Brewing™ has
been reached. (See page 6)
5.
At the end of the brew cycle, the view screen
will read “Brew complete”.
After all dripping
has stopped, remove the brew chamber
from the brewer. Discard the used paper
filter and grounds.
Brew complete
6. The brewer is now be ready to begin
another brewing cycle.
PAPER
FILTER
BREW
CHAMBER
WARNING:
Burn Hazard.
This appliance dispenses
very hot liquid. Serious
bodily injury from scalding
can occur from contact
with dispensed liquids.
CAUTION:
Burn Hazard
To avoid splashing or
overflowing hot liquids,
ALWAYS use an empty
airpot or thermal server
before starting the brew
cycle. Failure to comply
can cause serious burns.
CAUTION:
Burn Hazard
After a brew cycle, brew
chamber contents are
HOT. Remove the brew
chamber and dispose of
used filter and grounds
with care. Failure to
comply can cause serious
burns.
CAUTION:
Burn Hazard
Exposed surfaces of the
appliance, as well as brew
chamber may be HOT to
the touch, and can cause
serious burns.
7
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.