Blodgett BLG-40G Owner’s Manual

BLG-G
GAS FLOOR MODEL BRAISING PAN WITH
MANUAL GEARBOX TILT
INSTALLATION – OPERATION – MAINTENANCE
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 864-0183
S00076 Rev A (8/04)
1
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
PURCHASER: Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location. This information shall be obtained by consulting the local gas supplier.
Keep the appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for servicing and proper operation.
Contact the factory, the factory representative or a local service company to perform maintenance and repairs should the appliance malfunction. Refer to warranty terms.
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should be retained for future reference.
2
TABLE OF CONTENTS
DESCRIPTION PAGE
Important Notes for Installation and Operation .......................................................... 2
1.0 Service Connections ......................................................................................... 4
2.0 Installation Instructions ...................................................................................... 5
3.0 Operation Instructions ....................................................................................... 8
4.0 Periodic Maintenance ...................................................................................... 11
5.0 Cooking Guidelines ......................................................................................... 13
6.0 Troubleshooting ............................................................................................... 17
3
SUPPLY PIPE PRESSURE (W.C.)
BLG-40G
BLG-30G
MODEL
kW/HR.BTU/HR.
11"-14" (279-356mm)7"-14" (178-356mm)
36.5
29.3
125,000
100,000
GAS SUPPLY
Natural Propane
DIMENSIONS
74.38 1889
38.88 987
39.38
1000
23.5 597
23.5 597
33.5 851
43.5
1105
1159
45.63
854
33.63
A
36.0 914
48.0
1219mm
inches
mm
inches
CAPACITYMODEL
30 gallons
114 litres
40 gallons
152 litres
BLG-30G
BLG-40G
73.75 1899
B
C
D E FUNITS
DIMENSIONS ARE IN INCHES [MM]
C
D
A
3
3
[
8
3
8
]
2
.
6
2
[
6
7
]
E
3.25 [83]
6.0 [152]
4.0 [102]
7
.
5
0
[
1
9
1
]
2
.
8
7
[
7
3
]
4
0
[
1
0
1
6
]
2
8
[
7
1
1
]
1
3
.
2
5
[
3
3
7
]
B
NOTE: OPTIONAL FAUCET NOT SHOWN IN FRONT VIEW.
OPTIONAL FAUCET
9
.
1
3
[
2
3
2
]
P
A
N
I
.
D
.
1.5 [38]
29.38 [746]
6.0 [152] MIN.
REAR FLANGED FOOT DETAIL
4 EQUALLY SPACED
Ø7/16” [11MM] HOLES
ON 3 [76] B.C.
Electrical connection to be as specified on data plat. Unit supplied with 6 foot cord with 3-prong plug.
GAS CONNECTION: Supply gas through 3/4” pipe. A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance.
COLD WATER: 3/8” O.D. tubing to faucet. (OPTIONAL)
HOT WATER: 3/8” O.D. tubing to faucet. (OPTIONAL)
1.0 SERVICE CONNECTIONS
4
2.0 INSTALLATION INSTRUCTIONS UNPACKING
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the type of gas supply (natural or propane) and electrical service agree with the specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do not agree, contact your dealer or Blodgett.
LOCATION The equipment must be kept free and clear of combustible substances. The tilting
braising pan, when installed, must have minimum clearance from combustible and non­combustible construction of 3" (76 mm) from sides and 6" (152 mm) from the rear. The tilting braising pan is intended for use on non-combustible floors.
The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 36" (914 mm) is required.
The tilting braising pan must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room suitable for the amount of combustion gas feeding the braising pan burners.
Do not permit fans to blow directly at the tilting braising pan, and wherever possible, avoid open windows next to the tilting braising pan. Avoid wall-type fans which create air cross currents within the room.
INSTALLATION CODES AND STANDARDS Installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi (3.5 kPa).
5
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. (120V units only).
WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made.
2.0 INSTALLATION INSTRUCTIONS (Continued)
INSTALLATION CODES AND STANDARDS (Continued)
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
ANSI/NFPA 96 - (latest edition), “Standard for Ventilation and Fire Protection of
Commercial Cooking Operations,” available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA, USA, 02269. FLUE CONNECTIONS Do not obstruct the flow of flue gases from the flue duct located on the rear of the tilting
braising pan. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.
LEVELLING AND ANCHORING
1. Set the appliance in place and level left to right and front-to-back using spirit level.
2. Mark hole locations on floor through anchoring holes provided in flanged adjustable
feet.
3. Remove appliance and drill holes in locations marked on floor and insert proper
anchoring devices (not supplied).
4. Set unit back in position and re-level left to right and front to back.
5. Bolt and anchor appliance securely to the floor.
6. Seal bolts and flanged feet with silastic or equivalent compound.