Project
Item No.
Quantity
Model 6G-6K-SB(36) (two 3 pan convection steamer compartments with
one 6 gallon kettle on a 36” wide, 200,000 BTU boiler)
CONSTRUCTION
Stainless steel construction
Stainless steel steamer doors with strong continuous hinge and are field
reversible for left or right swing. Insulated doors have a one piece,
replaceable seal. Hidden magnetic door switch cuts power to blower and
steam flow to that cavity, when the door is opened
Steamer pan support racks are polished stainless steel and removable
for easy cleaning
Wide drip sink with condensate drain is positioned under cavity doors
Kettle has reinforced rim and butterfly shaped pouring lip.
Kettle support legs are heavy tubular stainless steel.
Kettle shall be coded and registered for operation up to 55 PSI.
Gas heated, 36” wide cabinet base shall have stainless steel frame with
all stainless steel top deck, hinged front access panel and removable
side and rear panels
Cabinet-mounted boiler is ASME Code-constructed and National Board
registered for operation up to 15 PSI.
Front and rear legs shall have adjustable bullet feet
OPERATION
Steamer cavity controls are mounted on the front panel for easy access
with separate ON-OFF/60 minute timer control with constant steam setting, for each steamer cavity.
Kettle steam control valve and HOT/COLD water faucet handles are front
mounted with boiler controls.
Gas boiler has a gas control valve, power-ON switch, RESET light, start
switch, low water sensor, pop safety valve, water level sight glass and
outside cabinet mounted pressure gauge.
Unit will shut off if water level is low or unit builds too much pressure
When power switch is turned “off”, the boiler automatically drains to
reduce sediment build-up, after the water has cooled to 170°F.
Each steamer cavity shall have a powerful side mounted blower, which
increases steam velocity and provides efficient steam distribution
throughout cavity and between loaded pans.
Twin gas-heated, cabinet-mounted pressure boiler to provide atmospher-
ic steam to each chamber at a temperature of approximately 212º (F)
and steam to kettle at approximately 10 PSI.
The 200,000 BTU generator delivers 3.7 boiler horsepower.
Electronic ignition
STANDARD FEATURES
1/2” NPT power take-off valve for powering adjacent equipment
Flush mounted pouring sink with splash shield
Unit shall be provided with hot and cold water faucet with swing spout
One year parts and labor warranty*
* For all international markets, contact your local distributor.
BLODGETT
44 Lakeside Avenue, Burlington, VT 05401
Toll Free: (800) 331-5842 • Phone: (802) 860-3700 • Fax: (802) 864-0183
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
Flange mounting feet
Independent cold water to condensate spray
Cover and-or basket insert for kettle
6G-6K-SB(36)
Convection Steamer with Kettle
on a Gas Boiler Base
6G-5K-SB STEAMER WITH KETTLE ON A GAS BOILER BASE
Pan Size Per Cavity Total
12” x 20” x 1” 6 12
12” x 20” x 2.5” 3 6
12” x 20” x 4” 2 4
CAPACITY