Blodgett 3E-SN User Manual

(2)E-SN
Stacked Electric Convection Steamers
(2)E-SN STACKED CONVECTION STEAMER
Project
Item No.
Quantity
q Model (2)3E-SN (two 3 pan electric tabletop convection steamers on a
stand)
q Model (2)5E-SN (two 5 pan electric tabletop convection steamers on a
stand)
CONSTRUCTION
n Stainless steel construction n Stainless steel doors with strong continuous hinge and are field revers-
n Insulated doors have a one piece, replaceable seal n Easy open handle and latch provide positive lock and seal when the door
is pushed or slammed shut
n Hidden magnetic door switch cuts power to blower and steam flow to that
cavity, when the door is opened
n Pan support racks shall be polished stainless steel and removable for
easy cleaning
n Stainless steel condensate collection tray positioned under cavity door n Electric heating elements are replaceable from the side. n Split water lines
(2)5E-SN
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
q Water Treatment System q Stacking kit q Pan racks for support stand q Single water connection (cold water) q 4” adjustable legs
CAPACITY
Pan Size (2)3E-SN (2)5E-SN
12” x 20” x 1” 12 pans 20 pans
12” x 20” x 2.5” 6 pans 10 pans
12” x 20” x 4” 4 pans 6 pans
OPERATION
n Steamer cavity controls are mounted on the front panel for easy access n Steamer cavity controls include an ON-OFF power touch pad; 60-minute
electro-mechanical timer, with continuous steam setting; and READY light which indicates when cavity is ready for steaming.
n Auto-Delime button initiates deliming cycle. DELIME indicator light warns
operator of need to delime generator.
n Separate ON-OFF/60 minute timer control with constant steam setting,
for each steamer cavity.
n Unit will shut off if water level is low or unit builds too much pressure n When power switch is turned off, unit automatically blows down the
steam generator, to reduce sediment build-up.
n Powerful side mounted blower, which increases steam velocity and pro-
vides efficient steam distribution throughout cavity and between loaded pans.
n Electric-heated, rear-mounted steam generator to provide atmospheric
steam to the chamber at a temperature of approximately 212°F.
n Steam generator has an electric water sensor. n Steam generator delivers 2.6 KW (3 pan) or 3.1 KW (5 pan) power input
per 2-1/2” deep steam pan.
n 8-10 minutes heat-up time to READY under normal conditions. Cavities
are kept warm and ready for instant steam between loads. No cavity warm up required, after READY light comes on.
STANDARD FEATURES
n Stainless steel stand n One year parts and labor warranty*
* For all international markets, contact your local distributor.
BLODGETT
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
(2)E-SN STACKED CONVECTION STEAMER
2 (51)
8 (203)
1.25 (32)
3 (76)
30.81 (783)
15.5 (394)
door swing
NOTES:
1. Drain connection 1-1/2” tube (drain free venting)
2. Cold water supply at 30-60 PSIG withaflow rate of 1.00-2.00 GPM and witha3/4”NH connection.
3. Two electrical connection: 3/4” conduit fitting. See electrical requirement table.
4. Minimum side and rear clearance.
5. Dimensions are in inches (mm).
SHORT FORM SPECIFICATIONS
Provide Blodgett model (2)3E-SN (6 pan) or (2)5E-SN (10 pan) pressureless steamer with self-contained, atmospheric electric-heated steam
generator. All stainless steel construction, with powerful blower to circulate steam within cavity. Standard operating controls including: 60-minute
electromechanical timer, constant steam setting, ready light and delime cycle button to initiate deliming. Simple generator deliming through port on top. Door is field-reversible, with easy-open latch and hidden magnetic door switch. The atmospheric steam generator requires no pressure gauge or switches, has automatic drain and 16 KW for (2)3E-SN or 31 KW for (2)5E-SN power input. Unit shall come up to steam in 8-10 minutes from a cold start, and provide warm cavity instant steam capability and split water lines. Provide options and accessories as indicated.
21.69 (551)
1
TOP VIEW
2
1.25 (32)
3
Mounting holes in base use 3/8”-16 bolts which must not extend into steamer by more than 3/8 (10).
3 (76)
15.59 (397)
30.13 (765)
Rear of table or counter
2 (51)
FRONT VIEW
4
3
2 3
E
1
1
0.69 (17)
6 (152)
B
D
4
4
21.63 (549)
C
Optional 4” legs
Tabletop or counter
A
SIDE VIEWS
WATER SUPPLY:
Water quality is a major factor affecting the performance of your steamer. If you are unsure of water quality, consult a local water treatment specialist and have
the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids: Less than 30 PPM Total alkalinity: Less than 20 PPM Silica: Less than 13 PPM Chlorine: Less than 1.5 PPM pH Factor: 7.0 - 9.0
Water which fails to meet these standards should be treated by installation of a water conditioner. Failure or malfunction of this steamer due to poor water qual­ity is not covered under warranty.
WATER & DRAIN CONNECTIONS:
Drain 1-1/2” NPT free venting drain Cold Water Two 3/4” NPT cold water supply lines. Additional cold water connections are provided or spray condenser. Appliance is to be installed with backflow protection in accordance with Federal,
State or Local codes.
NOTE: The company reserves the right to make substitutions of components without prior notice.
POWER SUPPLY
(per steamer cavity)
VAC Phase
208V
240V
480V
SHIPPING INFORMATION:
Approx. Weight:
(2)3E-SN 390 lbs. (177 kg)
(2)5E-SN 488 lbs. (221 kg)
REAR OF STEAMER
Untreated water supply connection
Unit fuse box
Unit fuse box
1
1 39 8 74.5 15.5 3 23 8 44 15.5 1 33 8 64.6 15.5 3 20 8 38.2 15.5 1 17 8 n/a n/a 3 10 8 19.1 15.5
APPROVAL/STAMP
DETAIL VIEW
water connections
(if second connection
ordered)
Treated water supply connection
33.38 (772)
3
G
2
F
K
3
I
1
J
(2)3E-SN (2)5E-SN A B C D E F G H
K
33 (838) 46.5 (1181)
17 (432) 23.5 (597)
14 (356) 20.5 (520)
12 (305) 15 (381)
0.38 (10) 1.63 (41)
61 (1549) 64.38 (1635)
17 (432) 23.5 (597)
42 (1067) 39 (991)
40 (1016) 33.5 (851)
I
27.63 (701) 20.13 (511)
J
28 (711) 20 (508)
(2)3E-SN (2)5E-SN
Amps Max kW Amps Max kW
H
BLODGETT
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
P/N S00140 Rev B (8/12)