CONSTRUCTION
burner/combustion chamber. This combination delivers more uniform heat transfer over the entire cooking surface.
Control and tilt mechanism are mounted in stainless steel housings on
the pan body sides
100 grit interior finish is coarse enough to retain butter, shortening or oil
during the cooking process, minimizing food sticking and burning
A heavy-gauge, fully adjustable one-piece cover is standard with tor-
sion bar type counterbalance designed to maintain selected cover posi­tion.
True rounded leg tubular stand design and 3” radius pan interiors make
cleaning easier.
OPERATION
Electronic intermittent pilot ignition systemSmooth-action, quick-tilting body with manual crank tilt mechanism,
which provides precise control during pouring of pan contents for easy operation
Pan tilts past vertical for easy cleaningControls allow operation at a 7 degree angle to facilitate griddling.Thermostatically controlled for automatic shut-off when desired temper-
ature is reached or heating when temperature falls below desired set­ting
High limit thermostat for safetyConsole mounted power switch with indicator lightControl includes a heat indicator light and temperature control switchA vent in the cover top regulates condensate buildup and a rear con-
densate drip shield is located under the cover to prevent condensate from dripping on floor when cover is opened.
STANDARD FEATURES
Mounting bracket for either right, left or rear faucet mountingEtched markings (specify)
GallonsLitres
One year parts and labor warranty*
* For all international markets, contact your local distributor.
BLODGETT
44 Lakeside Avenue, Burlington, VT 05401
Toll Free: (800) 331-5842 • Phone: (802) 860-3700 • Fax: (802) 864-0183
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
Faucets
Single pantry faucetDouble pantry faucet
Spray hose assembly for panty faucets
48” (1219 mm)
60” (1524 mm)Standing pilotSteam pan insertSteam pan carrier2” tangent drawoff (must be ordered with unit)Strainer for tangent drawoff valvePouring lip strainerFlanged feetCasters
G-BLT
Gas Floor Model Braising Pan with Manual
Tilt
G-BLT BRAISING PAN WITH MANUAL TILT
BLODGETT
44 Lakeside Avenue, Burlington, VT 05401 Toll Free: (800) 331-5842 • Phone: (802) 860-3700 • Fax: (802) 864-0183
G-BLT GAS BRAISING PAN
WITH MANUAL TILT
SHORT FORM SPECIFICATIONS
Provide Blodgett model 30G-BLT, 30 gallon (114 litre) or 40G-BLT (152 litre) gas braising pan. Unit shall be stainless steel gas-heated and thermostatically controlled on a rounded tubu­lar leg stand. Heavy 5/8” thick stainless steel clad pan bottom shall have a gas burner/combustion chamber and specially-designed welded heat transfer fins. Electronic ignition is stan­dard; 30 gallon pan is 39” wide and 40 gallon pan is 48” wide both with a 10” deep pan. Smooth- action quick tilting pan body with manual crank tilt mechanism, heavy-duty fully adjustable counter balanced cover with condensate drip shield and cover vent. NSF listed and CSA design-certified. 1/2” NPT gas connection required and standard electric spark ignition requires 115 Volt, single-phase, 60 Hertz, 5 AMP supply. Specify Natural Gas or LP Gas. Made in U S A. One year parts and labor warranty. Provide options and accessories as indicated.
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
NOTE: The company reserves the right to make substitutions of components without prior notice.
Pour Path
Full Tilt
Position
Cover Open
Access Panel
RIGHT SIDE VIEW
3
Pour Path Max.
46.0 [660]
Pour Path Min.
25.0 [635]
34.38 [873]
.75 [19] Min.
2.0 [51] Max.
1.8 [46]
70.3
[1786]
31.90 [810]
9.9
[250]
28.25 Pan I.D.
[718]
25.7 [653] Electric
Connection
25.0 [635] Gas
Connection
ADJUSTABLE
Finished Floor
FEET
FRONT VIEW
C
L
C
L
10.00 [254]
Inside Pan Depth
26.28 [668]
43.3
[1100]
37
[940]
B
5.42
[138]
NOTES:
1. Dimensions are in Inches [mm]
2. Casters or flanged feet available at an extra cost.
3. Electrical Connection: 0.875" dia. [22] hole
4. Electrical power not required on optional standing pilot models.
5. Faucet bracket may be installed on left or right side.
6. Faucet may be installed on faucet bracket or on rear as shown.
TOP VIEW BRAISING PAN
Pouring
Lip
Location of Optional 2" Tangent Drawoff
11
[279]
8 [203]
D
C
L
5
Faucet
Cover
Vent
TOP VIEW
3
21.5
[546]
39.75
[1010]
5.25 [133]
Electric Connections
2.00 [51] Gas Connections
3.00[76] Min Rear Wall Clearance
3.4 [86]
3.4 [86]
C
A
Pan I.D.
Faucet Optional Location (2 Places)
Faucet
(Optional Location)
APPROVAL/STAMP
P/N S00111 Rev B (4/11)
MODEL A B C D
30G-BLT 26.25 (667) 32 (813) 38.5 (984) 8.75 (222)
40G-BLT 35.75 (908) 41.5 (1054) 48 (1226) 13.5 (343)
MAXIMUM INPUT:
30G-BLT 104,000 BTU 40G-BLT 144,000 BTU
GAS SUPPLY:
1/2" NPT connection required. A gas shut-off valve must be installed in supply piping convenient and adjacent to unit.
Inlet Pressure:
Natural 4.5" W.C. min, 14” W.C. max Propane 11" W.C. min, 14” W.C. max
ELECTRICAL CONNECTION:
Requires one 115 Volt, single-phase, 60 HZ, 5 AMP supply.
SHIPPING INFORMATION:
Approx. Weight:
30G-BLP 495 lbs. (225 kg) 40G-BLP 591 lbs. (268 kg)