BLOCK TRANSFORMATOREN PVSL 24 10 Instructions

Page 1
PVSL 400
Stabilisierte Stromversorgung mit integrierter Kontrolleinheit und Netzeingangsüberwachung
Stabilised power supply with integrated control module and line monitor
KAPVSL400 2015•02
Anschluss
Um Verwechslungen mit anderen An­schlüssen zu vermeiden, verwenden Sie
T
ausschließlich die mitgelieferten Stecker.
Ab b ild u ng ze i gt den PV S L 400/ 24 - 2 0
Thi s figu r e show s th e PVSL 40 0 /24 - 20
Eingang
line
PE L1 L 2 L3
4
c
1
b a
2 3
8
+ + – – Ausgang
load
U
out
8
optionales
Zubehör
optional
accessory
S1: geschlossen, wenn Betriebsstundensignalgeber erreicht cl ose d, if mi n. on e ch anne l tri pp ed S2 : of fen , wen n Fe hle r au f tr itt ope n, if a f au lt has oc cu rr ed S3 : ge sch lo ss en, w en n Wa rn ung au ft ri tt clo sed , if a war nin g oc cur rs S4: geschlo ssen, wenn Uou t < Po wer Good clo sed , if Uo ut < Pow er Go od
S1 S2 S3 S4
RxPC TxPC
12345678
block.eu
Connection
To re duce th e ri sk of mis tak ing the terminals, the supplied terminals must
T
be used.
6
7
T
U
out
Pi n 2 = RxP C Pi n 3 = TxPC Pi n 5 = GND
DIN 35 mm rail
Installation
Installation
Sicherheitsmaßnahmen vor der Installation
Das Betriebsmittel ist vor unzulässiger Beanspruchung zu schützen. Insbesonde­re dürfen bei Transport und Handhabung keine Bauelemente verbogen und/oder Isolationsabstände verändert werden. Die Berührung elektrischer Bauele­mente und Kontakte ist zu vermeiden. Da s Betrie b smi t t e l imm e r im sp a n­nungsfreien Zustand montieren und verdrahten. Die Produktbeschreibung und die technischen Hinweise in unserem Hauptkatalog sowie die Aufschrif ten am Betriebsmittel und auf dem Typenschild sind zu beachten.
Die Installation ist entsprechend den örtlichen Gegebenheiten, einschlägigen Vorschriften (z. B. VDE 0100), nationalen Un f allv e rhüt u ngsv orsch r if t en (z. B. UV V­VBG4 bzw. BGV A3) und den anerkannten Regeln der Technik durchzuführen. Dieses el e k t ris c he Betr i ebsm i t tel is t eine Ko m ­ponente, die zum Einbau in elektrische Anlagen oder Maschinen bestimmt ist und erfüllt die Anforderungen der Niederspannungsrichtlinie (2014/35/ EU). Um eine ausreichende Konvektion zu gewährleisten, sind folgende Mindest­abstände zu benachbar ten Modulen empfohlen: 40mm oben und unten, 10mm auf der linken und rechten Seite. Bei Einbau in Maschinen ist die Aufnahme des bestimmungsgemäßen Betriebes solange untersagt, bis festgestellt wurde, dass die Maschine den Bestimmungen der Maschinenrichtlinie (2006/42/EG) en t s pri c h t . EN 60 204 is t zu beac h t en. Die Aufnahme des bestimmungsgemäßen Betriebes ist nur bei Einhaltung der EMV­Richtlinie (2014/30/EU) erlaubt. Die Einhaltung der durch die EMV-Gesetz­gebung geforderten Grenzwerte liegt in der Verantwortung des Herstellers der Anlage oder Maschine.
LED: Die grüne LED (a) leuchtet,
1
sofern die Ausgangsspannung größer als ca. 20,4 Vdc (veränderbarer, werk­seitiger Power Good Schwellenwert) ist. Die gelbe LED (b) zeigt Warnungen an . Die rot e LE D (c) zei g t Fehl e r an.
Display der Kontrolleinheit: Das Einstellen und Parametrisieren des Gerätes über das Display wird auf der Rückseite erklärt.
Tas ten:Linke Taste = vorwärts im
3
Me nü, rec h t e Taste = zu m Para me­trisieren.
Eingang (schwarzer Stecker) line
4
Ausgang (bla u er Stec ker) load
5
Montage: Setzen Sie das PVSL mit
6
de r Trags c hien enfüh r ung an die Ob e r ­ka n t e der Tra gsc h iene an und ra s t en Si e es nac h unten ei n . Demontage: Ziehen Sie den
7
Schnappriegel mit Hilfe eines Schraubendrehers auf und hängen Sie das Modul an der Unterkante der Tragschiene aus.
Schnittstelle und Signalausgänge:
8
Die Schutzkappe ist zur Vermeidung statischer Entladungen nur unter An­wendung von ESD-Schutzmaßnahmen abzunehmen. Frei belegbare Ausgän- ge, konfigurierbar per PC mit CONFI POWERVISION, Betriebsstunden­signalgeber (werkseitige Belegung), Fe h ler, Warn ung, Power Good (werkseitige Belegung), Kommunikationsein- und Ausgänge, Ausgangsspannung. Die Schnit tstelle ist nicht galvanisch getrennt. Ein geeignetes Adapterka­bel (PV-KOK2) oder den passenden Stecker (PV-CON) können Sie optional über BLOCK beziehen. Bei Anschluss eines Relais an einen Signalausgang muss zwingend eine Freilaufdiode vorhanden sein.
Safety measures before installation
This equipment is to be protected against improper use. Components are not to be be nt or is olat i on spa c ing ch ang e d, es­pecially through handling and transport. The contact with electrical components and terminals is to be avoided. Always disconnect the equipment from the mains supply, before commencing installation or wiring. The product description, technical information in our main catalogue and the marking on the equipment ratings plate ar e to be obse r ved.
In s t all a tion must be ca rrie d out acc o r ­ding to the prevailing local conditions and safety regulations (e.g. VDE 0100) national accident prevention regulations (e . g . UV V-V B G4 or BG V A3) and th e ge­nerally accepted rules of technology. This equipment is a component designed for installation into electrical systems and machines, and fulfils the requirements of the low voltage guidelines (2014/35/EU). In order to ensure sufficient convection, fol low in s tall ation c lear ance s is recom ­mend: 40mm on top and bottom, 10mm on the left and right side. When installed into machinery, the normal operation is forbidden until it is determined that the machine fulfils the requirements of the machinery guidelines (2006/42/EG). EN 60204 must be observed. The EMC req uire m ents (2 014 /30 / EU) mu s t be ful ­filled before operation is commenced. The observance of the required limitations for the EMC legislation is the responsibility of the manufacturer of the installation or machinery.
LED: The green LED (a) lights as soon
1
as the output voltage is larger than approx. 20.4 Vdc (changeable, factory set Power Good level). The yellow LED (b) shows a warning condition. The red LE D (c ) sho w s a faul t co ndi t ion.
Th e cont r ol un it dis play: The
22
parameter adjustments are de s crib e d on the ba ck of th i s leaf l e t .
Buttons: Left button = forward in
3
the menu, right button = to alter parameter settings.
Input (black plug) line Output (blue plug) loa d
5
Mounting: Place the PVSL with the
6
DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing: Pull the snap lever open
7
with the aid of a screwdriver and slide the module out at the lower edge of the DIN rai l .
In t erfa ce and outpu t sign al po r t:
8
The protective cap is to reduce the risk of static discharge and should on l y be rem o ved wi t h th e use of E SD protective measures. 14 Free output connections that can be configured pe r PC with CON FI POWE R V ISI O N,
1 operational time elapse (factory
set), 2 fault, 3 warning,
4 Power Go od (fa c t ory set ) , 568
communication input and output, 7 output voltage. The interface has no galvanic separation and should be only connected with a suitable adapter cable (PV-KOK2) or the plug (PV-CON) that are available from BLOCK . If a relay is to be connected to a signal output then it is imperative tha t a free ru n nin g diod e be used .
Page 2
Einstellen und Parametrisieren über das Display
A = mit di es em Be f eh l ( li nk e Tast e ) ko mm en Si e zu m näc hst e n Me nüp un k t
1
Standardanzeige
Zeigt die aktuelle Ausgangsspannung und den aktuellen Ausgangsstrom an. Nach einer Parameteränderung wird automa­tis ch die s e Dar s t ellu ng gew ählt .
2
Ausgangsspannung einstellen
Da s Disp lay ze i gt di e ak tuel l e Aus gang s­spannung an. Das Ändern der Spannung ist durch Betätigen der linken Taste möglich. Die Spannung kann entweder bis zum unteren Spannungslimit verringert werden oder bis zum oberen Span­nungslimit erhöht werden. Nachdem das jeweilige Spannungslimit erreicht wurde, dreht sich die Richtung der Spannungs­änderung um.
A = Ausgangsspannung schrittweise verändern B = Ausgangsspannung speichern
Der gespeicherte Spannungswert stellt sich nach jedem Einschalten des Gerätes automatisch wieder ein.
3
Betriebsstundenzähler
Der Betriebsstundenzähler zeigt an, wie lange das Gerät in Betrieb ist. Die oberen 3 Ziffern sind mit 1000 zu multiplizieren und zu den unteren 3 Ziffern zu addieren. In unserem Beispiel 1979 Stunden.
4
Betriebsstundensignalgeber
Der Betriebsstundensignalgeber zeigt an, zu welchem Zeitpunkt der zugehörige Signalausgang für 1 Sekunde von 0 Volt auf die Ausgangsspannung umschaltet.
Eingestellter Standardwert: 5000 h
B = Betriebsstundensignalgeber ein­stellen
Betriebsstundensignalgeber einstellen
A = Einstellen der Tausender-Stunden (kh) B = Bestätigen der Tausender-Stunden (kh)
A = Einstellen der Stunden B = Bestä t i gen de r St und e n
B = Bestä t i gen Ei nstel lung
5
Betriebsstunden-Countdown
Anzeige der verbleibenden Stunden bis das Betriebsstunden-Signal am Ausgang generiert wird.
6
Überstromverhalten
Es wi r d ang e zeig t , welch e s Über s t rom­verhalten eingestellt ist. Es können drei Modi parametrisiert werden.
B = Überstromverhalten einstellen
Überstromverhalten einstellen
A = zw isc h en Kon s t ant s t r om-Mo dus un d Fuse-Mode wechseln B = Konstantstrom-Modus speichern und zur Konstantstromzeit wechseln I.Co = Konstantstrom-Modus I.Fu = Fuse-Mode
A = Zei t für den Ko nstan t s trom Mo dus in
Se k und e n (ca. 110 % I Wechsel in den Fuse-Mode
NENN
) bis zum
B = Konstantstromzeit speichern I. t = Kons t a ntstr o m zeit 00 0 s = unbe g renz t
Modus 1: begrenzte Konstantstromzeit mit anschließendem Fuse-Mode (siehe
6.1) Modus 2: unbegrenzte Konstantstrom-
zeit (siehe 6.2) Modus 3: Fuse-Mode (siehe 6.3)
7
Minimale Ausgangsspannung
8
Maximale Ausgangsspannung
9
Maximaler Ausgangsstrom
Zum Rücksetzen der Werte für be i de Tas t e n für 5 Se k und e n betäti g en.
10
Aktuelle Eingangsspannung
Anzeige der aktuellen Eingangsspannung in Vac, ge mittel t über al le dre i Phase n .
11
Minimale Eingangsspannung
In diesem Menü kann der Schwellwert für die minimale Eingangsspannung programmiert werden. Sinkt die Eingangsspannung unterhalb dieses Schwellwertes, generiert der PVSL 400 ein Warnung (gelbe LED leuchtet , Warnungs-Signalausgang ist aktiv und im Fehler Manager wird diese Warnung angezeigt)
B = minimalen Schwellwert einstellen
Minimale Eingangsspannung einstellen
A = minimalen Schwellwert einstellen B = minimalen Schwellwert speichern
12
Maximale Eingangsspannung
Schwellwert für die maximale Eingangs­spannung (siehe Punkt 11)
B = maximalen Schwellwert einstellen
Maximale Eingangsspannung einstellen
A = maximalen Schwellwert einstellen B = maximalen Schwellwert speichern
13 14
Aktuelle Netzfrequenz/Drehfeld-
richtung
Die aktuelle Netzfrequenz sowie die Drehfeldrichtung werden angezeigt. Im Falle eines Phasenausfalls kann die Dreh­feldrichtung nicht bestimmt werden und es wird die letzte ermittelte Drehfeldrich­tun g vor de m Phas e nau s fall einge f r oren.
r = Dr e h f eld r icht u ng rec h t s L = Dr e h f eld li nks
15
Fehlermanager
Anhand des Fehlercodes (siehe auch Typenschild am Gehäuse) kann anhand der blinkenden Segmente, eine Fehlerana­lyse vorgenommen werden.
Der letzte Fehler wird fest gespeichert, so dass auch noch nach einem Neustart des PVSL 400 eine Fehlerursache detek­tiert werden kann.
B = letzten Fehler anzeigen
7 8 9
Setting the parameters using the display
A = pres si ng th e le ft bu tto n mea ns mo ve to nex t men u po int
1
Standard display
Shows the actual output voltage and current. This display is always shown after changing any parameter settings.
2
Output voltage setting
The display shows the actual output voltage. The voltage can be changed by pressing the left button. The voltage can be changed to either the upper or lower level settings, after reaching one limit setting the direction will automatically reverse.
A = chan ges ou t put vo l t age st e p by step B = save th e outp u t volt a g e setti n g
Switching on the power supply, the saved se t t i ng wil l auto m atic a lly be re s et.
3
Operational hours display
This display shows how many operational hours have elapsed. The three upper nu mera ls ar e the 10 00 hr s and to be added to the 3 lower numerals. In our ex a mpl e 1979 hour s .
4
Operational time counter
This display shows at which time the related signal output switched from 0 V to th e se t out p u t volt a ge.
Fa c tor y st and ard se t ting: 500 0 h
B = set the op era t i ona l time co u nter
Setting the operational time counter
A = adj u stin g the tho u san d hour se t t ing (kh) B = confi r m the tho usan d hour se t ting (kh)
A = adj u stin g the hou r settin g B = confi r m the ho u r setti n g
B = confi r m all th e settin g s
5
Operational hours countdown
Displays the remaining time for the operational hours signal to be generated at th e outpu t .
6
Overload current behaviour
This displays what overload condition is presently set. There are three parameter settings possible.
B = over l oad cu rrent se t t ing
Setting the overload current
A = switch be t ween co nstan t curre n t an d fuse mo de B = save co nstan t curr e n t mod e and ch a nge to co nsta n t curr e n t time I.Co = constant current mode I.Fu = fuse mode
A = Tim e settin g to chan g e from th e
const ant current mode in seconds (e . g . app r ox. 110% I fuse mode.
B = save co nstan t curr e n t setti n g I. t = const a nt cur r e nt tim e settin g 00 0 s = unli mited
rated
) to the
Mode 1: limited constant current until sw i t c hin g to fuse mo de (se e 6.1)
Mode 2: unlimited constant current (see
6.2) Mo d e 3: fu s e mod e (see 6. 3 )
7
Min. output voltage
8
Max. output voltage
9
Max. output current
To res e t the va lues fo r bu t t o ns for 5 se cond s.
10
Actual input voltage
7 8 9
pres s bo th
Displays the actual input voltage as average over the three phases.
11
Lower input voltage level
In this menu the lowest input voltage level can be set. If the input voltage drops below this level the PVSL 400 will generate a warning (yellow LED lights). The signal output is active and shown in the fault manager.
B = set lo w er vol t a ge le v e l
Setting the lower input voltage
A = set lo w er vol t a ge le v e l B = save lo wer vo l t age se t t ing
12
Higher input voltage setting
upper level setting for the input voltage (s e e no. 11 )
B = set hi g hes t vo ltag e level
Setting highest voltage
A = set hi g hes t vo ltag e level B = save ma x . vol t a ge set t i ng
13 14
Actual line frequency and rotary
field direction
Displays the actual line frequency and rotary field direction. This display cannot be sh own If one ph ase fa ils . Th e las t co n diti o n befor e th is fai lur e wi ll be fr o z en.
r = rot a r y fiel d direc t i on is cw (c lock w i se) L = rot ary field direction ccw (count er clockwise)
15
Fault manager
A fault analysis can be made according to the blinking segments of the display (see rating plate on housing).
The last fault symptom will be automatically saved, so that even after a ne w st art a fau l t ana l yse ca n be mad e .
B = show last fa u lt di s pla y
6.1 6.2 6.3
X x Inenn
X x Irated
Inenn
Irated
Unenn
Urated
Top Boost
NENN + 60 A
I
Power Boost
Konstantstromzeit
(005=5 Sek)
constant current
time (005 s=5 sec)
Überstrom
Overload current
SET
Iout
I.Co
Fuse Mode
005
Iout
I.t
s
X x Inenn
X x Irated
Inenn
Irated
Unenn
Urated
Top
Boost
Top Boost
NENN + 60 A
I
Power Boost
Konstantstromzeit
(000 s=unbegrenzt)
constant current time
(000 s=unlimited)
Überstrom
Overload current
SET
Iout
I.Co
000
Iout
I.t
s
X x Inenn
X x Irated
Inenn
Irated
Unenn
Urated
Top
Boost
Top Boost INENN + 60 A
Fuse Mode
Überstrom
Overload current
SET
Iout
I.Fu
Page 3
Uout
23.9
Vdc
Iout
1
9,76
Adc
Uout
Uout
25,5 SET
003 SET
SET
Iout
I.Co
SET I.Fu
SET 377
SET 420
Err !$!
STO
Vdc
Uo
logtime
logtime kh
SET
003
h
297
297
s
005
STO
Iout
I.t
I.Co
STO I.Fu
Ui.L STO
Ui.H STO
23.9
Vdc
Iout
2
9,76
Adc
log kh
001
h
3
979
logtime kh
4
h
297
time
kh
003
5
h
297
FU
Iout
6
I.Co
Uo.L
7
22,5
Uo.H
8
26,7
Io.H
9
27.5
Ui
10
402
Ui.L
11
375
Ui.H
12
430
F r
13
Hz
50
F L
14
Hz
50
Err
15
!!!
Segment blink t
Segment blinks
Uo Ausgangsspannung
output voltage
STO
store
SET Einstellungen vornehmen
setting
FU Überstrommodus
overload current behaviour
I.Co Konstantstrommodus
const ant current mo de
I.Fu
fuse mode
I.t Konstan tstr omzeit
const ant current time
Uo.H max. Ausgangsspannun g
max. ou tput voltage
Uo.L min. Ausgangsspannung
min. output voltage
Ui Eingangsspannung
input voltage
Ui.L min. Eingangsspannung
min. input voltage
Ui.H max. Eingangsspannung
max. input voltage
F Frequenz
frequency
r Drehf eldrichtung rechts
rotary field direction is cw
L Drehfeldrichtung links
rotary field direction is ccw
I.Hi max. Ausgangss trom
max. ou tput current
Err Fehlermanager
fault manager
Einstellungen gespeichert
Fuse mode
PVSL 400/24-10 PV SL 40 0/ 24 -20 PVSL 400/24-40
Schaltnetzteil, dreiphasig e, primär getakte te Einbaustrom verso rgung für
Primary switched mode supply, three phase primar y switched mode power supply
No rm en Safety standards
Sicherheit Safety EN 6095 0, UL 609 50 , UL 50 8
EM V EMC EN 612 0 4- 3 (Pr odu kt nor m) EN 61 204 - 3 (p rod uc t sta nda rd)
Technische Daten
Schutzkleinspannung
Technical details
Sa fet y ext r a- low vol tag e
Zulassungen Approvals
UL UL UL /CS A 60 950 r ec ogn is ed
logtime kh
STO003
h
UL UL UL 508 li st ed / CS A 22 .2 No .1 07.1 3r d Ed . lis t ed
Um we lt Environment
Umgebungstemperatur
Ambient temperature
Lagertemperatur Storage temp erature –2 5° C … +85° C
Kühlart Cooling
Zulässige Luftfeuchtigkeit
Allowable humidity
Si ch erh ei t und S ch utz Safety and protection
Prüfspannung HV t es t vol t ag e 4242 Vdc
Ba ua rt
Construction
Schutzart Protection index IP 20 ( na ch EN 605 29) I P 20 (t o EN 60 52 9)
Schutzklasse
Safety class
Anschlusskabel
Conductors
Einsatzbereich
Installation
Rückspeisungsfestigkeit Feedback voltage max . 35 Vdc
Eingangsdaten Input
Eingangsnennspannung Rated input voltage 3/2 x 400 – 500 Vac
Eingangsspannungsbereich
Operating input voltage range
Nennfrequenzbereich
Ra t ed fr equ en cy ra ng e
Ei ng ang sn enn st rom bei 3x 340 Vac
Ra t ed in pu t cur r en t a t 3x 3 40 Vac
Ei ng ang sn enn st rom bei 2x 3 40 Vac
Ra t ed in pu t cur r en t a t 2x 340 Vac
Einschaltstrom (kalt) In-r ush c ur r en t ( co ld) <3 0 A p
Optionale aktive Einschaltstrombegrenzung
Ac tiv e in- r us h cur ren t li mit er, opt ion al
Eingangssicherung intern
Internal fuse
Externe Absicherung (UL-konform)
External protection device (UL-recognised)
Empfohlene externe Absicherung*
Recommended external protection*
Ableitstrom Leakage current ty p. 1 mA
Ne t za usf al lüb er b rü c ku ng be i 400 / 500 Vac
Ma in s dro p co mpe ns a ti on at 400 / 50 0 Va c
Überspannungsschutz
Over voltage protection
Anschlüsse: WAGO Multisteckersystem
Ter m in al s: WAG O mu l ti pl ug syst em
Ausgangsdaten Output
Ausgangsnennspannung
Ra t ed ou tp ut vo lt age
Ausgangsspannungsbereich
Ra t ed ou tp ut vo lt age rang e
Ausgangsnennstrom bei 24 Vdc
Ra t ed ou tp ut cu rr ent at 24 Vdc
Po w er Bo os t (be i Be tri e b vo n 3 Ein ga ngsph as en)
Po w er Bo os t (if oper ati on wi t h 3 in put pha ses )
Dauerh aft zu entne hmender Ausgangsstrom bei Be tri eb vo n nu r 2 E in ga ngs ph as en
Co nti nuo us ou tp ut cu rr ent all owe d i f on ly op era ­te d wit h 2 inp ut ph as e s
Power Boo st (b e i Be tri eb vo n 2 Ei nga ng sp has en )
Power Boo st (i f ope ra tio n wit h 2 input phas es )
Top Bo os t Top Boos t 70 Adc 80 Adc 100 Adc
Strombegrenzung Current limitation ty p. 1, 1 x I
Wirkungsgrad Efficiency ty p. 91 ,7 % ty p. 92 ,9 % t yp . 93, 6 %
m a x . V e r l u s t l e i s t u n g L e e r la u f / N e n n l a s t
ma x . Po wer los s idl in g / nom in al lo ad
Restwelligkeit Residual ripple <7 0 mV pp
Parallelschaltbarkeit Parallel operation ja, zur Leistungserhöhung ye s, fo r inc r ea sed powe r
–2 5° C … +70 ° C, De ra t in g: -3 %/ K > +5 0 ° C
0, 6 Aa c (2 4 Vd c /10 Ad c) 1, 1 Aac (2 4 Vd c/ 20 Ad c) 2, 0 Aac (2 4 Vd c/40 Ad c)
1, 2 Aa c (24 Vd c/10 Ad c) 2 ,1 Aac (24 Vdc /20 Adc ) 2,6 A ac (24 Vd c/ 25 Ad c)
Motorschutzschalter
Ei ns tel l we r t 1,6 A
Ei ns tel lbe r ei ch 1, 6 – 2, 5 A
Motor protection switch
Se tti ng va lu e 1.6 A
Ad ju stm ent ran ge 1. 6 – 2. 5 A
22 ,6 / 51, 5 ms 13 ,2 / 36 ,8 ms 15 ,6 / 42 ,9 ms
20 Adc / 4 s (15 Ad c / 8 s) 40 Adc / 4 s (3 0 Ad c / 8 s) 60 Adc / 4 s (5 0 Ad c / 16 s)
20 Adc / 4 s 25 Adc / 4 s 40 Adc / 4 s
7,8 / 19, 92 W 8, 3 / 34, 1 W 7,0 / 61, 5 W
TH35-Schienenmontage oder Schraubbefestigung
co mpo nen t for mou nti ng on DIN 35 mm ra il s o r sc r ew mo un t in g
EN 6095 0 (S ELV) un d EN 6020 4 (PE LV )
EN 6095 0 (S ELV) an d EN 6020 4 (PE LV )
–25° C … +55° C,
De r at ing: -5 %/ K > +4 5° C
400 Vac ... 500 Vac,
Derat ing: -0,5 Adc/10 Vac >
An lau f bei - 40°C ty pg epr üft
De v ic e sta r t at -4 0 °C ty pe- t es ted
Selbstkühlung durch natürliche Konvektion bei vertikaler Einbaulage
3 x 2, 5 AT 3 x 2, 5 AT 3 x 3, 2 AT
3 x Le i tu n gs sch ut zsc hal te r 6 A, 10 A ode r 16 A, Cha r ak ter ist ik B, C
10 Adc 20 Adc 40 Adc
10 Adc 20 Adc 25 Adc
AN (N at ura l ai r c on vec t io n coo li n g)
5 bi s 96 % rel ati ve Fe uc hte , kei ne Be t au un g zul äs si g
5 to 96 % re lat ive hum idi ty wi t h no de w
gekaps elt, für den Einbau im Schaltsc hrank
enclosed for installation in switching cabinets
vo r be r ei tet für Ge rät e und A nl age n de r Sch utz k la s se I
Zu m Ans ch lus s Ku p fe rka be l mit min. 75 °C ve wen de n.
pr e pa r ed fo r sa fet y cla ss I
Us e Cop pe r Con du c tor s onl y, ra te d 75 °C .
Ei ns atz in B er eic he n mit Ver sch mu tzu n gs gr ad 2
For installation in Pollution Degree 2 environment
340 – 550 Vac (480 – 780 Vdc)
50 Hz – 60 Hz
typ. wie Eingangsnennstromy
ty p. ra t ed inpu t cur ren t
nicht erforderlich
not necessary
3 x Ci rcu it br eak er s 6 A, 10 A or 16 A
Motorschutzschalter
Ei ns tel l we r t 2, 5 A
Ei ns tel lbe r ei ch 2, 5 – 4,0 A
Motor protection switch
Se tti ng va lu e 2.5 A
Ad ju stm ent ran ge 2. 5 – 4. 0 A
du rch Var ist or im P ri mär st rom kre is
th r ou gh va ri sto r in pr im ary cir cui t
WAG O Ser ie 231, max 2, 5 mm ²
WAG O ser ie s 231, ma x . 2. 5 mm²
24 Vd c
22 ,8 – 28 ,8 Vdc
t y p. 1.1 x I
nenn
rated
44 0 Vac
Motorschutzschalter
Ei ns tel l we r t 3, 2 A
Ei ns tel lbe r ei ch 2, 5 – 4,0 A
Motor protection switch
Se tti ng va lu e 3.2 A
Ad ju stm ent ran ge 2. 5 – 4. 0 A
Page 4
Anschlüsse: WAGO Multisteckersystem
Ter m in al s: WAG O mu l ti pl ug syst em
Signalisierung Signaling
LED rot LED re d Fehler, z.B. U
LED gelb (konfigurierbar)
LED yellow (configurable )
LED grün LED gr een U
Aktive Schaltausgänge (konfigurierbar)
Active switched outputs (configurable)
Sc hni t tst ell e Interface RS 23 2
Anschlüsse: WAGO Multisteckersystem
Ter m in al s: WAG O mu l ti pl ug sy st em
Mechanische Daten Mechanical data
Be fes t ig ung
Mounting
Maße B x H x T ***
Dimens ions widt h x height x depth ***
Gewicht Weigh t 1, 0 kg 1, 3 kg 2, 5 kg
Bestellnummern Order numbers
Standard standard PVSL 400/24-10 PVSL 400/24-20 PVSL 400/24-40
mit aktiver Einschaltstrombegrenzung
Ac tiv e in- r us h cur ren t li mit er, opt ion al
* Für DC Eingangsspannung ist eine geeignete DC-Sicherung erforderlich.
* For DC input voltage suitable DC fuse required.
** WAGO Serie 831: Mit Aderendhülse max. 6 mm
** WAGO Series 831: With ferrule max. 6 mm
*** Maße ohne Anschlussstecker, Tiefe T ab Oberkante Tragschiene. *** Dimensions without terminals, depth T from upper edge of DIN rail.
Se r ie 231 max. 2, 5 mm ²
se rie s 23 1 ma x. 2. 5 m m²
< Powe r Goo d: LE D le uch t et Fau lt e. g. U
out
Wa rn ung , z .B . I
> = Po wer Goo d: LE D le uch t et U
out
57 x 127 x 179 mm 77 x 12 7 x 179 mm 12 8 x 12 7 x 205 mm
PVSL 400/24-10B PVSL 400/24-20B PVSL 400/24-40B
2
. Bei feindrähtigen Leitern bitte geeigneten Spleißschutz verwenden.
2
. Please use suitable anti-splaying method for fine-stranded conductors.
Wa rn i ng e.g. I
Se r ie 733 ma x . 0, 5 mm ²
serie s 733 max. 0.5 mm²
Tragschienenmontage mit zwei Montagemöglichkeiten
ra il mo un tin g wi th tw o pos si ble v ar i et ies
Serie 831 max. 10,0 mm² **
serie s 831 max. 10.0 mm² **
: LE D leu cht e t
> I
nenn
out
> I
out
rated
out
24 Vd c/max . 25 mA
out
: LE D lig ht s
> = Po wer Goo d: LE D li ght s
< Powe r Goo d: LE D li gh ts
Fehler/Warnungen
Faults/warnings
Diese Fehler oder Warnungen können von der Stromversorgung detektiert werden und über die Signalausgänge oder über die Schnittstelle ausgewertet werden. Auch am Gerät selbst lässt sich eine Fehlerdiagnose durch den Fehlermanager durchführen.
These faults or warnings can be detected by the power supply, to be evaluated through the signal output interface. Also di r ectly on th e uni t , fault s ca n be di a gno ­se d wi th the he lp of the fa ult ma nag e r.
Eingangsspannung zu hoch
to o hi gh
U
in
Eingangsspannung zu niedrig
to o hi gh
U
in
Ei ng ang sf req uen z zu ho ch (> 66 Hz )
Fr e qu enc y t oo hi gh (> 66 Hz )
Ei ng ang sf req uen z zu ni ed rig (<4 4 H z)
Fr e qu enc y t oo lo w (< 44 Hz )
Anzeige
Display
$!! %!! !$! !%!
Ausfall einer Phase
Single phase failure
Drehfeldrichtung links
Di r ec tio n of ro tat ing fiel d le ft
Gerätefehler
Device fault
Kommunikationsfehler mit Line Monitor
Communication fault
Au sg ang ss t ro m zu ho ch (> I
to o hi gh (> I
U
out
Au sg ang ss pan nu ng un t er Po we r G oo d We rt*
Po w er go od fail ur e*
Netzausfall
Power failure
Segment blink t segment blin ks
*nur über externe Software veränderbar (werkseitig auf 20,4 Vdc)
*w it h ext ern al So f t wa r e mo dif iab le only (f ac tor y set to 20, 4 Vd c)
Funktionsschaltbild
Functional diagram
rated
Anzeige
Display
!!$ !!% &!! '!!
)
NENN
)
!&! !'! !!&
L1 (+)
L2
L3 (-)
PE
optional
Signal outputs
+24V
S1 S2 S3 S4
1 52 63 74 8
BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 . 27283 Verden, Germany [email protected] . block.eu
RS-232
RxPC
TxPC
+24V
0V
+ +
– –
LED (Green): DC OK
LED (Yellow): WARNING
LED (Red): ERROR
block.eu
Technische Änderungen vorbehalten.
Subject to change.