Blizzard Lighting Reanimator User Manual

Page 1
Blizzard Lighting, LLC
www.blizzardlighting.com
Brookfi eld, WI USA
Copyright (c) 2011-12
Page 2
TABLE OF CONTENTS
Reanimator™ DMX Effect Light 1
What’s In The Box? 3 Getting It Out Of The Box 3 Powering Up! 3 Getting A Hold Of Us 3 Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
Features 5 DMX Quick Reference 5 The Reanimator™ Pinup Picture 6
3. Setup 7
Fuse Replacement 7 Connecting A Bunch Of Reanimator™ DMX Effect Lights 7 Data/DMX Cables 7
4. Operating Adjustments 8
Control Panel Menu Structure 8 DMX Mode 8 Master/Slave Mode 8 Sound Active Mode 8 Pattern Playback Adjustments 8 LED display options 8 Troubleshooting 9
5. Appendix 10
Keeping Your Reanimator™ DMX Effect Light As Good As New 10 Returns (Gasp!) 10 Shipping Issues 10 Tech Specs 11
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 2
Page 3
1. GETTING STARTED
What’s In The Box?
• 1 x Reanimator™ DMX Effect Light
• A swell IEC Power cord & DMX cable
• Warranty Card
• This Lovely User Manual
Getting It Out Of The Box
Reanimation. One of mankind’s strangest pursuits. And yet this light xture has nothing whatsoever to do with that. It is, however, a very cool LED animation effect. SO... now that you’ve been Reanimated™, you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition. If anything looks as if it has been damaged in transit, notify the shipper immediately and keep the packing material for inspection. Again, please save the car­ton and all packing materials. If a fi xture must be returned to the fac- tory, it is important that the fi xture be returned in the original factory
box and packing.
Powering Up!
All xtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
AC Voltage Switch - Not all fi xtures have a voltage select switch, so please verify that the fi xture you receive is suitable for your local pow- er supply. See the label on the fi xture or refer to the fi xture’s specifi - cations chart for more information. A fi xture’s listed current rating is its average current draw under normal conditions. Check the fi xture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the line voltage applied. Damage to your fi xture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch. All fi xtures must be
connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something is wrong, just give us a call or send an email. We’ll be happy to help, honest.
Blizzard Lighting W220 N1531 Jericho Ct. Suite E, Waukesha, WI 53186 USA support@blizzardlighting.com | 1.866.493.6025 www.blizzardlighting.com
Page 3
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 4
SAFETY INSTRUCTIONS
• Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the de­cal or rear panel of the fi xture.
• This product is intended for indoor use only.
• To prevent risk of fi re or shock, do not expose fi xture to rain or moisture.
• Make sure there are no fl ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
• ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type.
• ALWAYS secure fi xture using a safety chain. NEVER carry the fi xture by its cord. Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately. NEVER try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized tech­nical assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact Blizzard Lighting at sup­port@blizzardlighting.com.
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 4
Page 5
2. MEET The Reanimator DMX Effect
CONTROL FEATURES
• 13 Channel DMX control
• Adjustable chase speed, length and pattern
• Variable electronic dimmer
• Built-in automated programs via DMX and master/slave
• Built-in sound active programs in standalone and DMX modes
ADDITIONAL FEATURES
• 8x8 matrix of TRI-Color LEDs (192 total LEDs)
• Over 1,000 built in patterns!
• LED control panel for easy programming
• Mounting bracket with adjustable knobs
• Durable aluminum & molded case
• No Frankenstein-like side effects (that we are aware of)
DMX Quick Reference
Channel Values What It Does
1 0 <--> 255 Graphic Selection A (0-255) 2 0 <--> 255 Graphic Selection B (+ 0-255) 3 0 <--> 255 Graphic Selection C (+ 0-255) 4 0 <--> 255 Graphic Selection D (+ 0-255) 5 0 <--> 255 Graphic Selection E (+ 0-255) 6 0 <--> 255 Graphic Selection F (+ 0-255) 7 0 <--> 255 Graphic Selection G (+ 0-255) 8 0 <--> 255 Graphic Selection H (+ 0-255) 9 0 <--> 255 Graphic Selection I (+ 0-255) 10 0 <--> 255 Animation/Loop Length 11 0 <--> 255 Animation Loop Start
0/255 = Full Number Of Patterns Dis­played 1-254 = Begin looping with channel 10 length at pattern #1-254.
12 000 <--> 255 Animation Speed (used when Chan-
nel 13 is in Auto Mode)
13 0
001 <--> 255
Channels 1-9 Active Auto Animation Mode (Channels 10­12 Active)
NOTE: Channels 1-9 are cumulative, IE if channel 1 is set at 255, then channel 2 will increment starting with graphic #257. If 1 and 2 are set at 255, then channel 3 will increment starting with graphic #513, etc.
Page 5
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 6
Figure 1: The Reanimator™ Pin-Up Picture
Reanimation Portal (Lens)
Mounting Bracket & Knob
Tough Aluminum Case
Figure 2: The Rear Connections
Power Switch LED Control Panel
AC Power In/Fuse DMX In DMX Out
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 6
Page 7
3. SETUP
Fuse Replacement
With a fl at head screwdriver, wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power.
Connecting A Bunch of Reanimator™ DMX Effects
You will need a serial data link to run light shows using a DMX-512 controller or to run shows on two or more fi xtures set to sync in mas- ter/slave operating mode. The combined number of channels required by all the fi xtures on a serial data link determines the number of fi x- tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. Also, connecting more than 32 fi xtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal. The maximum recommended cable-run distance is 500 meters (1640 ft). The maximum recommended number of fi xtures on a serial data link is 32 fi xtures.
Data/DMX Cabling
To link fi xtures together you’ll need data cables. You should use data- grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
For instance, Belden© 9841 meets the specifi cations for EIA RS-485 applications. Standard microphone cables will “probably” be OK, but note that they cannot transmit DMX data as reliably over long distanc­es. In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor & shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 7
Page 8
4. OPERATING ADJUSTMENTS
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
1.) Press the <MENU> button until you reach DMX mode, which appears as
A001 on the LED Readout. Use the <ENTER> button then the <UP> and
<DOWN> buttons to choose a channel between
again to confi rm.
1 and 512. Press <ENTER>
Master/Slave Mode (Auto/Sound Active):
Allows you to link up to 32 units together without a controller.
1.) Use standard DMX cables to daisy chain your units together via the DMX con­nector on the rear of the units. It may be necessary to use a terminator at the last fi xture. For more information about terminators, see page 8.
2.) Choose a unit to function as the Master. Select from one of the run modes, RUN1-RUNF or sound activation. The master unit must be the fi rst unit. Finally, chain the units together using DMX cable.
Master
3.) Select slave function by using the <UP>/<DOWN> keys to reach A001 in the menu on the slave units, and they will react in the same as the Master.
Slave
4.) On the master fi xture, use the <UP>/<DOWN>/<MENU> keys to reach RUN1-F/Soud, which allows you to select the Master/Slave mode.
Sound active Auto mode
RUN1-F then <ENTER> to con rm.
A001 then <ENTER> to con rm.
SoUd then <ENTER> to con rm.
RUN1-F then <ENTER> to con rm.
Pattern Playback Adjustments:
Allows you to adjust the playback characteristics of the automatic programs.
Run1 - Run F then <ENTER> to confi rm.
Each program is different. Perhaps you should study them in depth and write a short treatise on the differences. Otherwise, just enjoy them all!
L001-L255 then <ENTER> to confi rm.
Adjusts the number of patterns to display
F001-F255 then <ENTER> to confi rm.
Adjusts the number of frames to display of each animation
P000-P255 then <ENTER> to confi rm.
Animation speed (Slow <--> Fast)
LEon = LED Control Panel remains on LoFF = LED Control Panel shuts off after approximately 30 seconds.
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 8
Page 9
Troubleshooting
Symptom Solution
Fixture Auto­Shut Off
Beam is Dim Check optical system and clean excess dust/grime. Also
No Light Output Check to ensure fi xture is operating under correct mode, IE
Chase Speed Too Fast/Slow
No Power Check fuse, AC cord and circuit for malfunction. Blown Fuse Check AC cord and circuit for damage, verify that moving
Slow Movement Verify that 220V/110V switch is in the correct position, if
No Response to Audio
Check the fan in the fi xture. If it is stopped or moving slower than normal, the unit may have shut itself off due to high heat. This is to protect the fi xture from overheating. Clear the fan of obstructions, or return the unit for service.
ensure that the 220V/110V switch is in the correct position, if applicable.
sound active/auto/DMX/Etc., if applicable. Contact service for more information.
Check to ensure proper setup of speed adjustment.
parts are not restricted and that unit’s ventilation is not obstructed
applicable. Also check that speed channels are set appropri­ately.
Verify that the fi xture is in “Sound Active” mode. Adjust Audio Sensitivity, If Applicable.
Fixture Not Responding / Responding Er­raticly
Intermittant Lamp
Remote Doesn’t Work
Fixture Moving On Its Own
Make sure all connectors are seated properly and securely. Use Only DMX Cables. Install a Terminator. Check all cables for defects. Reset fi xture(s).
Check lamp for properly installation. Relamp, lamp may have reached end of life.
Verify remote control cable is installed properly and securely. Verify remote is correct type (CA-9 or other as applicable.)
Verify proper mode of operation. Is the fi xture in “Auto” mode?
If your problem isn’t listed, or if problems persist,
please contact support: support@blizzardlighting.com.
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 9
Page 10
5. APPENDIX
Keeping Your Reanimator As Good As New
The fi xture you’ve received is a rugged, tough piece of pro lighting equip- ment, and as long as you take care of it, it will take care of you. That said, like anything, you’ll need to take care of it if you want it to operate as designed. You should absolutely keep the fi xture clean, especially if you are using it in an environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks.
Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of light output. Keeping the fans free of dust and debris will keep the fi xture running cool and prevent damage from overheating.
In transit, keep the fi xtures in cases. You wouldn’t throw a prized guitar, drumset, or other piece of expensive gear into a gear trailer without a case, and similarly, you shouldn’t even think about doing it with your shiny new light xtures.
Common sense and taking care of your fi xtures will be the single biggest thing you can do to keep them running at peak performance and let you worry about designing a great light show, putting on a great concert, or maximizing your cli­ent’s satistfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back, or sending a unit in for service. But, like any complex piece of equipment designed and built by humans, once in a while, something doesn’t go as planned. If you fi nd yourself with a fi xture that isn’t behaving like a good little fi xture should, you’ll need to obtain a Return Authori- zation (RA).
Don’t worry, this is easy. Just send an email to support@blizzardlighting.com, and we’ll issue you an RA. Then, you’ll need to send the unit to us using a trackable, pre-paid freight method. We suggest using USPS Priority or UPS. Make sure you carefully pack the fi xture for transit, and whenever possible, use the original box & packing for shipping.
When returning your fi xture for service, be sure to include the following:
1.) Your contact information (Name, Address, Phone Number, Email address).
2.) The RA# issued to you
3.) A brief description of the problem/symptoms.
We will, at our discretion, repair or replace the fi xture. Please remember that any shipping damage which occurs in transit to us is the customer’s responsibil­ity, so pack it well!
Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and must be reported to the carrier immediately upon receipt of the items. Claims must be made within seven (7) days of receipt.
Page 10
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 11
Tech Specs!
Weight & Dimensions
Length 11.25 inches (285 mm) Width 10.5 inches (266 mm) Height 5.85 inches (166 mm) Weight 7.8 lbs (3.5 kg)
Power
Operating Voltage 110-230VAC, 50-60 Hertz Fuse 2A 250V Power Consumption 100W
Light Source
LED 64 x 5mm TRI-Color LED, 60,000 hours
Optical
Projection Angle Approximately 15 degrees
Thermal
Max. Operating Temp. 104 degrees F (40 degrees C) ambient
Control
Protocol USITT DMX-512 DMX Channels 13 Input 3-pin XLR Male Output 3-pin XLR Female
Standalone, Master/Slave, Sound Active,
Other Operating Modes
Color Preset, Standalone color mixing
Turn-Ons
DMX signal, AC power, cool lighting designs
2-year limited warranty, does not cover mal-
Warranty
function caused by damage to LED’s.
Reanimator Manual Rev. A Copyright (c) 2011-12 Blizzard Lighting, LLC
Page 11
Page 12
Enjoy your product!
Our sincerest thanks for your purchase!
--The team @ Blizzard Lighting
Loading...