What’s In The Box? 3
Getting It Out Of The Box 3
Powering Up! 3
Getting A Hold Of Us 3
Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
2. Meet The G60™ Spot 5
Features 5
DMX Quick Reference 5
The G60 Pin-up Picture 6
3. Setup 7
Fuse Replacement 7
Connecting A Bunch Of G60’s™ 7
Data/DMX Cables 7
Cable Connectors 8
3-Pin??? 5-Pin??? Huh? 8
Take It To The Next Level: Setting up DMX Control 8
Fixture Linking (Master/Slave Mode) 9
Mounting/Rigging 9
4. Operating Adjustments 10
The Control Panel 10
Control Panel Menu Structure & Adjustments 10
Setting the pan/tilt to inverting or non-inverting 10
Setting the DMX channel confi guration 10 Master/Slave (“Auto” or “Sound Active”) 10
DMX Mode 10
Gobo Replacement 11
DMX Channel Values In-Depth 12
Troubleshooting 13
5. Appendix 14
A Quick DMX Lesson 14
Keeping Your G60 Spot As Good As New 15
Returns (Gasp!) 15
Shipping Issues 15
Tech Specs 16
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 2
1. GETTING STARTED
What’s In The Box?
• 1 x G60™ Spot
• An Ever-So-Handy Power Cord
• A Sweet Mounting Bracket
• This Lovely User Manual
Getting It Out Of The Box
Congratulations on purchasing a moving head that really hits the spot!
Now that you’ve got your G60, you should carefully unpack the box
and check the contents to ensure that all parts are present and in good
condition. If anything looks as if it has been damaged in transit, notify
the shipper immediately and keep the packing material for inspection.
Again, please save the carton and all packing materials. If a fi xture
must be returned to the factory, it is important that the fi xture be re-
turned in the original factory box and packing.
Powering Up!
All fi xtures must be powered directly off a switched circuit and cannot
be run off a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel is used solely for a 0% to
100% switch.
AC Voltage Switch - Not all fi xtures have a voltage select switch, so
please verify that the fi xture you receive is suitable for your local pow-
er supply. See the label on the fi xture or refer to the fi xture’s specifi -
cations chart for more information. A fi xture’s listed current rating is
its average current draw under normal conditions. Check the fi xture or
device carefully to make sure that if a voltage selection switch exists
that it is set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit
matches the line voltage applied. Damage to your fi xture may
result if the line voltage applied does not match the voltage
indicated on the voltage selector switch. All fi xtures must be
connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something is wrong, just give us a call or send an email.
We’ll be happy to help, honest.
Blizzard Lighting
W220 N1531 Jericho Ct. Suite E, Waukesha, WI 53186 USA
support@blizzardlighting.com | Phone: 866-493.6025
www.blizzardlighting.com
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 3
SAFETY INSTRUCTIONS
• Please keep this User Guide for future use. If you sell the unit to someone
else, be sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that
the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fi xture.
• This product is intended for indoor use only.
• To prevent risk of fi re or shock, do not expose fi xture to rain or moisture.
• Make sure there are no fl ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least
20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are
blocked.
• ALWAYS disconnect from the power source before servicing or replacing fuse
and be sure to replace with same fuse size and type.
• ALWAYS secure fi xture using a safety chain. NEVER carry the fi xture by its
head. Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately.
NEVER try to repair the unit by yourself. Repairs carried out by unskilled people
can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not
open the housing or attempt any repairs yourself. In the unlikely event
your unit may require service, please contact Blizzard Lighting at support@blizzardlighting.com.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 4
2. MEET THE G60™ SPOT
CONTROL FEATURES
15-channel DMX LED moving yoke•
Pan: 540º Tilt: 263º•
Color wheel: 7 colors + white•
Rainbow color spin at variable speeds•
7 interchangeable, rotating, indexing slot-n-lock gobos + open •
7 static gobos (Gobo Wheel #2)•
Ability to layer gobos for multicolor/multi-textured effects.•
Gobo wheel spin at variable speeds•
3-facet rotating prism•
Variable electronic strobe•
Variable electronic dimmer (0 – 100%)•
Remote focus via DMX (2m~infi nity)•
Remote fi xture reset•
Multiple built-in automated & sound activated programs•
User-programmable built-in programs•
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 5
Figure 1: The G60 Pin-Up Picture
Lens
Head/Arms
Carry Handle
Control Panel
Figure 2: The Rear Connections
DMX InDMX Out
Microphone
AC Power / Fuse
LCD
Readout
Power Switch
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 6
3. SETUP
Fuse Replacement
With a fl at head screwdriver, wedge the
fuse holder out of its housing. Remove the
damaged fuse from its holder and replace
with exact same type fuse. Insert the fuse
holder back in its place and reconnect
power.
Connecting A Bunch of G60’s™
You will need a serial data link to run light shows using a DMX-512
controller or to run shows on two or more fi xtures set to sync in mas-
ter/slave operating mode. The combined number of channels required
by all the fi xtures on a serial data link determines the number of fi x-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also, connecting more than 32 fi xtures on one serial data link without
the use of a DMX optically-isolated splitter may result in deterioration
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640
ft). The maximum recommended number of fi xtures on a serial data
link is 32 fi xtures.
Data/DMX Cabling
To link fi xtures together you’ll need data cables. You should use data-
grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 7
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR
connector on the other end. (Duh!)
CAUTION: Do not allow contact between the common and the fi x-
ture’s chassis ground. Grounding the common can cause a ground
loop, and your fi xture may perform erratically. Test cables with an
ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each other.
3-Pin??? 5-Pin??? Huh?!?
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
They are widely available over the internet and from specialty retailers If you’d like to build your own, the
chart below details a proper cable conversion:
Conductor3-Pin Female
(Output)
5-Pin Male
(Input)
Ground/ShieldPin 1Pin 1
DMX Data (-)Pin 2Pin 2
DMX Data (+)Pin 3Pin 3
Not Used.No Connection.No Connection.
Not Used.No Connection.No Connection.
Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the
DMX cable to the female connector (output)
on the controller.
Step 2: Connect the female connector of the
DMX cable to the fi rst fi xture’s male connec-
tor (input). Note: It doesn’t matter which
fi xture address is the fi rst one connected.
We recommend connecting the fi xtures in
terms of their proximity to the controller,
rather than connecting the lowest fi xture
number fi rst, and so on.
Step 3: Connect other fi xtures in the chain
from output to input as above. Place a DMX
terminator on the output of the fi nal fi xture
to ensure best communication.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 8
Fixture Linking (Master/Slave Mode)
1. Connect the (male) 3 pin connector side of the
DMX cable to the output (female) 3 pin connector of
the fi rst fi xture.
2. Connect the end of the cable coming from the
fi rst fi xture which will have a (female) 3 pin connec-
tor to the input connector of the next fi xture con-
sisting of a (male) 3 pin connector. Then, proceed
to connect from the output as stated above to the
input of the following fi xture and so on.
A quick note: Often,
the setup for MasterSlave and Standalone
operation requires that
the fi rst fi xture in the
chain be initialized for
this purpose via either
settings in the control
panel or DIP-switches.
Secondarily, the fi xtures
that follow may also require a slave setting.
Check the “Operating Adjustments” section in this manual for complete instructions for this type of setup and confi guration.
Mounting & Rigging
This fi xture may be mounted in any SAFE position provided there is
enough room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
fi xture using a suitable “C” or “O” type clamp. The clamp should be
rated to hold at least 10x the fi xture’s weight to ensure structural sta-
bility. Do not mount to surfaces with unknown strength, and ensure
properly “rated” rigging is used when mounting fi xutres overhead.
Adjust the angle of the fi xture by loosening both knobs and tilting the fi xture. After fi nding the desired position, retighten both knobs.
• When selecting installation location, take into consideration lamp
replacement access (if applicable) and routine maintenance.
• Safety cables MUST ALWAYS be used.
• Never mount in places where the fi xture will be exposed to rain,
high humidity, extreme temperature changes or restricted ventilation.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 9
4. OPERATING ADJUSTMENTS
The Control Panel
All the goodies and different modes possible with the G60™ are accessed by using the control panel on the front of the fi xture. There are
4 control buttons below the LCD display which allow you to navigate
through the various control panel menus.
Access control panel functions using the four panel buttons located
directly underneath the LCD Display.
The Control Panel LCD Display shows the menu items you select from
the menu map on page #11. When a menu function is selected, the
display will show immediately the fi rst available option for the selected
menu function. To select a menu item, press <MODE>.
Use the <UP> and <DOWN> buttons to navigate the menu map and
menu options. Press the <FUNC> button to access the menu function
currently displayed or to enable a menu option. To return to the previous option or menu without changing the value, press the <MODE>
button.
Control Panel Menu Structure
Main FunctionSelectionWhat It Does...
DMX Address=000 <-> 511Sets the DMX address
MASTER
FOLLOWN/ASets the fi xture in Slave Mode
PAN_R= OFF / =ONReverses the fi xture’s Pan movement
TILT_R= OFF / =ONReverses the fi xture’s Tilt movement
= EFFECT 00Sets the unit in Sound Active Mode
= EFFECT 01Sets the unit in Auto “Fast” Mode
= EFFECT 02Sets the unit in Auto “Slow” Mode
* Indicates the unit is receiving DMX signal
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 10
Gobo Replacement
1) Remove the gobo cover by removing the four screws on the top of the fi xture head.
2) Remove the slot-n-lock gobo from the gobo wheel by lifting up slightly and sliding it out.
3) Using a small tool, pry the tension ring from the gobo holder.
4) Remove the old gobo.
5) Insert the new gobo, and replace in the reverse steps of removal.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Open
Color 1
Color 2
Color 3
Color 4
Color 5
Color 6
Color 7
Color Wheel Scroll (Clockwise, Slow <-> Fast)
Color Wheel Scroll (Counter-Clockwise, Fast <-> Slow)
Gobo Wheel #1
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Color Wheel Scroll (Clockwise, Slow <-> Fast)
Color Wheel Scroll (Counter-Clockwise, Fast <-> Slow)
Gobo Rotation
No function
Gobo Indexing (0 <--> 360 degrees)
Clockwise (Slow <--> Fast)
Counter-clockwise (Slow <-> Fast)
Gobo Wheel #2
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Color Wheel Scroll (Clockwise, Slow <-> Fast)
Color Wheel Scroll (Counter-Clockwise, Fast <-> Slow)
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 12
Troubleshooting
SymptomSolution
Fixture AutoShut Off
Beam is DimCheck optical system and clean excess dust/grime. Also
No Light OutputCheck to ensure fi xture is operating under correct mode, IE
Chase Speed
Too Fast/Slow
No PowerCheck fuse, AC cord and circuit for malfunction.
Blown FuseCheck AC cord and circuit for damage, verify that moving
Slow MovementVerify that 220V/110V switch is in the correct position, if
No Response to
Audio
Check the fan in the fi xture. If it is stopped or moving
slower than normal, the unit may have shut itself off due to
high heat. This is to protect the fi xture from overheating.
Clear the fan of obstructions, or return the unit for service.
ensure that the 220V/110V switch is in the correct position,
if applicable.
sound active/auto/DMX/Etc., if applicable. Contact service
for more information.
Check to ensure proper setup of speed adjustment.
parts are not restricted and that unit’s ventilation is not
obstructed
applicable. Also check that speed channels are set appropriately.
Verify that the fi xture is in “Sound Active” mode.
Adjust Audio Sensitivity, If Applicable.
Fixture Not
Responding /
Responding Erraticly
Intermittant
Lamp
Remote Doesn’t
Work
Fixture Moving
On Its Own
Make sure all connectors are seated properly and securely.
Use Only DMX Cables.
Install a Terminator.
Check all cables for defects.
Reset fi xture(s).
Check lamp for properly installation.
Relamp, lamp may have reached end of life.
Verify remote control cable is installed properly and securely.
Verify remote is correct type (CA-9 or other as applicable.)
Verify proper mode of operation. Is the fi xture in “Auto”
mode?
If your problem isn’t listed, or if problems persist,
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 13
5. APPENDIX
A Quick Lesson On DMX
DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre
Technology (USITT) as a standardized method for connecting lighting consoles to lighting
dimmer modules. It was revised in 1990 and again in 2000 to allow more fl exibility. The
Entertainment Services and Technology Association (ESTA) has since assumed control over
the DMX512 standard. It has also been approved and recognized for ANSI standard classifi cation.
DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common
communications standard used by lighting and related stage equipment.
DMX provides up to 512 control “channels” per data link. Each of these channels was originally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting
console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an
8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb
being completely off while 255 corresponds to the light bulb being fully on.
DMX data is transmitted at 250,000 bits per second using the RS-485 transmission standard over two wires. As with microphone cables, a grounded cable shield is used to prevent
interference with other signals.
There are fi ve pins on a DMX connector: a wire for ground (cable shield), two wires for
“Primary” communication which goes from a DMX source to a DMX receiver, and two wires
for a “Secondary” communication which goes from a DMX receiver back to a DMX source.
Generally, the “Secondary” channel is not used so data fl ows only from sources to receiv-
ers. Hence, most of us are most familiar with DMX-512 as being employer over typical
3-pin “mic cables,” although this does not conform to the defi ned standard.
DMX is connected using a daisy-chain confi guration where the source connects to the input
of the fi rst device, the output of the fi rst device connects to the input of the next device,
and so on. The standard allows for up to 32 devices on a single DMX link.
Each receiving device typically has a means for setting the “starting channel number” that
it will respond to. For example, if two 6-channel fi xtures are used, the fi rst fi xture might
be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next
fi xture would be set to start at channel 7 so it would respond to channels 7 through 12.
The greatest strength of the DMX communications protocol is that it is very simple and
robust. It involves transmitting a reset condition (indicating the start of a new “packet”),
a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As
soon as one packet is fi nished, another can begin with no delay if desired (usually another
follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will
be sent out over and over again. This is a great feature of DMX -- if for some reason the
data is not interpreted the fi rst time around, it will be re-sent shortly.
Not all 512 channels need to be output per packet, and in fact, it is very uncommon to fi nd
all 512 used. The fewer channels are used, the higher the “refresh” rate. It is possible to
get DMX refreshes at around 1000 times per second if only 24 channels are being transmitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per
second.
In summary, since its design and evolution in the 1980’s DMX has become the standard
for lighting control. It is fl exible, robust, and scalable, and its ability to control everything
from dimmer packs to moving lights to foggers to lasers makes it an indispensible tool for
any lighting designer or lighting performer.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 14
Keeping Your G60 As Good As New
The fi xture you’ve received is a rugged, tough piece of pro lighting equip-
ment, and as long as you take care of it, it will take care of you. That said, like
anything, you’ll need to take care of it if you want it to operate as designed.
You should absolutely keep the fi xture clean, especially if you are using it in an
environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled
drinks.
Cleaning the optics routinely with a suitable glass cleaner will greatly improve
the quality of light output. Keeping the fans free of dust and debris will keep
the fi xture running cool and prevent damage from overheating.
In transit, keep the fi xtures in cases. You wouldn’t throw a prized guitar,
drumset, or other piece of expensive gear into a gear trailer without a case,
and similarly, you shouldn’t even think about doing it with your shiny new light
fi xtures.
Common sense and taking care of your fi xtures will be the single biggest thing
you can do to keep them running at peak performance and let you worry about
designing a great light show, putting on a great concert, or maximizing your client’s satistfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry
about sending a defective unit back, or sending a unit in for service. But, like
any complex piece of equipment designed and built by humans, once in a while,
something doesn’t go as planned. If you fi nd yourself with a fi xture that isn’t
behaving like a good little fi xture should, you’ll need to obtain a Return Authori-
zation (RA).
Don’t worry, this is easy. Just send an email to support@blizzardlighting.com,
and we’ll issue you an RA. Then, you’ll need to send the unit to us using a
trackable, pre-paid freight method. We suggest using USPS Priority or UPS.
Make sure you carefully pack the fi xture for transit, and whenever possible, use
the original box & packing for shipping.
When returning your fi xture for service, be sure to include the following:
1.) Your contact information (Name, Address, Phone Number, Email address).
2.) The RA# issued to you
3.) A brief description of the problem/symptoms.
We will, at our discretion, repair or replace the fi xture. Please remember that
any shipping damage which occurs in transit to us is the customer’s responsibility, so pack it well!
Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and
must be reported to the carrier immediately upon receipt of the items.
Claims must be made within seven (7) days of receipt.
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Operating Voltage110-240VAC, 50-60 Hertz (autoranging)
Fuse5A 250V (fast-blow)
Power Consumption160W
Light Source
LED1x60W Luminus CST-90 LED 50,000 hours
Optical
Beam Angle15 degrees
Luminous Intensity27,800 Lux @ 1 m / 6,240 Lux @ 2 m
25mm outside, 22mm image, 1.2mm max
Gobo Size
thickness
Movement Range
Pan540 degrees
Tilt263 degrees
Thermal
Max. Operating Temp.104 degrees F (40 degrees C) ambient
Control
ProtocolUSITT DMX-512
DMX Channels15
Input3-pin XLR Male
Output3-pin XLR Female
Favorite Color
Blue
2-year limited warranty, does not cover mal-
Warranty
function caused by damage to LED’s.
Page 16
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Since I have this big empty space...
I’d like to say thank you, really, for buying our prod-
ucts. It makes me personally very happy to be able
to provide lights to all of you. It’s a cool feeling to
know that I can share my passion with all of you. So
really, thank you.
What? I still have more space?
Then thanks to Bob, Frank, Roy, Joe, Katy, Cindy,
Kay, my parents, your parents, and everyone else!
Since I’ll never have an album I can put these thank
yous in, this will have to do.
OK - quit reading... start brightening!
--Will
Blizzard Lighting
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 17
G60™ Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Page 19
Enjoy your product!
Our sincerest thanks for your purchase!
--The team @ Blizzard Lighting
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.