What’s In The Box? 3
Getting It Out Of The Box 3
Powering Up! 3
Getting A Hold Of Us 3
Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
2. Meet The EM-Pulse™ LED Strobe Fixture 5
Main Features 5
DMX Quick Reference 5
The EM-Pulse™ Pin-up Picture 6
Rear Connections 6
3. Setup 7
Fuse Replacement 7
Connecting A Bunch Of EM-Pulse™ Fixtures 7
Data/DMX Cables 7
Cable Connectors 8
3-Pin??? 5-Pin??? Huh? 8
Take It To The Next Level: Setting up DMX Control 8
Fixture Linking (Master/Slave Mode) 9
Mounting/Rigging 9
4. Operating Adjustments 10
The Control Panel 10
Control Panel Menu Structure 11
DMX Channel Values In-Depth 12
DMX Mode 12
Set the Starting DMX Address 12
Select the DMX Channel Mode 12
Master/Slave Mode 12
Load Default Settings 12
Auto & Standalone Modes 12
Auto Program Speed 12
Temperature 13
Signal Loss Settings 13
LCD Display On/Auto Off 13
Key (Button) Protection Mode 13
Test Mode 13
DMX Values In-Depth 14
Troubleshooting 16
5. Appendix 17
A Quick DMX Lesson 17
Keeping Your EM-Pulse™ As Good As New 18
Returns (Gasp!) 18
Shipping Issues 18
Tech Specs 19
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 2
Page 3
1. GETTING STARTED
What’s In The Box?
• 1 x EM-Pulse™
• 1 x Base Plate w/Bracket Mounting Points
• A Sweet Safety Cable & Set of Mounting Brackets
• An Ever-So-Handy Power Cord
• This Lovely User Manual
Getting It Out Of The Box
Congratulations! You are now the proud owner of one intensely bright, multitalented
strobe xture that is sure blast a ton of fun into your light show! Now that you’ve
got your EM-Pulse™ (or hopefully, EM-Pulse’s!), you should carefully unpack the box
and check the contents to ensure that all parts are present and in good condition. If
anything looks as if it has been damaged in transit, notify the shipper immediately and
keep the packing material for inspection. Again, please save the carton and all packing
materials. If a xture must be returned to the factory, it is important that the xture be
returned in the original factory box and packing.
Powering Up!
All xtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch.
AC Voltage Switch - Not all xtures have a voltage select switch, so please verify that
the xture you receive is suitable for your local power supply. See the label on the
xture or refer to the xture’s specications chart for more information. A xture’s
listed current rating is its average current draw under normal conditions. Check the
xture or device carefully to make sure that if a voltage selection switch exists that it is
set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the line
voltage applied. Damage to your xture may result if the line voltage applied
does not match the voltage indicated on the voltage selector switch. All
xtures must be connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something is wrong, just give us a call. We’ll be happy to help, honest.
Blizzard Lighting
N16 W23390 Stoneridge Dr. Ste E
Waukesha, WI 53188 USA
www.blizzardlighting.com
414-395-8365
Disclaimer: The information and specications contained in this document are subject to change
without notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions
that may appear in this user manual. Blizzard Lighting™ reserves the right to update the existing
document or to create a new document to correct any errors or omissions at any time. You can
download the latest version of this document from www.blizzardlighting.com.
Author:Date:Last Edited:Date:
J. Thomas6/30/2014J. Thomas7/7/2014
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 3
Page 4
SAFETY INSTRUCTIONS
Please note: Certain people with epilepsy and photosensitivity may suffer
a seizure if exposed to ashing or strobe lighting. If strobe lighting is to
be used in a production, warnings should be posted at the front of house
or entrance doors to the theater as well as in a program, if distributed.
Example: “WARNING: Strobe lights are used during this performance.”
• Please keep this User Guide for future use. If you sell the unit to someone else, be
sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that the
line voltage you are connecting to is not higher than that stated on the decal or rear
panel of the xture.
• Make sure there are no ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least 20in
(50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
• ALWAYS disconnect from the power source before servicing or replacing fuse and
be sure to replace with same fuse size and type.
• ALWAYS secure xture using a safety chain. NEVER carry the xture by its cord.
Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately.
NEVER try to repair the unit by yourself. Repairs carried out by unskilled people
can lead to damage or malfunction. Please contact the nearest authorized technical
assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the
housing or attempt any repairs yourself. In the unlikely event your unit may require
service, please go to our website and open a support ticket at www.blizzardlighting.
com/tickets.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 4
Page 5
2. MEET THE EM-PULSE™ LED STROBE FIXTURE
MAIN FEATURES
• Super bright output via 1,452 white SMD LEDs
• Intense built-in strobe programs + random strobe
• 3/9-segment pixel modes can safely be used as wash (max 40% brightness)
• Built-in over heat protection temperature sensor to extend the lamp life
• Variable electronic strobe & 16-bit dimmer
• User adjustable ash rate of 0-30 ashes per second
• Flash duration can be set from 0-650ms in DMX mode
• 7000Hz LED scan rate
• 4-button easy to use LCD control panel menu
• Aluminum mounting bracket with locking knobs + base plate
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 5
Page 6
Figure 1: The EM-Pulse™ Pin-Up Picture
Locking
Knobs
Mounting Bracket
Figure 2: The Rear Connections
Natural Convection
Heat Sink Cooling
AC Power In
1,452 Bright
White LEDs
Durable Cast
Aluminum Housing
Easy-To-Use 4-Button
LCD Control Panel
3/5-Pin
AC Power Out
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
DMX512 In
Page 6
3/5-Pin
DMX512 Out
Page 7
3. SETUP
Fuse Replacement
CAUTION! The EM-Pulse™ utilizes a high-output switch-mode power
supply with an internal fuse. Under normal operating conditions, the
fuse should not require replacement. The fuse is eld replaceable,
however it is an advanced procedure suited to qualied individuals.
Should your EM-Pulse™ fuse require replacement, please contact
Blizzard Lighting for instructions, or to return your unit for service.
Connecting A Bunch of EM-Pulse™ Fixtures
You will need a serial data link to run light shows using a DMX-512
controller or to run shows on two or more xtures set to sync in
master/slave operating mode. The combined number of channels
required by all the xtures on a serial data link determines the number
of xtures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also, connecting more than 32 xtures on one serial data link without
the use of a DMX optically-isolated splitter may result in deterioration of
the digital DMX signal. The maximum recommended cable-run distance
is 500 meters (1640 ft). The maximum recommended number of
xtures on a serial data link is 32 xtures.
Data/DMX Cabling
To link xtures together you’ll need data cables. You should use data-
grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
applications. Standard microphone cables will “probably” be OK, but
note that they cannot transmit DMX data as reliably over long distances.
In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 7
Page 8
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR
connector on the other end. (Duh!)
CAUTION: Do not allow contact between the common and the
xture’s chassis ground. Grounding the common can cause a ground
loop, and your xture may perform erratically. Test cables with an
ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each other.
3-Pin??? 5-Pin??? Huh?!?
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
They are widely available over the internet and from specialty retailers If you’d like to build your own, the
chart below details a proper cable conversion:
Conductor3-Pin Female
(Output)
5-Pin Male
(Input)
Ground/ShieldPin 1Pin 1
DMX Data (-)Pin 2Pin 2
DMX Data (+)Pin 3Pin 3
Not Used.No Connection.No Connection.
Not Used.No Connection.No Connection.
Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the DMX cable to the female connector (output)
on the controller.
Step 2: Connect the female connector of the
DMX cable to the rst xture’s male connector
(input). Note: It doesn’t matter which
xture address is the rst one connected. We
recommend connecting the xtures in terms
of their proximity to the controller, rather than
connecting the lowest xture number rst,
and so on.
Step 3: Connect other xtures in the chain
from output to input as above. Place a DMX
terminator on the output of the nal xture to
ensure best communication.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 8
Page 9
Fixture Linking (Master/Slave Mode)
1. Connect the (male) 3 pin connector side of the
DMX cable to the output (female) 3 pin connector of
the rst xture.
2. Connect the end of the cable coming from
the rst xture which will have a (female) 3 pin
connector to the input connector of the next xture
consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above
to the input of the following xture and so on.
A quick note:
Often, the setup for
Master-Slave and
Standalone operation
requires that the
rst xture in the
chain be initialized
for this purpose via
either settings in
the control panel
or DIP-switches.
Secondarily, the
xtures that follow
may also require a
slave setting.
Check the “Operating Adjustments” section in this manual for
complete instructions for this type of setup and conguration.
Mounting & Rigging
This xture may be mounted in any SAFE position provided there is
enough room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
xture using a suitable “C” or “O” type clamp. The clamp should be
rated to hold at least 10x the xture’s weight to ensure structural
stability. Do not mount to surfaces with unknown strength, and ensure
properly “rated” rigging is used when mounting xutres overhead.
Adjust the angle of the xture by loosening both knobs and tilting the
xture. After nding the desired position, retighten both knobs.
• When selecting installation location, take into consideration lamp
replacement access (if applicable) and routine maintenance.
• Safety cables MUST ALWAYS be used.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 9
Page 10
4. OPERATING ADJUSTMENTS
The Control Panel
All the goodies and different modes possible with the EM-Pulse™ are
accessed by using the control panel on the front of the xture. There
are 4 control buttons below the LCD display which allow you to navigate through the various control panel menus.
ButtonFunction
<ESC>
Used to access the menu or return to a previous menu option.
<DOWN>
<UP>
<ENTER>
Scrolls through menu options in descending order.
Scrolls through menu options in ascending order.
Used to store the current menu or option within a menu.
The LCD control panel display shows the menu items you select from
the menu map on page #11. When a menu function is selected, the
display will show immediately the rst available option for the selected
menu function. To select a menu item, press <ENTER>.
To navigate through the LCD control panel, use the <UP/DOWN>
buttons to scroll through the menu options. Press the <ENTER> button,
then use the <UP/DOWN> buttons to view any sub-menu options.
Press <ESC> to continue without saving, or press <ENTER> button,
then the <ESC> to save and return to the previous menu item.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 10
Page 11
Control Panel Menu Structure
MenuSub-menu
AddressSet DMX Address001-512
AutoMode 1Auto Mode 1
Mode 2Auto Mode 2
Mode 3Auto Mode 3
Mode 4Auto Mode 4
Mode 5Auto Mode 5
Speed000-031Auto Run Speed
Test LEDAll ONAll On + Individual LED Segment
White 1 ON
White 2 ON
White 3 ON
White 4 ON
White 5 ON
White 6 ON
White 7 ON
White 8 ON
White 9 ON
Temp<ENTER>Internal Temperature
Time<ENTER>Total Run Time
CongDMX StatusValue Hold
Display ModeLCD Display ON or Auto OFF
Channel ModeChannel 1 (1ch DMX mode)
Key ModeKey Lock
Load DefaultResets all values to default
Testing
Holds the last DMX values if signal
is lost.
Value Clear
Clears the DMX values if signal is
lost.
Channel 3 (3ch DMX mode)
Channel 4 (4ch DMX mode)
Channel 6 (6ch DMX mode)
Channel 7 (7ch DMX mode)
Channel 16 (16ch DMX mode)
Pixel 3 (3ch DMX pixel control)
Pixel 9 (9ch DMX pixel control)
Menu buttons lock after 30sec of
inactivity (push more than once to
temporarily unlock buttons).
Key Unlock
Menu buttons are not locked.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 11
Page 12
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
Set the Starting DMX Address:
The default mode for the xture is DMX, so the rst menu item that you can edit is
the starting DMX address.
1.) Press the <UP/DOWN> buttons until you reach Address.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select a channel from 001-512.
4.) Press the <ENTER> button to conrm.
5.) Press the <ESC> button to return to the main menu.
Select the DMX Channel Mode:
1.) Press the <UP/DOWN> buttons until you reach Cong.
2.) Push the <ENTER> button.
3.) Using the <UP/DOWN> buttons, highlight DMX Mode, then press <ENTER>.
4.) Use the <UP/DOWN> buttons to select 1, 3, 4, 6, 7, 16, or 3/9 pixel modes.
5.) Press <ENTER>, and then press the <ESC> button until you reach the
Address screen.
Master/Slave Mode:
1.) Disconnect xture(s) from any DMX signal source.
2.) Set each xture to matching DMX modes.
3.) Connect all xtures together via DMX. The rst xture in the DMX chain will be
the master, followed by the slave xtures.
4.) Connect DMX controller to the master unit for DMX control.
Load Default Settings:
1.) Press the <UP/DOWN> buttons until you reach Load Default.
2.) Push the <ENTER> button.
Auto & Standalone Modes:
Allows a single or Master/Slaved units to run factory installed programs at user selectable
speeds.
Auto Mode:
1.) Press the <UP/DOWN> buttons until you reach Auto.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select from Mode 1 to Mode 5.
4.) Press the <ENTER> button to conrm.
Auto Program Speed:
1.) Press the <UP/DOWN> buttons until you reach Speed.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select from 000-031.
4.) Press the <ENTER> button to conrm.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 12
Page 13
Additional Features:
Never thought you would ever see so many nifty neato features in a strobe light did you?
Temperature:
IMPORTANT - Brightness will decrease when the LED temperature rises over 55ºC.
If a temperature of +70ºC is reached, the overheat protection sensor will activate,
initiating blackout until a safe temperature is reached. It’s highly recommended
to not use the LEDs at full strobe brightness for longer than a 1 minute
period. You can safely use the xture as a normal wash in 3/9 pixel modes
which are programmed to achieve a max of 40% strobe brightness.
1.) Press the <UP/DOWN> buttons until you reach Temp.
2.) Push the <ENTER> button.
3.) The display will show the current temperature in Celsius degrees.
Signal Loss Settings:
In the event of DMX signal loss, you can set the xture to either hold its last
received DMX signal values, or clear them.
1.) Press the <UP/DOWN> buttons until you reach Cong.
2.) Push the <ENTER> button.
3.) Using the <UP/DOWN> buttons, navigate to DMX Status, then press the
<ENTER> button.
4.) Use the <UP/DOWN> buttons to select either Value Hold, or Value Clear.
5.) Press the <ENTER> button to conrm.
LCD Display On/Auto Off:
Display mode On will keep the LCD illuminated continually, Auto will shut the display
off after 30 seconds of inactivity.
1.) Press the <UP/DOWN> buttons until you reach Cong.
2.) Push the <ENTER> button, and navigate to Display Mode.
3.) Push the <ENTER> button, then select either On or Auto, and press the
<ENTER> button.
Key (Button) Protection Mode:
With Key Lock active, buttons will be unresponsive to any initial button press after
30 seconds of inactivity. Temporary unlock will occur with more than 1 button
press. To disable this feature, activate Key Unlock.
1.) Press the <UP/DOWN> buttons until you reach Cong.
2.) Push the <ENTER> button.
3.) Press the <UP/DOWN> buttons until you reach Key Mode, then press
<ENTER>.
4.) Use the <UP/DOWN> buttons to select either Key Lock, or Key Unlock, and
press the <ENTER> button.
Test Mode:
1.) Press the <UP/DOWN> buttons until you reach Test LED.
2.) Push the <ENTER> button.
3.) Now, you can choose to test all of the LEDs at once, or individually test each
of its 9 segments. Use the <UP/DOWN> buttons to navigate, and press the
<ENTER> to conrm.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
No function
Ramp up effect (slow <--> fast)
Ramp down effect (slow <--> fast)
Ramp up-down effect (slow <--> fast)
Random effect (slow <--> fast)
Lightning effect (slow <--> fast)
Spike effect
DMX Values In-Depth (3-Channel Mode)
Ch.ValueWhat It Does
1000 <--> 255Dimmer (0% <--> 100%)
2000 <--> 255Flash Duration (0% <--> 100%)
3000 <--> 255Strobe Rate (0-30Hz)
DMX Values In-Depth (1-Channel Mode)
Ch.ValueWhat It Does
1000 <--> 255Strobe Rate (0-30Hz)
DMX Values In-Depth (3-Channel Pixel Mode)
Ch.ValueWhat It Does
1000 <--> 005
006 <--> 255
2000 <--> 005
006 <--> 255
3000 <--> 005
006 <--> 255
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
No Function
Segment 1-3 Intensity (0% <--> 100%)
No Function
Segment 4-6 Intensity (0% <--> 100%)
No Function
Segment 7-9 Intensity (0% <--> 100%)
Page 15
Page 16
DMX Values In-Depth (9-Channel Pixel Mode)
Ch.ValueWhat It Does
1000 <--> 005
006 <--> 255
2000 <--> 005
006 <--> 255
3000 <--> 005
006 <--> 255
4000 <--> 005
006 <--> 255
5000 <--> 005
006 <--> 255
6000 <--> 005
006 <--> 255
7000 <--> 005
006 <--> 255
8000 <--> 005
006 <--> 255
9000 <--> 005
006 <--> 255
No Function
Segment 1 Intensity (0% <--> 100%)
No Function
Segment 2 Intensity (0% <--> 100%)
No Function
Segment 3 Intensity (0% <--> 100%)
No Function
Segment 4 Intensity (0% <--> 100%)
No Function
Segment 5 Intensity (0% <--> 100%)
No Function
Segment 6 Intensity (0% <--> 100%)
No Function
Segment 7 Intensity (0% <--> 100%)
No Function
Segment 8 Intensity (0% <--> 100%)
No Function
Segment 9 Intensity (0% <--> 100%)
Troubleshooting
SymptomSolution
Fixture AutoShut Off
No Light Output Check to ensure xture is operating under correct mode, IE
Chase Speed
Too Fast/Slow
No PowerCheck fuse, AC cord and circuit for malfunction.
Blown FuseCheck AC cord and circuit for damage, verify that moving
Slow Movement Check that speed channels are set appropriately.
Fixture Not
Responding /
Responding Erratically
Fixture Moving
On Its Own
If it is stopped or dimmer than normal, the unit may have
shut itself off due to high heat. This is to protect the xture
from overheating.
sound active/auto/DMX/Etc., if applicable.
Check to ensure proper setup of speed adjustment.
parts are not restricted and that unit’s ventilation is not
obstructed
Make sure all connectors are seated properly and securely.
Use Only DMX Cables and/or check cables for defects
Install a Terminator.
Reset xture(s).
Verify proper mode of operation. Is the xture in “Auto”
mode?
If your problem persists or isn’t listed, please contact us by
using our online support system: www.blizzardlighting.com/tickets.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 16
Page 17
5. APPENDIX
A Quick Lesson On DMX
DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre
Technology (USITT) as a standardized method for connecting lighting consoles to lighting
dimmer modules. It was revised in 1990 and again in 2000 to allow more exibility. The
Entertainment Services and Technology Association (ESTA) has since assumed control over
the DMX512 standard. It has also been approved and recognized for ANSI standard clas-
sication.
DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common
communications standard used by lighting and related stage equipment.
DMX provides up to 512 control “channels” per data link. Each of these channels was originally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting
console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an
8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb
being completely off while 255 corresponds to the light bulb being fully on.
DMX data is transmitted at 250,000 bits per second using the RS-485 transmission standard over two wires. As with microphone cables, a grounded cable shield is used to prevent
interference with other signals.
There are ve pins on a DMX connector: a wire for ground (cable shield), two wires for
“Primary” communication which goes from a DMX source to a DMX receiver, and two wires
for a “Secondary” communication which goes from a DMX receiver back to a DMX source.
Generally, the “Secondary” channel is not used so data ows only from sources to receivers. Hence, most of us are most familiar with DMX-512 as being employer over typical
3-pin “mic cables,” although this does not conform to the dened standard.
DMX is connected using a daisy-chain conguration where the source connects to the input
of the rst device, the output of the rst device connects to the input of the next device,
and so on. The standard allows for up to 32 devices on a single DMX link.
Each receiving device typically has a means for setting the “starting channel number” that
it will respond to. For example, if two 6-channel xtures are used, the rst xture might
be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next
xture would be set to start at channel 7 so it would respond to channels 7 through 12.
The greatest strength of the DMX communications protocol is that it is very simple and
robust. It involves transmitting a reset condition (indicating the start of a new “packet”),
a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As
soon as one packet is nished, another can begin with no delay if desired (usually another
follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will
be sent out over and over again. This is a great feature of DMX -- if for some reason the
data is not interpreted the rst time around, it will be re-sent shortly.
Not all 512 channels need to be output per packet, and in fact, it is very uncommon to nd
all 512 used. The fewer channels are used, the higher the “refresh” rate. It is possible to
get DMX refreshes at around 1000 times per second if only 24 channels are being transmitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per
second.
In summary, since its design and evolution in the 1980’s DMX has become the standard
for lighting control. It is exible, robust, and scalable, and its ability to control everything
from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for
any lighting designer or lighting performer.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 17
Page 18
Keeping Your EM-Pulse™ As Good As New
The xture you’ve received is a rugged, tough piece of pro lighting equipment,
and as long as you take care of it, it will take care of you. That said, like
anything, you’ll need to take care of it if you want it to operate as designed.
You should absolutely keep the xture clean, especially if you are using it in an
environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled
drinks.
Cleaning the optics routinely with a suitable glass cleaner will greatly improve
the quality of light output. Keeping the fans free of dust and debris will keep the
xture running cool and prevent damage from overheating.
In transit, keep the xtures in cases. You wouldn’t throw a prized guitar,
drumset, or other piece of expensive gear into a gear trailer without a case,
and similarly, you shouldn’t even think about doing it with your shiny new light
xtures.
Common sense and taking care of your xtures will be the single biggest thing
you can do to keep them running at peak performance and let you worry about
designing a great light show, putting on a great concert, or maximizing your
client’s satisfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry
about sending a defective unit back, or sending a unit in for service. But,
like any complex piece of equipment designed and built by humans, once in a
while, something doesn’t go as planned. If you nd yourself with a xture that
isn’t behaving like a good little xture should, you’ll need to obtain a Return
Authorization (RA).
Don’t worry, this is easy. Just go to our website and open a support ticket at
www.blizzardlighting.com/tickets, and we’ll issue you an RA. Then, you’ll need
to send the unit to us using a trackable, pre-paid freight method. We suggest
using USPS Priority or UPS. Make sure you carefully pack the xture for transit,
and whenever possible, use the original box & packing for shipping.
When returning your xture for service, be sure to include the following:
1.) Your contact information (Name, Address, Phone Number, Email address).
2.) The RA# issued to you
3.) A brief description of the problem/symptoms.
We will, at our discretion, repair or replace the xture. Please remember
that any shipping damage which occurs in transit to us is the customer’s
responsibility, so pack it well!
Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and
must be reported to the carrier immediately upon receipt of the items.
Claims must be made within seven (7) days of receipt.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
Page 18
Page 19
Tech Specs!
Weight & Dimensions
Width17.8 in (45 cm), Base: 15.7 in (39.8 cm)
Depth3 in (7.4 cm), Base: 6.3 in (15.8 cm)
Height11.25 in (28.6 cm)
Weight16.5 lbs (7.5 kg)
Power
Operating Voltage100-240VAC 50/60Hz
Power Consumption 300W Max, 3.74A, pf: .67
Light Source
LED1,452 white SMD LEDs, 50,000 hrs.
Optical
Beam Angle120 degree
Luminous Intensity9,300 Lux@ 1m, 2,300 Lux @ 2m
Thermal
Max. Operating
Temp.
104 degrees F (40 degrees C) ambient
Control
ProtocolUSITT DMX-512
DMX Channels1/3/4/6/7/9/16 Channels
Input3/5-pin XLR Male
Output3/5-pin XLR Female
Operating ModesStandalone, Master/Slave, Auto Mode
Other Information
A lot of things look cooler in slow motion. Eating isn’t one of them.
Warranty
DISCLAIMER:
The power connector tted to the xture and xture cord are designed for compatibility
with products manufactured by Neutrik AG, Neutrik USA and their related entities, how-
ever they are not manufactured by, afliated with or endorsed by Neutrik AG, Neutrik
USA, or any related entity. Neutrik® and powerCON® are registered trademarks of
Neutrik AG.
EM-Pulse User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
2-year limited warranty, does not cover malfunction
caused by damage to LED’s.
Page 19
Page 20
Enjoy your product!
Our sincerest thanks for your purchase!
--The team @ Blizzard Lighting
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.