Blizzard Lighting AW RockLite User Manual

ROCKLITE AW
Blizzard Lighting, LLC
www.blizzardlighting.com
Waukesha, WI USA
Copyright (c) 2010-14
TABLE OF CONTENTS
1. Getting Started 3
What’s In The Box? 3 Getting It Out Of The Box 3 Powering Up! 3 Getting A Hold Of Us 3 Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
2. Meet The ROCKLITE™ AW LED 5
Features 5 DMX Quick Reference 5
The ROCKLITE Pin-up Picture 6
3. Setup 7
Fuse Replacement 7 Connecting A Bunch Of ROCKLITE™ AW PAR Cans 7 Data/DMX Cables 7 Cable Connectors 8 3-Pin??? 5-Pin??? Huh? 8 Take It To The Next Level: Setting up DMX Control 8 Fixture Linking (Master/Slave Mode) 9 Mounting/Rigging 9
4. Operating Adjustments 10
Navigating The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Master/Slave Mode 12 Sound Active Mode 12 Standalone (Program) Mode 12 Manual Color Adjustment 12 DMX Channel Values In-Depth 13 Troubleshooting 14
5. Appendix 15
A Quick DMX Lesson 15 Keeping Your ROCKLITE As Good As New 16 Returns (Gasp!) 16 Shipping Issues 16 Tech Specs 17
ROCKLITE AW Manual Rev. B © 2010-14 Blizzard Lighting, LLC
Page 2
1. GETTING STARTED
What’s In The Box?
• 1 x ROCKLITE™ AW Professional LED PAR Fixture
• This Lovely User Manual
Getting It Out Of The Box
Congratulations on purchasing one of the brightest, most rockworthy PAR xtures any­where! Now that you’ve got your ROCKLITE™ (or hopefully, ROCKLITES!), you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition. If anything looks as if it has been damaged in transit, notify the shipper immediately and keep the packing material for inspection. Again, please save
the carton and all packing materials. If a xture must be returned to the factory, it is important that the xture be returned in the original factory box and packing.
Powering Up!
All xtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
AC Voltage Switch - Not all xtures have a voltage select switch, so please verify that the xture you receive is suitable for your local power supply. See the label on the xture or refer to the xture’s specications chart for more information. A xture’s
listed current rating is its average current draw under normal conditions. Check the
xture or device carefully to make sure that if a voltage selection switch exists that it is
set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the line
voltage applied. Damage to your xture may result if the line voltage applied
does not match the voltage indicated on the voltage selector switch. All
xtures must be connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something is wrong, just give us a call or send an email. We’ll be happy to help, honest.
Blizzard Lighting W220 N1531 Jericho Ct. Ste E Waukesha, WI 53188 USA www.blizzardlighting.com 414-395-8365 Email: support@blizzardlighting.com
Disclaimer: The information and specications contained in this document are subject
to change without notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may appear in this user manual. Blizzard Lighting™ reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time. You can download the latest version of this document from www.blizzardlighting.com.
Author: Date: Last Edited: Date:
W. Komassa 5/24/2011 J. Thomas 1/24/2014
ROCKLITE AW Manual Rev. B © 2010-14 Blizzard Lighting, LLC
Page 3
SAFETY INSTRUCTIONS
• Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the de-
cal or rear panel of the xture.
• This product is intended for indoor use only.
• To prevent risk of re or shock, do not expose xture to rain or moisture.
• Make sure there are no ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
• ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type.
• ALWAYS secure xture using a safety chain. NEVER carry the xture by its
cord. Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately. NEVER try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized tech­nical assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact Blizzard Lighting at sup­port@blizzardlighting.com.
ROCKLITE AW Manual Rev. B © 2010-14 Blizzard Lighting, LLC
Page 4
2. MEET THE ROCKLITE AW LED PAR
CONTROL FEATURES
• AW tunable white balance via 36x 3W Amber/White LEDs (24 White, 12 Amber)
• Variable electronic strobe
• Variable electronic dimmer
• Built-in color & chase macros via DMX
• Built-in automated programs via master/slave
• Built-in sound active programs
• AW color mixing ability in standalone mode
ADDITIONAL FEATURES
• Rugged and well-built (It hits the gym regularly)
• Light source: 36x 3 watt Edison LEDs
• Internal Fan Cooling
• Dual mounting brackets for positioning exibility
DMX Quick Reference - 8 Channel Mode
Channel What It Does
1 Dimmer
2 Amber Intensity (Segment #1)
3 White Intensity (Segment #1)
4 White Intensity (Segment #2)
5 Amber Intensity (Segment #2)
6 Strobe
7 Built-in Program Speed
8 Built-in Programs
DMX Quick Reference - 4 Channel Mode
Channel What It Does
1 Amber Intensity (Segment #1)
2 White Intensity (Segment #1)
3 White Intensity (Segment #2)
4 Amber Intensity (Segment #2)
ROCKLITE AW Manual Rev. B © 2010-14 Blizzard Lighting, LLC
Page 5
Figure 1: The ROCKLITE™ Pin-Up Picture
High Power AW LEDs
Mounting Yoke & Adjustment/ Locking Knobs
Rolled Aluminum Enclosure
Figure 2: The Rear Connections
LED Control Panel
Grounding Screw
DMX In DMX Out
ROCKLITE AW Manual Rev. B © 2010-14 Blizzard Lighting, LLC