Delivery set ........................................................................................................................................................................................ 3
Technical data .................................................................................................................................................................................. 4
Mounting, connection and setup ....................................................................................................................................... 4
Control ................................................................................................................................................................................................. 7
This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the SE Vento Expert W
unit and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
The information in this user’s manual is correct at the time of the document’s preparation.
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to
incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information
search system or translated into any language in any form without the prior written permission of the Company.
SAFETY REQUIREMENTS
• Please read the user’s manual carefully prior to installing and operating the unit.
• All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical
norms and standards must be observed when installing and operating the unit.
• The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
• Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
• After a careful reading of the manual, keep it for the entire service life of the unit.
• While transferring the unit control, the user’s manual must be turned over to the receiving operator.
UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS
• Disconnect the unit from power mains prior
to any installation operations.
• The unit must be grounded!
• Do not change the power cable length at
your own discretion.
• Do not bend the power cable.
• Avoid damaging the power cable.
• Do not put any foreign objects on the power
cable.
• Do not use damaged equipment or cables
when connecting the unit to power mains.
• Unpack the unit with care.
• While installing the unit, follow the safety
regulations specific to the use of electric
tools.
• Do not lay the power cable of the unit in
close proximity to heating equipment.
• Do not operate the unit outside the
temperature range stated in the user’s
manual.
• Do not operate the unit in aggressive or
explosive environments.
• Do not touch the unit controls with wet
hands.
• Do not carry out the installation and
maintenance operations with wet hands.
• Do not wash the unit with water.
• Protect the electric parts of the unit against
ingress of water.
2
Page 3
SE Vento Expert W
www.blaubergventilatoren.de
• Do not allow children to operate the unit.
• Do not store any explosive or highly
flammable substances in close proximity to
the unit.
• Do not open the unit during operation.
• Do not block the air duct when the unit is
switched on.
• Do not sit on the unit and avoid placing
foreign objects on it.
• Disconnect the unit from power mains prior
to any technical maintenance.
• When the unit generates unusual sounds,
odour, or emits smoke, disconnect it from
power supply and contact the Seller.
• Do not direct the air flow produced by the
unit towards open flame or ignition sources.
• In case of continuous operation of the unit,
periodically check the security of mounting.
• Use the unit only for its intended purpose.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
PURPOSE
Nine-button sensor control panel with integrated Wi-Fi is designed to control the Vento Expert ventilator.
The sensor control panel is compatible with the following ventilator models:
• Vento Expert A30 W V.2
• Vento Expert A50-1 W V.2
• Vento Expert A85-1 W V.2
• Vento Expert A100-1 W V.2
• Vento Expert Duo A30-1 W V.2
THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED
PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT
THE APPROPRIATE TRAINING.
THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED
PERSONNEL AFTER THE APPROPRIATE BRIEFING.
THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED
Supply voltage, 50 (60) Hz [V ]110-230
Maximum current [A] 0.012
Cable type 2х0.35 mm
Temperature range [°C] from +10 up to +45
Humidity range [%] 10-80 (without condensation)
Casing material Plastic
Sensor surface material Glass
SEC class IP30
Weight [g]190
2
86 mm
DIMENSIONS
Control panel
42.5 mm
68 mm
SE Vento Expert W
82 mm
13.5 mm
R 2 mm
60 mm
Wi-Fi data
Standard IEEE 802.11 b/g/n
Frequency band [GHz 2.4]2.4
Transmission power [mW] (dBm)100 (+20)
Network DHCP
WLAN safety WPA, WPA2
MOUNTING, CONNECTION AND SETUP
CUT OFF POWER SUPPLY BEFORE ANY OPERATIONS ARE PERFORMED
THE CONTROL PANEL MUST BE INSTALLED BY A QUALIFIED EXPERT ONLY, PROPERLY
TRAINED AND HAVING THE REQUIRED TOOLS AND MATERIALS
Mounting box
94
mm
34
3
mm
mm
CHOOSING LOCATION FOR CONTROL PANEL INSTALLATION
Examples of wireless alternatives and system operation scenarios
Example 1: direct control panel connection to master ventilator without using a router.
The control panel must be installed within the range of the Wi-Fi access point built into the master ventilator.
Set the ventilator to Wi-Fi access point master mode (see
the ventilator user’s manual).
• Install the control panel within the range of the Wi-Fi
access point built into the ventilator.
• Pair the control panel with the ventilator (see below).
Note: the limitations specific to the number of devices
Master ventilator
(Wi-Fi access point)
Control panel
(Wi-Fi client)
Control panel
(Wi-Fi client)
Mobile device Mobile device
that can be connected to the ventilator in the Wi-Fi
access point mode are detailed in the ventilator user’s
manual.
4
Page 5
SE Vento Expert W
Example 2: connection via a router with a single Wi-Fi access point.
The control panel can be installed outside the range of the Wi-Fi access point built into the master ventilator.
• Connect the router to the access point built into the
Router
(Wi-Fi access point)
router (see the ventilator user’s manual).
• Bring the control panel within the range of the Wi-Fi
access point built into the ventilator.
• Pair the control panel with the ventilator (see below).
• Install the control panels within the range of the
Wi-Fi access point built into the ventilator.
www.blaubergventilatoren.de
Master ventilator
(Wi-Fi access point)
Control panel
(Wi-Fi client)
Control panel
(Wi-Fi client)
Mobile device Mobile device
Example 3: connection via a router connected to several Wi-Fi access points.
Network cable
Master ventilator
(Wi-Fi access point)
Control panel
(Wi-Fi client)
Control panel
(Wi-Fi client)
Control panel
(Wi-Fi client)
Control panel
(Wi-Fi client)
Router
(Wi-Fi access point)
Mobile device Mobile device
Supplementary
Wi-Fi access point
Mobile device Mobile device
• Connect the router to one of the Wi-Fi access points
(see ventilator user’s manual).
• Pair the ventilator with the first group of the panels.
• Connect the ventilator to the other Wi-Fi access point
(see ventilator user’s manual).
• Pair the ventilator with the other group of the panels.
ATTENTION: IRRESPECTIVE OF THE SELECTED CONNECTION PATTERN THE PANEL MUST BE WITHIN THE RANGE OF THE
WIFI ACCESS POINT BUILT INTO THE VENTILATOR DURING THE PARING OF THE CONTROL PANEL WITH THE MASTER
VENTILATOR.
PAIRING CONTROL PANEL WITH MASTER VENTILATOR
1. Set the ventilator to the Setup mode.
For more details see the ventilator user’s manual.
2. Set the control panel to the Setup mode.
Press and hold the
button for at least 5 seconds until the buttons start blinking simultaneously. Pairing success is
confirmed by double blinking of all the control panel buttons. Upon successful pairing the control panel will exit the Setup mode
immediately. If the pairing process fails to complete within 3 minutes, the panel automatically exits the Setup mode without altering
the initial settings.
3. Exit the ventilator Setup mode.
For more details see the ventilator user’s manual.
ATTENTION: THE PAIRING PROCESS MUST BE REPEATED AFTER EVERY CHANGE OF THE WIFI PARAMETERS AND
VENTILATOR PASSWORD SEE VENTILATOR USER’S MANUAL.
5
Page 6
www.blaubergventilatoren.de
1. Install the mounting box.
Installation inside a wall: make a niche in the wall, route the
necessary wires and cables to the control panel mounting
location and secure it in place.
SE Vento Expert W
Installation on a wall surface: route the necessary wires and
cables to the control panel mounting location, drill holes
and secure the box to the wall with self-tapping screws
(purchased separately).
2. Connect the control panel according to the electrical
connections diagram.
3. Use a screwdriver to carefully disengage the latches on the
bottom end of the glass panel and remove it.
110-230 V / 50(60) Hz
NL
4. Fasten the control panel casing to the mounting box with screws.
The screws used for fastening the panel to the mounting box are included with the unit.
5. Secure the glass panel on the casing by pressing until the latches engage the tabs.
6
Page 7
SE Vento Expert W
CONTROL
The master ventilator is controlled by means of the buttons on the touch-sensitive control panel.
Ventilator connection status indicator. The indicator glows steadily while the ventilator connection is live.
These buttons are used to enable/disable the ventilator, and select speed 1, 2 or 3. The buttons remain dark in the
Standby mode. The buttons glow steadily while speed 1, 2 or 3 is enabled. The indicators blink intermittently if the
Manual Speed Setup mode is selected.
This button activates the Heat recovery mode.
This button activates the Ventilation mode.
This button activates the Party mode (speed 3 enabled by the timer set to 4 hours by default) or the Night mode (speed
1 enabled by the timer set to 8 hours by default). To activate the Party mode, press the
press the
The filter contamination indicator activates automatically after 90 hours of unit operation. Respond to the alert by
replacing or cleaning the filters. After replacing filters in all the ventilators reset the filter timer.
To reset the timer, press and hold the
The indicator blinks if the (Master) ventilator connection is down. This button starts to glow steadily in case of an
emergency motor shutdown. To reset the alarm, press and hold the button for 5 seconds. After that all the buttons blink
twice to alert the user that the button can be released.
www.blaubergventilatoren.de
button and then immediately
button. To activate the Night mode, press the button and then immediately press the button.
indicator for 5 seconds until all the buttons blink twice.
7
Page 8
www.blaubergventilatoren.de
B133-2EN-02
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.