The B3100 Series flow monitor is a flexible, durable, easy-to-use
platform for your flow metering applications. Our trusted flow
metering technology now offers a new flow monitor with more
options and features than ever before with the B3100 Series.
APPLICATIONS
The B3100 monitor is suitable for application in a wide variety of
metering needs. A few of the more common industries are:
•Secondary oil recovery applications
•Remediation and reclamation
•Fracture/refracture
•Coal bed methane
•Regulatory compliance and environmental accountability
•Industrial chemicals
•Aggressive chemical processing applications
•Semiconductor manufacturing
•Fertilizer production and dispensing
•Pesticide manufacture
•Liquid batching and water cooling
FEATURES
•Explosion-proof according ATEX, IECEx, FM and CSA c-us
•Rugged 1 in. NPT thread for flow meter mounting
•Data logging to survey information
•USB communication for configuration using a
programming cable
•Modbus RS485 communication option.
•Easy configuration via PC with free downloadable software
•Easy K-factor and engineering unit configuration for
volumetric or mass readings
•Display shows flow rate, total, measuring units and a flow rate
indicating speedometer
•Seven-digit flow rate/total and 11-digit accumulated total
•Easy configuration with clear alphanumerical display
•Bright LED backlight
•Auto backup of settings and running totals
•Power requirements: Loop powered or battery
•Operational temperature – 40…158° F (– 40…70° C)
•Sixteen-point linearization of the flow curve,
with interpolation
•Field operation via through-the-glass keypad
PART NUMBER CONSTRUCTION
Blancett B3100 Display-
Model
Blancett B3100 DisplayB31
Model
Explosion Proof* – Battery
& Loop Power
Mounting
MeterM
Units of Measure
Customer SelectableCS
*For hazardous locations, the monitor must be installed on an
explosion-proof rated meter. To maintain compliance, kit
P/N B280-757 for meter mounting is required.
Z
DSY-DS-02303-EN-01 (April 2017)
Product Data Sheet
Page 2
Specications
SPECIFICATIONS
DimensionsØ 2.56 × 1.77 in. (65 × 45 mm)
Display
Ambient Operating
Temperature
Enclosure
Power Requirements
Sensor Excitation
Terminal Connections Removable plug-in terminal strip; Wire max. 1.5 mm2 and 2.5 mm
Data Protection
Hazardous AreaCSA c-us / FM
Directives and
Standards
Input
Digital Output
Analog Output
Communication
DigitsSeven 0.47 in. (12 mm) and eleven 0.28 in. (7 mm) digits. Various symbols and measuring units
Refresh rateUser definable: 8 times/sec – 30 sec
Speedometer To indicate the actual flow rate, the bar graph range is 0…100% in 20 blocks, each block is 5%
– 40…158° F (– 40…70° C)
SealingSilicone
Control keysThree infra-red keys with operation through-the-glass front window
RatingNEMA 4×, NEMA 7, NEMA 8, NEMA 9, IP66, IP67
TypeDie-cast aluminum Ex d enclosure
Dimensions4.41 × 5.24 × 5.83 in. (112 × 133 × 148 mm) W × H × D
Entry thread2 × 3/4 in. NPT (T1), 1 × 1 in. NPT (T2)
Battery
powered
Loop powered
Long life Lithium battery; lifetime depends on settings and configuration; Up to approx. 3 years
NOTE: The battery can power the backlight for a short time after a keypad touch
Loop powered, analog output; 11…27V DC; Minimum 3.5 mA
NOTE: The loop powered analog output cannot power the backlight
Power supply 9…27V DC; Consumption max. 3W
All power
sources
Terminal S3: 3V DC for pulse signals and 1.2 V DC for coil pickup, I
EEPROM backup of all settings; Backup of running totals every minute; Data retention is 10 years
Configuration settings can be password protected
Class I, Division 1, Grps A, B, C, D
Class II/III, Division 1, Grps E, F, G
Class I, Zone 1, AEx d IIC T6/T5 Gb
Zone 21, Aex tb IIIC T85°C/T100°C Db
EMCEN 61326-1; FCC 47 CFR part 15
LVDEN/IEC 61010-1
ATEX / IECExEN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31
CSACSA 22.2 No. 25, CSA 22.2 No. 30, No. 61010-1-12
RoHSEN 50581
IP & TYPEEN 60529; NEMA 250
FMClass 3600, 3615, 3616, 3810
ULUL 61010-1
Pulse Flow
Meter
Frequency
Coil / sine wave (COIL-HI: 20 mVpp or COIL-LO: 90 mVpp sensitivity selectable), NPN, PNP, reed
switch, NAMUR, active pulse signals 8 or 24V DC
Min. 0 Hz, max. 10k Hz for total and flow rate; Maximum frequency depends on signal type and
internal low-pass filter; For example, a reed switch with low-pass filter: max. frequency 120 Hz
K-Factor0.000010…9,999,999 with variable decimal position
Low-pass filter Available for all pulse signals
External reset total
PulseTransmitting linearized accumulated total
Frequency500 Hz max; Pulse length user-definable from 1 msec to 10 sec
One passive transistor output (NPN), not isolated; 300 mA to 50V @ 77° F (25° C)
GeneralTransmitting linearized flow rate
Galvanically isolated, loop powered 4…20 mA output
Accuracy
12 bit; Error 0.03% @ 68° F (typical 25 ppm/°F); analog output signal can be scaled to
any desired range
Reading display information, reading/writing all configuration settings and data log extraction
Modbus RTU, RS485 2-wire, bus termination without resistor for low power solutions
AddressingMaximum 247 addresses
Baud rate1200, 2400, 4800, 9600, 19K2, 38K4
max. 100 μA
out
2
DSY-DS-02303-EN-01Page 2 April 2017
Page 3
SPECIFICATIONS CONTINUED
Function
Data
Logging
Operational
Interval logs
Daily logsConfigurable time once/twice per day or disable; Max 600 daily logs
Event logs
ExtractionVia USB (CU) or Modbus communications or USB programming cable
Displayed information
Total Digits7 digits
Total UnitsL, m3 US gal, igal, cf, il bbl, kg, ton, US ton, lb or none
Total Decimals0, 1, 2, or 3 NOTE: Total can be reset to zero.
Accumulated Total Digits 11 digits
Accumulated Total Units/
Decimals
Flow Rate Digits7 digits
Flow Rate UnitsmL, L, m3, mg, g, kg, ton, US ton, US gal, igal, Oil bbl, lb, cf, rev, none, scf, nm3, nL or p
Bar graph Speedometer20 blocks,; each block is 5% of total span
Flow Rate Decimals0, 1, 2, or 3
Flow Rate Time Unitssec, min, hr, day
Specications (continued)
Records process data over time with real time clock
Each log contains flow rate, total, accumulated total, time/date stamp and log number
Every: 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 2 hr, 3 hr, 4 hr, 6 hr, 8 hr or disable
Max 1500 interval logs
When settings change (manual/Modbus) restart/power failure, factory reset, cleared total or
error event; Max 724 event logs
Linearized flow rate and/or total; Linearized total and accumulated total; Indicating speedometer
for flow rate; Total can be reset to zero
According to selection for total NOTE: Accumulated total cannot be reset to zero.
ACCESSORIES
Part NumberDescription
B280-757Explosion-proof Meter Mount Kit, 1 in. connections