Blancett 1100 Operating Manual

Magnetic Pick-up
with Preamplifi er
Part No. B220210
Model 1100 and QuikSert
Turbine Flow Meters
INSTALLATION & INSTRUCTION
MANUAL
®
8635 Washington Avenue
Racine, Wisconsin 53406
Toll Free: 800.235.1638
Phone: 262.639.6770 Fax: 262.417.1155
www.blancett.com
INTRODUCTION
The Blancett B220210 Magnetic Pick-up with Preamplifi er was designed to directly replace a standard pick-up within a turbine ow meter when signal amplifi cation is required. The pick-up is a combination of a standard Blancett magnetic pick-up and a solid state electronic preamplifi er in a single stainless steel housing.
OPERATING PRINCIPLE
As fl uid fl ows through the meter the turbine rotates at a speed proportional to the fl uid velocity. As each turbine blade passes through the magnetic fi eld at the base of the pickup, an AC voltage pulse is generated in the pick-up coil. The voltage signal generated by these pulses becomes amplifi ed within the pick-up. The output signal generated from the pick-up is now in the form of a square wave. The frequency of this amplifi ed signal is used to represent the fl ow rate of fl uid passing through the turbine fl ow meter.
Figure 1
Model 1100 fl ow meter
with preamplifi er pick-up and connecting cable
2 Form No. B910-002 07/09