This document is protected by copyright and distributed under licenses restricting its use, copying,
distribution, and decompilation. No part of this document may be reproduced in any form by any
means without prior written authorization of BLADE Network Technologies, Inc. Documentation is
provided “as is” without warranty of any kind, either express or implied, including any kind of
implied or express warranty of non-infringement or the implied warranties of merchantability or
fitness for a particular purpose.
U.S. Government End Users: This document is provided with a “commercial item” as defined by FAR
2.101 (Oct. 1995) and contains “commercial technical data” and “commercial software
documentation” as those terms are used in FAR 12.211-12.212 (Oct. 1995). Government End Users
are authorized to use this documentation only in accordance with those rights and restrictions set forth
herein, consistent with FAR 12.211- 12.212 (Oct. 1995), DFARS 227.7202 (JUN 1995) and DFARS
252.227-7015 (Nov. 1995).
BLADE Network Technologies, Inc. reserves the right to change any products described herein at any
time, and without notice. BLADE Network Technologies, Inc. assumes no responsibility or liability
arising from the use of products described herein, except as expressly agreed to in writing by BLADE
Network Technologies, Inc. The use and purchase of this product does not convey a license under any
patent rights, trademark rights, or any other intellectual property rights of BLADE Network
Technologies, Inc.
BLADE Network Technologies, the BLADE logo, BLADEHarmony, BNT, NMotion, RackSwitch,
Rackonomics, RackSwitch Solution Partner, ServerMobility, SmartConnect and VMready are
trademarks of BLADE Network Technologies. All other names or marks are property of their
respective owners.
Originated in the USA.
2BPP-00007-01, December 2009
Contents
Preface 5
Who Should Use This Book
Related Documentation
How to Get Help
6
5
RackSwitch G8000 Installation
5
Chapter 1: RackSwitch G8000 Description and Specifications
RackSwitch G8000 Features
Switch Components
Hardware Options
Switch Unit
Switch Ports
9
9
9
13
10 Gigabit Ethernet Port Expansion Slots
Switch LEDs
16
Optional Uplink Modules
Technical Specifications
Physical Characteristics
Environmental Specifications
Power Specifications
Ordering Information
21
Chapter 2: Installing the RackSwitch G8000
Required Tools
Package Contents
23
23
Environmental Requirements
Preventing Electric Shock
Preventing Electrostatic Discharge
Installing the RackSwitch G8000 in a Standard Equipment Rack
Installing the RackSwitch G8000 in an iDataPlex Rack
Installing the RackSwitch G8000 in a 4-post Rack
Initializing the RackSwitch G8000
Default Configuration
Configuring an IP Interface
Using the Boot Management Menu
Installing an Optional Uplink Module
7
15
18
19
19
19
20
23
24
24
25
26
28
31
34
35
35
37
38
7
BPP-00007-01, December 2009Contents
3
RackSwitch G8000 Installation
Installing an SFP/SFP+ Transceiver 40
SFP Optical Transceiver
SFP Copper Transceiver
SFP+ Optical Transceiver
Troubleshooting
System LEDs Do Not Light
Port link LED Does Not Light
Temperature Sensor Warning
Switch Does Not Initialize (Boot)
40
41
42
43
43
43
43
44
Appendix A: Safety and Compliance Statements
Safety Messages
Compliance Statements
45
50
45
ContentsBPP-00007-01, December 2009
4
Preface
This Installation Guide provides information and instructions to install a BLADE Network
Technologies RackSwitch G8000. For information about configuration and management of the
switch, refer to your Command Reference and the product release notes.
Who Should Use This Book
This Installation Guide is intended for network installers and system administrators engaged
in configuring and maintaining a network. It assumes that you are familiar with your
RackSwitch G8000, your Web browser, Ethernet concepts, IP addressing, the IEEE 802.1D
Spanning Tree Protocol, and SNMP configuration parameters.
Related Documentation
For documentation about configuring your switch, see the RackSwitch G8000 Application Guide
and Command Reference.
For details about the switch information, statistics, and configuration parameters, see the
RackSwitch G8000 Command Reference.
5
RackSwitch G8000 Installation
How to Get Help
If you need help, service, or technical assistance, call Blade Network Technologies Technical
Support:
US toll free calls: 1-800-414-5268
International calls: 1-408-834-7871
You also can visit our web site at the following address:
http://www.bladenetwork.net
Click the Support tab.
The warranty card received with your product provides details for contacting a customer
support representative. If you are unable to locate this information, please contact your reseller.
Before you call, prepare the following information:
Serial number of the switch unit
Software release version number
Brief description of the problem and the steps you have already taken
Technical support dump information (# show tech-support)
Note – In case of any suspected hardware related defect, immediately call the BLADE
support line to get the issue resolved. There are no field serviceable parts inside the enclosure and
tampering with internal components in an attempt to diagnose hardware or fix defects will void the
warranty and the product will be repaired at the customer’s expense.
6
CHAPTER 1
RackSwitch G8000
Description and Specifications
The RackSwitch G8000 is a rackable aggregation switch with unmatched line-rate Layer 2/3
performance. The G8000 uses a wire-speed, non-blocking switching fabric that provides
simultaneous wire-speed transport of multiple packets at low latency on all ports.
The G8000 contains forty-eight 1GbE ports and up to four optional 10GbE ports. The Gigabit
Ethernet ports are comprised of forty-four 10/100/1000BaseT Ethernet ports and four Small
Form-factor, Pluggable (SFP) slots. The SFP slots can be populated with optical or copper
transceivers. The four optional 10GbE ports are comprised of one or two dual-port uplink modules
(SFP+ or CX4).
This 1U switch is rack mountable in either the horizontal or vertical direction, depending on your
application.
You can manage the switch through the console port, or through a network connection using Telnet,
a Web browser-based interface, or SNMP-based network management software.
RackSwitch G8000 Features
This section provides an overview of RackSwitch G8000 features.
Deterministic port-to-port latency under 3 microseconds with 64B packets
Management Features
Clients
Industry standard command-line interface (ISCLI)
Browser-based Interface (BBI)
BladeHarmony Manager
BPP-00007-01, December 20097
RackSwitch G8000 Installation
Protocols
SNMP v1, v2, v3
Remote Monitoring (RMON)
Network Time Protocol (NTP) support
DHCP
Software upgrades
Dual software images
Upgrade via serial, browser, or TFTP
Software Features
Security
Secure interface login & password
RADIUS and TACACS+
SSH v1, v2
HTTPS Secure Browser-based interface
Wire-speed filtering with Access Control Lists (ACLs)
Layer 2
1024 VLANs (802.1Q), including Private VLANs
Multi-link trunking, compatible with Cisco EtherChannel
LACP (IEEE 802.3ad)
Spanning Tree (802.1D), Multiple Spanning Tree (802.1s), Rapid Spanning Tree (802.1w),
with Fast Uplink Convergence
16K forwarding database entries
Layer 3
Dynamic routing
- RIP v1, v2
- OSPF
- BGP
128 configurable interfaces (static or DHCP)
DHCP Relay
IP forwarding
IGMP Snooping v1, v2, v3
4K ARP entries
IPv6 host management
Quality of Service
802.1p priority queues
Differentiated Services Code Point (DSCP) support
Availability
Layer 2 Failover
VRRP
Chapter 1: RackSwitch G8000 Description and SpecificationsBPP-00007-01, December 2009
8
RackSwitch G8000 Installation
Switch Components
This section describes the RackSwitch G8000 hardware components.
Hardware Options
The following list provides an overview of G8000 hardware:
Switch unit
Mounting hardware
Standard rack mounting brackets and screws
iDataPlex rack mounting brackets and screws
4-post rack mounting brackets and screws
Optional uplink modules (not included with switch unit)
SFP+ uplink module (2 ports)
CX4 uplink module (2 ports)
Switch Unit
The RackSwitch G8000 switch unit is a 1U rack-mountable Gigabit Ethernet switch. You can
mount the G8000 in either the horizontal or vertical direction.
The RackSwitch G8000 allows for flexible mounting of the switch, as follows:
DC powered RackSwitch G8000R provides front-to-rear airflow.
Ports
The switch unit contains forty-eight 1GbE ports, as follows:
Forty-four 10/100/1000BaseT ports (RJ-45)
Four SFP slots
The G8000 includes two port expansion slots for dual-port, 10GbE uplink modules with SFP+ or
CX4 transceivers. One slot is located on the front panel, and one slot is located on the rear panel.
BPP-00007-01, December 2009Chapter 1: RackSwitch G8000 Description and Specifications
9
RackSwitch G8000 Installation
Figure 1 RackSwitch G8000 Front Panel
System status LEDs
2
4
6
3
1
XGE port LEDs
5
IEC 320
Power connector
8
10
7
RJ-45 ports
181920
9
1112131415
16
17
22
21
242526
23
28
27
Figure 2 RackSwitch G8000 Rear Panel
CLEI LABEL
343536
2930313233
MAC ADDRESS
40
373839
IEC 320
Power connector
Port expansion slot
42
44
43
41
45
SFP slots
RS-232 port
Port expansion slot
46
RackSwitch G8000
48
47
SFP slots
Figure 3 RackSwitch DC G8000 Rear Panel
DC Power
connector
RET
GND
-48V
Input 1: 42-56VDC
4A max. @ 48VDC
CLEI LABEL
MAC ADDRESS
DC Power
connector
RET
GND
-48V
Input 1: 42-56VDC
4A max. @ 48VDC
RackSwitch G8000
Port expansion slot
Chapter 1: RackSwitch G8000 Description and SpecificationsBPP-00007-01, December 2009
10
RackSwitch G8000 Installation
Fans
Five internal fans cool the switch unit. If an individual fan fails, the other fans continue to run, and
the switch unit continues to operate normally. Fans are not customer replaceable.
Fan operation and internal temperatures are monitored. If the air temperature exceeds a desired
threshold, the environmental monitor displays warning messages.
Note – If a fan fails, the maximum operating temperature drops from +40ºC to +35ºC.
The Fan LED blinks if there is a failure of one or more fans.
AC Power Supply
The G8000 has two redundant 150W AC power supplies. Each internal power supply has an
individual IEC 320 power connector on the rear panel. The power cord attaches to a universal
grounded AC power source.
Caution—To reduce the risk of electric shock, use only power cords that have a grounding path,
and always connect the power cord to a properly grounded power outlet.
Each power supply can be connected to a separate AC circuit to mitigate the risk of down time
during a power failure. When used in a redundant configuration, the dual power supplies have a
load-sharing capability that allows each supply to operate at approximately 50 percent of full load.
Using redundant power can minimize the power disruption during a power supply failure and
extend the expected lifetime of each supply by operating normally in a conservative power mode.
There is no power switch on the G8000; the switch unit powers up when power is supplied through
the power cord(s).
The Power Supply LED indicates the status of the power supplies. The LED blinks when only one
power cord is connected, and lights steady when both power cords are connected.
BPP-00007-01, December 2009Chapter 1: RackSwitch G8000 Description and Specifications
11
RackSwitch G8000 Installation
DC Power Supply
The DC Powered G8000 has two redundant 160W DC-DC power supplies, operating from
42V to 60V. Each internal power supply has a DC filter input on the rear panel. The DC power
sources are connected to the G8000 via the mating connector cable assemblies provided. One end of
the cable is connected to the G8000 and the three DC-input leads connect the DC-input power
supply to the site power source. The pigtail end of the cable is color coded, as follows:
Black:Negative (-48V)
Red: Positive (return)
Green: Ground
Warning—Only trained and qualified personnel can connect this equipment to the site
power source.
Each power supply can be connected to a separate DC power source to mitigate the risk of down
time during a power failure. When used in a redundant configuration, the dual power supplies have
a load-sharing capability that allows each supply to operate at approximately 50 percent of full load.
Using redundant power can minimize the power disruption during a power supply failure and
extend the expected lifetime of each supply by operating normally in a conservative power mode.
There is no power switch on the G8000; the switch unit powers up when power is supplied through
the DC power source.
The Power Supply LED indicates the status of the power supplies. The LED blinks when only one
DC power source is connected, and lights steady when both DC power sources are connected.
Chapter 1: RackSwitch G8000 Description and SpecificationsBPP-00007-01, December 2009
12
RackSwitch G8000 Installation
Switch Ports
The RackSwitch G8000 switch ports and port options are described below.
10/100/1000Base-T Ports
44 10/100/1000BaseT ports (RJ-45) are located on the front panel. In-line management and Control
Plane Stacking are supported by using one or more of the RJ-45 ports for management.
The G8000 is designed to accept most standard 10/100/1000Base-T (category 5) cables.
The following table describes the RJ-45 connector pin assignments:
Table 1 RJ-45 Port Pin Assignments
Pin numberSignalDescription
1BI DA+Bi-directional data pair A positive
2BI DA-Bi-directional data pair A negative
3BI DB+Bi-directional data pair B positive
4BI DC+Bi-directional data pair C positive
5BI DC-Bi-directional data pair C negative
6BI DB-Bi-directional data pair B negative
7BI DD+Bi-directional data pair D positive
8BI DD-Bi-directional data pair D negative
SFP Slots
Four 1Gbps Small Form-factor Pluggable (SFP) slots are located on the front panel. These slots
accept approved optical or copper SFP transceivers. SFP transceivers are not included with the
G8000 switch unit.
The following SFP transceivers are available from Blade Network Technologies:
Table 2 Recommended SFP Transceivers
Part numberDescription
BN-CKM-S-TSFP 1000Base-T Copper Transceiver
BN-CKM-S-SXSFP 1000Base-SX Short Range Fiber Transceiver
BN-CKM-S-LXSFP 1000BASE-LX Long Range Fiber Transceiver
BPP-00007-01, December 2009Chapter 1: RackSwitch G8000 Description and Specifications
13
RackSwitch G8000 Installation
Console Port
The RS-232 (mini-USB) serial console port is located on the front panel. An external cable is
required to convert to a D9 connector. The following table describes the pinouts for the mini-USB
port:
Table 3 Console Port Pin Assignments
Pin numberFunction
Pin 1
No connect
Pin 2
Pin 3
Pin 4
Pin 5
RS232_SIN
RS232_SOUT
No connect
Ground
The following table describes the wiring of the console cable:
Table 4 Console Cable Wiring
D9
Pin number
Pin 2Black
Pin 3White
Pin 5Green
Pin 1
Pin 4
Pin 6
Pin 7
Pin 8
ShellBraidShell
WireMini-USB
Pin number
Pin 3
Pin 2
Pin 5
D9 Pins 1, 4, and 6 are connected
D9 pin 7 is connected to D9 pin 8
Chapter 1: RackSwitch G8000 Description and SpecificationsBPP-00007-01, December 2009
14
RackSwitch G8000 Installation
10 Gigabit Ethernet Port Expansion Slots
The G8000 switch unit includes two port expansion slots, one on the front panel and one
on the rear panel. Each expansion slot accepts a dual-port 10GbE (XGE) uplink module for either
CX4 or SFP+.
You can add one or two XGE uplink modules, as follows:
SFP+ Uplink Module
Up to four 10Gbps Small Form-factor Pluggable (SFP+) slots can be installed on the G8000. These
slots accept approved optical SFP+ transceivers. SFP+ transceivers are not included with the G8000
switch unit or with the port uplink modules.
The following SFP+ transceivers are available from Blade Network Technologies: SFP+
10GBase-ST Short Range Optical Fiber Transceiver
Table 5 Recommended SFP+ Transceiver
Part numberDescription
BN-CKM-SP-SR
BN-CKM-SP-LRSFP+ 10GBase-LR Long Range Optical Fiber Transceiver
SFP+ 10GBase-SR Short Range Optical Fiber Transceiver
CX4 Uplink Module
Up to four CX4 ports can be installed on the G8000. These ports provide CX4 connectivity between
the G8000 and copper 10GbE CX4 network devices. The CX4 ports support link spans up to 15
meters on appropriate CX4-grade copper cables.
The CX4 ports provide powered CX4 automatically. The port detects when a powered CX4 device
is connected, and sends power to the device.
The G8000 is designed to accept most standard 10GbE CX4 cables.
Note – Do not use InfiniBand CX4 cables with the G8000. Although InfiniBand cables have the
same CX4 connectors as 10GBase-CX4 cables, InfiniBand cables do not adhere to the same
standard as 10GBase-CX4 cables.
BPP-00007-01, December 2009Chapter 1: RackSwitch G8000 Description and Specifications
15
RackSwitch G8000 Installation
Switch LEDs
Two LED stacks provide system status and port link status. The system LEDs are described in the
following table:
Power supplies and AC or DC power input status
Fans status
MB
MS
Stacking master indicator
Stacking member indicator
The following table describes the system LED indications:
Table 6 System LEDs Status
FunctionPower
Supply
Total Power FailureOffOffOffOffOff
Service RequiredBlink GreenBlink GreenBlink GreenBlink GreenBlink Green
Power Supplies OKSolid GreenN/AN/AN/AN/A
Power Supply FailureBlink GreenN/AN/AN/AN/A
Fans OKN/ASolid GreenN/AN/AN/A
Fan FailureN/ABlink GreenN/AN/AN/A
Stack MasterN/AN/AOnOffN/A
Stack Backup/MemberN/AN/AOffOnN/A
Stack ErrorN/AN/AOnOnN/A
Non-Stack MemberN/AN/AOffOffN/A
FanMasterMemberXGE Port
RJ-45 LEDs
Status LEDs for the RJ-45 ports are described in the following table.
Table 7 RJ45 LEDs Status
LEDSolid GreenBlink GreenOff
LinkValid LinkActivityNo Link
Speed100/1000MbpsN/A10Mbps
Chapter 1: RackSwitch G8000 Description and SpecificationsBPP-00007-01, December 2009
16
RackSwitch G8000 Installation
SFP LEDs
Status LEDs for the SFP ports are described in the following table.
Table 8 SFP LEDs Status
LED Solid GreenBlink GreenOff
Port LinkValid LinkN/ANo Link
XGE Link LEDs
Figure 4 highlights the system LEDs and XGE port LEDs.
Figure 4 System Status LEDs and XGE Port LEDs
Rackswitch G8000
XGE
Link
4
3
2
MB
1
MS
Stacking
XGE Link LEDs provide the link status for ports on each of the uplink modules, if applicable.
Optional XGE ports one (port 49) and two (port 50) are located in the uplink module on the front
panel. Optional XGE ports three (port 51) and four (port 52) are located in the uplink module on the
rear panel.
Table 9 XGE Module LEDs Status
LED Solid GreenBlink GreenOff
Port LinkValid LinkN/ANo Link
BPP-00007-01, December 2009Chapter 1: RackSwitch G8000 Description and Specifications