Black & Decker PI100BB User Manual

0 (0)
Black & Decker PI100BB User Manual

INSTRUCTION MANUAL

100 WATT POWER

INVERTER WITH

USB CHARGING

PORT

Catalog Number

PI100BB

Thank you for choosing Black & Decker! Go to www.BlackandDecker.com/NewOwner to register your new product.

PLEASE READ BEFORE RETURNING THIS

PRODUCT FOR ANY REASON:

If you have a question or experience a problem with your Black & Decker purchase, go to

HTTP://WWW.BLACKANDDECKER.COM/INSTANTANSWERS for instant answers 24 hours a day.

If you canʼt find the answer or do not have access to the internet,

call 1-800-544-6986 from 8 a.m. to 5 p.m. EST Mon. -- Fri. to speak with an agent. Please have the catalog number available when you call.

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE.

Catalog # PI100BB

Form # 90565630

July 2010

Copyright © 2010 Black & Decker

 

Printed in China

SAFETY GUIDELINES / DEFINITIONS

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION: Used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in property damage.

RISK OF UNSAFE OPERATION. When using tools or equipment, basic safety precautions should always be followed to reduce the risk of personal injury. Improper operation, maintenance or modification of tools or equipment could result in serious injury and property damage. There are certain applications for which tools and equipment are designed. Black & Decker strongly recommends that this product NOT be modified and/or used for any application other than for which it was designed. Read and understand all warnings and operating instructions before using any tool or equipment.

IMPORTANT SAFETY INSTRUCTIONS

GENERAL SAFETY WARNINGS AND INSTRUCTIONS FOR ALL APPLIANCES

READ ALL INSTRUCTIONS

WARNING: Read all instructions before operating product. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.

AVOID DANGEROUS ENVIRONMENTS. Donʼt use appliances in damp or wet locations. Donʼt use appliances in the rain.

STORE IDLE APPLIANCES INDOORS. When not in use, appliances should be stored indoors in dry, and high or locked-up place – out of reach of children.

DONʼT FORCE APPLIANCE. It will do the job better and with less likelihood of a risk of injury at the rate for which it was designed.

USE RIGHT APPLIANCE. Do not use the appliance for any job except that for which it is intended.

DISCONNECT APPLIANCES. Disconnect the appliance from the power supply when not in use, before servicing, and when changing accessories such as blades and the like.

PROPER COOLING IS ESSENTIAL WHEN OPERATING THE INVERTER. Do not place the unit near the vehicleʼs heat vent or in direct sunlight.

USE OF ACCESSORIES AND ATTACHMENTS. The use of any accessory or attachment not recommended for use with this appliance could be hazardous. Note: Refer to the accessory section of this manual for further details.

CHECK DAMAGED PARTS. A part that is damaged should be properly repaired or replaced by an authorized service center.

OUTDOOR USE EXTENSION CORDS. When an appliance plugged into this unit is used outdoors, use only extension cords intended for use outdoors and so marked. NOTE THAT THIS INVERTER IS NOT INTENDED TO BE USED OUTDOORS.

EXTENSION CORDS. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The following table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Minimum Gauge for Cord Sets

Volts

 

 

Total Length of Cord in Feet

 

120V

 

0-25

26-50

51-100

101-150

 

 

 

(0-7.6m)

(7.6-15.2m)

(15.2-30.4m)

(30.4-45.7m)

240V

 

0-50

51-100

101-200

201-300

Ampere Rating

(0-15.2m)

(15.2-30.4m)

(30.4-60.9m)

(60.9-91.4m)

 

 

 

 

More

Not more

 

American Wire Gauge

 

Than

Than

 

 

 

 

0

-

6

18

16

16

14

6

-

10

18

16

14

12

10 -

12

16

16

14

12

12 -

16

14

12

Not Recommended

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:

Do not connect to AC distribution wiring.

Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED. This includes DC cigarette lighter type plug connection or airplane adapter. This unit is NOT approved for ignition protected areas.

NEVER immerse the unit in water or any other liquid, or use when wet.

Do not insert foreign objects into the AC outlet or the USB outlet.

WARNING: TO REDUCE THE RISK OF FIRE:

• Do not operate near flammable materials, fumes or gases.

• DO NOT expose to extreme heat or flames.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

Remove appliance plug from outlet before working on the appliance.

DO NOT attempt to connect or set up the unit or its components while operating your vehicle. Not paying attention to the road may result in a serious accident.

Always use the inverter where there is adequate ventilation. Do not block ventilation slots.

ALWAYS turn the inverter OFF by disconnecting it from the DC accessory outlet when not in use.

Make sure the nominal powering voltage is 12 volts DC, center connection positive (+).

When using this unit in a vehicle, check the vehicle operaterʼs manual for maximum power rating and recommended output. Do not install in engine compartment — install in a well ventilated area.

Do not use with positive ground electrical systems.* Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will void warranty.

*The majority of modern automobiles, RVs and trucks are negative ground.

Keep in mind that this inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, microwave ovens and toasters.

Do not open the inverter — there are no user-serviceable parts inside.

Do not use this inverter with medical devices. It is not tested for medical applications.

Keep away from children. This is not a toy!

Install and operate unit only as described in this Instruction Manual.

Do not use this inverter on a watercraft. It is not qualified for marine applications.

Check unit periodically for wear and tear. Take to a qualified technician for replacement of worn or defective parts immediately.

Read And Understand This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF INJURY:

Follow these instructions and those published by battery manufacturer and the manufacturer of any equipment you intend to use with this unit. Review cautionary markings on these products and on engine.

INTRODUCTION

Thank you for purchasing the PI100BB Power Inverter with USB Charging Port. This inverter can be used to operate personal electronics and mobile office equipment, such as: laptop computers, digital/video cameras, MP3 players, cell phones, PDAs, and more. It can also be used to recharge 110/120 volt AC devices that have an appropriate recharging adapter with a standard North American two-or three-prong plug.

Please read this Instruction Manual carefully before use to ensure optimum performance and to avoid damage to this product.

INCOMPATIBLE PRODUCTS:

CAUTION:

Certain products contain power supplies or circuits that are not compatible with a inverter using a modified sine wave output (such as this inverter) and may be damaged by using this inverter.

If your product requires pure sine wave AC input power to function properly, the instruction manual for your product could state this. If in doubt, you should contact your product manufacturer PRIOR TO USE.

Some products must be powered from a pure sine wave power source, such as standard household power, or a “pure sine wave” inverter in order to function properly.

Your product could be damaged by this inverter if it contains:

1.Transformer type power supplies

2.Microprocessor controlled power supplies

3.Capacitive coupled power supplies

If an incompatible product is used with this inverter:

The product might not operate at all, with no indication of failure. The product fuse might have opened as a result of trying to use it with the inverter.

The product exhibits unusual operation (such as, intermittent operation, buzzing, and the like.)

WARNING: If the product does not operate normally, to reduce the risk of injury or property damage:

Turn the product off immediately and unplug it from the inverter.

FEATURES

100 watts continuous output*

5 volt DC USB Charging Port

Easiest inverter to use – truly plug and play

Tri-color Power/Fault LED Indicator

Compact, efficient and quiet

Electronic circuit protection prevents damage due to overload/insufficient ventilation (overheat condition)

Low-battery shutdown

*Refer to the “Specifications” section

Controls and Functions

 

12 VOLT DC VEHICLE ADAPTER

THREE-PRONG 115 VOLT AC OUTLET

PLUG

POWER/FAULT

 

LED INDICATOR

POWER PLUG ADJUSTS 90°

USB CHARGING PORT

HOW THIS INVERTER WORKS

This inverter is an electronic device that converts low voltage DC (direct current) electricity from a battery to 115 volts AC (alternating current) household power. In designing this inverter, Black & Decker has incorporated design techniques previously employed in computer power supplies. The result of these design innovations is a smaller, lighter and easier-to-use power inverter.

The Power Inverter converts power in two stages. The first stage is a DC-to-DC conversion process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage is a MOSFET bridge stage that converts the high voltage DC into 115 volts, 60 Hz AC.

The DC-to-DC inverter stage uses creative, high frequency, zero voltage switching power conversion techniques that replace the bulky transformers found in less technologically advanced models. The inverter stage uses advanced power MOSFET transistors in a full bridge configuration.

Power Inverter Output Waveform

NOTICE: THE OUTPUT OF THIS DEVICE IS NOT SINUSOIDAL. IT HAS A TOTAL HARMONIC DISTORTION OF 38 PER CENT AND MAXIMUM SINGLE HARMONIC OF 32 PER CENT AT 25% RATED LOAD.

The AC output waveform of this inverter is known as a modified sine wave. It is a stepped waveform that has characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic equipment, transformers, and small motors.

The modified sine wave produced by this inverter has an RMS (root mean square) voltage of 115 volts. Most AC voltmeters (both digital and analog) are sensitive to the average value of the waveform rather than the RMS value. They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave. These meters will not correctly read the RMS voltage of a modified sine wave. Non-TRUE RMS meters will read about 20 to 30 volts low when measuring the output of this inverter. For accurate measurement of the output voltage of this unit, use a TRUE RMS reading voltmeter such as a Fluke 87, Fluke 8080A, Beckman 4410 or Triplett 4200.

115 Volt AC Output

CAUTION — RECHARGEABLE DEVICES

Certain rechargeable devices are designed to be charged by plugging them directly into an AC receptacle. These devices may damage the inverter or the charging circuit.

If there is any sign that your appliance is behaving differently to that when connected to the normal power source then unplug and seek advice from your appliance manufacturer.

This problem does not occur with most of the battery-operated equipment. Most of these devices use a separate charger or transformer that is plugged into an AC receptacle.

The inverter is capable of running most chargers and transformers.

OPERATING INSTRUCTIONS

The Power/Fault LED Indicator lights green when the inverter is properly connected to a functioning DC power source. The AC and USB outlets are ready to use. (If the Power/Fault LED Indicator lights red, refer to the Troubleshooting Section of this Instruction Manual.)

To turn the unit off, disconnect it from the 12 volt DC power source.

Always connect the inverter to the 12 volt DC power source before plugging any devices into the unit.

The standard North American 115 volt AC and USB outlets allow simultaneous operation of multiple devices. Simply plug the equipment into the unit and operate normally. Ensure that the wattage of all equipment simultaneously plugged into the inverter does not exceed 100 watts continuous.

Rated Versus Actual Current Draw of Equipment

Most electrical tools, appliances, electronic devices and audio/visual equipment have labels that indicate the power consumption in amps or watts. Be sure that the power consumption of the item to be operated is below 100 watts. If the power consumption is rated in amps AC, simply multiply by the AC volts (115) to determine the wattage.

Resistive loads are the easiest for the inverter to run; however, it will not run larger resistive loads (such as electric stoves and heaters), which require far more wattage than the inverter can deliver. Inductive loads (such as TVs and stereos) require more current to operate than do resistive loads of the same wattage rating.

For safety reasons, the unit will simply shut down if it is overloaded. To restart the unit, simply remove the load, wait a few minutes, then plug it back in, rotating slightly to make sure there is good contact.

Operation of the 115 Volt AC Outlet - Figure A

1.Connect the unit to a vehicleʼs

 

 

 

 

 

 

 

 

 

 

 

 

 

accessory outlet or other 12 volt DC

A

 

 

 

 

 

 

 

 

 

 

 

 

power source. Make sure there is

 

 

 

 

 

 

 

 

 

 

 

 

 

adequate space for proper ventilation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the inverter (figure A).

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Rotate the unit slightly to make sure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

there is good contact.

 

 

 

 

 

 

 

 

 

 

 

 

 

3.The Power/Fault LED Indicator will light

 

 

 

 

 

 

 

 

 

 

 

 

 

green, indicating a proper connection. If

 

 

 

 

 

 

 

 

 

 

 

 

 

the Power/Fault LED Indicator lights

 

 

 

 

 

 

 

 

 

 

 

 

 

red, a Fault condition exists. Refer to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Troubleshooting Section of this

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

4.If the inverter does not work, make sure

 

 

 

 

 

 

 

 

 

 

 

 

 

the ignition/accessory outlet is powering

 

 

 

 

 

 

 

 

 

 

 

 

 

the accessory outlet. Some vehicles

 

 

 

 

 

 

 

 

 

 

 

 

 

require the ignition switch to be turned

 

 

 

 

 

 

 

 

 

 

 

 

 

on.

 

 

 

 

 

 

 

 

 

 

 

 

 

5.Plug the (110/120 volt AC) appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

into the inverterʼs three-prong AC outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

and operate normally (figure A).

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: The inverter will not operate

 

 

 

 

 

 

 

 

 

 

 

 

 

appliances and equipment that

 

 

 

 

 

 

 

 

 

 

 

 

 

generate heat, such as hair

 

 

 

 

 

 

 

 

 

 

 

 

 

dryers, electric blankets, microwave

 

 

 

 

 

 

 

 

 

 

 

 

 

ovens and toasters.

 

 

 

 

 

 

 

 

 

 

 

 

 

Remember to disconnect the unit from any power source when it is not in use.

Operation of the USB Charging Port - Figure B

1.Connect the unit to a vehicleʼs accessory outlet or other 12 volt DC power source. Make sure there is adequate space for proper ventilation

of the inverter (figure B).

B

2.Rotate the unit slightly to make sure

 

there is good contact.

 

3.The Power/Fault LED Indicator will light green, indicating a proper connection. If

the Power/Fault LED Indicator lights red, a Fault condition exists. Refer to the Troubleshooting Section of this Instruction Manual.

4.If the inverter does not work, make sure

the ignition/accessory outlet is powering the accessory outlet. Some vehicles require the ignition switch to be turned

on.

5.Plug the USB-powered device into the inverterʼs USB Charging Port and oper-

ate normally (figure B). Note:This inverterʼs USB Charging Port does not support data

communication. It only provides 5 volts DC/500 mA power to an

external USB-powered device. Note: Not all mobile phones are provided

with a charging cable, they are

normally data cables which are not supported by this device - please check with your mobile phone manufacturer for the correct charging cable. Remember to disconnect the unit from any power source when it is not in use.

Protective Features

The inverter monitors the following conditions:

Low Battery Voltage — This condition is not harmful to the inverter, but could damage the power source, so the inverter will automatically shut down when input voltage drops below 10.5 ± 0.3 volts DC. Once the voltage recovers the inverter will auto restart.

Input Voltage Too High — The inverter will automatically shut down when DC input voltage exceeds 15.5 ± 0.3 volts, as this can harm the unit. Once the voltage recovers the inverter will auto restart.

Thermal Shutdown Protection — The inverter will automatically shut down when the unit becomes overheated.

Overload/Short Circuit Protection — The inverter will automatically shut down when a short circuit occurs.

Notes: The Power/Fault LED Indicator will light red to indicate a Fault condition before automatic shutdown occurs.

If unit shuts down, disconnect it from the 12 volt DC power source, remove the load, wait a few minutes, then plug it back in, rotating slightly to make sure there is good contact.

Operating Tips

The inverter should only be operated in locations that are:

DRY — Do not allow water or other liquids to come into contact with the inverter.

COOL — Surrounding air temperature should ideally be 10-20°C (50-68°F). Keep the inverter away from direct sunlight, when possible.

WELL-VENTILATED — Keep the area surrounding the inverter clear to ensure free air circulation around the unit. Do not place items on or over the inverter during operation. The unit will shut down if the internal temperature gets too hot. The inverter will auto-reset after it cools down.

SAFE — Do not use the inverter near flammable materials or in any locations that may accumulate flammable fumes or gases. This is an electrical appliance that can briefly spark when electrical connections are made or broken.

CARE AND MAINTENANCE

Storage

1.Ideal storage temperature range is 0-40°C (32-104°F).

2.Store and use the inverter in a cool, dry place with adequate ventilation for all-around air circulation.

3.Avoid locations that are exposed to heating units, radiators, direct sunlight, or excessive humidity or dampness.

Power/Fault LED Indicator

The Power / Fault LED Indicator has 3 states ; Green - normal operation.

Flashing amber - low input voltage, AC output still on.

Red - Fault condition, AC output switched off. See the Protective Features Section of this Instruction Manual and Fault Conditions in the following section.

TROUBLESHOOTING

Common Audio Problems

Problem

Explanation/Recommendation

Buzzing sound in audio

Some inexpensive stereo systems and boom boxes make a buzzing

systems

sound when operated from the inverter, because the power supply in

 

the electronic device does not properly filter the modified sine wave

 

produced by the

 

inverter. The only solution to this problem is to use a sound system

 

that has a higher quality power supply.

Fault Conditions

LED Color

Possible Cause

Recommendation

 

 

 

Flashing

Low input voltage

Start Engine

Amber

 

 

 

 

 

Red

Battery voltage below

Recharge battery or check DC power supply.

 

10.5 volts

 

Red

Equipment being

Reduce load to maximum 100 watts.

 

operated draws too

 

 

much power

 

 

 

 

Red

Inverter in thermal

Allow inverter to cool down. Ensure there is adequate

 

shutdown condition

ventilation around the load is no more than 100 watts for

 

 

continuous operation.

 

 

 

Red

AC output is shorted

Unplug the AC appliance. Disconnect the unit from any 12 volt

 

 

DC power source. Check the appliance cord. Refer to the

 

 

Service Information section that follows to contact a

 

 

Black & Decker Service Center.

 

 

 

SERVICE INFORMATION

All Black & Decker Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the Black & Decker location nearest you. To find your local service location, refer to the yellow page directory under "Tools—Electric" or call:

1-800-544-6986 or visit www.blackanddecker.com

FULL TWO-YEAR HOME USE WARRANTY

Black & Decker (U.S.) Inc. warrants this product for two years against any defects in material or workmanship. The defective product will be replaced or repaired at no charge in either of two ways.

The first, which will result in exchanges only, is to return the product to the retailer from whom it was purchased (provided that the store is a participating retailer). Returns should be made within the time period of the retailerʼs policy for exchanges (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges.

The second option is to take or send the product (prepaid) to a Black & Decker owned or authorized Service Center for repair or replacement at our option. Proof of purchase may be required. Black & Decker owned and authorized Service Centers are listed under "Tools-Electric" in the yellow pages of the phone directory.

This warranty does not apply to accessories. This warranty gives you specific legal rights and you may have other rights which vary from state to state or province to province. Should you have any questions, contact the manager of your nearest Black & Decker Service Center.

This product is not intended for commercial use.

FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call 1-800-544-6986 for a free replacement.

LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, check country specific warranty information contained in the packaging, call the local company or see the website for warranty information.

SPECIFICATIONS

Output Power:

100 watts continuous

DC Input:

13.8 volts DC, 8 amps

AC Output:

100 watt continuous output – 115V AC @13.8V DC, 60 Hz

USB Charging Port Output:

5 volts DC/500 mA

Fuse:

10 amp internal fuse

Output Waveform:

Modified Sine Wave

Optimum Efficiency:

>85%

Low Voltage Shutdown:

<10.5 ± 0.3 volts input voltage

Operating Temperature:

10-20°C (50-68°F)

Storage Temperature:

0-40°C (32-104°F)

Operating/Relative Humidity:

5-95% non-condensing

Imported by

See ‘Tools-

Black & Decker (U.S.) Inc.,

Electric’

701 E. Joppa Rd.

– Yellow Pages –

Towson, MD 21286 U.S.A.

for Service &

 

Sales

CONVERSOR ELÉCTRICO DE 100 VATIOS

CON PUERTO DE CARGA USB

MANUAL DE INSTRUCCIONES

Gracias por elegir Black & Decker! Visite www.BlackandDecker.com/NewOwner

para registrar su nuevo producto.

LEA EL MANUAL ANTES DE DEVOLVER ESTE PRODUCTO POR CUALQUIER MOTIVO:

Si tiene una consulta o algún inconveniente con su producto Black & Decker, visite

HTTP://WWW.BLACKANDDECKER.COM/INSTANTANSWERS para obtener respuestas instantáneas las 24 horas del día.

Si no encuentra la respuesta o no tiene acceso a Internet, llame al 1-800-544-6986 de lunes a viernes de 8 a.m. a 5 p.m. hora del Este para hablar con un agente.

Cuando llame, tenga a mano el número de catálogo.

CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS.

NORMAS DE SEGURIDAD: DEFINICIONES

PELIGRO: Indica una situación de peligro inminente que, si no se evita, provocará la muerte o lesiones graves.

ADVERTENCIA: Indica una situación de peligro potencial que, si no se evita, podría provocar la muerte o lesiones graves.

PRECAUCIÓN: Indica una situación de peligro potencial que, si no se evita, provocará lesiones leves o moderadas.

PRECAUCIÓN: Cuando se utiliza sin el símbolo de alerta de seguridad indica una situación de peligro potencial que, si no se evita, puede provocar daños a la propiedad.

RIESGO DE OPERACIÓN INSEGURA. Cuando se utilizan herramientas o equipos, siempre se deben respetar las precauciones de seguridad para reducir el riesgo de lesiones personales. La operación, el mantenimiento o la modificación incorrectos de herramientas o equipos pueden provocar lesiones graves y daños a la propiedad. Las herramientas y los equipos están diseñados para determinados usos. Black & Decker recomienda enfáticamente que NO se modifique este producto y que NO se utilice para ningún otro uso que aquél para el que fue diseñado. Lea y comprenda todas las instrucciones operativas y las advertencias antes de utilizar cualquier herramienta o equipo.

INSTRUCCIONES IMPORTANTES

SOBRE SEGURIDAD

ADVERTENCIAS E INSTRUCCIONES DE SEGURIDAD GENERALES PARA TODAS LAS HERRAMIENTAS

LEA TODAS LAS INSTRUCCIONES

ADVERTENCIA: Lea todas las instrucciones antes de operar el producto. El incumplimiento de todas las instrucciones enumeradas a continuación puede provocar una descarga eléctrica, un incendio o lesiones graves.

EVITE LAS CONDICIONES AMBIENTALES PELIGROSAS. NO utilice artefactos en zonas húmedas o mojadas. No utilice artefactos bajo la lluvia.

GUARDE LOS ARTEFACTOS QUE NO UTILICE EN EL INTERIOR. Cuando no los utilice, los artefactos deben guardarse en el interior en un lugar seco, alto o bajo llave, lejos del alcance de los niños.

NO FUERCE EL APARATO. Trabajará mejor y con menos probabilidad de riesgo de daños si se opera a la velocidad para la que fue diseñado.

UTILICE EL APARATO ADECUADO. Nunca utilice el aparato para otra tarea que no sea aquella para la que fue creada.

DESCONECTE LOS APARATOS. Desconecte el aparato de la fuente de energía cuando no lo utiliza, antes de realizar un mantenimiento y al cambiar accesorios como hojas y elementos semejantes.

EL ENFRIAMIENTO CORRECTO ES FUNDAMENTAL AL OPERAR EL CONVERSOR. No coloque la unidad cerca de los orificios de ventilación del vehículo ni la exponga a la luz solar directa.

USO DE SUPLEMENTOS Y ACCESORIOS. El uso de accesorios o dispositivos no recomendados para este aparato puede resultar peligroso. Nota: Consulte la sección "Accesorios" de este manual para obtener detalles adicionales.

VERIFIQUE QUE NO HAYA PIEZAS DAÑADAS. Una pieza se daña que se debe reparar o substituir correctamente por un centro de servicio autorizado.

EN ESPACIOS ABIERTOS, USE CABLES PROLONGADORES. Cuando una aplicación tapada en esta unidad se utiliza al aire libre, utilice solamente las cuerdas de la extensión previstas para el uso al aire libre y así que marcado. OBSERVE QUE ESTE INVERSOR NO ESTÁ PENSADO PARA SER UTILIZADO AL AIRE LIBRE.

CABLES PROLONGADORES. Asegúrese de que el cable prolongador esté en buenas condiciones. Cuando utilice un cable prolongador, cerciórese de que tenga la capacidad para conducir la corriente que su producto exige. Un cable de menor capacidad provocará una disminución en el voltaje de la línea, lo cual producirá una pérdida de potencia y sobrecalentamiento. La siguiente tabla muestra la medida correcta que debe utilizar según la longitud del cable y la capacidad nominal en amperios indicada en la placa. En caso de duda, utilice el calibre inmediatamente superior. Cuanto menor es el número de calibre, más grueso es el cable.

Calibre mínimo para los juegos de cables

Voltios

 

 

Longitud total del cable en pies

120V

 

0-25

26-50

51-100

101-150

 

 

 

(0-7,6m)

(7,6-15,2m)

(15,2-30,4m)

(30,4-45,7m)

240V

 

0-50

51-100

101-200

201-300

 

 

 

(0-15,2m)

(15,2-30,4m)

(30,4-60,9m)

(60,9-91,4m)

Capacidad nominal en amperios

 

 

Más

No más

Medida de conductor estadounidense

 

que

que

 

 

 

 

0

-

6

18

16

16

14

6

-

10

18

16

14

12

10 -

12

16

16

14

12

12 -

16

14

12

No recomendado

ADVER-

TENCIA: PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA:

No conecte al cableado de distribución de CA.

No realice conexiones o desconexiones eléctricas en áreas designadas como PROTEGIDAS CONTRA IGNICIÓN. Esto incluye el adaptador para aviones o el enchufe tipo encendedor de cigarrillos de CC. Esta unidad NO está aprobada para áreas protegidas contra ignición.

NUNCA sumerja la unidad en el agua ni en ningún otro líquido, ni la utilice cuando esté húmeda.

No introduzca objetos extraños en el tomacorriente de CA ni en el puerto USB.

ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO:

No opere cerca de materiales, vapores o gases inflamables.

NO lo exponga al calor extremo o a las llamas.

PRECAUCIÓN: PARA REDUCIR EL RIESGO DE LESIONES O DAÑO A LA PROPIEDAD:

Quite el enchufe de la aplicación del enchufe antes de trabajar en la aplicación.

NO intente conectar o configurar la unidad o sus componentes mientras maneja su vehículo. El hecho de no prestar atención a la carretera puede tener como consecuencia un accidente grave.

Siempre utilice el conversor en lugares adecuadamente ventilados. No bloquee las ranuras de ventilación.

SIEMPRE APAGUE el conversor desenchufándolo del tomacorriente para accesorios de CC cuando no lo utilice.

Asegúrese de que el voltaje nominal de encendido sea CC de 12 voltios, conexión central positivo (+).

Al utilizar esta unidad en un vehículo, revise el manual del usuario del vehículo para ver el máximo rango de potencia y la salida recomendada. No lo instale en el compartimiento del motor. Instálelo en un área bien ventilada.

No lo utilice con sistemas eléctricos con positivo a tierra*. La conexión de polaridad inversa hará que un fusible se queme y puede causar un daño permanente al conversor y anulará la garantía.

*La mayoría de los automóviles, vehículos recreativos y camiones modernos posee un negativo a tierra.

Tenga en cuenta que este conversor no funcionará con aparatos o equipos de alta potencia en vatios que produzcan calor, como secadores de cabello, hornos de microondas y tostadores.

No abra el conversor: no hay piezas que el usuario pueda reparar en su interior.

No utilice este conversor con dispositivos médicos. No se ha comprobado su funcionamiento en aplicaciones médicas.

Mantenga fuera del alcance de los niños. ¡Esto no es un juguete!

Instale y opere la unidad solamente como se describe en este manual de instrucciones.

No utilice este inversor en un watercraft. No se califica para los usos marinas.

Controle el desgaste de la unidad periódicamente. Lleve la unidad a un técnico calificado para reemplazar las piezas desgastadas o defectuosas de inmediato.

Lea Y Entienda Este Manual De Instrucción Antes De Usar Esta Unidad.

CONSERVE ESTAS INSTRUCCIONES

ADVERTENCIA: PARA REDUCIR EL RIESGO DE LESIONES:

Siga estas instrucciones y las publicadas por el fabricante de la batería y de cualquier equipo que tenga la intención de utilizar con esta unidad. Revise las indicaciones sobre precauciones en estos productos y en el motor.

INTRODUCCIÓN

Gracias por comprar el conversor eléctrico PI100BB con puerto de carga USB. Este conversor puede utilizarse para operar productos electrónicos personales, como: computadoras portátiles, cámaras digitales o filmadoras, reproductores de MP3, teléfonos celulares, agendas electrónicas y más. También puede utilizarse para recargar dispositivos de CA de 110/120 voltios que tengan un adaptador de recarga apropiado con un enchufe de dos o tres patas estadounidense estándar.

Lea este Manual de instrucciones detenidamente antes de utilizar la unidad para garantizar su óptimo rendimiento y evitar dañar el producto.

PRODUCTOS INCOMPATIBLES:

PRECAUCIÓN:

Ciertos productos contienen fuentes de energía o circuitos que no son compatibles con los conversores que utilizan una salida de onda senoidal modificada (como este conversor) y que pueden dañarse al utilizar este conversor.

Si su producto requiere una alimentación de entrada de CA de onda senoidal pura para funcionar correctamente, es posible que lo indique el manual de instrucciones de su producto. En caso de duda, debe comunicarse con el fabricante de su producto ANTES DE UTILIZARLO.

Algunos productos deben alimentarse con una fuente de energía de onda senoidal pura, como la energía estándar de uso doméstico o un conversor de “onda senoidal pura” para poder funcionar correctamente.

Este conversor puede dañar su producto si éste contiene:

1.Fuentes de energía tipo transformador

2.Fuentes de energía controladas por microprocesador

3.Fuentes de energía con acoplamiento capacitivo

Si se utiliza un producto incompatible con este conversor:

Es posible que el producto no funcione en absoluto, sin indicios de falla. Es posible que el fusible del producto se haya abierto al intentar utilizarlo con el conversor.

El producto presenta un funcionamiento anormal (como operación intermitente, zumbido y similares).

ADVERTENCIA: Si el producto no funciona normalmente, para reducir el riesgo de lesiones y daños a la propiedad:

• Apague el producto de inmediato y desenchúfelo del conversor.

CARACTERÍSTICAS

Salida continua de 100 vatios*

Puerto de carga USB de CC de 5 voltios

El conversor más fácil de utilizar: de verdad lo enchufa y funciona

Luz indicadora LED tricolor de energía/falla

Compacto, eficiente y silencioso

Protección del circuito electrónico que evita daños por sobrecarga/ventilación insuficiente (sobrecalentamiento)

Apagado por batería baja

*Consulte la sección “Especificaciones”

Controles y funciones

TOMACORRIENTE DE CA DE 115

ENCHUFE PARA ADAPTADOR DE

VEHÍCULO DE 12 VOLTIOS DE CC

VOLTIOS DE TRES CLAVIJAS

 

INDICADOR LED DE

 

POTENCIA Y FALLAS

EL ENCHUFE SE AJUSTA A

INTEGRADO

90°

INDICADOR LED DE

POTENCIA Y FALLAS

INTEGRADO

FUNCIONAMIENTO DEL CONVERSOR

El conversor es un dispositivo electrónico que convierte electricidad de CC (corriente continua) de bajo voltaje de una batería a energía para uso doméstico de CA (corriente alterna) de 115 voltios. Durante el diseño de este conversor, Black & Decker incorporó técnicas de diseño utilizadas anteriormente en fuentes de energía para computadoras. El resultado de estas innovaciones en el diseño es un conversor eléctrico más pequeño, más liviano y más fácil de utilizar.

El conversor eléctrico convierte energía en dos etapas. La primera etapa consiste en un proceso de conversión de CC a CC que incrementa la CC de bajo voltaje en la entrada del conversor a CC de 145 voltios. La segunda etapa es una etapa puente MOSFET (transistor de efecto de campo semiconductor de óxido metálico) que convierte la CC de alto voltaje a CA de 115 voltios, 60 Hz.

La etapa de conversión de CC a CC comprende técnicas de conversión por conmutación de energía creativas, de alta frecuencia y cero voltaje, que reemplazan los grandes transformadores incluidos en los modelos con tecnología menos avanzada. La etapa de conversión utiliza transistores eléctricos MOSFET avanzados en una configuración de puente completa.

La forma de onda de salida del conversor eléctrico

AVISO: LA SALIDA DE ESTE DISPOSITIVO NO ES SINUSOIDAL. TIENE UNA DISTORSIÓN ARMÓNICA TOTAL DE 38% Y UN ARMÓNICO ÚNICO MÁXIMO DE 32% A 25% DE LA CARGA NOMINAL.

La forma de onda de la salida de CA de este conversor se conoce como una onda senoidal modificada. Es una forma de onda escalonada que posee características similares a la forma de onda senoidal de la electricidad. Este tipo de forma de onda es adecuado para la mayoría de las cargas de CA, incluidas las fuentes de energía por conmutación y lineales utilizadas en equipos electrónicos, transformadores y motores pequeños.La onda senoidal modificada producida por este conversor posee un voltaje RMS (raíz cuadrada media) de 115 voltios. La mayoría de los voltímetros de CA (digitales y análogos) son sensibles al valor promedio de la forma de onda en lugar de al valor RMS. Están calibrados para el voltaje RMS suponiendo que la forma de onda medida será una onda senoidal pura. Estos medidores no leerán correctamente el voltaje RMS de una onda senoidal modificada. Un medidor RMS no VERDADERO leerá aproximadamente 20 a 30 voltios mínimo cuando mida la salida de este conversor. Para realizar una medición adecuada del voltaje de salida de esta unidad, utilice un voltímetro de lectura RMS VERDADERO como un Fluke 87, Fluke 8060A, Beckman 4410 o Triplett 4200.

Salida de CA de 115 voltios

Loading...
+ 4 hidden pages