2
Switches:
Button for each monitor port,
Button for each network port,
CONFIG1 DIP switches,
CONFIG2 DIP switches
Relays: Type: Sealed, latching with
gold-clad silver contact
material;
Initial contact resistance:
50 milliohms;
Expected life: 10,000,000
operations
COMM IN Pins:
2 (Master/Slave In),
3 (Signal Ground),
4 (Receive Data Out),
5 (Transmit Data In)
COMM OUT Pins:
2 (Master/Slave Out),
3 (Signal Ground),
4 (Receive Data In),
5 (Transmit Data Out)
Network Control: ASCII character
strings and VT100™ terminal
menus; asynchronous; RS-232;
2400, 4800, 9600, or 19200 baud;
No parity, 8 data bits, 1 stop bit,
full duplex
Switched Leads: TS760A, TS761A:
All 8 leads;
TS766A: All 15 leads
Network General’s Sniffer Server:
Asynchronous; RS-232; 2400
baud; no parity, 8 data bits, 1 stop
bit, full duplex
System Capacity: ASCII character
strings and VT100 terminal
menus: (64) daisychained units
with (8) networks per unit;
Network General’s Sniffer
Server: (1) unit, with (8) or
(16) networks
Connectors: TS760A: (8) RJ-45;
TS761A: (16) RJ-45;
TS766A: (16) DB15
TIndicators: LEDs: ON, MON1 for
each network port, MON2 for
each network port
emperature Tolerance:
32 to 104°F (0 to 40°C)
Humidity Tolerance: Up to 95%
noncondensing
Power: 100–250 VAC, 50/60/440 Hz
and 120–300 VDC 1 A,
automatically selected
Size: TS760A: 1.75"H x 19"W x 11.4"D
(4.4 x 48.3 x 29 cm);
TS761A, TS766A: 3.5"H x 19"W x
11.4"D (8.9 x 48.3 x 29 cm)
Specifications
Ordering Information
ITEM CODE
Monitor Access Unit
8-Network, RJ-45.....................................................TS760A
16-Network, RJ-45...................................................TS761A
16-Network, DB15....................................................TS766A
T
o connect two Sniffer Servers, you’ll need a…
Y Cable, DB9/DB9/RJ-11 ............................................EHT110
Connect a Sniffer Server to
any of 8 or 16 networks with
the Monitor Access Unit.