Black Box SW547A, SW548A Specifications

1
Black Box Corporation • 1000 Park Drive • Lawrence, PA 15055-1018 • Tech Support: 724-746-5500 • www.blackbox.com e-mail: info@blackbox.com
© 2005. All rights reserved.
Black Box Corporation.
02/07/2002 #26042
Telnet console manager.
For local or remote serial-port switching.
Eight or sixteen RS-232 serial ports and one Ethernet port.
Up to 115-kbps throughput.
Port-specific password protection.
Menu-driven control. No software required.
User-definable modem auto-setup command strings.
Any-to-any port switching.
Rackmount ears included.
T
hese versatile switches provide
secure, in-band and/or out-of­band access to RS-232/V.24 console ports as well as maintenance ports on UNIX
®
servers, routers, and other networking equipment.
You can use the BLACK BOX
®
Remote Console Port Manager for:
• local or remote console port switching,
• UNIX serial console management,
• Telnet or dial-up access to consoles at your remote sites, or
• sharing multiple console ports through a single VT100™ terminal or PC.
The amount of control on the switch is impressive. You can access remote devices in order to change configuration parameters, connect users to restricted ports, collect buffered data, and perform a variety of other administrative functions.
Each port on the switch can be individually accessed by number, name, or group without having to navigate a complex procedure in
Access serial console ports for convenient
in- or out-of-band management.
Key Features
REMOTE CONSOLE PORT MANAGERS
the process. You can individually configure ports using simple, menu-driven commands, whether you want to set passwords, data rates, parity, flow control, or other operating parameters.
You can connect up to 8 or 16 different devices to the Remote Console Port Manager. And this can be done without having to select a common baud rate, handshaking, or parity for the connected devices. The Remote Console Port Manager converts the devices’ data rates and other parameters. Each port can be individually configured for various options, and the switch will still provide communication between the dissimilar devices.
Want to limit access to important commands? The switch is designed to do just that, making it ideal for co-location applications. It has two security levels that allow each port to function as a Supervisor Port or a User Port, depending on the password entered during login. Users on Supervisor Ports can change configuration and display status,
and connect to any other port. User Port users, however, are only allowed to connect to the ports provided by their password.
Each individual port can be assigned its own unique, user­defined password, up to 16 characters long. With its non­volatile memory, the switch retains information relating to port connections even if the unit loses power or is interrupted.
The full matrix capability of the Remote Console Port Manager enables you to connect any port to any other port on the device. Ports can also be connected or disconnected by a third party with supervisor rights. For example, systems managers can swap various RS-232 devices between ports on a terminal server at a remote location. Configuration and Status screens within the menu display port parameters and connection activity for one or all ports.
When you want individual ports to capture and store incoming data, you can set the
(continued on page 2)
2
Sample Application Using 16-Port Model
PSTN
Remote User
or Supervisor
Modem
Service Tech
Remote User
or Supervisor
WAN
(Telnet)
Port Password: COLOCATION2
Port Password: COLOCATION1
(continued from page 1)
(continued on page 3)
switch to operate in Buffer Mode. This “snapshot” of the last 32K of received data is stored in non­volatile memory and can be viewed, saved, or erased at any time. This feature is particularly useful when alarm information, or other critical data, is sent to a specific port during non-connect periods.
You’re also provided with several control options. The Remote Console Port Manger can be controlled by a local PC (communicating with the switch via cable) or controlled remotely via an external modem or Telnet connection. Just use a terminal emulation or Telnet program to send commands for connecting ports or displaying status.
Once you configure the Remote Console Port Manager for your application, you can save your parameters and options to
an ASCII text file on your PC. Doing this enables you to quickly restore user-selected parameters if the unit configuration is accidentally altered or deleted. You can even upload saved parameters to other Remote Console Port Manager units—a useful function when you want to quickly set up several units that are configured with identical or similar parameters.
Ports and switches.
There are two types of ports on the back panel: a Network Port and eight or sixteen RS-232 Ports.
The Network Port is an RJ-45 Ethernet port (a 10BASE-T interface) for connection to your TCP/IP network. To communicate via a network, you need only to specify an IP address, subnet mask, and gateway address.
Standard DB9 connectors configured as DTE ports, the RS-232 Ports are used for connecting to console ports on
This is just one of many possible installation configurations for the Remote Console Port Manager. In this example, ports have been configured as follows:
Network Port: This port enables Telnet access by remote supervisors and/or users. When a Telnet connection is established, the switch prompts the caller to enter a password. If the supervisor password is entered, the unit recognizes supervisor-level commands; if a port password is entered, it only recognizes user-level commands. Supervisors are allowed to adjust port configuration, connect to any port, or review unit status. Users, however, are only permitted to review status and connect to ports that are allowed by their port password.
Port 1 (System Set-Up Port): In this application, this port has been left open so on-site service personnel can access the switch’s Command Mode without disrupting other ports. Because Port 1 is the System Set-Up Port, the service tech is allowed password-protected access to supervisor-level commands, and is able to connect to any port, change configuration, or display unit status.
Port 2 (Modem Port): An external modem has been installed here, and the port has been configured for Modem Mode. This mode allows definition of a modem reset string, initialization string, and hang-up string. When a caller contacts the Remote Console Port Manager via a modem, a password prompt is displayed. If the supervisor password is entered, the switch permits access to supervisor-
Compliance: FCC Subpart B, Part 15,
Class A; UL
®
; CSA; TUV; CE
Communications Chip: 16654 UART
with FIFO and flow control
Connectors:
Both (1) RJ-45 10BASE-T; 8-port: (8) DB9 M (DTE); 16-port: (16) DB9 M (DTE)
Data Format: ASCII
Flow Control: RTS/CTS, X-ON/X-OFF,
or both
Indicators: Front-panel LEDs: (1) ON
(power), (1) RDY (ready), (1) NET (network connection); (8) or (16) ACTIVITY numbered (data activity per corresponding port)
Interface: RS-232, Ethernet
Leads Supported: 1–5, 7, 8
Memory: Stores parameters and
captured data; non-volatile 512K SRAM buffer memory; statically allocated
Modem Control: User-defined
password, initialization, and hangup strings
Passwords: Individual, assigned to
each port
Processor: Motorola
®
68EC000,
16 bit, 12 MHz
Protocol: Asynchronous
Speed: 300 bps to 115.2 kbps
(all standard rates)
Switching Commands: Menu text
via terminal
Operating Temperature Tolerance:
32 to 113ºF (0 to 45ºC)
Humidity Tolerance: 10 to 90%,
noncondensing
Power: 115/230 VAC, 50/60 Hz,
5 watts
Size: 1.75"H x 17"W x 6.5"D
(4.5 x 43.2 x 16.5 cm)
Weight: 6 lb. (2.7 kg)
Specifications
level commands; if a port password is entered, the unit only recognizes user­level commands. As noted earlier, supervisors are allowed to adjust port configuration, connect to any port, or review unit status, but users are only allowed to review status and connect to the ports allowed by their port password.
Ports 5, 7, and 9 (User Ports): The port password COLOCATION1 has been assigned to these three ports. If the Remote Console Port Manager is contacted via the Network Port or Modem Port, and this password is entered at login, users are only able to review status and connect to the devices that are attached to Ports 5, 7, and 9.
Ports 12, 14, and 16 (User Ports): The port password COLOCATION2 has been assigned to these three ports. If the switch is contacted via the Network Port or Modem Port, and this password is entered at login, users are only able to review status and connect to the devices that are attached to Ports 12, 14, and 16.
NOTE: In this example, Ports 3 through 16 could also be a mixture of ports connected to external modems and ports connected to devices such as file servers or archives. This set-up would enable remote users to dial in and access a specific file server or archive as long as they enter a valid port password at login.
Loading...