Black Box PS730A-M, PS732A, PS731A, PS731A-M, PS732A-M User Manual

...
© Copyright 2006. Black Box Corporation. All rights reserved.
1000 Park Drive · Lawrence, PA 15055-1018 · 724-746-5500 ·
Fax 724-746-0746
ServPower Omni
OCTOBER 2007
PS730A PS730A-M PS731A PS731A-M PS732A PS732A-M PS733A PS733A-M PSE711 PSE712 PSE713 PSE714 PSE721 PSE722 PSE723 PSE724
Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com
CUSTOMER
SUPPORT
INFORMATION
37
ServPower Omni
36
Philippines 181 Portugal 253 Slovak Republic 253 Spain 253 Sweden 253 Switzerland 253 Taiwan 254 United Kingdom 253 United States 181
FCC STATEMENT
1
FEDERAL COMMUNICATIONS COMMISSION
AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
ServPower Omni
2
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
Appendix B: Modem Certifications
35
Modem Certifications
The following countries have certified the internal modem. In order to comply with local regulations, the countrycode must be set to the country of installation. To set the modem for the desired country use the CLI command
set modem countrycode <countrycode>. Use the
get modem command to display the current country setting.
Note: Use of the wrong countrycode violates local laws and the warranty of this product.
Country countrycode
Argentina 07 Australia 09 Austria 253 Belgium 253 Canada 181 China 181 Cyprus 253 Czech Republic 253 Denmark 253 Finland 253 France 253 Germany 253 Greece 253 Hong Kong 153 Hungary 253 Iceland 253 Indonesia 153 Ireland 253 Italy 253 Japan 00 Korea 181 Liechtenstein 253 Luxembourg 253 Mexico 181 Netherlands 253 New Zealand 126 Norway 253
ServPower Omni
34
PSE723 2 x C20 8 x C13 I, S
PSE724 2 x C20 8 x C13 I, S, M
Key:
INPUT:
N15 NEMA 5-15 Linecord 115VAC 15 Amps combined total
switched
N20 NEMA 5-20 Linecord 115VAC 20 Amps combined total
switched
C14 IEC320 C14 Receptacle 100-240VAC 10 Amps total at 240VAC
Max
C20 IEC320 C20 Receptacle 100-240VAC 20 Amps total at 240VAC
Max
O
UTLET:
N15 NEMA 5-15 Receptacle 115VAC 12 Amps Max C13 IEC 320 C13 Receptacle 100-240VAC 10 Amps Max
C
ONTROL:
I 10/100 Ethernet. Web, Telnet, SNMP. Port Assignable for Web
and Telnet. SSL on Web control. S Serial Port. 115,200 bps. Command Line Interface M Internal Modem. V.92 and below. Approved in 50 Countries
Supports data and DTMF tone control (with voice response)
NOM STATEMENT
3
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato;
o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en
su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
ServPower Omni
4
Appendix A: Specifications
33
Specifications
Physical:
Height: 1U 1.75 in (4.5 cm)
Width: 19.0 in (48.25 cm)
Depth: 6.00 in (15.25 cm)
Weight: 7 lbs (3.25 Kg)
Input Required Model Input Output Control
PS730A N15 8 x N15 I, S,
PS730A-M N15 8 x N15 I, S, M
PS731A 2 x N15 8 x N15 I, S, L
PS731A-M 2 x N15 8 x N15 I, S, M
PS732A N20 8 x N15 I, S
PS732A-M N20 8 x N15 I, S, M
PS733A 2 x N20 8 x N15 I, S
PS733A-M 2 x N20 8 x N15 I, S, M
PSE711 C14 8 x C13 I, S
PSE712 C14 8 x C13 I, S, M
PSE721 2 x C14 8 x C13 I, S
PSE722 2 x C14 8 x C13 I, S, M
PSE713 C20 8 x C13 I, S
PSE714 C20 8 x C13 I, S, M
Temperature
Operating: 0 to 40
o
C
Storage: -10 to 85
o
C
Relative Humidity
0 to 95%
Non-Condensing