Black Box MT612A-ST, MT651A-ST-R2, MT650A-ST-R3, MT653A-ST-D48-R3, MT619A-ST-R2 Specifications

...
Is your access point for digital service
painfully far from where you need it to be?
Not a problem.
Is your access point for digital service
painfully far from where you need it to be?
Not a problem.
Fiber Optic Line Drivers
© 2007. All rights reserved. Black Box Corporation.
FREE 24-hour Tech Support: 724-746-5500
blackbox.com
2 of 4
FEATURES
• Drive data at full T1, E1, T3, or E3 speed over fiber.
• Maximum distances up to 4.3 miles (6.9 km) over multimode or up to 31 miles (49.9 km) over single mode!
• Optical link is immune to EMI/RFI, surges, etc.
• Most standalone models have autosensing power supplies.
• Card versions available.
• Perform local and remote loopback and dry-contact alarms.
If you need to move data
at T1 or E1 speeds, but you
don’t want to (or can’t)
use a T1/E1 line to do it,
a pair of line drivers and
a spool of fiber cable will—
with no worries about
data-line tapping, surges,
or interference.
OVERVIEW
Would you like to put your high-speed computer or other DTE device in a different room from your T1, E1, T3, or E3 CSU/DSU? In a different building? A different campus? Or would you just like to make a connection at T1, E1, T3, or E3 speeds without handing your entire budget to a telco for a subscription to digital service?
Pairs of our Fiber Optic Line Drivers can pass data to each other at full speed across multimode or single-mode fiber optic cables. Not only does this solve device-placement problems, it does so with optical links that aren’t susceptible to tapping, noise, and other hazards of electrical communication.
Models with MT650 and MT653 product code prefixes transmit and receive data on the 1310-nm wavelength into as much as 31 miles (49.9 km) of single-mode cable. MT651 models transmit and receive at 850 nm into as much as 4.3 miles (6.9 km) of multimode cable. MT612A-ST models transmit and receive at 820-nm into as much as 3.1 miles (5 km) of multimode cable. All Fiber Optic Line Drivers have common ST
®
connectors.
The various models in standalone enclosures can take advantage of different types of site power. The MT650A-ST-R3 has an autosensing power supply and the MT620AE-R2 plugs into European standard outlets that provide 230 VAC. The MT653A-ST-D48-R3 can be attached to site power systems that provide -48 VDC (a separate DC power plug is provided for terminating a power cord).
MT650C-R2 and MT651C are card versions that can be installed in our versatile RackNest 2/14 products. Each RackNest
can hold up to 14 cards. We offer a wide variety of line-driver and short-haul modem cards for the RackNest. For more information, please refer to Product Data Sheet 19273.
You can set a T1 or E1 line driver to use a 100-ohm balanced T1 interface, a 120-ohm balanced E1 interface, or a 75-ohm unbalanced E1 interface. On the standalone models, the balanced interfaces are expressed on a DB15 connector, while the unbalanced interface is on a pair of BNCs. On the card models, the balanced interfaces are expressed on the RackNest’s 5-position terminal blocks, and you’ll need a special adapter (call us) for the unbalanced interface.
All T1 or E1 line drivers feature dry-contact alarm circuitry that can alert you to problems on the T1/E1 link. The alarms are expressed on the same DB15 connector on the standalone models; they’re on the RackNest’s DB25 connectors for the card models. (Refer to page 4 for a discussion of T1/E1 leads and dry-contact pinning.) Even if you don’t use the alarms, the line drivers have a full set of LEDs—and user-controlled local and remote loopback capability—for quickly diagnosing problems.
Our MT618A-ST-R3 and MT619A-ST-R2 line drivers convert T3’s super-fast 44.736-Mbps signals to fiber optic light pulses. The multimode unit, MT619A-ST-R2 has a range of 1.5 miles (2.4 km)— and many of the single-mode units have a range of 31 miles (49.9 km)!
PABX
2/26/2007 #11835
724-746-5500 blackbox.com
T1/E1 Fiber Optic Line Driver
(MT651A-ST-R2,MT650A-ST-R3,
or MT653A-ST-D48-R3)
T1/E1 Fiber Optic Line Driver
(MT651A-ST-R2,MT650A-ST-R3,
or MT653A-ST-D48-R3)
T1/E1 Fiber Optic Line Driver
(MT651A-ST-R2,MT650A-ST-R3,
or MT653A-ST-D48-R3)
T1/E1 Fiber Optic Line Driver
(MT651A-ST-R2,MT650A-ST-R3,
or MT653A-ST-D48-R3)
T1/E1 muxT1/E1 mux
Fiber optic cableTwisted pair or coax
T1 or E1
Twisted pair or coax
T1 or E1
Fiber optic cable
Twisted pair or coax
T1 or E1
Twisted pair or coax
T1 or E1
Digital Access Cross Connect
(DACS)
3 of 4
2/26/2007 #11835
724-746-5500 blackbox.com
TECH SPECS
Budget (Maximum) —
MT612A-ST, MT651A-ST-R2, MT619A-ST-R2, MT651C:
20 dB over 62.5/125-µm multimode fiber cable;
MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3, MT620AE-R2,
MT650C-R2: 22 dB over 9/125-µm single-mode fiber cable
Compliance —
EMI/RFI: CE; FCC Part 15 Subpart B Class A, IC Class/classe A; Safety: EN 60950, EN 41003
Data Rate (Maximum) —
T1: 1.544 Mbps; E1: 2.048 Mbps
Diagnostic — Dry-contact closure alarm on various DB15 pins
(standalone models) or RackNest DB25 pins (card models) for signal or power loss; minimum switching current 1 A
Distance (Maximum) —
MT612A-ST, MT618A-ST-R3: 3.1 mi. (5 km); MT651A-ST-R2, MT651C: 4.3 mi. (6.9 km); MT650A-ST-R3, MT653A-ST-D48-R3, MT620AE-R2, MT650C-R2:
31 mi. (49.9 km);
MT619A-ST-R2: 1.5 mi. (2.4 km)
Dynamic Range — 28 dB Output Power —
Single-mode: -12 dBm; Multimode: -18 dBm
Overvoltage Protection —
AC/DC overvoltage circuits are connected through transformers to transmit and receive lines
Receiver Sensitivity —
For a BER of 10-9:
MT612A-ST, MT651A-ST-R2, MT619A-ST-R2, MT651C: -38 dBm; MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3, MT620AE-R2,
MT650C-R2: -40 dBm
User Controls — MT612A-ST: Internal: (1) 4-position DIP switch,
(6) 2-position jumpers, (1) 5-position jumper; All other models: (1) front-mounted slide switch for test mode; All others mounted on main board (internal):
(1) jumper block for interface type;
(1) jumper and (3) DIP switches for grounding control
and signal loss handling
Video Standards — VGA, SVGA, XGA, XGA-2 Zero Suppression — B8ZS when set to T1, HDB3 when set to E1 Interface —
Electronic: Either 100-ohm balanced T1, 120-ohm balanced E1,
or 75-ohm unbalanced E1, user-selectable; with card models,
unbalanced E1 requires special adapter— call Technical Support; Optical: MT612A-ST: 820-nm multimode;
MT651A-ST-R2, MT619A-ST-R2, MT651C: 850-nm multimode;
MT650A-ST-R3, MT653A-ST-D48-R3, MT618A-ST-R3,
MT620AE-R2, MT650C-R2: 1300-nm single-mode
Connectors —
Standalone models (all rear-mounted):
For fiber optic link: (2) ST F; For balanced T1 or E1 I/O and for dry-contact alarm: (1) DB15 F; For unbalanced E1 I/O: (2) BNC F; For power:
MT653A-ST-D48-R3: (1) standard 3-pin F; All other models: (1) IEC 320 M inlet;
Card models:
For fiber optic link:
(2) front-mounted ST F; Rear-mounted card-edge F linked to
connectors on rear of RackNest 2/14; For balanced T1/E1: (1) 5-position terminal block; For unbalanced E1: Special plug-in adapter required—
call Technical Support; For dry-contact alarms: (1) DB25 F
Indicators — MT612A-ST: (2) LEDs: (1) Power, (1) Link;
All other models: (6) or (7) front-mounted LEDs: Power, local
loopback, remote loopback, and various error conditions
Temperature Tolerance — 32 to 122°F (0 to 50°C) Humidity Tolerance — Up to 90% noncondensing Power —
MT612A-ST, MT651A-ST-R2, MT650A-ST-R3: 100–240 VAC, 50/60 Hz,
autosensing from AC source through included detachable input cord;
MT653A-ST-D48-R3: -48–60 VDC, autosensing at 130 mA, nominal,
from -48-VDC source through detachable cord (included);
MT619A-ST-R2, MT618A-ST-R3: 108– 132 VAC/207– 253 VAC,
47– 63 Hz, autosensing, from AC source through included detachable input cord;
MT620AE-R2: 230 VAC, 50 Hz; MT651C, MT650C-R2: From the RackNest 2/14 in which
they’re installed;
Consumption for all models: 6 W maximum
Size — MT651A-ST-R2, MT650A-ST-R3, MT653A-ST-D48-R3:
1.7"H x 9.4"W x 6.7"D (4.4 x 23.9 x 17 cm);
All other standalone models: 1.75"H (1U) x 7.6"W x 9.6"D
(4.4 x 19.3 x 24.4 cm);
Card models: 6.2"H x 0.9"W x 9"D (15.7 x 2.3 x 22.9 cm)
Weight — Standalone models: 2.4 lb. (1.1 kg);
Card models: 0.8 lb. (0.4 kg)
4 of 4
2/26/2007 #11835
724-746-5500 blackbox.com
AC-powered standalone models include a manual and
a detachable power cord; card models include a manual.
The DC-powered MT653A-ST-D48-R3 includes a manual
and a DC power-supply connector kit. You have to assemble this connector and use it to terminate the DC power cord that will plug into the Fiber Optic Line Driver.
WHAT‘S INCLUDED
Item Code
T1 Fiber Optic Line Driver ST, Standalone
820-nm Multimode
MT612A-ST
T1/E1 Fiber Optic Line Driver ST, Standalone
850-nm Multimode
MT651A-ST-R2
1310-nm Single-Mode MT650A-ST-R3 1310-nm Single-Mode, -48-VDC MT653A-ST-D48-R3
T3 Fiber Optic Line Driver ST, Standalone
850-nm Multimode
MT619A-ST-R2
1310-nm Single-Mode MT618A-ST-R3
E3 Fiber Optic Line Driver, Standalone
1310-nm Single-Mode, 230-VAC
MT620AE-R2
T1/E1 Fiber Optic Line Driver ST, Card
850-nm Multimode
MT651C
1310-nm Single-Mode MT650C-R2
To rackmount your cards, you’ll need…
RackNest 2/14
115-VAC, Single Power Supply
RM110A
115-VAC, Dual Power Supply RM110A-2PS 230-VAC, Single Power Supply RM110AE
For optimum performance and a 20% savings, order…
Multimode Duplex Fiber Optic Cable, Riser, ST–ST,
Custom Lengths
EFN110-STST
Single-Mode Duplex Fiber Optic Cable, PVC, ST–ST,
Custom Lengths
EFN5009
T1 Cable, DB15 Male/DB15 Male, Straight-Pinned,
10-ft. (3-m)
ETNMS02-0010
T1 Cable, DB15 Male/RJ-48C Male, Straight-Pinned,
10-ft. (3-m)
ETNMS03-0010
The tables below show the pinouts of the connectors on the T1/E1 Fiber Optic Line Drivers that carry the T1/E1 and dry­contact alarm leads. The pinning shown for the T1/E1 signals on the DB15 connector of the standalone models is widely used, so if you’re only using these signals, our standard cables should work.
The pinning of the dry-contact leads is proprietary. Their arrangement on DB15 is the same as that used by our earlier standalone fiber optic line drivers (MT610 through MT613), so if you already have cables built for those, they should still work. If you need cables incorporating these leads, please call us for a quote.
Technically Speaking
MT612A-ST
Standalone Card
Alarm
(on DB15) (on RackNest’s DB25) Pins 8 and 7 Pins 10 and 22 Minor alarm (normally closed) Pins 8 and 15 Pins 10 and 21 Minor alarm (normally open) Pins 6 and 5 Pins 13 and 25 Major alarm (normally closed) Pins 6 and 13 Pins 13 and 24 Minor alarm (normally open)
Buyer’s Guide
Dry-contact alarm leads (optional)
Standalone Card
(on RackNest’s Signal
(on DB15) 5-position terminal block)
N/A Top terminal
Ground (optional,
attach at one end only!)
Pin 1 Either TX terminal
Send Data Tip (Transmit Data A,
input to fiber optic line driver)
Pin 9 Either TX terminal
Send Data Ring (Transmit Data B,
input to fiber optic line driver)
Pin 3 Either RX terminal
Receive Path Tip (Receive Data A,
output from fiber optic line driver)
Pin 11 Either RX terminal
Receive Path Ring (Receive Data B, output from fiber optic line driver)
Buyer’s Guide
Balanced T1/E1 leads
Loading...