![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg1.png)
APRIL 2000
ME729A-FSP ME734A-MSP
ME729A-MSP ME735A-F
ME734A-F ME735A-M
ME734A-M ME735A-FSP
ME734A-FSP ME735A-MSP
Sync SHM-NPR MP
CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg2.png)
1
FCC INFORMATION
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if
not installed and used properly, that is, in strict accordance with the
manufacturer’s instructions, may cause interference to radio communication. It
has been tested and found to comply with the limits for a Class A computing
device in accordance with the specifications in Subpart J of Part 15 of FCC rules,
which are designed to provide reasonable protection against such interference
when the equipment is operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference, in which case
the user at his own expense will be required to take whatever measures may be
necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from
digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de classe A prescrites dans le Règlement sur le
brouillage radioélectrique publié par Industrie Canada.
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg3.png)
2
SYNC SHM-NPR MP
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes
de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más
allá a lo descrito en las instrucciones de operación. Todo otro servicio
deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama,
sofá, alfombra o superficie similar puede bloquea la ventilación, no se
debe colocar en libreros o gabinetes que impidan el flujo de aire por los
orificios de ventilación.
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg4.png)
3
NOM STATEMENT
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor
como radiadores, registros de calor, estufas u otros aparatos (incluyendo
amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del
tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen
del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no
sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del
aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en
su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg5.png)
4
SYNC SHM-NPR MP
TRADEMARKS USED IN THIS MANUAL
Any trademarks mentioned in this manual are
acknowledged to be the property of the trademark
owners.
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg6.png)
5
CONTENTS
Contents
1. Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Switch Locations. . . . . . . . . . . . . . . . . . . . . . . 11
3.2 Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . 12
4. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 Connection to the Twisted-Pair
Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1.1 Twisted-Pair Connection Using
RJ-11 or RJ-45 . . . . . . . . . . . . . . . . . . . . . 16
4.1.2 Twisted-Pair Connection Using
Terminal Blocks . . . . . . . . . . . . . . . . . . . 18
4.2 Connection to the RS-232 Interface . . . . . . . 26
4.2.1 Connection to a DTE Device . . . . . . . . . 26
4.2.2 Connection to a DCE Device . . . . . . . . . 26
4.3 Operating the Sync SHM-NPR MP . . . . . . . . 28
Appendix: RS-232 Pin Configurations . . . . . . . . . . 29
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg7.png)
6
SYNC SHM-NPR MP
1. Specifications
Protocol — Synchronous
Speed — 1200 to 19,200 bps
Distance — Wire Gauge
Speed (bps) 19 24 26
19,200 7.5 mi (12.1 km) 3.5 mi (5.6 km) 2.5 mi (4.0 km)
9600 10.0 mi (16.1 km) 3.5 mi (5.6 km) 2.5 mi (4.0 km)
4800 10.0 mi (16.1 km) 7.0 mi (11.2 km) 4.0 mi (6.4 km)
2400 10.0 mi (16.1 km) 8.5 mi (13.7 km) 5.0 mi (8.0 km)
1200 11.0 mi (17.7 km) 8.5 mi (13.7 km) 6.0 mi (9.7 km)
Surge Protection — 600W power dissipation at 1 ms
and response time less than 1 picosecond
Control Signals — RTS/CTS delay of 7 or 53 ms;
Carrier continuous or controlled by RTS; DCD
turns “On” after recognizing the receive signal
Clocking — Internal, external, or loopback derived
from the receive signal
Operation — 4-wire unconditioned twisted-pair, full-
or half-duplex
Connectors — (1) DB25 male or female and either
(1) 5-screw terminal lock, (1) RJ-11, or (1) RJ-45
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg8.png)
7
CHAPTER 1: Specifications
Transmit Level — -6 dBm
Range — Up to 11 miles (17.7 km)
Temperature — 32° to 140° F (0° to 60° C)
Humidity — 95% noncondensing
Power — No power required; uses ultra-low power
(6 volts required) from EIA data and control
signals—Pins 2, 4, 9, and 20 in DCE mode (the
Sync SHM-NPR MP does not operate in DTE
mode)
Size — 2.7"H x 2.1"W x 0.7"D (6.9 x 5.3 x 1.8 cm)
Weight—0.1 lb. (0.05 kg)
NOTE
The Sync SHM-NPR MP must be used in pairs. The Sync
SHM-NPR MP is compatible with the Mini Driver 4W-S
Series (ME750A-ME754A, ME756A).
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bg9.png)
8
SYNC SHM-NPR MP
2. Description
The Sync SHM-NPR MP features surface-mount
technology and a custom VLSI chip. It supports up to
12 drops and is powered by data only. It operates at
speeds from 1.2 to 19.2 kbps. The unit has the best
speed-to-distance ratio of any available data-powered
sync SHM—11 miles (17.7 km) at low data rates and
four miles (6.4 km) at 19.2 kbps over two 22-AWG
twisted-pair wires (conservatively rated).
The SHM-NPR operates at full- or half-duplex and uses
three clocking methods: internal, external, and
received loopback. It’s also transformer-isolated for
ground-loop protection. You can select RTS/CTS delay
of 7 or 53 ms, and carrier status of constantly on or RTScontrolled.
Ten models are available:
• Sync SHM-NPR MP (DB25) with Surge Protection
(4-Screw Terminal Block) (ME729A-MSP)
• Sync SHM-NPR MP (DB25) with Surge Protection
(4-Screw Terminal Block) (ME729A-FSP)
![](/html/8c/8cf4/8cf48afb9d3e144224831be5c0063b3ba9d8a6b6fad0c44b545ef5eb52a2feb0/bga.png)
9
CHAPTER 2: Introduction
• Sync SHM-NPR MP/RJ-11 (ME734A-M)
• Sync SHM-NPR MP/RJ-11 (ME734A-F)
• Sync SHM-NPR MP/RJ-11 (ME734A-MSP)
• Sync SHM-NPR MP/RJ-11 (ME734A-FSP)
• Sync SHM-NPR MP/RJ-45 (ME735A-M)
• Sync SHM-NPR MP/RJ-45 (ME735A-F)
• Sync SHM-NPR MP/RJ-45 with Surge Protection
(ME735A-MSP)
• Sync SHM-NPR MP/RJ-45 with Surge Protection
(ME735A-FSP)
Features
• New design uses a custom VLSI chip and
surface-mount technology.
• Internal, external, or receive loopback clocks
(switch-selected).
• Speeds up to 19.2 kbps.