Black Box ME480A-R2, ME485A, ME485AE, ME485A-D48 Specifications

1
Operate point-to-point over one or two UTPs.
Distances up to
10.1 miles for 2-wire models and 11.1 miles for 4-wire models.
Modular DCE-DTE interface cards for RS-232, RS-422/530, V.35, X.21, and G.703 connections.
2-wire card version available for use in our MicroRACK.
Use WAN Bridge Module with 4-wire driver to link LANs.
Configurable via DIP switches and terminal connection.
LEDs indicate DTE signals, network links, and test modes.
W
i
th their support for high data
rates, long distances, and multiple interfaces, the BLACK BOX
®
2-Wire and 4-Wire Modular Campus Drivers provide a number of point-to-point communication solutions. Whether your task is connecting two LANs over private campus or leased lines, extending a 64-kbps G.703 link, performing G.703 extension and interface conversion, or transferring high­speed data, these drivers can do it all.
The Modular Campus Drivers give you communication over either a single twisted pair (with the 2-wire models) or two twisted pairs (with the 4-wire versions). Offering a variety of switch­selectable synchronous data rates (and asynchronous data rates for the 2-wire models), the drivers are great for connecting two bridges or routers, or for similar campus networking applications at distances up to 10.1 miles (for the 2-wire models) or 11.1 miles (for the 4-wire model).
One of the Modular Campus Driver’s unique features is the
Key Features
2-WIRE/4-WIRE MODULAR CAMPUS DRIVERS
quick-change, plug-in DCE-to-DTE Interface Card. Several different models are available to provide connection to a variety of popular terminal interfaces: G.703, V.35, X.21, RS-422/-530, and RS-232. Each card has a 50-pin card-edge connector on one side and a serial port interface on the other. Use the Modular Campus Driver’s rear RJ­45 jack to connect the twisted-pair line.
The 2-Wire Modular Campus Drivers feature a V.52 bit-error­rate-test (BERT) pattern generator and incorporate local line loopback (LLB) and remote digital loopback (RDL) test modes.
The LLB test checks the operation of the local driver and is performed separately on each unit. Any data sent to the local driver in this test mode will be echoed (returned) back to the user device. For example, characters typed on the keyboard of a terminal will appear on the terminal screen.
The RDL test checks the performance of both the local and remote Modular Campus Drivers and the communication
link between them. Any characters sent to the remote driver in this test mode will be returned back to the originating device. For example, characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote driver and looped back.
For extended distances, the 2-Wire Modular Campus Drivers use automatic equalization, gain control, and echo cancellation. Data integrity is enhanced by transformer isolation and surge protection.
We also offer a BLACK BOX
®
MicroRACK version of the 2-Wire V.35 Modular Campus Driver (ME485C-35/B). Supporting one DTE interface connection and one 2-wire line connection, this economical card fits into and draws its power from the 2U-high MicroRACK chassis, which mounts cards in a midplane architecture. The module consists of a front card and a rear card. Both meet inside the rack chassis and plug into each other by way of 50-pin card-edge connectors.
Black Box Corporation • 1000 Park Drive • Lawrence, PA 15055-1018 • Tech Support: 724-746-5500 • www.blackbox.com e-mail: info@blackbox.com
© 2003. All rights reserved.
Black Box Corporation.
11/20/2003 #18203
The perfect drivers for high-speed leased-
line Internet links, LAN interconnection,
or campus networking.
2
Approvals: CE, UL®, cUL
Clocking: Internal, external, receive
Data Rates: ME480A-R2: 48, 56,
64, 72, 80, 112, 128, 144, or 160 kbps (switch-selectable);
ME485A, ME485AE, ME485A-D48,
ME485C-35/B: 32, 56, 64, or 128 kbps synchronous (switch-selectable), or 0 to
38.4 kbps asynchronous
Distance: See above right
Carrier Control: Constantly On or
Controlled By RTS
Diagnostics: ME480A-R2:
V.52-compliant bit-error-rate pattern (511/511E pattern) generator and detector with error injection mode; V.54­compliant; local analog loopback, digital loopback, remote digital loopback;
ME485A, ME485AE, ME485A-D48,
ME485C-35/B: Local analog loopback, remote digital loopback; V.52-compliant bit-error-rate pattern (511/511E pattern) generator and detector with error injection mode
Line Encoding: ME485A, ME485AE,
ME485A-D48, ME485C-35/B: 2B1Q with Integrated Echo Cancellation
RTS/CTS Delay: No delay, short delay
(4 to 9 ms), or long delay (33 to 71 ms)
Speed (Maximum):
ME480A-R2: 160 kbps; ME485A, ME485AE, ME485A-D48,
ME485C-35/B: Async: 38.4 kbps; Sync: 128 kbps;
Transmission Format:
ME480A-R2: Sync; ME485A, ME485AE, ME485A-D48,
ME485C-35/B: Async or sync
Specifications
Data Rate
Wire Gauge (miles/kilometers)
(kbps) 19 22 24 26
128 10.1 (16.3) 6.4 (10.3) 4.5 (7.2) 3.4 (5.5)
64 10.1 (16.3) 6.4 (10.3) 4.5 (7.2) 3.4 (5.5)
56 10.1 (16.3) 6.4 (10.3) 4.5 (7.2) 3.4 (5.5)
32 10.1 (16.3) 6.4 (10.3) 4.5 (7.2) 3.4 (5.5)
0 to 38.4 10.1 (16.3) 6.4 (10.3) 4.5 (7.2) 3.4 (5.5)
Data Rate
Wire Gauge (miles/kilometers)
(kbps) 19 22 24 26
160 8.1 (13) 5.9 (9.5) 4.1 (6.6) 3 (4.8)
144 8.5 (13.7) 6.1 (9.8) 4.4 (7.1) 3.1 (5)
128 9 (14.5) 6.2 (10) 4.6 (7.4) 3.2 (5.2)
112 9.2 (14.8) 6.3 (10.1) 4.8 (7.7) 3.2 (5.2)
80 9.2 (14.8) 6.4 (10.3) 5.2 (8.4) 3.2 (5.2)
72 10.8 (17.4) 6.6 (10.6) 5.5 (8.9) 3.4 (5.5)
64 11 (17.7) 6.8 (10.9) 5.5 (8.9) 3.4 (5.5)
56 11.1 (17.9) 6.8 (10.9) 5.5 (8.9) 3.4 (5.5)
48 10.8 (17.4) 6.6 (10.6) 5.4 (8.7) 3.3 (5.3)
ME485A and ME485C-35/B (2-Wire) Distance Table
ME480A-R2 (4-Wire) Distance Table
For more information on the MicroRACK, request Product Data Sheet 12915 or call Black Box Tech Support.
The 4-Wire Modular Campus Driver boasts built-in V.54 loopback tests (which can be activated from the front panel or the terminal interface), and a V.52 BERT pattern generator. Automatic equalization and gain control enhance data integrity. The line driver also features transformer isolation for protection against ground loops, as well as Silicon Avalanche Diodes to guard data and connected equipment against transient surges.
For the 4-Wire Modular Campus Driver, we also offer a WAN Bridge Module. This card, with its modular 10BASE-T connector, enables you to link two peer Ethernet LANs. Supporting transparent operation to higher­level protocols (such as TCP/IP and NetBIOS), the bridge module requires no configuration—it automatically discovers, loads, and deletes MAC addresses using its 512-MB onboard RAM.
For both 2- and 4-wire models, synchronous clocking options
TD RD CTS CD NS ER
LLB
511ER
RDL
511
DTR
TM
Transmission Line: Unconditioned
twisted pair or Local Area Data Circuits (LADS), 19 to 26 AWG; DC continuity not required
Interface: ME485A, ME485AE,
ME485A-D48, ME480A-R2:
RS-232, RS-422/530, V.35, X.21, or G.703 depending on interface card;
ME485C-35/B: V.35
Connectors: All standalone units:
(1) RJ-45 control, (1) RJ-45 line;
ME481C-232, ME481C-422:
(1) DB25 F, (1) card-edge;
ME481C-35, ME485C-35/B:
(1) M/34 F, (1) card-edge;
ME481C-X.21: (1) DB15 F,
(1) card-edge;
ME481C-G703, ME530A: (1) RJ-45,
(1) card-edge
Temperature Tolerance: Operating:
32 to 113°F (0 to 45°C)
Humidity Tolerance: 5 to 95%,
noncondensing
Power: ME485A: 115 VAC, 60 Hz;
ME485AE: 230 VAC, 50 Hz; ME485A-D48: 48 VDC, 5 watts; ME480A-R2: 115/230 VAC,
50/60 Hz, switchable;
ME485C-35/B: From the
MicroRACK
Surge Protection: 600W power
dissipation at 1 ms
Size: All standalone units:
7.3"H x 6.6"W x 1.6"D (18.5 x 16.8 x 4.1 cm);
ME485C-35/B:
Front card: 4.8"H x 3.1"W x 0.95"D
(12.2 x 7.9 x 2.4 cm);
Rear card: 3.3"H x 2.8"W x 0.95"D
(8.4 x 7.1 x 2.4 cm)
Weight: All standalone units:
2 lb. (0.9 kg);
ME485C-35/B:
Front card: 0.22 lb. (0.1 kg); Rear card: 0.12 lb. (0.05 kg)
include internal, external, and receive recovered clock. And configuration is made easier by two sets of eight externally accessible DIP switches. An RJ-45 (RS-232) control port on the driver‘s front enables you to use a menu­driven commands to configure the unit and initiate diagnostic tests via a VT100™ terminal or similar RS­232 DTE with terminal emulation. Once properly configured and installed, the drivers operate transparently.
MicroRACK 2-Wire V.35
Modular Campus Driver (ME485C-35/B)
Loading...
+ 1 hidden pages