Black Box ME1791A-F, ME1794A-F User Manual

Page 1
ME1791A-F ME1794A-F
Asynchronous Short
Ultra-Miniature
Range Modems
JULY 2003
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com
Page 2
Page 3
Versions
ME1791A-F, ME1794A-F
1. Features
Ultra-miniature asynchronous short range modems:
Ultra-miniature modems using hybrid technology
Asynchronous transmission up to 19.2 kbps
Transmission range up to 21 km (13 miles)
No AC power required
9-pin RS-232/V.24 connector
Can be used with both STP and UTP
Compact, lightweight, easy to install.
The following versions of the modem are available:
Application
ME1791A-F – modem with female DCE connector and terminal block line connector
ME1794A-F – modem with female DCE connector and RJ-45 line connector.
ME1791A-F,
ME1794A-F
4-wire
Async
Computer
ME1791A-F,
ME1794A-F
Asynchronous
Te rm in a l
Figure 1. Typical Application
2. Description
ME1791A-F and ME1794A-F, ultra-miniature asynchronous short range modems, are used for local data distribution, connecting full duplex asynchronous DTEs to computers. The modems ensure integrity of data transmission, using unconditioned 4-wire dedicated lines at data rates up to 19.2 kbps. It operates over distances up to 21 km (13 miles) depending on wire gauge and data rate (see Table 1).
Description 1
Page 4
ME1791A-F, ME1794A-F
Table 1. Typical Transmission Ranges
19 AWG 24 AWG 26 AWG Data Rate
[kbps]
19.2 14 9 6 4 4 3
9.6 14 9 6 4 5 3
4.8 14 9 7 4 5 3
2.4 16 10 8 5 7 4
1.2 21 13 11 7 8 5
[km] [miles] [km] [miles] [km] [miles]
The modems incorporate innovative circuitry design, which enables the units to operate without connection to the mains supply, by using ultra low power from the standard RS-232/V.24 data and control signal voltages. The modem operates fully even if only Transmit Data is connected (i.e. without the DTE sending Request to Send or Data Terminal Ready signals). Both positive and negative signals are generated in compliance with RS-232/V.24 standards, regardless of constantly low or constantly high Transmit Data. Table 2 provides the DCE connector pinout.
Table 2. DCE Connector Pinout
Pin Designation Function
1 DCD Data Carrier Detect (output)
2 RD Receive Data (output)
3 TD Transmit Data (input)
4 DTR Data Terminal Ready (input)
5 GND Ground
6 DSR Data Set Ready (output)
7 RTS Request To Send (input)
8 CTS Clear To Send (output)
9 RI (+V)
The low transmit level minimizes cross-talk onto adjacent circuits within the same cable. Data is transmitted and received at a balanced impedance, ensuring excellent immunity to circuit noise.
The line side of the modems offers connection to the RS-232 plug ground. This may be connected to the shield of the STP wiring to provide end-to-end ground continuity. Table 3 provides the pinout of the RJ-45 line connector.
2 Description
Page 5
ME1791A-F, ME1794A-F
Table 3. Line Connector Pinout (RJ-45)
Pin Function
1 Not connected
2 Ground
3 RCV-
4 XMT-
5 XMT+
6 RCV+
7 Not connected
8 Not connected
3. Technical Specifications
Line Interface
DCE Interface
Power
Line Type
Transmission Mode
Transmission Level
Range
Connector
Type
Data Rate
Control Signals
Connector
4-wire unconditioned dedicated line (two twisted pairs)
Asynchronous, full duplex
-6 dBm
See Table 1
ME1791A-F: 4-screw terminal block
ME1794A-F: RJ-45
RS-232/V.24
Up to 19.2 kbps
DSR (Circuit 107) and DCD (Circuit 109) turn on immediately after the terminal raises DTR (Circuit 108.2); CTS (Circuit 106) turns on immediately after the DTE raises RTS (Circuit 105)
D-type, 9-pin, female
No external power supply is required; the modems use ultra low power from the RS-232/V.24 data and control signals
Physical
Environment
Technical Specifications 3
Height
Width
Depth
Weight
Temperature
Humidity
19.8 mm / 0.8 in
31 mm / 1.2 in
61 mm / 2.4 in
26g / 0.9 oz
0–50°C (32–122°F)
Up to 90%, non-condensing
Page 6
ME1791A-F, ME1794A-F
4. Installation
Installation of the modems is simple and straightforward, just follow these steps:
1. Connect the 4-wire dedicated line to the line connector; transmit pair to ‘XMT’ and receive pair to ‘RCV’.
Observe the following pin polarity between the local and remote units:
Local XMT+ connected to remote RCV+
Local XMT- connected to remote RCV-
Local RCV+ connected to remote XMT+
Local RCV- connected to remote XMT-.
2. Connect the modems directly to the 9-pin connector of the DTE or the computer and fasten with the two screws – one on each side of the modem connector.
4 Installation
Loading...