Manual Documentation Number: MDR3243A-807 21
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018
www.blackbox.com -- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746
D8 I/O Settings
DI8 Configuration. Select/Read
options for the DI8 line (pin 9) of
the RF module.
0 – 1
0 = Disabled
3 = DI
(1,2,4 & 5 n/a)
0
D7 (v1.x80*) I/O Settings
DIO7 Configurat ion. Select/Read
settings for the DIO7 line (pin 12)
of the RF module. Options include
CTS flow control and I/O line
settings.
0 – 1
0 = Disabled
1 = CTS Flow
Control
2 = (n/a)
3 = DI
4 = DO low
5 = DO high
1
D6 (v1.x80*) I/O Settings
DIO6 Configurat ion. Select/Read
settings for the DIO6 line (pin 16)
of the RF module. Options include
RTS flow control and I/O line
settings.
0 – 1
0 = Disabled
1 = RTS flow
control
2 = (n/a)
3 = DI
4 = DO low
5 = DO high
0
D5 (v1.x80*) I/O Settings
DIO5 Configurat ion. Configure
settings for the DIO5 line (pin 15)
of the RF module. Options include
Associated LED indicator (blinks
when associated) and I/O line
settings.
0 – 1
0 = Disabled
1 = Associated
indicator
2 = ADC
3 = DI
4 = DO low
5 = DO high
1
D0 - D4
(v1.xA0*)
I/O Settings
(DIO4 -DIO4) Configuration.
Select/Read settings for the
following lines: AD0/DIO0 (pin
20), AD1/DIO1 (pin 19),
AD2/DIO2 (pin 18), AD3/DIO3
(pin 17), AD4/DIO4 (pin 11).
Options include: Anal og-to-digital
converter, Digital Input and Digital
Output.
0 – 1
0 = Disabled
1 = (n/a)
2 = ADC
3 = DI
4 = DO low
5 = DO high
0
IU (v1.xA0*) I/O Settings
I/O Output
Enable.Disables/Enables I/O data
received to be sent out UART.
The data is sent using an API
frame regardless of the current
AP parameter value.
0 – 1
0 = Disabled
1 = Enabled
1
IT (v1.xA0*) I/O Settings
Samples before TX.Set/Read the
number of samples to collect
before transmitting data.
Maximum number of samples is
dependent upon the number of
enabled inputs.
1 - 0xFF 1
IS (v1.xA0*) I/O Settings
Force Sample.Force a read of all
enabled inputs (DI or ADC). Data
is returned through the UART. If
no inputs are defined (DI or ADC),
this command will return error.
8-bit bitmap (each
bit represents the
level of an I/O line
setup as an
output)
-
22 Manual Documentation Number: MDR3243A-807
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018
www.blackbox.com -- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746
IO (v1.xA0*) I/O Settings
Digital Output Level.Set digital
output level to allow DIO lines that
are setup as outputs to be
changed through Command
Mode.
- -
IC (v1.xA0*) I/O Settings
DIO Change
Detect.Enables/Disables the
monitoring of the change detect
feature on DIO line s 0-7. If a
change is detected, data is
transmitted with DIO data only.
Any samples queued and waiting
for transmission will be sent first.
0 - 0xFF [bitfield]
0
(disabled)
IR (v1.xA0*) I/O Settings
Sample Rate. Set/Read sample
rate. When set, this parameter
causes the module to sample all
enabled inputs at a specified
interval.
0 -0xFFFF [x 1
msec]
0
AV (v1.xA0*) I/O Settings
ADC Voltage Reference. <XBeePRO only> Set/Read ADC
reference voltage switch.
0 – 1
0 = VREF pin
1 = Internal
0
IA (v1.xA0*)
I/O Settings {I/O
Line Passing}
I/O Input Address. Set/Read
addresses of module to which
outputs are bound. Setting all
bytes to 0xFF will not allow any
received I/O packet to change
outputs. Setting address to
0xFFFF will allow any received
I/O packet to change outputs.
0 0xFFFFFFFFFFFF
FFFF
0xFFFFFF
F
FFFFFFFF
F
T0 - T7
(v1.xA0*)
I/O Settings {I/O
Line Passing}
(D0 - D7) Output Timeout.
Set/Read Output timeout values
for lines that correspond with the
D0 - D7 parameters. When output
is set (due to I/O line passing) to
a non-default level, a timer is
started which when expired will
set the output to it default level.
The timer is reset when a valid
I/O packet is received.
0 - 0xFF
[x 100 ms]
0xFF
P0
I/O Settings {I/O
Line Passing}
PWM0 Configuration.
Select/Read function for PWM0
pin.
0 – 2
0 = Disabled
1 = RSSI
2 = PWM Output
1
P1 (v1.xA0*)
I/O Settings {I/O
Line Passing}
PWM1 Configuration.
Select/Read function for PWM1
pin.
0 – 2
0 = Disabled
1 = RSSI
2 = PWM Output
0
M0 (v1.xA0*)
I/O Settings {I/O
Line Passing}
PWM0 Output Level. Set/Read
the PWM0 output level.
0 - 0x03FF -
M1 (v1.xA0*)
I/O Settings {I/O
Line Passing}
PWM1 Output Level. Set/Read
the PWM0 output level.
0 - 0x03FF -
PT (v1.xA0*)
I/O Settings {I/O
Line Passing}
PWM Output Timeout. Set/Read
output timeout value for both
PWM outputs. When PWM is set
to a non-zero value: Due to I / O
0 - 0xFF
[x 100 ms]
0xFF