Bridges 10BASE-T/100BASE-TX Ethernet across full or Fractional T1
or E1 in unframed or framed mode.
Ethernet Auto MDI/MDI-X function so no crossover cables are needed.
DIP switches for easy configuration.
•
Customer
Support
Information
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) •
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 •
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •
Web site: www.blackbox.com • E-mail: info@blackbox.com
Page 2
1-Port T1/E1 Ethernet Network Extender Kit
Trademarks Used in this Manual
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
Page 2
We‘re here to help! If you have any questions about your application
or our products, contact Black Box Tech Support at 724-746 -5500
or go to blackbox.com and click on “Talk to Black Box.”
You’ll be live with one of our technical experts in less than 30 seconds.
724-746-5500 | blackbox.com
Page 3
FCC and IC RFI Statements
Federal Communications Commission and Industry Canada Radio Frequency Interference
Statements
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict
accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to
comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules,
which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own
expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio
Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de
la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Page 3
Page 4
1-Port T1/E1 Ethernet Network Extender Kit
Normas Oficiales Mexicanas (NOM) Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca
de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación.
Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico
sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes
que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros
aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como
se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados
sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
Page 4
724-746-5500 | blackbox.com
Page 5
European Community (CE) Electromagnetic Compatibility Directive
This equipment has been tested and found to comply with the protection requirements of European Emission
Standard EN55022/EN61000-3 and the Generic European Immunity Standard EN55024.
2.2 Features ......................................................................................................................................................................................... 8
2.3 What’s Included ............................................................................................................................................................................. 8
2.4 LED Description .............................................................................................................................................................................. 9
2.5 Front and Back Panels ..................................................................................................................................................................... 9
Indicators: (6) LEDs: Power, E1, T1, LOS, 10/100M, LAN
Power: Input: 110/220 VAC, 50–60 Hz
Temperature Tolerance: Operating: 32 to 122° F (0 to 50° C)
Humidity Tolerance: 5 to 95% noncondensing
Size: 1.7"H x 9.8"W x 5.9"D (4.3 x 25 x 15 cm)
Page 7
Page 8
1-Port T1/E1 Ethernet Network Extender Kit
2. Overview
2.1 Introduction
The LR0301A 1-Port T1/ E1 Network Extender (LR0301A-KIT) is an Ethernet extender that converts protocols and data from
Fractional T1/E1 to Ethernet 10BASE-T/100BASE-TX interfaces. It’s a symmetrical broadband solution for Intranet LAN-to-LAN
connection with Nx64kbps bandwidth. The pair of extenders included with this kit acts as a bridge, enabling you to link two
Ethernet networks across T1/E1. It supports T1/E1 framed and unframed modes with different line codes plus line build-out (LBO)
capability.
Because you are using leased lines provided by your telco, there are no distance limitations—you can extend your network anywhere you can get a T1 line. It’s ideal for various Ethernet LAN services (for example, videoconferencing, routing, etc.) through a
fractional T1/E1 network.
2.2 Features
• Supports Fractional T1/E1 framed and unframed modes
• BNC connectors for E1 unbalanced 75 ohm
• RJ-48 connector for E1 balanced 120 ohm and T1 balanced 100 ohm
• Autosensing, autonegotiating for 10BASE-T/100BASE-TX and half-/full-duplex
• Ethernet Auto MDI /MDI-X function for auto Tx/Rx swap so you don’t need a crossover cable
• 6 LED indicators for status monitoring
• DIP switches make configuration easy
• Plug-and-play
2.3 What’s Included
Your package should include the following items. If anything is missing or damaged, contact Black Box Technical Support at
724-746-5500.
• (2) LR0301A 1-Port T1/ E1 Network Extenders
• (2) Power cords
• (2) CAT5e Ethernet cables
• This user’s manual on CD-ROM
Page 8
724-746-5500 | blackbox.com
Page 9
2.4 LED Descriptions
LED Color Function
POWER Green Lit when power is on.
E1 Green Lit when E1 is selected (SW1-1 is OFF).
T1Green Lit when T1 is selected (SW1-1 is ON).
LOSRed Lit when signal is lost for selected E1/T1.
10/100MGreenLit when Ethernet is connected at 100 Mbps.
LANGreenLit when Ethernet is connected.
2.5 Front and Back Panels
Chapter 2: Overview
Table 2-1. Indicators.
Off when Ethernet is connected at 10 Mbps.
Blinks when transmitting/receiving data.
Reset Button
LED Indicators
Power Switch
DIP Switches (SW2-1–SW2-8)
Power Input
DIP Switches (SW1-1–SW1-8)
Figure 2-1. Front panel.
E1 BNC
Interface
Figure 2-2. Rear panel.
Ethernet Port
E1/T1 RJ-48
Interface
Page 9
Page 10
1-Port T1/E1 Ethernet Network Extender Kit
3. Installation
The 1-Port T1/ E1 Network Extender uses DIP switches for fast and easy configuration, so it can be installed quickly. Follow the
steps listed below to complete the installation and configuration. There are two external DIP switches on the front of the unit and
four internal DIP switches on the circuit board inside the unit. You will use the external DIP switches for both full and Fractional
T1/E1. You will only use the internal DIP switches for Fractional T1/E1 configuration.
1. Select the Fractional E1/ T1 interface configurations via SW1-1–SW1-7 DIP switches. The default setup is T1. The DIP
switches are on the front panel. Refer to Figure 3-1 and Table 3-1 to see the DIP switches’ locations and definitions.
Figure 3-1. SW1-1–SW1-7 DIP switches.
NOTE: Table 3-1 describes DIP switches SW1-1–SW1-7. Tables 3-2 through 3-5 describe these switches in more detail. Table 3-5
also describes DIP switch SW2-1.
Table 3-1. SW1-1–SW1-7 DIP switches.
DIP SwitchesOFFONFunction
SW1-1E1T1E1/ T1 selection
SW1-2See Table 3-2See Table 3-2Impedance
SW1-3See Table 3-3See Table 3-3Frame Mode
SW1- 4See Table 3-3See Table 3-3Frame Mode
SW1-5See Table 3-4See Table 3-4Line Code
SW1- 6See Table 3-5See Table 3-5LBO
SW1-7See Table 3-5See Table 3-5LBO
Table 3-2. Impedance configuration.
SW1-1SW1-2Impedance
OFFON75 ohm
OFFOFF120 ohm
ONOFF100 ohm
ONON100 ohm
Page 10
724-746-5500 | blackbox.com
Page 11
Chapter 3: Installation
Table 3-3. Frame mode configuration.
SW1-1SW1-3SW1-4Frame Mode
OFFOFFOFE1 Unframed
OFFONOFFE1 CRC4
OFFOFONE1 CAS
OFFONONE1 CRC4+CAS
ONOFFOFFT1 Unframed
ONONOFFT1 SF
ONOFFONT1 ESF
Table 3-4. Line code configuration.
SW1-1SW1-5Line Code
OFFOFFHDB3
OFFONAMI
ONOFFB8ZS
ONONAMI
Table 3-5. DS-1 LBO and DSX-1 transmit pulse template.
SW1-1SW1-6SW1-7SW1-8SW2-1E1 or DS1/DSX-1 LBO
OFFXXXXE1
ONOFFOFFOFFOFFDS-1, 0 dB, LBO
ONONOFFOFFOFFDS-1, 7.5 dB, LBO
ONOFFONOFFOFFDS-1, 15 dB, LBO
ONONONOFFOFFDS-1, 22.5 dB, LBO
ONXXONOFFDSX-1, 0–133 feet
ONXXOFFONDSX-1, 133–266 feet
ONOFFOFFONONDSX-1, 266–399 feet
ONONOFFONONDSX-1, 399–533 feet
ONXONONONDSX-1, 533–655 feet
Page 11
Page 12
1-Port T1/E1 Ethernet Network Extender Kit
2. Connect the T1/E1 line to the BNC or RJ-48 connectors on the back panel. Figure 3-2 describes the RJ-48 pin assignment.
Pin 4 and Pin 5 (to input of demarc)
Pin 1 and Pin 2 (to output of demarc)
Figure 3-2. RJ-48 port pin assignment.
3. Connect the Ethernet cable to the RJ-45 LAN connector.
4. Connect the power cord to the AC outlet and turn on the power switch.
5. The T1/E1 and LAN LED indicators will light and the LAN indicator will flash to show the Ethernet data activity.
The LOS LED indicator will light RED when E1/T1 is in Loss of Signal.
Page 12
724-746-5500 | blackbox.com
Page 13
Chapter 4: DIP Switches
4. DIP Switches
4.1 Definition of DIP switches
Table 4-1 describes the DIP switches that are located on the extender’s front panel. You will use these switches for either full or
Fractional T1/E1.
Table 4-1. Description of DIP switches for full or Fractional T1/E1.
DIP SwitchesOFFONFunction
SW1-1E1T1T1/E1 selection
SW1-2See Table 3-2See Table 3-2Impedance
SW1-3See Table 3-3See Table 3-3Frame Mode
SW1- 4See Table 3-3See Table 3-3Frame Mode
SW1-5See Table 3-4See Table 3-4Line Code
SW1- 6See Table 3-5See Table 3-5LBO
SW1-7See Table 3-5See Table 3-5LBO
SW1- 8See Table 3-5See Table 3-5DSX-1
SW2-1See Table 3-5See Table 3-5DSX-1
SW2-2ReservedReservedReserved
SW2-3ReservedReservedReserved
SW2-4ReservedReservedReserved
SW2-5Nx64Nx56(T1 only)64K/56K Channel
SW2-6FullE1/T1 FractionalE1/T1 Fractional
SW 2-7All zerosAll onesStuff bits
SW2-8InternalExternalE1/T1 Clock Mode
Page 13
Page 14
1-Port T1/E1 Ethernet Network Extender Kit
The SW4-1–4-8, SW5-1–5-8, SW6-1–6-8, SW7-1–7-8 DIP switches are on the PC board. You need to open the top of the case to
configure these DIP switches. Refer to the Figure 4-1 to see the DIP switches’ locations. DIP switch “ON” means selected, and
“OFF” means unselected.
NOTE: SW4-1–4-8, SW5-1–5-8, SW6-1–6-8, and SW7-1–7-8 DIP switches are active only in Fractional T1 or Fractional E1 mode.
Tables 4-2 and 4-3 describe their functions.
Figure 4-1. SW4-1–4-8, SW5-1–5-8, SW6-1–6-8, and SW7-1–7-8 DIP switches.
NOTE: SW4-1 (Channel 1) is NOT available, and must be set to“OFF”. SW6-1 (Channel 17) can be selected “ON”
only when E1 CRC4 framing mode is selected. SW4–SW7 DIP switches defaults are set to “OFF.”
4.2 Factory Default DIP Switch Configuration
The factory default DIP switches setting are shown in Table 4-4. Before you change any settings, make sure every parameter and
all the configurations for both pairs of T1/E1 Ethernet Network Extenders are the same. Call Black Box Tech Support for details.
Table 4-4. Factory default configuration.
DIP SwitchesON/OFFDIP SwitchesON/OFF
SW1-1ON ( T1)SW2-1OFF
SW1-2OFF (100 ohm)SW2-2OFF
SW1-3OFF (Unframed)SW2-3OFF
SW1- 4OFF (Unframed)SW2-4OFF
SW1-5OFF (B8ZS)SW2-5OFF (Nx64)
SW1- 6O FF (DS1)SW2-6OFF (Full T1)
SW1-7OFF (0 db)SW2-7OFF (All zeros)
SW1- 8OFF (LBO)SW2-8OFF (Internal)
Page 15
Page 16
Black Box Tech Support: FREE! Live. 24/7.
Tech support the
way it should be.
Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com.
About Black Box
Black Box Network Services is your source for an extensive range of networking and infrastructure products. You’ll find everything
from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by
free, live 24/7 Tech support available in 30 seconds or less.