technical support 24 hours aday, 7 days a week: Callor fax
Mailing address:, 1000 Park Drive, Lawrence, PA15055-1018
Web site:E-mail:
Black Box Corporation
www.blackbox.cominfo@blackbox.com
FCC AND ICRFI STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFEREN CE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly,
that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio
communication. It has been tested and found to comply with the limits for a Class A computing device in
accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when the equipment is operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause interference, in which case the user at his
own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out
in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radio électriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radio électrique publié par
Industrie Canada.
EUROPEANUNION DECLARATIONOF CONFORMITY
This equipment complies with the requirements of the European EMC Directive 89/336/EEC.
CAUTION
Circuit devices are sensitive to static electricity, which can damage their delicate
electronics. Dry weather conditions or walking across a carpeted floor may cause you
to acquire a static electrical charge.
To protect your switch, always:
• T ouch your computer’s met al chassis to ground the st atic electrical charge before you
pick up the switch.
• Pick up the switch by holding it on the left and right edges only.
1
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement)
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótanomojado o
cerca de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones
deoperación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del
aparatoeléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar
enlibreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufasu
otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo deoperación, o
como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por
objetoscolocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios
deventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato;o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
2
TRADEMARKS USED IN THIS MANUAL
ST is a registered trademark of AT&T.
BLACK BOX and the Double Diamond logo are registered trademarks of BB Technologies, Inc.
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark
owners.
TRADEMARKS USED IN THIS MANUAL
3
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
1. Specifications
Standards: IEEE802.3u 10/100Base-TX, 100Base-FX, IEEE802.3af Power over Ethernet
UTP Cable: Cat. 5 cable or up, up to100 meter
Fiber Cable: 50/125, 62.5/125 or 100/140
8.3/125, 8.7/125, 9/125 or 10/125
PoE Power Reception Supports: Endpoint: via TP pin 1, 2, 3, 6
Midspan: via TP pin 4, 5, 7, 8
LED Indicators: POWER, PoE, TP LNK/ACT, 100, FX LNK/ACT, FDX/COL
Data Transfer Rate: 148,800 pps at 100 Mbps; 14,880 pps at 10 Mbps
Flow Control: IEEE802.3x compliant for full duplex; Backpressure flow control for half-duplex
Power Requirement: 60mA@-48VDC from IEEE802.3af PSE or PoE injector
Temperature Tolerance: 32˚ to 122˚F (0˚ to 50˚C)
Relative Humidity: 5% to 90%
Size: 1"H x 2.8"W x 3.7"D (26.2 x 70.3 x 94 mm)
μ
m multi-mode
μ
m single-mode
NOTE
For connecting this device to Router, Bridge or Switch, please
refer to the corresponding device's Technical Manual.
4
CHAPTER 2: Overview
2. Overview
2.1 Introduction
IEEE 802.3u 100Mbps Fast Ethernet supports two types of media, 10/100Base-TX and 100Base-FX, for network
connection. LFP (Link Fault Pass Through) feature enhances the TP-Fiber Link integrity and conformity.
Either one of TP or Fiber port is in link-fail state, the LFP converter forces the other port to be at link-disabled
state. Comply with IEEE 802.3af, its advanced auto-sensing algorithm enables taking power form IEEE 802.3af
Power Source Equipment (PSE) or Power over Ethernet (PoE) injector. It also supports high safety with short
circuit protection and power-in auto-detection (power from AC/DC power adapter or PSE device).
2.2 Model Description
Part Number Single/Multi Mode Connector Type Wavelength Transmission Distance
LPD500A Multi Mode SC Type 1310 nm 2 km
LPD501A Multi Mode ST Type 1310 nm 2 km
LPD502A Single Mode SC Type 1310 nm 20 km
LPD503A Single Mode ST Type 1310 nm 20 km
LPD506A Single Mode BiDi Type 1310 nm 20 km
LPD507A Single Mode BiDi Type 1550 nm 20 km
NOTE
AC-DC +5V Adapter is available upon request.
2.3 What’s Included
Your package should contain the following items. If anything is missing or damaged, please contact Black Box
at 724-746-5500.
• PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
• CD-ROM containing this user’s manual in PDF format
5
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
2.4 Hardware Description
Figure 2-1 shows the PD PoE 10/100BASE-TX to 100BASE-FX Media Converter’s front panel. The LED
indicators in the figure are described in Table 2-1.
LED Indicators
TP Port Fiber Port
LEDColorFunction
FX LNK/ACT Green
FX
Amber
FDX/COL
TP LNK/ACT Green
TP 100 Green
PWR Green
Figure 2-1. Front panel.
Table 2-1. LED indicators.
Lit when fiber connection is good
Blinks when fiber data is present
Lit when full-duplex mode is active
Off when half-duplex is active
Blinks when collision is present
Lit when TP connection is good
Blinks when TP data is present
Lit when TP speed is 100Mbps
Off when TP speed is 10Mbps
Lit when +5V power is coming up
6
The media converter’s rear panel is shown in Figure 2-2.
5V DC
CHAPTER 2: Overview
DC Jack
DC jack’s central post is 2.5 mm wide.
DC Jack: 2.5 mm
DC Input: +5V
Figure 2-2. Rear panel.
DIP Switches
7
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
3. Installing the Converter
3.1 Installing Instruction
CAUTION
Wear a grounding device to avoid damage from electrostatic discharge.
Be sure that the power switch is OFF before you connect the power
cord to the power source.
1. Install the TP media cable to the IEEE 802.3af PSE device or PoE injector. (See Figure 3-1)
2. Install the media cable for network connection.
NOTE
Please make sure that the power of PSE device is turned on, or else the
converter will not work.
3. In case where no 802.3af PSE is available or PSE with PoE power fails, you may install an AC-DC adapter for
a backup solution.
CAUTION
Do not connect PSE TP with PoE and the AC-DC adapter at the same
time.
Verify that the AC-DC adapter conforms to your country AC power
requirement and then insert the power plug.
4. Install the media cable for network connection.
8
100BASE-FX fiber network
CHAPTER 3: Installing the Converter
PD PoE 10/100BASE-TX to
100BASE-FX Media Converter
Fiber Optic
Cat.5 Cable
PSE Device
Figure 3-1 Connection among PSE PoE Converter and TP Cables
Figure 3-2 Endpoint PSE RJ-45 Male Connector
IEEE 802.3af assigns pairs on the RJ-45 connector and Cat.5 cable of
Endpoint PSE.
Endpoint: -48V via TP pin 1, 2, 3, 6
Midspan: -48V via TP pin 4, 5, 7, 8
NOTE
9
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
3.2 Connecting to TP, Fiber Device
Converter TP Port 10/100 TP
AUTO, FORCE selectable: Bit 1, 2, 3 of S1
a. AUTO: 10/100 NWay Auto-negotiation
b. FORCE: 100 or 10, FDX or HDX
Converter Fiber Port 100FX
100Mbps duplex selectable: Bit 5 of S1
a. FDX for 100FDX fiber link partner, default
b. HDX for 100HDX fiber link partner
S1-5 Fiber port duplex : 100FDX(default) or 100HDX
NOTE
1. S1-2 and S1-3 will take effect only when S1-1 is set at TP-FORCE.
2. S1-5 must be set to 100FDX for Single Fiber Model.
Warning
When TP Nway port is connected to TP 100FDX(force mode) instead of
Nway partner, it will result in 100HDX mode with invalid collision
signal.
Ensure that all network nodes are configured at an identical operation
mode. Improper operation and flow control mode between TP and
Fiber port connections will render the LAN to work poorly.
10
CHAPTER 3: Installing the Converter
3.3 Cable Connection Parameter
100Base-X network allows 512-bit time delay between any two node-stations in a collision domain. Switch-based
Media Converter breaks up TP and Fiber segments’ collision domain to extend the cabling distance.
TP Cable Limitations: Cat. 5 and up to 100m
Converter Fiber Cable Limitations:
Multi-mode Half-duplex 412 m
Multi-mode Full-duplex 2 km
Single-mode Half-duplex 412 m
Single-mode Full-duplex 20 km
11
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
4. Link Fault Pass Through
This media converter supports link fault pass through (LFP) in TX/FX converter application. Link status on
one port is propagated to the other port to notice the remote nodes. If TP port is unplugged, this converter
stops transmission on fiber port. This causes the remote fiber node link to fail. LED shows the link failure on
both TP and fiber ports. If fiber link fails, this converter restarts auto-negotiation on TP port but always stays in
the link failure state. This causes the remote TP node link to fail. LED also shows the link failure on both TP
and fiber ports. Refer to Figure 4-1 shown below for the normal status when the link succeeds. Also refer to
Figure 4-2 and Figure 4-3 for the erroneous status when TP Cable A, Fiber Cable B or Fiber Cable C fails to
connect.
NOTE
● indicates LNK/ACT LED Lit
○ indicates LNK/ACT LED Off
Ethernet Switch
B A
LFPLFP
TP Cable TP Cable
C
Fiber
Cable
Ethernet Switch Remote Station
Ethernet Switch
Figure 4-1 Normal status via a pair of LFPs
B
LFPLFP
TP Cable TP Cable
Figure 4-2 The status as TP Cable A is broken
C
Fiber
Cable
A
Ethernet Switch Remote Station
12
Ethernet Switch
The LFP (Link Fault Pass Through) function works only when both
two converters own this capability in pairs. Furthermore, both LFP
converters should be supplied only by the same
manufacturer/vender. The connection coming from LFP converters
with odd models or non-LFP converters will cease the LFP function.
CHAPTER 4: Link Fault Pass Through
B
A
LFPLFP
TP Cable TP Cable
Figure 4-3 The status as Fiber Cable B or C is broken
C
Warning
Ethernet Switch Remote Station
13
PD PoE 10/100BASE-TX to 100BASE-FX Media Converter
5. Troubleshooting
5.1 Calling Black Box
If you determine that your switch is malfunctioning, do not attempt to alter or repair the unit. It contains no
user-serviceable parts. Contact Black Box at 724-746-5500.
Before you do, make a record of the history of the problem. We will be able to provide more efficient and
accurate assistance if you have a complete description, including:
• the nature and duration of the problem.
• when the problem occurs.
• the components involved in the problem.
• any particular application that, when used, appears to create the problem or make it worse.
5.2 Shipping and Packaging
If you need to transport or ship your PD PoE 10/100BASE-TX to 100BASE-FX Media Converter:
• Package it carefully. We recommend that you use the original container.
• If you are shipping the PD PoE 10/100BASE-TX to 100BASE-FX Media Converter for repair, make sure you
include everything that came in the original package. Before you ship, contact Black Box to get a Return
Authorization (RA) number.
14
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.