Black Box LMC11032A, DFCS XGT+ User Manual

LMC11032A LMC11032AE LMC11042A LMC11042AE
DFCS XGT+ Stand Alone Module
Converts 10GBASE-T Ethernet to SFP+ or XFP Fiber
Supports Pluggable 10 Gigabit Transceivers
- RJ45 to SFP+
- RJ45 to XFP
Customer
Support
Information
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: www.blackbox.com • E-mail: info@blackbox.com
DFCS XGT+ Standalone Module NOM Statement
FEDERAL COMMUNICATIONS COMMISSION AND
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy,
and if not installed and used properly, that is, in strict accordance with the
manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing
device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference
when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be neces-
sary to correct the interference.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise
emis sion from digital apparatus set out in the Radio Interference Regulation
of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes
de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá
724-746-5500 | blackbox.com
Page 2
DFCS XGT+ Standalone Module
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios
de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea
usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato;o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
TRADEMARKS USED IN THIS MANUAL
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
Page 3
724-746-5500 | blackbox.com
DFCS XGT+ Standalone Module
This User Manual describes the functions of the DFCS XGT+ Rev 1.
Product Overview
The DFCS XGT+ is a 10 Gigabit Ethernet media converter with one 10GBASE-T RJ-45 port
and one pluggable transceiver port that provides copper-to-ber and copper-to-copper media conversion. Copper-to-ber conversion is achieved with XFP or SFP+ ber transceivers. Copper-to-copper conversion is achieved with a CX4 XFP transceiver.
The XGT+ supports high-power (power level 4) XFP transceivers, and the latest generation of wavelength tunable DWDM XFP transceivers.
Installation Procedure
1) Congure DIP-switches
2) Install Standalone Module and Connect Cables
3) Verify Operation
1) CONFIGURE DIP-SWITCHES
DIP-SWITCH BANK 1
The location of the DIP-switches is shown in Figure 1.
The function of DIP-switch Bank is outlined in Figure 2.
Switch
SW1 Normal P1 Loopback Enabled
SW2 Normal P2 Loopback Enabled
SW3 Normal P2 Short Range
SW4 Normal P1 Built-In Self Test (BIST)
DOWN
(Default)
UP
Figure 2: DIP-switch BANK 1 Denitions
SW1 - P1 LOOPBACK “P1-LB”
When this DIP-switch is in the DOWN position (factory default), port P1 loopback is disabled. When this DIP-switch is in the UP “P1-LB” position, loopback is enabled on port P1. When enabled, all data received on port P1 is transmitted out port P1 and the connection between port P1 and port P2 is interrupted.
NOTE: For the XFP model, simultaneous loopback of port P1 and port P2 requires the XFP transceiver to support lineside loopback capability.
Page 4
724-746-5500 | blackbox.com
Installation Procedure
SW2 - P2 LOOPBACK “P2-LB”
When this DIP-switch is in the DOWN position (factory default), port P2 loopback is disabled. When this DIP-switch is in the UP “P2-LB” position, loopback is enabled on port P2. When enabled, all data received on port P2 is transmitted out port P2 and the connection between port P2 and port P1 is interrupted.
NOTE: For the XFP model, simultaneous loopback of port P1 and port P2 requires the XFP transceiver to support lineside loopback capability.
SW3 - P2 Short Range
When this DIP-switch is in the DOWN position (factory default), port P2 short range feature is disabled. When disabled, port P2 will support up to 100 meters of CAT 6A cabling. When this DIP-switch is in the UP “P2-SR” position, port P2 will support up to 30 meters of CAT 6A
or better cabling in a reduced power consumption mode.
SW4 - P1 BIST (SFP+ Model Only)
When this DIP-switch is in the DOWN position (factory default), port P1 Built-In Self Test is disabled. When this DIP-switch is in the UP “P1-Tst” position, the port will transmit a Pseudo Random Bit Sequence (PRBS).
When two XGT+ converters are connected via port P1 (Port 1 to Port 1), the BIST function is supported. The XGT+ initiating BIST (DIP-switch SW4 UP) will generate and send a PRBS pattern out Port 1 to the other module. The receiving XGT+ will detect a good test pattern and return a PRBS acknowledgement test pattern back to the initiating XGT+.
A successful test will produce a green blinking (5Hz) P1 LB LED on the initiating XGT+ and a green blinking (1Hz) P1 LB LED on the receiving XGT+. If the initiating XGT+ does not receive a valid response, the P1 LB LED will be blinking amber (5Hz). When BIST is initiated, the trafc received on Port 2 of both converters will be discarded.
If loopback has been initiated, the self diagnostic circuit test DIP-switch will be ignored. If self diagnostic circuit test has been initiated, the loopback DIP-switches will be ignored.
DIP-SWITCH BANK 2
LINK MODES
SW1 and SW2 - LINK MODES
These DIP-switches configure the different link modes available on the XGT+. It is recommended to have link modes set to Link Segment (default setting - all DOWN) during the initial installation. After the circuit has been tested and operational, congure the module for the desired mode. Refer to Figure 3 for conguration options.
SW1 SW2 Function
DOWN DOWN Link Segment (default)
UP DOWN Asymmetrical Link Propagate P1 to P2
DOWN UP Asymmetrical Link Propagate P2 to P1
UP UP Symmetrical Link Propagate
Figure 3: DIP-switch BANK 2 Link Modes
724-746-5500 | blackbox.com
Page 5
DFCS XGT+ Standalone Module
SW3 and SW4 - RESERVED
These DIP-switches are for factory use only and must always remain in the DOWN (factory
default) position.
2) INSTALL STANDALONE MODULE AND CONNECT CABLES
a. The XGT+ is available as a standalone module with built-in mounting brackets. For
wall-mounting, attach the XGT+ to a wall, backboard or other at surface. For tabletop installations, place the unit on a at level surface. Attach the rubber feet to the bottom of the XGT+ to prevent the unit from sliding. Make sure the unit is placed in a safe, dry
and secure location.
To power the unit using the AC/DC adapter, connect the AC/DC adapter to an AC outlet.
Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm
DC barrel connector (center-positive) on the unit. Conrm that the unit has powered up properly by checking the power status LED located on the front of the unit.
To power the unit using a DC power source, prepare a power cable using a two conductor
insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the
length required. Strip approximately 3/8 of an inch of insulation from the power cable
wires. Connect the power cables to the unit by fastening the stripped ends to the DC power connector.
Connect the power wires to the DC power source. The Power LED should indicate the
presence of power.
WARNING: Note the wire colors used in making the positive and negative connections.
Use the same color assignment for the connection at the DC power source.
NOTE: If mounting with a safety ground attachment, use the safety ground screw at the
rear of the unit.
b. Insert the appropriate 10G SFP+ or XFP transceiver (depending on the model of the
module) into Port 1 receptacle on the XGT+. The release latch of the transceiver must
be in the closed position before insertion.
c. Connect an appropriate multimode or single-mode ber cable to the ber transceiver port
on the XGT+. It is important to ensure that the transmit (Tx) is attached to the receive side of the device at the other end and the receive (Rx) is attached to the transmit side.
d. When using copper CX4 XFP, connect the cable between the converter and external
device using the recommended copper CX4 cable.
e. Connect the RJ-45 port via a CAT 6A or better cable to a 10GBASE-T Ethernet device.
Page 6
724-746-5500 | blackbox.com
Installation Procedure
3) VERIFY OPERATION
Once the module has been installed and congured per steps 1 and 2, verify the module is operational by viewing the LED indicators.
Legend OFF State Color ON/Blinking State
Pwr Off – No power. Green Green – Power On
Green Green Solid – Fiber link (signal detect).
P1 Lk
P1 Stat
P1 LB
P2 Lk
P2 SR
P2 LB
Off – No Transceiver detected
or no ber link.
Off – Transceiver does not support digital diagnostic or no transceiver installed.
Off – Port loopback mode not enabled or congured.
Off – No Transceiver detected
or no ber link.
Off - Short Reach function is disabled.
Off – Port loopback mode not enabled or congured.
Amber
Green
Amber
Green
Amber
Green Green Solid – Fiber link
Amber
Green Green Solid – Short Reach function is enabled.
Green
Amber
Amber Blinking (1Hz) – Port is disabled due to
installed transceiver drawing more current than allowed.
Green Solid – Transceiver supports digital
diagnostic and no DDMI Alarm Detected.
Amber Solid – Transceiver supports digital
diagnostic and DDMI alarm detected.
Amber Blinking (1Hz) – Port is disabled due to
installed transceiver drawing more current than allowed.
Green Solid – Port set to Loopback mode and port in loopback.
Green Blinking (1 Hz) – Port responding to BIST activation with valid BIST response.
Green Blinking (5 Hz) – Port initiating BIST and receiving valid BIST response.
Amber Solid – Port set to loopback mode, but XFP does not support loopback
Amber Blinking (5 Hz) – Port initiating BIST and not receiving valid BIST response
Amber Blinking (1Hz) – Port is disabled due to
installed transceiver drawing more current than allowed.
Green Solid – Port set to Loopback mode and port in loopback.
Amber Solid – Port set to loopback mode, but loopback is not supported.
Figure 4: LED Indicators
724-746-5500 | blackbox.com
Page 7
Black Box Tech Support: FREE! Live. 24/7.
Tech support the way it should be.
Great tech support is just 30 seconds away at
724-746-5500 or blackbox.com.
About Black Box
Black Box Network Services is your source for an extensive range of networking
and infrastructure products. You’ll find everything from cabinets and racks and
power and surge protection products to media converters and Ethernet switches
all supported by free, live 24/7 Tech support available in 30 seconds or less.
©
Copyright 2013. All rights reserved. 040-L11030-001A 1/13