Black Box LMC100A-SC-R3, LMC100AE-SC-R3, LMC100A-SMSC-R3, LMC100AE-SMSC-R3, LMC100A-R3 User guide [en, es]

...
Page 1
LMC100A-SC-R3 LMC100AE-SC-R3 LMC100A-SMSC-R3 LMC100AE-SMSC-R3 LMC100A-R3 LMC100AE-R3 LMC100A-SM-R3 LMC100AE-SM-R3 LMC100A-SMSC-LH-R3 LMC100AE-SMSC-LH-R3 LMC100A-SFP
LMC100A-RJ-R3 LMC100AE-RJ-R3 LMC100A-SMSC-XLH-R3 LMC100AE-SMSC-XLH-R3 LMC100A-SMSC-SLH-R3 LMC100AE-SMSC-SLH-R3 LMC100A-LC-R2 LMC100AE-LC-R2 LMC100A-SMLC-R2 LMC100AE-SMLC-R2 LMC100AE-SFP
FlexPoint™ 10/100
CUSTOMER
SUPPORT
INFORMATION
Overview and Description:
The FlexPoint 10/100 converts between Fast Ethernet
ber 100Base-Fx and 10Base-T or 100Base-Tx twisted
pair (RJ45 UTP) cabling. It operates in half duplex (HD) or full duplex (FD).
Order toll-free in the U.S.: Call 877-877- BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week; Call 724-746-5500 or fax
724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com E-mail: [email protected]
The following FlexPoint 10/100 models are described here:
Model Fiber Type Distance
LMC100A-SC-R3 1310nm, MM, SC 2km LMC100AE-SC-R3 1310nm, MM, SC 2km LMC100A-SMSC-R3 1310nm, SM, SC 28km LMC100AE-SMSC-R3 1310nm, SM, SC 28km LMC100A-R3 1310nm, MM, ST 2km LMC100AE-R3 1310nm, MM, ST 2km LMC100A-SM-R3 1310nm, SM, ST 28km LMC100AE-SM-R3 1310nm, SM, ST 28km LMC100A-SMSC-LH-R3 1310nm, SM, SC 58km LMC100AE-SMSC-LH-R3 1310nm , SM, SC 58km LMC100A-RJ-R3 1310nm, MM, MTRJ 2km LMC100AE-RJ-R3 1310nm, MM, MTRJ 2km LMC100A-SMSC-XLH-R3 1550nm, SM, SC 85km LMC100AE-SMSC-XLH-R3 1550nm , SM , SC 85k m LMC100A-SMSC-SLH-R3 1550nm , SM, SC 110km LMC100AE-SMSC-SLH-R3 1550nm, SM, SC 110km LMC100A-LC-R2 1310nm, MM, LC 2km LMC100AE-LC-R2 1310nm, MM, LC 2km LMC100A-SMLC-R2 1310nm, SM, LC 28km LMC100AE-SMLC-R2 1310nm, SM, LC 28km LMC100A-SFP SFP SFP LMC100AE-SFP SFP SFP
Installation and Conguration:
Power Adapter Notice:
1. When Using in a stand-alone conguration, this
product is intended to be and must be used only with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.
2. This product should always be used only with the Supplied Power Unit.
Before inserting the Power Adapter, verify
WARNING!
that the power on the unit is appropriate
for your AC line voltage source.
Mounting and Cable Attachment:
The FlexPoint 10/100 can be solo-mounted using a wall-mounting kit, or rack-mounted using a 5-position shelf or a high-density 14-unit FlexPoint Powered Chassis.
Attach the FlexPoint 10/100 UTP via a category 5 cable to a 10Base-T or 100Base-Tx Ethernet device.
Attach the FlexPoint 10/100 ber via cable to a 100Base-Fx
Fast Ethernet device. The FlexPoint transmit (Tx) must attach to the receive side on other device; the receive (Rx) must attach to the transmit.
Switch Settings: “RJ45 Cross-Over” Switch:
When the UTP port is set to Auto-Negotiation, the Auto­Crossover functionality within the product is enabled and the slide switch is disabled. When the UTP port is set to Manual, the slide switch is enabled and functional. When in Manual mode and connecting the UTP port to a hub of switch, set the switch to “Straight-Through” (factory setting). When connecting to a workstation, set it to “Cross-Over.”
“UTP Auto/UTP Manual” Switch:
Setting the switch to “Auto” (factory setting) enables the UTP port to determine the speed and duplex mode automatically. If the connected device cannot provide the proper signal to indicate its own mode of operation, the “Manual” switch should be used. This feature allows connections with devices that do not auto-negotiate properly.
“UTP 10/UTP 100” Switch:
When the “Auto/Manual” switch is in “Manual” position, the “UTP 10/UTP 100” switch determines the speed of operation for the UTP port. When set to “UTP 100” (factory setting), the UTP port will operate at 100 Mbps. When set to “UTP 10” the UTP port will operate at 10 Mbps. Adjust the 10/100 Mbps switch to the speed of the connecting device and check for link status.
“UTP Full Duplex/UTP Half Duplex” Switch:
When the “Auto/Manual” switch is in “Manual” position, the “UTP Full Duplex/UTP Half Duplex” switch determines the duplex operation mode for the UTP port. When set to “Full Duplex” (factory setting), the UTP port will operate in full duplex. When set to “Half Duplex” the UTP port will operate in half duplex. Adjust the half/full­duplex switch to accommodate the connecting device and check for link status.
Half duplex must be used when connecting to a hub. Full duplex should be used when connecting switches or between a switch and a full-duplex workstation.
“Fiber Full Duplex/Fiber Half Duplex” Switch:
Since the IEEE 802.3 standard denes the Ethernet
10Base-FL fiber differently than the Fast Ethernet 100Base-Fx, it should be noted that they are incompatible. The FlexPoint 10/100 supports 100Base-Fx on ly. It ope rate s in a half- or full-duplex mode of operation. This switch
controls the half/full-duplex operation of the ber port.
Half duplex should be used when connecting to a hub
(with a shared/non-switched ber port) or a workstation
that supports only half-duplex. Full duplex can be used when connecting to a switch or a workstation that supports full-duplex operation.
©Copyright 2014. Black Box Corporation. All rights reserved.
1000 Park Drive · Lawrence, PA 15055-1018
724-746-5500 · Fax 724-746-0746
LED Indicators:
LED Color Description
Power: Yellow Power applied UTP Auto: Green Auto-Negotiation enabled UTP FDx: Green Full-Duplex detected UTP Link: Green Link / Data received UTP 10: Yellow 10 Mbps link detected UTP 100: Green 100 Mbps link detected Fiber FDx: Green Full-Duplex selected F/O Link: Green Link / Data received
SPECIFICATIONS:
Protocol: IEEE 802.3  Connectors & Cables:
Twisted Pair UTP: RJ45, Category 5 or higher Fiber: SC, ST, MT-RJ or SFP
Multimode: 50/125, 62.5/125, 100/140µm Single-mode: 9/125µm
Supported Distances: Half-Duplex Full-Duplex
Twisted Pair UTP: 100m/328ft. 100m/328ft.  MM1310nmber: 412m/1,350ft. 2km/1.2mi. SM1310nmber: 412m/1,350ft. 28km/16.8mi. SM1310nmLHber: 412m/1,350ft. 58km/36mi. SM1310nmXLHber:412m/1,350ft. 85km/52.8 mi. SM1310nmSLHber:412m/1,350ft. 110km/68.4 mi.
Dimensions / Weight: W:3.0”xD:4.0”xH:1.0” / 6oz. Power: 9VDC/500mA or 5VDC/750mA Temperature: 0 to 50 degrees C Humidity: 0-90% (non-condensing)
TRADEMARKS USED IN THIS MANUAL
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A
computing device in accordance with the specications in
subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to be cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modications not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits ra­dioélectriques dépassant les limites applicables aux appareils numéirques de las classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua— por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carri­tos o pedelstales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a
personal de servicio calicado.
9. El aparato eléctrico debe ser situado de tal manera que su
posición no interera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra or supercie
similar puede bloquea la ventilación, no se debe colocar
en libreros o gabinetes que impidan el ujo de aire por los oricios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor,
estufas u ostros aparatos (incluyendo amplicadores) que
producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precación debe ser tomada de tal manera que la tierra
sica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos co­locados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos
liquidos no sean derramados sobre la cubierta u oricios
de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro
del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra
un cambio en su desempeño; o E: El aparto ha sido tirado o su cubierta ha sido dañada.
LMC100A-SC-R3, version 2
040-01009-R31B 12/14
Loading...