LMC100A-SC-R3
LMC100AE-SC-R3
LMC100A-SMSC-R3
LMC100AE-SMSC-R3
LMC100A-R3
LMC100AE-R3
LMC100A-SM-R3
LMC100AE-SM-R3
LMC100A-SMSC-LH-R3
LMC100AE-SMSC-LH-R3
LMC100A-SFP
LMC100A-RJ-R3
LMC100AE-RJ-R3
LMC100A-SMSC-XLH-R3
LMC100AE-SMSC-XLH-R3
LMC100A-SMSC-SLH-R3
LMC100AE-SMSC-SLH-R3
LMC100A-LC-R2
LMC100AE-LC-R2
LMC100A-SMLC-R2
LMC100AE-SMLC-R2
LMC100AE-SFP
FlexPoint™ 10/100
CUSTOMER
SUPPORT
INFORMATION
Overview and Description:
The FlexPoint 10/100 converts between Fast Ethernet
ber 100Base-Fx and 10Base-T or 100Base-Tx twisted
pair (RJ45 UTP) cabling. It operates in half duplex (HD)
or full duplex (FD).
Order toll-free in the U.S.: Call 877-877-
BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day,
7 days a week; Call 724-746-5500 or fax
724-746-0746
Mailing address: Black Box Corporation,
1000 Park Drive, Lawrence, PA 15055-1018
The following FlexPoint 10/100 models are described here:
Model Fiber Type Distance
LMC100A-SC-R3 1310nm, MM, SC 2km
LMC100AE-SC-R3 1310nm, MM, SC 2km
LMC100A-SMSC-R3 1310nm, SM, SC 28km
LMC100AE-SMSC-R3 1310nm, SM, SC 28km
LMC100A-R3 1310nm, MM, ST 2km
LMC100AE-R3 1310nm, MM, ST 2km
LMC100A-SM-R3 1310nm, SM, ST 28km
LMC100AE-SM-R3 1310nm, SM, ST 28km
LMC100A-SMSC-LH-R3 1310nm, SM, SC 58km
LMC100AE-SMSC-LH-R3 1310nm , SM, SC 58km
LMC100A-RJ-R3 1310nm, MM, MTRJ 2km
LMC100AE-RJ-R3 1310nm, MM, MTRJ 2km
LMC100A-SMSC-XLH-R3 1550nm, SM, SC 85km
LMC100AE-SMSC-XLH-R3 1550nm , SM , SC 85k m
LMC100A-SMSC-SLH-R3 1550nm , SM, SC 110km
LMC100AE-SMSC-SLH-R3 1550nm, SM, SC 110km
LMC100A-LC-R2 1310nm, MM, LC 2km
LMC100AE-LC-R2 1310nm, MM, LC 2km
LMC100A-SMLC-R2 1310nm, SM, LC 28km
LMC100AE-SMLC-R2 1310nm, SM, LC 28km
LMC100A-SFP SFP SFP
LMC100AE-SFP SFP SFP
Installation and Conguration:
Power Adapter Notice:
1. When Using in a stand-alone conguration, this
product is intended to be and must be used only with a
Listed Direct Plug-In Power Unit marked “Class 2” and
rated at 9VDC, 1 Amp.
2. This product should always be used only with the
Supplied Power Unit.
Before inserting the Power Adapter, verify
WARNING!
that the power on the unit is appropriate
for your AC line voltage source.
Mounting and Cable Attachment:
The FlexPoint 10/100 can be solo-mounted using a
wall-mounting kit, or rack-mounted using a 5-position shelf
or a high-density 14-unit FlexPoint Powered Chassis.
Attach the FlexPoint 10/100 UTP via a category 5 cable
to a 10Base-T or 100Base-Tx Ethernet device.
Attach the FlexPoint 10/100 ber via cable to a 100Base-Fx
Fast Ethernet device. The FlexPoint transmit (Tx) must
attach to the receive side on other device; the receive
(Rx) must attach to the transmit.
Switch Settings:
“RJ45 Cross-Over” Switch:
When the UTP port is set to Auto-Negotiation, the AutoCrossover functionality within the product is enabled and
the slide switch is disabled. When the UTP port is set
to Manual, the slide switch is enabled and functional.
When in Manual mode and connecting the UTP port
to a hub of switch, set the switch to “Straight-Through”
(factory setting). When connecting to a workstation,
set it to “Cross-Over.”
“UTP Auto/UTP Manual” Switch:
Setting the switch to “Auto” (factory setting) enables
the UTP port to determine the speed and duplex mode
automatically. If the connected device cannot provide
the proper signal to indicate its own mode of operation,
the “Manual” switch should be used. This feature allows
connections with devices that do not auto-negotiate
properly.
“UTP 10/UTP 100” Switch:
When the “Auto/Manual” switch is in “Manual” position,
the “UTP 10/UTP 100” switch determines the speed
of operation for the UTP port. When set to “UTP
100” (factory setting), the UTP port will operate at 100
Mbps. When set to “UTP 10” the UTP port will operate at
10 Mbps. Adjust the 10/100 Mbps switch to the speed of
the connecting device and check for link status.
“UTP Full Duplex/UTP Half Duplex” Switch:
When the “Auto/Manual” switch is in “Manual” position,
the “UTP Full Duplex/UTP Half Duplex” switch
determines the duplex operation mode for the UTP port.
When set to “Full Duplex” (factory setting), the UTP port
will operate in full duplex. When set to “Half Duplex” the
UTP port will operate in half duplex. Adjust the half/fullduplex switch to accommodate the connecting device
and check for link status.
Half duplex must be used when connecting to a hub.
Full duplex should be used when connecting switches or
between a switch and a full-duplex workstation.
“Fiber Full Duplex/Fiber Half Duplex” Switch:
Since the IEEE 802.3 standard denes the Ethernet
10Base-FL fiber differently than the Fast Ethernet
100Base-Fx, it should be noted that they are incompatible.
The FlexPoint 10/100 supports 100Base-Fx on ly. It ope rate s
in a half- or full-duplex mode of operation. This switch
controls the half/full-duplex operation of the ber port.
Half duplex should be used when connecting to a hub
(with a shared/non-switched ber port) or a workstation
that supports only half-duplex. Full duplex can be used
when connecting to a switch or a workstation that
supports full-duplex operation.
©Copyright 2014. Black Box Corporation. All rights reserved.
1000 Park Drive · Lawrence, PA 15055-1018
724-746-5500 · Fax 724-746-0746
LED Indicators:
LED Color Description
Power: Yellow Power applied
UTP Auto: Green Auto-Negotiation enabled
UTP FDx: Green Full-Duplex detected
UTP Link: Green Link / Data received
UTP 10: Yellow 10 Mbps link detected
UTP 100: Green 100 Mbps link detected
Fiber FDx: Green Full-Duplex selected
F/O Link: Green Link / Data received
SPECIFICATIONS:
Protocol: IEEE 802.3
Connectors & Cables:
Twisted Pair UTP: RJ45, Category 5 or higher
Fiber: SC, ST, MT-RJ or SFP
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
Supported Distances: Half-Duplex Full-Duplex
Twisted Pair UTP: 100m/328ft. 100m/328ft.
MM1310nmber: 412m/1,350ft. 2km/1.2mi.
SM1310nmber: 412m/1,350ft. 28km/16.8mi.
SM1310nmLHber: 412m/1,350ft. 58km/36mi.
SM1310nmXLHber:412m/1,350ft. 85km/52.8 mi.
SM1310nmSLHber:412m/1,350ft. 110km/68.4 mi.
Dimensions / Weight: W:3.0”xD:4.0”xH:1.0” / 6oz.
Power: 9VDC/500mA or 5VDC/750mA
Temperature: 0 to 50 degrees C
Humidity: 0-90% (non-condensing)
TRADEMARKS USED IN THIS MANUAL
Black Box and the Double Diamond logo are registered trademarks
of BB Technologies, Inc. Any other trademarks mentioned in this
manual are acknowledged to be the property of the trademark
owners.
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used properly, that
is, in strict accordance with the manufacturer’s instructions,
may cause interference to radio communication. It has been
tested and found to comply with the limits for a Class A
computing device in accordance with the specications in
subpart J of Part 15 of FCC rules, which are designed to
provide reasonable protection against such interference when
the equipment is operated in a commercial environment.
Operation of this equipment in a residential area is likely
to be cause interference, in which case the user at his own
expense will be required to take whatever measures may be
necessary to correct the interference.
Changes or modications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
This digital apparatus does not exceed the Class A limits
for radio noise emission from digital apparatus set out
in the Radio Interference Regulation of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numéirques de las classe A prescrites dans le Règlement sur
le brouillage radioélectrique publié par le ministère des
Communications du Canada.
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
1. Todas las instrucciones de seguridad y operación deberán
ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser
guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus
instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—
por ejemplo, cerca de la tina de baño, lavabo, sótano
mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedelstales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo
sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al
equipo eléctrico más allá a lo descrito en las instrucciones
de operación. Todo otro servicio deberá ser referido a
personal de servicio calicado.
9. El aparato eléctrico debe ser situado de tal manera que su
posición no interera su uso. La colocación del aparato
eléctrico sobre una cama, sofá, alfombra or supercie
similar puede bloquea la ventilación, no se debe colocar
en libreros o gabinetes que impidan el ujo de aire por
los oricios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance
de fuentes de calor como radiadores, registros de calor,
estufas u ostros aparatos (incluyendo amplicadores) que
producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de
poder sólo del tipo descrito en el instructivo de operación,
o como se indique en el aparato.
12. Precación debe ser tomada de tal manera que la tierra
sica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal
manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención
a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de
acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada
lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando
el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos
liquidos no sean derramados sobre la cubierta u oricios
de ventilación.
18. Servicio por personal calificado deberá ser provisto
cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro
del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra
un cambio en su desempeño; o
E: El aparto ha sido tirado o su cubierta ha sido dañada.
LMC100A-SC-R3, version 2
040-01009-R31B 12/14