This Web Smart switch provides
sixteen 10-/100-/1000-Mbps ports.
Supports Gigabit speed on all ports.
LGB616A
Customer
Support
Information
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical supp ort 24 hours a day, 7 days a week: Call 724 -746-550 0 or fax
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence,
PA 15055-1018 • Web site: www.blackbox.com • E-mail : info@ blackbox.com
FCC and IC RFI Statements
FEDERAL COMMUNICATIONS COMMISSION and
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
Class B Digital Device. This equipment has been tested and found to comply with
the limits for a Class B computing device pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. However, there is no guarantee that
interference will not occur in a particular installation. This equipment generates,
uses, and can radiate radio frequency energy, and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. If this equipment does cause harmful interference to radio or
telephone reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult an experienced radio/ TV technician for help.
CAUTION:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
To meet FCC requirements, shielded cables and power cords are required to
connect this device to a personal computer or other Class B certified device.
This digital apparatus does not exceed the Class B limits for radio noise emission
from digital apparatus set out in the Radio Interference Regulation of Industry
Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant
les limites applicables aux appareils numériques de classe B prescrites dans le
Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Page 2
724-746-5500 | blackbox.com
LGB 616A
NOM Statement
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de
que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser
referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,
alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios
de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor
como radiadores, registros de calor, estufas u otros aparatos (incluyendo
amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del
tipo descrito en el instructivo de operación, o como se indique en el aparato.
LGB 616A
724-746-5500 | blackbox.com
Page 3
NOM Statement
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen
del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea
usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su
desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
Page 4
724-746-5500 | blackbox.com
LGB 616A
Trademarks Used in this Manual
Trademarks Used in this Manual
Black Box and the Double Diamond logo are registered trademarks of
BB Technologies, Inc.
Internet Explorer is a registered trademark of Microsoft Corporation.
UL is a registered trademark of Underwriters’ Laboratories.
Any other trademarks mentioned in this manual are acknowledged to be
the property of the trademark owners.
Disclaimer
Black Box Network Services shall not be liable for damages of any kind, including,
but not limited to, punitive, consequential or cost of cover damages, resulting
from any errors in the product information or specifications set forth in this
document and Black Box Network Services may revise this document at any time
without notice.
Transmission Media — 10BASE-T CAT3, 4, 5 UTP/STP;
100BASE-TX CAT5 UTP/STP;
1000BASE-T CAT 5E UTP/STP
Connectors — (16) RJ-45, (1) power connector
Indicators — (33) LEDs: Per port: (1) LINK/ACT, (1) 1000M;
Per unit: (1) Power
Power — Internal power supply: Input Voltage: 90–260 VAC, 50-60 Hz;
Input Power/Watts: 20 watts (max.)
Temperature Tolerance — Operating: +32 to +131° F (0 to +55° C);
Storage: -4 to +194° F (-20 to +90° C)
Operating Humidity — 10 to 90% relative humidity (non-condensing)
Size — 1.73"H x 17.32"W x 8.66 D (4.4 x 45 x 22 cm)
Weight — 6.39 lb. (2.9 kg) unit;
6.61 lb. (3 kg) shipping
Page 8
724-746-5500 | blackbox.com
LGB 616A
Chapter 2: Overview
2. Overview
2.1 Introduction
The 16-Port Web Smart Gigabit Ethernet Switch provides 16 10-/100- /1000-Mbps
ports. It is designed for easy installation and enables high performance in an
environment where traffic on the network and the number of users increase
continuously. With the newest Gigabit chipset, this 19" Gigabit Ethernet switch
fully supports the highest speed without any problems, even when running
full-duplex fully loaded.
The switch also provides automatic crossover detection on each port, making it
easy to uplink to another switch without using a crossover cable.
This rackmountable switch is specifically designed for medium to large
workgroups. It provides smooth network migration and makes it easy to increase
network capacity.
2.2 Features
• Supports real-time status (link, speed, duplex) of each port.
• Supports port setting for enable or disable operation (the first port can’t be
disabled).
• Includes port setting for N-Way or force mode operation.
• Features Broadcast Storm Protection.
• Enables Port-basesd VLAN.
• Supports priority queues for QoS.
• Complies with IEEE 802.3 Ethernet, IEEE 802.3u Fast Ethernet, and IEEE 802.3ab
Gigabit Ethernet standards.
• 16 ports autonegotiate speeds of 10, 100, and 1000 Mbps.
• 19" rackmountable.
• Provides non-blocking and non-head of line blocking full wire-speed
forwarding.
• Store-and-forward operation support.
• Supports 9.6 KB jumbo frames.
• Provides 8K MAC addresses.
• Supports broadcast storm filitering.
LGB 616A
724-746-5500 | blackbox.com
Page 9
Chapter 2: Overview
• All ports provide autonegotiation and Auto MDI/MDI-X functions.
• Supports flow control: Backpressure for half-duplex and IEEE 802.3x for
full-duplex mode.
• Smart plug and play.
2.3 What’s Included
Your package should contain the following items. If anything is missing
or damaged, contact Black Box Technical Support at 724-746-5500
or info@blackbox.com.
• (1) 16-Port Web Smart Gigabit Ethernet Switch
• (1) U.S. power cord
• This user’s manual in PDF format on CD-ROM
• (1) rackmount kit: (2) brackets, (8) screws
2.4 Hardware Description
Figures 2-1 and 2-2 show the front and back panels of the 16-Port Web Smart
Gigabit Ethernet Switch. Table 2-1 describes its components.
Page 10
724-746-5500 | blackbox.com
LGB 616A
Chapter 2: Overview
1 2, 3
4
4
Figure 2-1. Front panel.
5 6 7
Figure 2-2. Back panel.
Table 2-1. 16-Port Web Smart Gigabit Ethernet Switch components.
NumberComponentDescription
1(1) Power LEDLights when power to the unit is on.
2(16) 1000 M LEDsLight when a port is operating at 1000 Mbps.
6Power on/off switchSwitches the power to the unit on or off.
7Power receptacle
LGB 616A
724-746-5500 | blackbox.com
Light solid when link is up, blink when data is present, and are off
when there is no link.
Links 90–260-VAC, 50-60-Hz, 20-W internal power supply to
power outlet
Page 11
Chapter 3: Software Description
3. Software Description
This section explains how to set up and manage the switch through the Web user
interface.
3.1 L o gin
First, open the Web browser, and go to 192.168.2.1. The login screen will appear.
Type in the password (default: admin) to pass the authentication, and click on the
Apply button. The following message will appear:
“Password successfully entered.”
Page 12
Figure 3-1.
724-746-5500 | blackbox.com
LGB 616A
Chapter 3: Software Description
3.2 Configuration
3.2.1 System
This page shows system configuration information, as illustrated in Figure 3-3.
LGB 616A
Figure 3-2. System Configuration screen.
724-746-5500 | blackbox.com
Page 13
Chapter 3: Software Description
• MAC Address: Displays the unique hardware address assigned by manufacturer
(default).
• S/W Version: Displays the switch’s firmware version.
• H/ W Version: Displays the switch’s hardware version.
• DHCP Enabled: Click the box to enable DHCP.
• Fallback IP address: Manually assign the IP address that the network is using.
The default IP is 192.168.2.1.
• Fallback Subnet Mask: Assign the subnet mask to the IP address.
• Fallback Gateway: Assign the network gateway for industrial switch. The default
gateway is 0.0.0.0.
• Management VLAN: ID of a configured VLAN (1–4096) through which you can
manage the switch. By default, all ports on the switch are members of VLAN 1.
However, you change the management VLAN, the management station must
be attached to a port belonging to this VLAN.
• Name: Type in the new user name (the default value is ”admin”).
• Password: Type in the new password (the default value is “admin”).
• SNMP Enabled: Enables or disables SNMP on the switch. Supports SNMP version
1 and 2c management clients.
• SNMP Trap Destination: IP address of the trap manager to receive notification
messages from this switch. Traps indicating status changes are issued by the
switch to specified trap managers. You must specify trap managers so that key
events are reported by this switch to your management station.
• SNMP Read Community: A community string that acts like a password and
permits access to the SNMP database on this switch. Authorized management
stations are only able to retrieve MIB objects.
• SNMP Trap Community: Community string sent with the notification operation.
Page 14
724-746-5500 | blackbox.com
LGB 616A
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.