Black Box LEV2525A, LE2425A Software User's Manual

Page 1
CUSTOMER
SUPPORT
MNS-BB
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com
Page 2
LE2425A / LEV2525A Switch
Software User Guide
(MNS-BB)
Page 3
MNS-BB Software User Guide
Preface Use of This Guide
This guide describes how to use the command line interface (CLI) and Web Interface, for LE2425A and LEV2525A Switches.
If you need information on a specific command in the CLI, type the command name after you type the word “help” (help <command> ) or just type <command> [Enter].
If you need further information on Black Box switch technology, refer to the Black Box website at:
http://www.blackbox.com
-I-
Page 4
MNS-BB Software User Guide
FEDERAL COMMUNICATIONS COMMISSION
AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
-II-
Page 5
MNS-BB Software User Guide
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
-III-
Page 6
MNS-BB Software User Guide
18.Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
-IV-
Page 7
MNS-BB Software User Guide
Table of Contents................................................................................................. Page
1.0 GETTING STARTED.......................................................................................................................................1
1.1 Getting Started with Switch Configuration......................................................................................................1
1.2 Software Upgrade............................................................................................................................................ 1
1.3 Recommended Minimal Configuration ........................................................................................................... 1
1.4 Using the Console Setup Screen......................................................................................................................1
1.5 To Recover from a Lost Manager Password:...................................................................................................2
2.0 CONSOLE MANAGEMENT INTERFACE................................................................................................... 3
2.1 Understanding Management Interfaces ........................................................................................................... 3
2.2 Console Port Connection........................................................................................................ ......................... 3
2.3 Advantages of Using the CLI..........................................................................................................................4
2.4 CLI Usage........................................................................................................................................................4
3.0 USING THE COMMAND LINE INTERFACE (CLI)................................................................................... 5
3.1 Accessing the CLI ........................................................................................................................................... 5
3.2 Using the CLI ..................................................................................................................................................5
3.3 Privilege Levels at Logon................................................................................................................................5
3.3.1 Operator Privileges.................................................................................................................................6
3.3.2 Manager Privileges .................................................................................................................................6
3.4 User Management............................................................................................................................................ 6
3.4.1 CLI Commands...........................................................................................................................................6
3.5 Listing Commands and Command Options.....................................................................................................7
3.5.1 Operator Privilege................................................................................................................................... 7
3.5.2 Manager Privilege................................................................................................................................... 7
3.5.3 Type "help" To List Available Commands.............................................................................................7
3.5.4 Displaying CLI "Help" ...........................................................................................................................8
3.5.5 Displaying Help for an Individual Command......................................................................................... 8
3.5.6 Displaying Help for a particular command.............................................................................................8
3.5.7 Displaying Help with all possibilities.....................................................................................................9
4.0 WEB INTERFACE.................................................................................................................. ........................ 10
4.1 Overview ....................................................................................................................................................... 10
4.2 General Features............................................................................................................................................ 10
4.3 Session with the Switch.................................................................................................................................11
4.4 User Management.......................................................................................................................................... 12
4.4.1 To set the passwords............................................................................................................................. 12
4.5 Status Reporting Features.............................................................................................................................. 13
4.5.1 The Device View..................................................................................................................................13
4.5.2 The Port Statistics................................................................................................................................. 14
4.5.3 Port Utilization......................................................................................................................................14
4.5.4 The Event Log ...................................................................................................................................... 15
5.0 CONFIGURING IP ADDRESSING, INTERFACE ACCESS, AND SYSTEM INFORMATION........... 17
5.1 Overview ....................................................................................................................................................... 17
5.2 IP Configuration............................................................................................................................................17
5.2.1 IP Address and Subnet Mask Overview................................................................................................ 17
5.2.2 IP Address and Subnet Mask. ............................................................................................................... 17
5.2.3 Default Gateway Operation. ................................................................................................................. 17
5.2.4 Configuring IP Address, Gateway, DHCP............................................................................................17
5.3 DHCP/Bootp Operation................................................................................................................................. 17
5.3.1 Overview...............................................................................................................................................17
5.3.2 The DHCP/Bootp Process.....................................................................................................................17
5.3.3 Configuring IP Addressing ................................................................................................................... 18
5.3.4 DHCP Operation................................................................................................................................... 18
5.3.5 Bootp Operation.................................................................................................................................... 18
5.3.6 Bootp Database Record Entries ............................................................................................................ 18
5.3.7 Globally Assigned IP Network Addresses............................................................................................19
5.4 A Quick Start.................................................................................................................................................19
5.5 Interface Access: Console/Serial Link, Telnet Features................................................................................ 19
5.5.1 Serial Port (Console)............................................................................................................................. 20
5.5.2 TELNET...............................................................................................................................................20
5.6 Listing the Current System Information........................................................................................................20
5.6.1 List the current system information settings......................................................................................... 20
5.6.2 System Information...............................................................................................................................21
5.6.3 System Contact and Location: ..............................................................................................................21
5.7 Configure the Date and Time.........................................................................................................................21
5.7.1 SNTP.....................................................................................................................................................21
5.7.2 Time Zone............................................................................................................................................. 22
-V-
Page 8
MNS-BB Software User Guide
5.7.3 Zone and Daylight Time Rule...............................................................................................................22
5.8 CLI: Configuration commands...................................................................................................................... 22
5.8.1 To save the configuration......................................................................................................................22
5.8.2 To load or restore the configuration...................................................................................................... 22
5.8.3 To erase the current configuration........................................................................................................23
5.8.4 Summary (Steps)...................................................................................................................................23
5.9 Web: Configuring IP Addressing...................................................................................................................23
5.10 How IP Addressing Affects Switch Operation..............................................................................................23
6.0 SECURITY FEATURES.................................................................................................................................24
6.1 Manager and Operator passwords:.................................................................................................................24
6.2 Console access interface and the CLI............................................................................................................ 24
6.2.1 Manager................................................................................................................................................ 24
6.2.2 Operator................................................................................................................................................ 24
6.3 To use password security:..............................................................................................................................24
6.4 CLI: Setting Manager and Operator Passwords.............................................................................................24
6.4.1 Configuring Manager and Operator Passwords ....................................................................................24
6.5 Access Levels.................................................................................................................. .............................. 24
6.6 Configuring and Monitoring Port Security.................................................................................................... 24
6.6.1 Basic Operation.....................................................................................................................................25
6.6.2 Blocking Unauthorized Traffic.............................................................................................................25
6.6.3 Planning For Port Security.................................................................................................................... 25
6.7 CLI: Port Security Command Options and Operation................................................................................... 25
6.8 Reading Intrusion Alerts and Resetting Alert Flags ...................................................................................... 27
6.8.1 Notice of Security Violations................................................................................................................27
6.8.2 How the Intrusion Log Operates...........................................................................................................27
6.9 Web: Viewing and Configuring Port Security...............................................................................................28
6.10 SSL (Secure Sockets Layer).......................................................................................................................... 28
6.10.1 The SSL Protocol.................................................................................................................................. 28
6.10.2 Ciphers Used with SSL......................................................................................................................... 30
6.10.3 CLI........................................................................................................................................................ 30
7.0 USING AUTHORIZED IP MANAGERS TO PROTECT AGAINST UNAUTHORIZED ACCESS......32
7.1 Authorized IP Manager Features................................................................................................................... 32
7.2 Access Levels.................................................................................................................. .............................. 32
7.2.1 Authorizing Single Stations:................................................................................................................. 32
7.2.2 Authorizing Multiple Stations:..............................................................................................................32
7.3 Overview of IP Mask Operation.................................................................................................................... 32
7.4 CLI: Viewing and Configuring Authorized IP Managers ..............................................................................33
7.5 Building IP Masks.........................................................................................................................................33
7.5.1 Configuring One Station Per Authorized Manager IP Entry.................................................................34
7.5.2 Configuring Multiple Stations Per Authorized Manager IP.................................................................. 34
7.6 Operating and Troubleshooting Notes:.......................................................................................................... 35
7.6.1 Network Security Precautions:..............................................................................................................35
7.6.2 Duplicate IP Addresses:........................................................................................................ ................ 35
7.6.3 Web Proxy Servers: .............................................................................................................................. 35
7.6.4 Global Access.......................................................................................................................................35
7.7 Web: Viewing and Configuring Global Access Information......................................................................... 35
7.7.1 Web: Viewing and Configuring System Information ........................................................................... 35
8.0 SNMP: CONFIGURATION FOR NETWORK MANAGEMENT APPLICATIONS .............................. 36
8.1 Overview ....................................................................................................................................................... 36
8.2 SNMP v1, v2 and v3......................................................................................................................................36
8.3 BitView and HubView .................................................................................................................................. 36
8.4 SNMP Management Features........................................................................................................................ 37
8.5 Configuring for SNMP Access to the Switch................................................................................................ 37
8.6 CLI: Viewing and Configuring Community Names......................................................................................38
8.6.1 Listing Community Names................................................................................................................... 38
8.7 Configuring Community Names and Values................................................................................................. 38
8.7.1 Adding SNMP Communities in the Switch ..........................................................................................38
8.7.2 Adding SNMP Traps in the Switch.......................................................................................................38
8.7.3 Add or Modify system parameters........................................................................................................ 38
8.8 Using the CLI To List Current SNMP Trap Receivers.................................................................................. 39
8.9 SNMP version 3 (SNMPv3)..........................................................................................................................39
8.9.1 Benefits.................................................................................................................................................40
8.9.2 List of Terms.........................................................................................................................................40
8.9.3 Supported MIBs and RFCs...................................................................................................................41
8.9.4 CLI........................................................................................................................................................ 42
-VI-
Page 9
MNS-BB Software User Guide
8.10 RMON........................................................................................................................................................... 47
8.10.1 Adding RMON Communities in the Switch.........................................................................................47
8.11 Web: Viewing and Configuring SNMP Parameters..................................................................................47
9.0 MONITORING AND ANALYZING SWITCH OPERATION ................................................................... 48
9.1 Overview ....................................................................................................................................................... 48
9.2 Port Monitoring (Mirroring) Features............................................................................................................48
9.2.1 CLI: Configuring Port Monitoring........................................................................................................ 48
9.3 Limitation......................................................................................................................................................49
9.4 Web: Viewing Port Monitor status............................................................................................... ................. 49
10.0 OPTIMIZING PORT USAGE........................................................................................................................50
10.1 Overview ....................................................................................................................................................... 50
10.2 CLI: Viewing Port Status and Configuring Port Parameters ......................................................................... 50
10.2.1 Port Status and Configuration Features.................................................................................................50
10.2.2 Port Status and Configuration Commands............................................................................................ 51
10.2.3 Using the CLI to View Port Status........................................................................................................51
10.2.4 Using the CLI to Configure Ports.........................................................................................................52
10.3 Web: Viewing Port Status and Configuring Port Parameters........................................................................53
10.4 Broadcast Storm Protection........................................................................................................................... 53
10.4.1 How does it works ................................................................................................................................ 53
10.4.2 CLI: To Enable/Disable the broadcast Protection.................................................................................53
10.4.3 To set the Threshold value....................................................................................................................53
10.4.4 How to Protect against Broadcast Storms .............................................................................................53
11.0 QOS (QUALITY OF SERVICE)....................................................................................................................55
11.1 Overview ....................................................................................................................................................... 55
11.2 QoS Concepts................................................................................................................................................55
11.3 IP Precedence: Differentiated QoS................................................................................................................ 55
11.4 DiffServ......................................................................................................................................................... 55
11.5 PQ: Priority Queuing..................................................................................................................................... 56
11.6 QoS Management..........................................................................................................................................56
11.7 QoS on Ethernet.............................................................................................................................................57
11.8 CLI.................................................................................................................................................................57
11.8.1 To set the QoS type on the switch.........................................................................................................57
11.8.2 Functions of QoS settings:....................................................................................................................57
11.9 To tag untagged packets. ............................................................................................................................... 59
11.10 Web: Configure QoS.................................................................................................................................60
12.0 IGMP.................................................................................................................................................................60
12.1 Overview ....................................................................................................................................................... 60
12.2 Purpose..........................................................................................................................................................61
12.3 IGMP Operating Features.............................................................................................................................. 61
12.4 Benefit ...........................................................................................................................................................61
12.5 How IGMP Operates.....................................................................................................................................62
12.6 IGMP Data.....................................................................................................................................................62
12.7 Role of the Switch .........................................................................................................................................62
12.8 IP Multicast Filters ........................................................................................................................................ 64
12.9 Reserved Addresses Excluded from IP Multicast (IGMP) Filtering..............................................................64
12.10 IGMP Support...........................................................................................................................................64
12.11 CLI............................................................................................................................................................64
12.11.1 Enable/disable IGMP............................................................................................................................64
12.11.2 Showing IGMP Configuration.............................................................................................................. 65
12.11.3 Showing Snooped Multicast Groups..................................................................................................... 65
12.11.4 Showing Detected Router Ports............................................................................................................ 65
12.11.5 Enable/Disable Immediate Leave Processing...................................................................................... .65
12.11.6 Enable/Disable Switch as Querier.........................................................................................................66
12.12 Setting the Host Membership Query Interval............................................................................................ 66
12.13 Setting the Query Response Interval.........................................................................................................67
12.14 Configure IGMP Port Mode...................................................................................................................... 67
12.14.1 Showing Port Configuration ................................................................................................................. 67
12.15 Web: Configure and View.........................................................................................................................68
13.0 SPANNING TREE PROTOCOL (STP).........................................................................................................69
13.1 STP Features..................................................................................................................................................69
13.2 Feature Default.......................................................................................................................................... 69
13.3 Viewing the Current STP Configuration. ...................................................................................................... 69
13.3.1 Explaining Parameters in Detail ........................................................................................................... 70
13.3.2 Showing STP Configuration by Port.....................................................................................................70
13.4 Enabling or Disabling STP............................................................................................................................ 71
-VII-
Page 10
MNS-BB Software User Guide
13.5 Reconfiguring General STP Operation on the Switch...............................................................................72
13.6 Globally Enabling or Disabling STP.........................................................................................................72
13.7 Changing STP Bridge Parameter Values...................................................................................................74
13.8 Changing STP Port Parameter Values....................................................................................................... 75
13.9 How STP Operates....................................................................................................................................75
13.10 Web: View and Configure STP Parameters..............................................................................................75
14.0 RAPID SPANNING TREE PROTOCOL (RSTP)........................................................................................76
14.1 How Spanning Tree Operates........................................................................................................................76
14.3 RSTP Concepts.............................................................................................................................................. 76
14.4 Spanning Tree Options: RSTP (802.1w) and STP (802.1D) .........................................................................77
14.4.1 RSTP (802.1w) ..................................................................................................................................... 77
14.4.2 STP (802.1D)........................................................................................................................................ 77
14.5 Transitioning from STP to RSTP...................................................................................................................77
14.6 Configuring Rapid Reconfiguration Spanning Tree (RSTP).........................................................................77
14.6.1 Optimizing the RSTP Configuration.....................................................................................................77
14.7 CLI.................................................................................................................................................................78
14.7.1 Main Context Commands ..................................................................................................................... 78
14.7.2 RSTP Context Commands....................................................................................................................78
14.8 Reconfiguring Per-Port Spanning Tree Values.............................................................................................. 80
14.8.1 Per-Port RSTP Parameters Parameter Default Description...................................................................80
15.0 PORT-BASED VIRTUAL LANS (STATIC VLANS)...................................................................................82
15.1 General Use and Operation............................................................................................................................ 82
15.2 VLAN Support and the Default VLAN......................................................................................................... 82
15.3 General Steps for Using VLANs...................................................................................................................82
15.4 CLI: Configuring VLAN Parameters.............................................................................................................83
LE2425A(port-vlan)##save.................................................................................................................................... 83
Saving current configuration..................................................................................................................................83
Configuration saved................................................................................................................................................83
15.4.1 Displaying the Switch’s VLAN Configuration.....................................................................................83
15.4.2 Displaying the Configuration for a Particular VLAN........................................................................... 84
15.5 Creating a New Static VLAN........................................................................................................................ 84
15.5.1 Changing the VLAN Context Level. .................................................................................................... 84
15.6 Effect of VLANs on Other Switch Features.................................................................................................. 85
15.6.1 VLAN Restrictions ............................................................................................................................... 85
15.7 Web: Viewing and Configuring VLAN Parameters...................................................................................... 85
15.7.1 To configure static VLAN port parameters...........................................................................................85
16.0 TAG BASED VLAN ........................................................................................................................................ 86
16.1 Introduction ................................................................................................................................................... 86
16.2 VLAN Tagging Information..........................................................................................................................87
16.3 Rules of Tag Vlan Operation.........................................................................................................................88
16.3.1 Ingress Rules......................................................................................................................................... 88
16.3.2 Egress Rules..........................................................................................................................................88
16.4 CLI.................................................................................................................................................................89
16.5 New CLI........................................................................................................................................................ 90
16.6 Web: View and Configure Tag-Vlan Parameters..........................................................................................91
17.0 GVRP................................................................................................................................................................ 92
17.1 GVRP (GARP VLAN Registration Protocol)................................................................................................92
17.2 General Operation..........................................................................................................................................93
17.3 Per-Port Options for Handling GVRP “Unknown VLANs”..........................................................................95
17.4 Per-Port Options for Dynamic VLAN Advertising and Joining.................................................................... 95
17.4.1 Enabling a Static VLAN for Dynamic Joins......................................................................................... 95
17.4.2 Parameters for Controlling VLAN Propagation Behavior....................................................................95
17.5 GVRP and VLAN Access Control ................................................................................................................ 96
17.6 Port-Leave From a Dynamic VLAN..............................................................................................................96
17.7 Planning for GVRP Operation.......................................................................................................................97
17.8 Configuring GVRP On a Switch....................................................................................................................97
17.9 Enabling and Disabling GVRP on the Switch...............................................................................................97
17.10 Displaying the Static and Dynamic VLANs Active on the Switch...........................................................98
17.11 GVRP Operating Notes.............................................................................................................................98
17.12 Web: View and Configure GVRP Parameters...........................................................................................99
18.0 Link-Loss Learn Feature..............................................................................................................................100
18.1 CLI..........................................................................................................................................................100
18.2 Web: View and Configure Link Loss Learn................................................................................................ 100
19.0 ALARM RELAY SYSTEM..........................................................................................................................101
19.1 CLI...............................................................................................................................................................101
-VIII-
Page 11
MNS-BB Software User Guide
19.2 Web: View and Configure Alarms .............................................................................................................. 102
20.0 SMTP (SIMPLE MAIL TRANSFER PROTOCOL)..................................................................................103
20.1 Email Alert Features....................................................................................................................................103
20.2 CLI...............................................................................................................................................................103
20.3 Web: View and Configure SMTP Relay ............................................................................................. ........ 105
21.0 802.1X - PORT BASED NETWORK ACCESS CONTROL......................................................................106
21.1 Introduction ................................................................................................................................................. 106
21.2 Overview ..................................................................................................................................................... 106
21.3 Protocol Operation....................................................................................................................................... 107
21.4 CLI...............................................................................................................................................................108
21.5 Web: View and Configure 802.1x...............................................................................................................116
22.0 TACACS+ (TERMINAL ACCESS CONTROLLER ACCESS CONTROL SYSTEM) ......................... 117
22.1 Introduction ................................................................................................................................................. 117
22.2 History......................................................................................................................................................... 117
22.3 Overview ..................................................................................................................................................... 117
22.4 LE2425A / LEV2525A TACACS+............................................................................................................. 117
22.5 Packet Encryption........................................................................................................................................ 120
22.6 CLI...............................................................................................................................................................120
22.7 Web: View and Configure 802.1x...............................................................................................................121
23.0 TROUBLESHOOTING................................................................................................................................122
23.1 Overview ..................................................................................................................................................... 122
23.2 Troubleshooting Approaches.......................................................................................................................122
23.3 Console Access Problems............................................................................................................................ 122
23.4 Unusual Network Activity...........................................................................................................................122
23.5 General Problems ........................................................................................................................................ 123
23.5.1 Duplicate IP Addresses.......................................................................................................................123
23.5.2 SNTP or Gateway Problems............................................................................................................... 123
23.6 Using the Event Log To Identify Problem Sources.....................................................................................123
23.7 Web: Viewing the Event Log......................................................................................................................126
23.7.1 Events Severity (Color Scheme)......................................................................................................... 126
23.8 Diagnostic Tools.......................................................................................................................................... 126
23.8.1 Ping Test............................................................................................................................................. 126
23.8.2 CLI: Ping Test.....................................................................................................................................127
23.9 CLI Administrative and Troubleshooting Commands................................................................................. 127
APPENDIX A..............................................................................................................................................................128
Daylight Savings Time on LE2425A and LEV2525A Switches .............................................................................. 128
List of valid country codes to set daylight settings................................................................................................... 128
APPENDIX B .............................................................................................................................................................. 128
How to Upgrade........................................................................................................................................................ 128
Upgrade over the Network........................................................................................................................................ 131
Boot Code Upgrade .................................................................................................................................................. 131
-IX-
Page 12
MNS-BB Software User Guide
1.0 Getting Started
1.1 Getting Started with Switch Configuration
This section is a guide for using the console Switch Setup commands to quickly assign an IP (Internet Protocol) address and subnet mask to the switch. You can also set a Manager password and configure other basic features from Switch Setup commands.
(For Hardware Installation and configuration, please see the user guide for hardware).
1.2 Software Upgrade
If your LE2425A / LEV2525A already has the software then you will get the Login prompt when you boot up the switch, otherwise you will get the Boot prompt and you will have to upgrade the software (For details refer Appendix B)
Below is a screen example of the boot prompt.
1.3 Recommended Minimal Configuration
In the factory default configuration, the switch has no IP (Internet Protocol) address and subnet mask. In this state, it can be managed only through a direct console connection. To manage the switch through in-band (networked) access, you should configure the switch with an IP address and subnet mask compatible with your network. Also, you should change the Manager password to control access privileges from the console. The default password is “manager” for the Manager user and “operator” for the Operator user respectively. Many other features such as optimizing the switch’s performance, enhancing your control of the network traffic, and improving network security can be configured through the switch’s console interface. Once an IP address has been configured on the switch, these features can be accessed more conveniently through an SNMP network management station running a network management program. For a listing of switch features available with and without an IP address, refer to Chapter: “How IP Configuration”.
1.4 Using the Console Setup Screen
The quickest and easiest way to minimally configure the switch for management and password protection in your network is to use the following sequence. Use a direct console connection to the switch, start a console session, and access the Switch Setup screen.
1. Using the method described in the preceding section, connect a terminal device to the switch and it will display the switch console command (CLI) prompt (the default display).
The CLI prompt appears displaying the switch model number:
LE2425A#
OR
LEV2525A#
-1-
Page 13
MNS-BB Software User Guide
Below is an example of the above prompt.
Below is the sequence of activities that must be completed for the network to find your switch.
1. Boot up the switch.
2. Set the Manager Password (optional).
3. Configure the IP Address and enter the IP address that is compatible with your network.
4. Configure the Subnet Mask and enter the subnet mask used for your network.
5. Configure the Default Gateway of your Network.
Syntax: ipconfig [ip=<ipaddress>] [mask=<subnet-mask>] [dgw=<gateway>] Example: ipconfig ip=192.168.1.150 mask=255.255.255.0 dgw=192.168.1.10
6. Save
7. Restart the unit.
Note: Soft reboot given an opportunity to save the configuration prior to shutdown.
LE2425A#reboot
Proceed on rebooting the switch? [ 'Y' or 'N' ]Y Do you wish to save current configuration? [ 'Y' or 'N' ]
The switch is now configured with a Manager Password, IP address, and subnet mask, and can be accessed through the Console, Telnet, Web or an SNMP-based network management tools. Here is some information about the basic fields.
Parameter Default
System Name LE2425A/LEV2525A Optional; System Contact techsupport@blackbox.com Optional; Manager Password manager Recommended; Logon Default CLI The default setting; Time Zone 0 (none) Optional; Community Name (Get) public Default setting recommended; Community Name (Set) private Default setting recommended; Default Gateway blank Optional; IP Address blank Recommended;
Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addresses used in your network. For more information on IP addressing, see the Chapter 5.
1.5 To Recover from a Lost Manager Password:
If you cannot start a console session at the manager level because of a lost Manager password, please contact techsupport@blackbox.com
.
-2-
Page 14
MNS-BB Software User Guide
2.0 Console Management Interface
This chapter describes the following:
Management interfaces for the LE2425A and LEV2525A Switches.
Advantages of using each interface.
2.1 Understanding Management Interfaces
The console interface is accessed through the DB-9 RS232 connector. Attach a VT100 compatible terminal or a PC running a terminal emulation program to the serial port.
USB to serial adapters are also available for laptops or computers that do not have native serial ports
Management interfaces enable you to reconfigure the switch and to monitor switch status and performance. The LE2425A and LEV2525A switches offer the following interfaces:
CLI – A command line interface offering the full set of switch commands through the VT-100 or
equivalent console built into the switch.
Web browser interface --a switch interface offering status information and a subset of switch
commands through a standard web browser (such as Netscape Navigator or Microsoft Internet Explorer)
This manual describes how to use the CLI, Web Interface and how to use these interfaces to configure and monitor the switch.
The MNS software supports a command-line interface (CLI) through the serial port.
Note: CLI is also accessible through Telnet.
The command-line interface enables local or remote unit installation and maintenance. A set of system
commands allows effective monitoring, configuration and debugging of the device.
2.2 Console Port Connection
Attach a VT100 compatible terminal or a PC running a terminal emulation program to the serial port on the switch. Use the null-modem cable.
When attaching to a PC, set terminal emulation type to VT100, specify the port used by your PC (i.e, COM 1~4), and then set communications to 8 data bits, 1 stop bit, no parity, and 38400 bps (for initial configuration). Also be sure to set flow control to ‘none’.
-3-
Page 15
MNS-BB Software User Guide
2.3 Advantages of Using the CLI
LE2425A> Operator Level LE2425A# Manager Level LE2425A## Configuration Level
Prompt = Product + Model For example, LEV2525 prompt would be LEV2525A> for operator level and LEV2525A# for manager level.
Provides access to the complete set of switch configuration, performance, and diagnostic features.
Enables quick management level access of the detailed system configuration to system operators and
2.4 CLI Usage
2.5 Advantages of Using the Web Browser Interface
administrators experienced in command prompt interfaces.
Provides help at each level for determining available options and variables.
To perform specific procedures such as configuring IP addressing or VLAN or any other module.
To monitor and analyze switch operations.
Easy access to the switch from anywhere on the network
Familiar browser interface--locations of window objects consistent with commonly used browsers,
uses mouse clicking for navigation, no terminal setup
Many features have all their fields in one screen so you can view all values at once
More visual cues, using colors, status bars, device icons, and other graphical objects instead of
relying solely on alphanumeric values
Display of acceptable ranges of values available in configuration list boxes
-4-
Page 16
MNS-BB Software User Guide
3.0 Using the Command Line Interface (CLI)
The CLI (Command Line Interface) is a text-based command interface for configuring and monitoring the switch. The CLI gives you access to the switch’s full set of commands while providing password protection.
The switch executes a multi-tasking operating system on its control processor that manages all system activities. This system allows the administrator to query and configure the switch from either an attached terminal or any of its attached network interfaces.
3.1 Accessing the CLI
This section provides information on how to access the console commands and set or enable the advanced configuration features in the switch.
The CLI is accessed through the switch console. You can access the console out-of-band by directly connecting a terminal device to the switch, or in-band by using Telnet either from a terminal device or through the network interface.
3.2 Using the CLI
The CLI offers the following privilege levels to prevent unauthorized access to the switch:
Operator Manager
When you use the CLI mode to make a configuration change, the switch writes the changes to the Running Configuration file in volatile memory. This allows you to test your configuration changes before making them permanent. To make changes permanent, you must use the save command to save them to the Startup Configuration file in non-volatile memory. If you reboot the switch without first using save, all changes made since the last reboot or save (whichever is later) will be lost.
3.3 Privilege Levels at Logon
Privilege levels control the type of access to the CLI. To implement this control, you must set the Manager password (By default, the manager password is “manager”. If passwords are set when you use the CLI to log on to the switch, you will be prompted to enter a user then enter a password.
For example: Example of CLI Login Screen
In the above case, you will enter the CLI at the level corresponding to the user and password combination you provide (operator or manager). Suppose you log onto the CLI at the Manager level, the following prompt will appear:
LE2425A#_
OR
LEV2525A#_
-5-
Page 17
MNS-BB Software User Guide
We strongly recommend that you change both the Manager and the operator password. Note that changing only an Operator password does not prevent access to the Manager level by intruders who have the Manager password.
3.3.1 Operator Privileges
At the Operator level you can examine the current configuration and move between interfaces without being able to change the configuration. A ">" character delimits the Operator-level prompt.
For example:
LE2425A>_ (Example of the Operator prompt.)
3.3.2 Manager Privileges
Manager privileges give you three additional levels of access: Manager, Global Configuration, and Context Configuration. A “#” character delimits any Manager prompt. For example:
LE2425A#_ (Example of the Manager prompt.)
Manager level: Provides all Operator level privileges plus the ability to perform system-level actions.
The prompt for the Manager level contains only the system name and the “#” delimiter, as shown above. To select this level, enter the enable <manager> command at the Operator level prompt and enter the Manager password, when prompted. For example:
LE2425A> enable <Manager> (Enter enable at the Operator prompt.) LE2425A# _ (The Manager prompt.)
Global Configuration level: Provides all Operator and Manager level privileges, and enables you to
make configuration changes to any of the switch’s software features. The prompt for the Global Configuration level includes the system IP, System Date, time etc.
Context Configuration level: Provides all Operator and Manager privileges, and enables you to make configuration changes in a specific context, such as one or more ports or a VLAN. The prompt for the Context Configuration level includes the system name and the selected context.
For example: LE2425A# configure vlan type=port
OR
LE2425A# vlan type=port
LE2425A(port-vlan)##_ (The Configuration Prompt)
3.4 User Management
Using this module you can add, modify and delete user names and passwords. You can add 5 users maximum. Two privilege levels are available; Manager and Operator. Level 1 is meant for OPERATOR and Level 2 for MANAGER. For example, if you want to set up user name for basic monitoring capabilities then use lower number (Level 1).
Note: You can add more then one manager but total limit of users is five (including OPERATORS and MANAGERS).
3.4.1 CLI Commands
To Add User Syntax: add user=<name> level=<number> LE2425A(user)##add user=Raj level=2
Enter User Password :****** Confirm New Password :****** In this example, User ‘Raj’ will be added with Manager privilege.
-6-
Page 18
MNS-BB Software User Guide
To Delete User
Syntax: delete user=<name> LE2425A(user)##delete user=Raj
Confirm User Deletion(Y/N): Y User successfully deleted
To modify Password
Syntax: passwd user=<name> LE2425A(user)## passwd user=Raj
Enter New Password :****** Confirm New Password :****** Password has been modified successfully
To modify the Privilege Level
Syntax: chlevel user=<name> level=<number> LE2425A(user)## chlevel user=Raj level=1 Access Permission Modified In this example, User ‘Raj’ has been modified with Operator privilege.
3.5 Listing Commands and Command Options
At any privilege level you can:
List all of the commands available at that level
List the options for a specific command
Listing Commands Available at Any Privilege Level At a given privilege level you can execute the commands that level offers plus all of the commands available at preceding levels. For example, at the Operator level you can list and execute only the Operator level commands. However, at the Manager level you can list and execute the commands available at both the Operator and Manager levels.
Privilege Level Example of Prompt and Permitted Operations
3.5.1 Operator Privilege
-View status and configuration information.
-Perform connectivity tests.
-Move from the Operator level to the Manager level using the ‘enable’ command.
-Exit from the CLI interface and terminate the console session using the ‘logout’ command.
For a list of available commands, enter ‘help’ at the prompt. For example, to view status and configuration information of the Operator Level use the show command: LE2425A> show <command>
3.5.2 Manager Privilege
At the Manager Level (LE2425A#) prompt you can perform system-level actions such as system control, configuration, monitoring, and diagnostic commands, plus any of the Operator-level
commands. For a list of available commands, enter ‘help’ at the prompt.
At the Configuration (LE2425A##) prompt you can execute configuration commands, plus all Operator and Manager commands. For a list of available commands, enter ‘help’ at the Context Configuration prompt.
3.5.3 Type "help" To List Available Commands.
Typing the ‘help’ command lists the commands you can execute at the current privilege level. For example, typing ‘help’ at the Operator level produces this listing:
-7-
Page 19
MNS-BB Software User Guide
LE2425A> help
Typing ‘help’ at the Manager level produces this listing
LE2425A# help
3.5.4 Displaying CLI "Help"
CLI Help provides four types of context-sensitive information:
Command list with a brief summary of each command’s purpose.
Detailed information on how to use individual commands.
Command line verbosity with possible options.
Command usage of specific commands.
3.5.5 Displaying Help for an Individual Command.
You can display Help for any command that is available at the current context level by typing help then entering enough of the command string to identify the command.
Syntax: help <command string>
For example, to list the Help for the set time command at the Configuration privilege level type: LE2425A# help set time
3.5.6 Displaying Help for a particular command.
You can display the command usage of a specific command by typing the command and pressing enter.
Syntax: <Command Name> <Enter>
-8-
Page 20
MNS-BB Software User Guide
3.5.7 Displaying Help with all possibilities.
You can display Help for all possible commands and options that are available by pressing the <TAB> key.
Syntax: <TAB>
Or <Command string> <TAB> Or <First character of the command> <TAB>
For example, <TAB> will list the available commands in the particular privilege level:
LE2425A > <TAB> clear enable exit help logout ping set show telnet terminal walkmib whoami
LE2425A > s <TAB> set show
LE2425A # set <TAB> bootmode date daylight logsize password serial snmp stp time timeformat timeout timezone vlan
-9-
Page 21
MNS-BB Software User Guide
4.0 Web Interface
4.1 Overview
Optimize your network uptime by using the Alert Log and other diagnostic tools.
Make configuration changes to the switch.
Maintain security by configuring usernames and passwords.
This chapter covers the following:
General features.
System requirements for using the web browser interface.
Starting a web browser interface session.
Tasks for your first web browser interface session.
Creating usernames and passwords in the web browser interface. Getting access to online help for the web browser interface.
Description of the web browser interface:
Overview window and tabs. Port Utilization and Status displays. Event Log and Event types.
4.2 General Features
The LE2425A and LEV2525A switches include these web browser interface features:
Switch Administration:
• System information
• SNMP/SNMPv3
• User Management
• TACACS+
• Access
Web Console: Home Page
-10-
Page 22
MNS-BB Software User Guide
Note: If you want security beyond that achieved with user names and passwords, you can disable access to the web browser interface. This is done by executing ‘allow’ command in ‘access’ module at the Command Prompt. (For more details please refer Chapter 7).
Switch Configuration:
• Ports
Port Setting
Port Security
Port Mirroring
• VLAN
Port Vlan
Tag Vlan
GVRP
• Bridging
Aging
Address Table
ARP Table
• STP/RSTP
Bridge STP/RSTP
Port STP/RSTP
Link Loss Learn
S-Ring (Optional)
• 802.1x
• SMTP
• QoS
• SNTP
• IGMP
• Logs
Event Log
• Statistics
Port statistics
Log statistics
• Software/OS upload (File Management)
TFTP
FTP
• Telnet
• Ping
4.3 Session with the Switch
1. You can start a web browser session using a standalone web browser on a network connection from a PC or UNIX workstation:
• Directly connected to your network
• Connected through remote access to your network
• Compatible with Netscape 4.x onwards and Microsoft Internet Explorer 5.x onwards.
2. Type the IP address (or DNS name) of the switch in the browser Location or Address field and press [Enter].
LE2425A or LEV2525A [Enter] (example of a DNS-type name)
10.11.12.180 [Enter] (example of an IP address)
If you are using a Domain Name Server (DNS), your device may have a name associated with it (for example, LE2425A) that you can type in the Location or Address field instead of the IP address. Using DNS names typically improves browser performance.
Note: See your network administrator for any name associated with the switch.
-11-
Page 23
MNS-BB Software User Guide
4.4 User Management
You may want to create both a username and password to create access security for your switch. There are two levels of access to the interface that can be controlled by setting user names and passwords: Operator: An Operator-level user name and password allows read-only access to most of the web browser interface, but prevents access to the Configuration. Manager: A Manager-level user name and password allows full read/write access to the web browser interface.
To Set the Device Passwords Window
4.4.1 To set the passwords
1. Go to Administration-Æ User Management
2. Click in the appropriate box in the Passwords window and enter user names and passwords. You will be required to repeat the password strings in the confirmation boxes.
3. Click on [OK] to modify the user names and passwords.
Note: Passwords you assign in the web browser interface will overwrite previous passwords assigned in the web browser interface, the Command Prompt, or the switch console. That is, the most recently assigned passwords are the switch’s passwords, regardless of which interface was used to assign the string.
-12-
Page 24
MNS-BB Software User Guide
4.5 Status Reporting Features
4.5.1 The Device View
Example of the Login Window in the Web Browser Interface
The manager and operator passwords are used to control access to all switch interfaces. Once set, you will be prompted to supply the password every time you try to access the switch through any of its interfaces. The password you enter determines the capability you have during that session:
¾ Entering the manager password gives you full read/write capabilities ¾ Entering the operator password gives you read and limited write capabilities.
Using the User Names
If you also set user names in the web browser interface screen, you must supply the correct user name and access type for web browser interface access.
If you loose a Password, contact techsupport@blackbox.com
Online Help for the LE2425A / LEV2525A Web Browser Interface
Online Help is available for the web browser interface. You can use it by clicking on the Help button in the navigation bar of the web browser interface screens. Context-sensitive help is provided with in the Help.
Support URL
This is the site that the switch accesses when you click on the Support button on the web browser interface. The default URL is:
http://www.blackbox.xom
which is the World Wide Web site for Blackbox networking products. On that page you can get to support information regarding your switch, including white papers, operating system (OS) updates, and more.
Note If you do not have an active connection to the World Wide Web, then online support for the web browser interface will not be available.
Browser elements covered in this section include:
The Device View (Logical)
Port utilization and status
The Event log
The Status bar
The Device view is the logical view of the front panel of the switch. The following figure
identifies
the various parts of the screen.
-13-
Page 25
MNS-BB Software User Guide
4.5.2 The Port Statistics
The Port Utilization and Status displays show an overview of the status of the switch and the amount of network activity on each port. The following figure shows a sample reading of the Port Utilization and Port Status.
4.5.3 Port Utilization
The Port Utilization bar graphs show the network traffic on the port with a breakdown of the packet types that have been detected (Multicast packets, Frames with CRC, Oversized Frames, and Jabber Frames). The Legend identifies traffic types.
-14-
Page 26
MNS-BB Software User Guide
The Port Status indicators show a symbol for each port that indicates the general status of the port. There are four possible states: Port Connected – the port is enabled and is properly connected to an active network device, shows green in color. Port Not Connected – the port is enabled but is not connected to an active network device. A cable may not be connected to the port, or the device at the other end may be powered off or inoperable, or the cable or connected device could be faulty. Port Disabled – the port has been configured as disabled through the web browser interface, the switch console, or SNMP network management.
Port Enabled – the port is enabled by default. (Read chapter “Monitoring and Analyzing Switch Operation” for more information.)
4.5.4 The Event Log
The web browser interface Event Log, shows a list of network occurrences, or alerts, that were detected by the switch. Typical alerts are Cold start, indicating that switch has been restarted, and Link up :port 6, indicating that port number 6 is being enabled.
-15-
Page 27
MNS-BB Software User Guide
Each alert has the following fields of information:
Date/Time – The date and time the event was received by the web browser interface. This value is
shown in the format: DD-MM-YY HH:MM:SS AM/PM, for example, 01-08-2001 7:58:44 AM.
Severity – It show the severity level of the event. There are five severity levels: Informational,
Activity, Critical, Fatal and Debug.
Description – A short narrative statement that describes the event. For example, “Vlan with this
Vlan name already exists”.
Sorting the Alert Log Entries
The alerts are sorted, by default, by the Date/Time field with the most recent alert listed at the top of the list. The second most recent alert is displayed below the top alert and so on. If alerts occurred at the same time, the simultaneous alerts are sorted by order in which they appear in the MIB. The alert field that is being used to sort the alert log is indicated by which column heading is in bold.
.
See chapter “Troubleshooting” for more information on Event Log.
-16-
Page 28
MNS-BB Software User Guide
5.0 Configuring IP Addressing, Interface Access, and System Information
5.1 Overview
This chapter describes the switch configuration features available in the CLI and web browser interface. For help on how to use these interfaces, refer to: _ Chapter 3, “Using the Command Line Interface (CLI)” _ Chapter 4, Using the Secure Web Browser Interface”
Why Configure IP Addressing? In its factory default configuration, the switch operates as a multi port learning bridge with network connectivity provided by the ports on the switch. However, to enable specific management access and control through your network, you will need IP addressing Why Configure Interface Access and System Information? The interface access features in the switch operate properly by default. However, you can modify or disable access features to suit your particular needs. Similarly, you can choose to leave the system information parameters at their default settings. However, using these features can help you to more easily manage a group of devices across your network.
5.2 IP Configuration
5.2.1 IP Address and Subnet Mask Overview.
Configuring the switch with an IP address expands your ability to manage the switch and use its features. To configure IP addressing, use the CLI to manually conf igure the initial IP values.
5.2.2 IP Address and Subnet Mask.
By default, the switch is set to manual IP addressing. To arrange the manual IP addressing, use the CLI to configure the initial IP values. If you want to configure the IP automatically then enable the DHCP/Bootp server that has been set correctly with information to support the switch, and it will auto configure the IP. (Refer to “DHCP/Bootp Operation” for information on setting up automatic configuration from a server.). For information on how IP addressing affects switch performance, refer to “How IP Addressing Affects Switch Operation”.
5.2.3 Default Gateway Operation.
The default gateway is required for tasks such as reaching off-subnet destinations or forwarding traffic across multiple VLANs. The gateway value is the IP address of the next-hop gateway node for the switch which is used if the requested destination address is not on a local subnet/VLAN. If the switch does not have a manually-configured default gateway and DHCP/Bootp is configured, then the default gateway value provided by the DHCP or Bootp server will be used. If the switch has a manually configured default gateway, then the switch uses this gateway.
5.2.4 Configuring IP Address, Gateway, DHCP
Do one of the following: _ To set the bootmode parameter to Manual and then manually enter the IP address and subnet mask values you want for the switch. _ To use DHCP or Bootp, use the “set bootmode” command to ensure that the bootmode parameter is set to DHCP or Bootp (this enables the DHCP/Bootp), then refer to “DHCP/Bootp Operation”.
Syntax: set bootmode=<dhcp|bootp|manual> LE2425A# set bootmode=dhcp
Save and restart the switch. It will fetch an IP address from the DHCP Server.
5.3 DHCP/Bootp Operation
5.3.1 Overview
DHCP/Bootp is used to provide configuration data from a DHCP or Bootp server to the switch. This data can be the IP address, subnet mask, and default gateway. With either DHCP or Bootp, the servers must be configured prior to the switch being connected to the network.
5.3.2 The DHCP/Bootp Process
Whenever the IP Config parameter in the switch is configured to DHCP/Bootp , or when the switch is rebooted with this configuration then follow the steps below:
-17-
Page 29
MNS-BB Software User Guide
5.3.3 Configuring IP Addressing
1.DHCP/Bootp requests are automatically broadcast on the local network. (The switch sends one type of request to which either a DHCP or Bootp server can respond.)
2. When a DHCP or Bootp server receives the request, it replies with a previously configured IP address and subnet mask for the switch. The switch also receives an IP Gateway address if the server has been configured to provide one. In the case of Bootp, the server must first be configured with an entry that has the MAC address of the switch. To determine the switch’s MAC address, use CLI command: LE2425A#show mac MAC Address: 00:20:06:25:00:11
Note If you manually configure a gateway on the switch, it will ignore any gateway address received via DHCP or Bootp.
If the switch is initially configured for DHCP/Bootp operation, or if it is rebooted with this configuration, it immediately begins sending request packets on the network. If the switch does not receive a reply to its DHCP/Bootp requests, it continues to periodically send request packets, but with decreasing frequency. Thus, if a DHCP or Bootp server is not available or accessible to the switch when DHCP/Bootp is first configured, the switch may not immediately receive the desired configuration. After verifying that the server has become accessible to the switch, reboot the switch to re-start the process immediately.
5.3.4 DHCP Operation
A significant difference between a DHCP configuration and a Bootp configuration is that an IP address assignment from a DHCP server is automatic. Depending on how the DHCP server is configured, the switch may receive an IP address that is temporarily leased from the DHCP. Periodically the switch may be required to renew its lease of the IP configuration. Thus, the IP addressing provided by the server may be different each time the switch reboots or renews its configuration from the server. However, you can fix the address assignment for the switch by doing either of the following: _ Configure the server to issue an “infinite” lease. _ Using the switch’s MAC address as an identifier, configure the server with a “Reservation” so that it will always assign the same IP address to the switch. For more information on either of these procedures, refer to the documentation provided with the DHCP server. For DHCP operation:
The entire scope of DHCP configuration has been updated on the appropriate DHCP server.
The necessary network connections are in place
A DHCP server is accessible from the switch
After you reconfigure or reboot the switch while in a network providing DHCP/Bootp service with DHCP/Bootp enabled, the switch does the following: _ Receives an IP address, _ Subnet mask, and _ Gateway IP address (if configured in the server)
5.3.5 Bootp Operation
When a Bootp server receives a request, it searches its Bootp database for a record entry that matches the MAC address in the Bootp request from the switch. If a match is found, the configuration data in the associated database record is returned to the switch. For many UNIX systems, the Bootp database is contained in the /etc/bootptab file. In contrast to DHCP operation, Bootp configurations are always the same for a specific receiving device. That is, the Bootp server replies to a request with a configuration previously stored in the server and designated for the requesting device.
5.3.6 Bootp Database Record Entries
A minimal entry in the Bootp table file /etc/bootptab to update an IP address and subnet mask to the switch would be similar to this entry:
-18-
Page 30
MNS-BB Software User Guide
LE2425switch:\ ht=ether:\ ha=002006250065:\ ip=192.168.1.88:\ sm=255.255.255.0:\ gw=192.168.1.1:\ hn:\ vm=rfc1048
where:
LE2425switch is a user-defined symbolic name to help you find the correct section of the bootptab file. If you have multiple switches that will be using Bootp to get their IP configuration, you should use a unique symbolic name for each switch. ht is the “hardware type”. For the LE2425A and LEV2525A Managed Switches, set this to ether (for Ethernet). This tag must precede the ha tag. ha is the “hardware address”. Use the switch’s 12-digit MAC address. ip is the IP address to be assigned to the switch. sm is the subnet mask of the subnet in which the switch is installed.
Note: The above Bootp table entry is a sample that will work for the LE2425A and LEV2525A Switches when the appropriate addresses and file names are used.
Network Preparations for Configuring DHCP/Bootp
In its default configuration, the switch is configured for manual IP operation. DHCP/BootP can be enable.
Syntax: set bootmode=<dhcp|bootp|manual>
However, the DHCP/Bootp feature will not acquire IP addressing for the switch unless the following tasks have already been completed:
For Bootp operation:
A Bootp database record has already been entered into an appropriate Bootp server.
The necessary network connections are in place
The Bootp server is accessible from the switch
5.3.7 Globally Assigned IP Network Addresses
If you intend to connect your network to other networks that use globally administered IP addresses, Blackbox strongly recommends that you use IP addresses that have a network address assigned to you. There is a formal process for assigning unique IP addresses to networks worldwide. For more information please contact your internet service provider (ISP).
5.4 A Quick Start
If you just want to give the switch an IP address so that it can communicate on your network, or if you are not using VLANs, Blackbox recommends that you use the CLI commands to quickly configure IP addressing. To do so, do one of the following:
Enter the following command at the CLI Manager level prompt. LE2425A# ipconfig ip = <ipaddress> mask = <subnet-mask> dgw= <default-gateway>
Syntax: show ipconfig
LE2425A# show ipconfig IP Address : 192.168.1.25 Subnet Mask : 255.255.255.0 Default Gateway : 192.168.1.10
Note: In the factory-default configuration there is no IP addressing assigned to the switch.
5.5 Interface Access: Console/Serial Link, Telnet Features
In most cases, the default configuration is acceptable for standard operation. Note Basic switch security is through passwords. You can gain additional security using IP authorized managers. However if unauthorized access is gained to the switch through in-band
-19-
Page 31
MNS-BB Software User Guide
(Telnet), then you can disallow in-band access (as described in this section) and install the switch in a locked environment.
Feature Default
Inactivity Time 10 Minutes Terminal Type VT-100 Baud Rate 38400 Flow Control None
5.5.1 Serial Port (Console)
User can change the serial (Console) parameters viz baud rate, data, parity, stop and flow control with in MNS-BB.
Syntax: set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>] [stop=<1|1.5|2>] [flowctrl=<none|xonxoff]
To see the current settings, Syntax: show serial LE2425A#show serial Baud Rate: 38400 Data : 8 Parity : No Parity Stop : 1
Flow Control : None
5.5.2 TELNET
The Telnet protocol is often thought of simply as a provider for remote logins to computer via the Internet. This was its original purpose although it can be used for many other purposes. It is best understood in the context of a user with a local computer accessing the local telnet program (known as the client program) to run a login session on a remote computer where his communication needs are handled by a telnet server program running on the remote computer. It should be emphasized that the telnet server can pass on the data it has received from the client to many other types of processes including a remote login server.
A user can telnet a remote host (Computer or switch) from the LE2425A or LEV2525A.
syntax: telnet <ipaddress> [port=<port number>]
E.g. telnet 192.168.1.1 [port is optional]. The default port is 23.
We also have the Telnet Client on the LE2425A and LEV2525A. Users can telnet the LE2425A and LEV2525A from the host (Computer or switch) remotely. In other words users can manage the switch remotely.
: (i) we have to have an IP configuration on the switch before starting the telnet
Note
session. (ii) Once the Telnet session starts, the serial connection will be inactive. (iii) In the default configuration, inbound and outbound Telnet access is enabled.
To disable or enable Telnet access: Syntax: telnet <enable/disable> LE2425A (access) ## telnet disable
Disabling Access to Telnet
LE2425A (access) ## telnet enable Enabling Access to Telnet
5.6 Listing the Current System Information.
5.6.1 List the current system information settings.
Syntax: show setup This example shows the switch’s default console configuration.
-20-
Page 32
MNS-BB Software User Guide
Version : LE2425A build 1.3 Feb 17 2005 15:22:18 MAC Address : 00:20:06:25:11:40 IP Address : 192.168.1.106 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.1.1 CLI Mode : Manager System Name : LE2425A System Description : 25 Port Modular Ethernet Switch System Contact : support@blackbox.com System Location : Lawrence, PA System ObjectId : 1.3.6.1.4.1.6878.12.6
and,
Syntax: show sysconfig Syntax: show console
5.6.2 System Information
Configuring system information is optional, but recommended. System Name: Using a unique name helps you to identify individual devices in stacking
environments and when using SNMPc, HP Open View or any other NMS software for Hubs & Switches. (For more details see chapter SNMP).
5.6.3 System Contact and Location:
This information is helpful for identifying the person administratively responsible for the switch and for identifying the locations of individual switches.
LE2425A#snmp LE2425A(snmp)## Syntax: setvar [sysname|syscontact|syslocation]=<string> LE2425A(snmp)##setvar syslocation= Lawrence System variable(s) set successfully
(For more details see chapter SNMP).
5.7 Configure the Date and Time
The switch uses the date command to configure the date. Note that the CLI uses either a 12 or 24­hour clock scheme; that is, hour (hh) values from 1 p.m. to midnight are input either as 1 or 13. You can set the format with the help of the set time command.
Syntax: set date year=<2000-2036> month=<1-12> day=<1-31>
For example, to set the switch to 3:45 p.m. on October 1, 2001 in California USA input “GMT – 08:00”: LE2425A# set timezone GMT=[+ or -] hour=<0-14> min=<0-59> LE2425A# set date year=<2001-2035> month=<1-12> day=<1-31>
Note: Executing reboot resets the time and date to their default startup values.
5.7.1 SNTP
Simple Network Time Protocol The SNTP protocol is used to allow network access to accurate clocks and other sources of time base
information that is an adaptation of the Network Time Protocol (NTP) used to synchronize device clocks in the Internet.
The SNTP client of the LE2425A and LEV2525A has the ability to set the SNTP server IP address. The SNTP client synchronizes the time and date with the SNTP server.
CLI Commands
LE2425A# sntp LE2425A(sntp)##
Syntax: setsntp server = <ipaddress> timeout = <1-10> retry = <1-3>
E.g., LE2425A(sntp)## setsntp server = 204.65.129.201 timeout = 3 retry = 3
-21-
Page 33
MNS-BB Software User Guide
User can also set the frequency for synchronization of time from SNTP Server. Syntax: sync [hour=<0-24>] [min=<0-59>]
Once the IP address of SNTP assigned then enable the SNTP service. LE2425A(sntp)## sntp enable| SNTP is enabled. Note: If you do not have SNTP Server on your local network then you can use any public SNTP/NTP Server. Here are a few known public SNTP/NTP Servers.
worf.ijs.si - 193.2.4.2 time.ijs.si - 193.2.4.6 time.nrc.ca - 132.246.168.164 ntp0.usno.navy.mil - 192.5.41.40
5.7.2 Time Zone
The number of minutes your time zone location is to the West (+) or East (-) of Coordinated Universal Time (formerly GMT). The default 0 means no time zone is configured.
5.7.3 Zone and Daylight Time Rule.
These commands:
Set the time zone you want to use
Define the daylight time rule for keeping the correct time when
daylight-saving-time shifts occur.
Syntax: set timezone GMT=[+ or -] hour=<0-14> min=<0-59> set timeformat format=<12|24> set daylight country=< country name> Note: For more details please read Appendix A.
5.8 CLI: Configuration commands
The LE2425A and LEV2525A have the following CLI commands available for configuration management.
Saveconf
Loadconf
Kill config (Hidden Command)
Note: These commands are available in ‘Manager’ privilege only.
5.8.1 To save the configuration
You can save the configuration as a binary file on the local console or FTP or TFTP Server using the ‘saveconf’ command
Syntax: saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] LE2425A# saveconf mode=serial file=LEconfig Note: File name is a user defined name.
5.8.2 To load or restore the configuration
You can load the configuration from the location you have saved the configuration e.g., the local console, FTP or TFTP Server using ‘loadconf’ command.
Syntax: loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<Name>] LE2425A# loadconf mode=serial file=LEconfig
-22-
Page 34
MNS-BB Software User Guide
5.8.3 To erase the current configuration Syntax: kill config Note: This is a hidden command. It erases the current configuration and loads the factory default
configuration. It is highly recommended to use this command only if you really need to erase the current configuration.
LE2425A# kill config
Warning: Before erasing the current configuration using the ‘kill config’ command it is suggested that you save the current configuration using the ‘saveconf’ command. The ‘kill config’ command will erase the current configuration and load the default con figuration values. The ‘kill config’ command will not erase or change any saved configuration settings in memory.
The ‘Kill config’ command asks for confirmation. If you are sure press ‘Y’, otherwise press ‘N’.
Do you want to erase the configuration? [ 'Y' or 'N']
If you press ‘Y’, it displays a confirmation message
Successfully erased configuration...Please reboot.
Note: Please restart the switch to get a default configuration. kill config’ will not erase the current configuration until or unless you restart the switch.
5.8.4 Summary (Steps)
1. Save the current configuration on local console or FTP or TFTP Server. Command: saveconf
2. Erase current configuration. Command: kill config
3. Hard boot the switch to get the factory default configuration.
5.9 Web: Configuring IP Addressing
You can use the web browser interface to access IP addressing only if the switch already has an IP address that is reachable through your network.
1. Click on the [Administration] on left bar.
2. Click on [System].
3. If you need further information on using the web browser interface, click on [Help] to access the web-based help available for the LE2425A and LEV2525A Switches.
5.10 How IP Addressing Affects Switch Operation
Without an IP address and subnet mask compatible with your network, the switch can be managed only through a direct terminal device connection to the Console RS-232 port. You can use direct­connect console access to take advantage of features that do not depend on IP addressing. However, to realize the full performance capabilities LE2425A and LEV2525A networking offers through the switch, configure the switch with an IP address and subnet mask compatible with your network. The following table lists the general features available only with a network- compatible IP address configured.
Features Not Available Without an IP Address
Telnet access to CLI
MNS-BB Web Browser Interface
SNMP Network Management
SNTP Server Configuration
TFTP and FTP download of configurations and Software updates
Ping test
-23-
Page 35
MNS-BB Software User Guide
6.0 Security Features
6.1 Manager and Operator passwords:
You can gain access and privileges for the command line through either the console port or through the network by using Telnet . The features described in this chapter enhance security controls against unauthorized access through the network.
6.2 Console access interface and the CLI.
There are two levels of console access: Manager and Operator. For security, you can set a password on each of these levels.
6.2.1 Manager
This level allows access to all console interface areas. Please change the default Manager Password to limit access of unauthorized people to the configuration area of the console interface.
6.2.2 Operator
This level allows access to the Status, Event Log, and CLI levels but does not allow Configuration capabilities. On the Operator level, the Configuration Context, Download Application, and Reboot Switch option are not accessible.
6.3 To use password security:
1. Set a Manager password (and an Operator password, if applicable for your system).
2. Exit from the current console session. A Manager password will now be needed for full access to the console. Assuming that both a Manager password and an Operator password have been set, the level of access to the console interface will be determined by which password is entered in response to the prompt. The manager and operator passwords control access to the CLI.
Note: Passwords are case-sensitive.
6.4 CLI: Setting Manager and Operator Passwords
6.4.1 Configuring Manager and Operator Passwords
This procedure prompts you to enter a password twice to help verify that you have correctly entered the desired characters.
Syntax: set password
LE2425A# set password Enter old password:******** Enter new password:********* Confirm password :********* Password changed successfully Note: Password must be 4-10 characters (For more details, please refer chapter 3)
6.5 Access Levels
For each authorized user, the Manager and Operator have specific access levels (For Details, Please see Chapter 2).
6.6 Configuring and Monitoring Port Security
The port security feature can be used to block input to an Ethernet, Fast Ethernet, or Gigabit Ethernet port when the MAC (Media Control Address) of the station attempting to access the port is different from any of the MAC addresses specified for that port. In the event of security violation, the port can be configured to go into the disable mode or drop mode. The drop mode allows the user to configure the port to remain enabled during a security violation and drop only packets that are coming in from insecure hosts.
Network security hinges on the ability to allow or deny access to network resources. The access
-24-
Page 36
MNS-BB Software User Guide
control aspect of secure network services involves allowing or disallowing traffic between a private network and an external network (such as the Internet) based on information contained in packets, such as the IP address, MAC address, or content. One such technology is Access Control Lists (ACL). An ACL is a packet filtering mechanism that reads a packet and allows it to pass or discards it according to criteria set up by the system administrator LE2425A and LEV2525A switches support the source MAC filtration in Port Security module.
6.6.1 Basic Operation
Default Port Security Operation: The default port security setting for each port is off. That is, any
device can access a port without causing a security reaction.
Intruder Protection: A port that detects an “intruder” blocks the intruding device or drops the packets from transmitting to the network through that port.
General Operation for Port Security: On a per-port basis, you can set up security measures to block unauthorized devices and send notice of security violations. Once you have configured port security, you can then monitor the network for security violations through the Event Log. For any port, you can configure the following:
Authorized (MAC) Addresses: Specify devices (MAC addresses) that are allowed to send inbound traffic through the port. This feature:
• Closes the port to inbound traffic from any unauthorized devices that are connected to the port.
• Provides the option for sending information to the log of a detected attempted security violation to a network management station and disables the port.
Note: There is a limitation of 200 MAC addresses per port and 500 MAC addresses per Switch for Port Security.
6.6.2 Blocking Unauthorized Traffic
Unless you configure the switch to disable a port or drop the packets when a security violation is detected, the switch security only blocks unauthorized traffic without disabling the port. This feature enables you to apply the security configuration to ports on which hubs, switches, or other devices are connected and maintain security while also maintaining network access to authorized users.
6.6.3 Planning For Port Security
1. Plan your port security configuration and monitoring according to the following: a. On which ports do you want to configure port security? b. Which devices (MAC addresses) are authorized on each port?
c. For each port, what security actions do you want? (The switch automatically blocks intruder detected on that port from transmitting to the network.) The switch can be configured to
(i) Send intrusion alarms to the event Log and (ii) Optionally disable the port on which the intrusion was detected. d. How do you want to learn of the security violation attempts the switch detects? You can use the Event Log (through the CLI show log command) to see the intrusion.
2. Use the CLI commands to configure port security operating and address controls.
6.7 CLI: Port Security Command Options and Operation
Configuring Port Security
Syntax: configure port-security LE2425A# configure port-security OR port-security <enter> It will take you to the configuration mode to configure the port security.
LE2425A(port-security)##
Allow an Authorized Device to a Port.
-25-
Page 37
MNS-BB Software User Guide
There are two ways to add authorized MAC addresses: Manual (CLI: allow) or Automatic (CLI: learn).
Syntax: allow mac=<address|list|range> port=<num|list|range> To simply add a device (MAC address) to a port’s existing Authorized Addresses list, enter the port number with the mac-address parameter and the device’s MAC address.
LE2425A(port-security)## allow mac=00:c1:00:7f:ec: 00 00:60:b0:88:9e:00 port=18 In above example, two authorized devices are allowed for port number 18.
Ports can also learn the MAC addresses with the help of the following command. Syntax: learn port=<number-list> <enable|disable> LE2425A(port-security)## learn port=17,18 enable In the above example, Port 17 and 18 start learn the MAC addresses of connected devices. Note: 1. Only when the ACTION is set to NONE will the MAC ADDRESS be learned
2. Maximum 200 MAC addresses can be learned per port.
To enable and disable Port Security
Syntax: ps <enable|disable> LE2425A(port-security)## ps enable This command enables the port security and switch is now ready to learn the MAC addresses.
To See the Authorized Devices
Syntax: show port-security LE2425A# show port-security port=18 After executing the above command, the security configuration for port 18 would be: Port :18 Action :Disable Signal :Log Learn Mode :Enable MAC_Addresses: 00:c1:00:7f:ec:00 00:60:b0:88:9e:00
To see all the Ports
Syntax: show port-security
LE2425A# show port-security Status: Port-security Disabled Port Action Signal Learn_Mode Mac_Address 1 None None Disable None 2 None None Disable None 3 None None Disable None 4 None None Disable None 5 None None Disable None 6 None None Disable None 7 None None Disable None 8 None None Disable None 9 None None Disable None 10 None None Disable None 11 None None Disable None 12 None None Disable None 13 None None Disable None 14 None None Disable None 15 None None Disable None 16 None None Disable None 17 Drop Log Enable None 18 Drop Log Enable00:c1:00:7f:ec:00 00:60:b0:88:9e:00 19 Drop Log Enable None 20 Drop Log Enable None 21 Drop Log Enable None
-26-
Page 38
MNS-BB Software User Guide
22 Drop Log Enable None 23 Disable Log Enable 00:e0:29:6c:a4:fd 24 Drop Log Enable None 25 None None Disable None
Removing a Device from the “Authorized” List for a Port.
This command option removes unwanted devices (MAC addresses) from the Authorized Addresses list. (An Authorized Address list is available for each port where Learn Mode is set to “Static” To use the CLI to remove a device that is no longer authorized: Example: suppose port 18 is configured as shown below and you want to remove 00c100-123456 from the Authorized Address list: LE2425A# show port-security port=18 Port :18 Action :Disable Signal :Log Learn Mode :Disable MAC_Addresses: 00:c1:00:7f:ec:00 00:60:b0:88:9e:00 The following command serves this purpose by removing 00:c1:00:7f:ec:00
LE2425A(port-security)## remove mac=00:c1:00:7f:ec:00 port=18 The above command sequence results in the following configuration for port 18: LE2425A# show port-security port=18 Port :18 Action :Disable Signal :Log Learn Mode :Disable MAC_Addresses:00:60:b0:88:9e:00
To Set Action Type of secured port
Syntax: action port=<num|list|range> type=<none|disable|drop> User can set the action type (none, disable or drop) for un-authorized devices for secured ports. LE2425A(port-security)##action port=11 drop
Port security Action type set to Drop on selected port(s)
To set signal type of secured port
Syntax: signal port=<num|list|range> <none|log|trap|logandtrap> User can set the ytpe of signal (Log, Trap or Both) for un-authorized devices for secured ports. LE2425A(port-security)##signal port=11 logandtrap
Port security Signal type set to Log and Trap on selected port(s)
6.8 Reading Intrusion Alerts and Resetting Alert Flags
6.8.1 Notice of Security Violations
When the switch detects an intrusion on a port, it sets an “alert flag” for that port and makes the intrusion information available as described below. When a security violation occurs on a port configured for Port Security, the switch logs the intruder activity in the event log.
– The show log command displays the Intrusion Log and the Event Log with different options.
6.8.2 How the Intrusion Log Operates
When the switch detects an intrusion attempt on a port, it enters a reco rd of this event in the event Log. The event Log lists the most recently detected security violation attempts. This gives you a history of past intrusion attempts also.
Example:
S Date Time Log Description
-27-
Page 39
MNS-BB Software User Guide
A 01-01-2001 12:05:52 AM PS:INTRUDER 00:e0:29:6c:a4:fd@port19, packet dropped A 01-01-2001 12:07:04 AM PS:INTRUDER 00:50:0f:02:33:b6@port17, packet dropped A 01-01-2001 12:07:16 AM PS:INTRUDER 00:e0:29:2a:f0:3a@port17, packet dropped A 01-01-2001 12:07:16 AM PS:INTRUDER 00:01:03:e2:27:89@port17, packet dropped A 01-01-2001 12:07:30 AM PS:INTRUDER 00:e0:29:08:d7:e9@port17, packet dropped A 01-01-2001 12:07:32 AM PS:INTRUDER 00:10:dc:6e:52:95@port17, packet dropped A 01-01-2001 12:07:34 AM PS:INTRUDER 00:e0:29:08:d6:43@port17, packet dropped
The above is an example of Multiple Intrusion Log Entries for the Same Port
The log shows the most recent intrusion at the top of the listing. Instead, if the log is filled when the switch detects a new intrusion, the oldest entry is dropped off the listing and the newest entry appears at the top of the listing.
6.8.3 CLI: Checking for Intrusions, Listing Intrusion Alerts The following commands display port status including, whether there are intrusion alerts for any port(s), a list of the intrusions, and which specific ports had the intrusions.
LE2425A# show log
S Date Time Log Description
A 01-01-2001 12:05:18 AM PS:INTRUDER 00:50:0f:02:33:b6@port17, packet dropped A 01-01-2001 12:05:26 AM PS:INTRUDER 00:02:b3:1d:05:dc@port17, packet dropped A 01-01-2001 12:05:36 AM PS:INTRUDER 00:01:03:e2:27:89@port17, packet dropped A 01-01-2001 12:05:40 AM PS:INTRUDER 00:e0:29:11:1b:af@port17, packet dropped A 01-01-2001 12:05:44 AM PS:INTRUDER 00:02:b3:64:d8:cf@port17, packet dropped A 01-01-2001 12:05:44 AM PS:INTRUDER 00:e0:29:09:5d:be@port17, packet dropped A 01-01-2001 12:05:48 AM PS:INTRUDER 00:02:b3:08:d2:22@port17, packet dropped A 01-01-2001 12:05:48 AM PS:INTRUDER 00:e0:29:2a:f0:3a@port17, packet dropped A 01-01-2001 12:05:56 AM PS:INTRUDER 00:10:dc:40:57:95@port17, packet dropped A 01-01-2001 12:06:02 AM PS:port 18 disabled, INTRUDER 00:e0:29:2a:f1:bd
This log shows the intrusion at the port 17 and 18. You can always clear the log with clear command.
LE2425A# clear log It clears the complete log.
You can also clear the specific part of the Log. Syntax: clear log <informational|debug|activity|critical|fatal> LE2425A# clear log activity It clears the ‘activity’ log only.
6.9 Web: Viewing and Configuring Port Security
In the web browser interface:
1. Click on the [Configuration]
2. Click on [Port].
3. Click on [Security].
4. Click on [Status] to enable it.
5. Click on any specific port to set ‘Signal’, ‘Action’ and ‘Learn’ status.
6. After you make the desired changes, click on [OK] button.
7. Click [Save] to save the configuration.
6.10 SSL (Secure Sockets Layer)
LE2425A and LEV2525A switches provide remote management through Telnet and Web in clear text. In other words, Telnet protocol negotiations as well as HTML over HTTP protocol negotiations that are sent to and from the LE2425A and LEV2525A switches are not encrypted and are vulnerable to attacks from malicious sources.
The MNS-BB Security Package (Rel2.7.1 onwards) resolved this issue. This package provides Secure Sockets Layer (SSL) and Transport Layer Security (TLS) that enables the current embedded web server to be able to handle secure HTTP (HTTPS).
6.10.1 The SSL Protocol
-28-
Page 40
MNS-BB Software User Guide
SSL protocol is a security protocol that provides communications privacy over the Internet. The protocol allows client/server applications to communicate in a way that is designed to prevent eavesdropping, tampering, or message forgery.
The primary goal of the SSL Protocol is to provide privacy and reliability between two communicating applications. SSL provides a library for extending the current embedded web server by providing encryption/decryption processes and thus upgrading to HTTPS.
The Transmission Control Protocol/Internet Protocol (TCP/IP) governs the transport and routing of data over the Internet. Other protocols, such as the HyperText Transport Protocol (HTTP), LADP or Internet Messaging Access Protocol (IMAP), run "on top of" TCP/IP in the sense that they all use TCP/IP to support typical application tasks such as displaying web pages or running email servers.
SSL runs above TCP/IP and below high-level application protocols
The SSL protocol runs above TCP/IP and below higher-level protocols such as HTTP or IMAP. It uses TCP/IP on behalf of the higher-level protocols, and in the process allows an SSL-enabled server to authenticate itself to an SSL-enabled client, allowing the client to authenticate itself to the server, and allowing both machines to establish an encrypted connection.
These capabilities address fundamental concerns about communication over the Internet and other TCP/IP networks:
SSL server authentication allo ws a user to confirm a server's identity. SSL-enabled client
software can use standard techniques of public-key cryptography to check that a server's certificate and public ID are valid and have been issued by a certificate authority (CA) listed in the client's list of trusted CAs.
SSL client authentication allo ws a server to confirm a user's identity. Using the same
techniques as those used for server authentication, SSL-enabled server software can check that a client's certificate and public ID are valid and have been issued by a certificate authority (CA) listed in the server's list of trusted CAs.
An encrypted SSL connection requires all information sent between a client and a server to
be encrypted by the sending software and decrypted by the receiving software, thus providing a high degree of confid entiality. Confidentiality is important for both parties to any private transaction. In addition, all data sent over an encrypted SSL connection is protected with a mechanism for detecting tampering--that is, for automatically determining whether the data has been altered in transit.
The SSL protocol includes two sub-protocols: the SSL record protocol and the SSL handshake protocol. The SSL record protocol defines the format used to transmit data. The SSL handshake protocol involves using the SSL record protocol to exchange a series of messages between an SSL­enabled server and an SSL-enabled client when they first establish an SSL connection. This exchange of messages is designed to facilitate the following actions:
Authenticate the server to the client.
Allow the client and server to select the cryptographic algorithms, or ciphers, that they both
support.
Optionally authenticate the client to the server.
-29-
Page 41
MNS-BB Software User Guide
Use public-key encryption techniques to generate shared secrets.
Establish an encrypted SSL connection.
6.10.2 Ciphers Used with SSL
The SSL protocol supports the use of a variety of different cryptographic algorithms, or ciphers, for use in operations such as authenticating the server and client to each other, transmitting certificates, and establishing session keys. Clients and servers may support different cipher suites, or sets of ciphers, depending on factors such as the version of SSL they support, company policies regarding acceptable encryption strength, and government restrictions on export of SSL-enabled software. Among its other functions, the SSL handshake protocol determines how the server and client negotiate which cipher suites they will use to authenticate each other, to transmit certificates, and to establish session keys. The cipher suite descriptions that follow refer to these algorithms:
DES. Data Encryption Standard, an encryption algorithm used by the U.S. Government.
DSA. Digital Signature Algorithm, part of the digital authentication stand ard used by the
U.S. Government.
KEA. Key Exchange Algorithm, an algorithm used for key exchange by the U.S.
Government.
MD2, MD4 and MD5. Message Digest algorithm.
RC2, RC4 and RC5. Rivest encryption ciphers developed for RSA Data Security.
RSA. A public-key algorithm for both encryption and authentication. RSA key exchange. A
SHA-1. Secure Hash Algorithm, a hash function used by the U.S. Government.
Blowfish
Key-exchange algorithms like RSA key exchange govern the way in which the server and client determine the symmetric keys they will both use during an SSL session. The most commonly used SSL cipher suites use RSA key exchange.
The SSL 2.0 and SSL 3.0 (TLS 1.0) protocols support overlapping sets of cipher suites. Administrators can enable or disable any of the supported cipher suites for both clients and servers. When a particular client and server exchange information during the SSL handshake, they identify the strongest enabled cipher suites they have in common and use those for the SSL session.
However, since 40-bit ciphers can be broken relatively quickly, administrators who are concerned about eavesdropping and whose user communities can legally use stronger ciphers should disable the 40-bit ciphers.
6.10.3 CLI
Global Features
Users are able to enable/disable SSL extensions for Web Management. When turned on,
When Web Management is disabled, SSL is also disabled regardless of whether SSL
Note: SSL security can be disabled or enabled through Access module. By default it is enabled.
LE2425A#access
key-exchange algorithm for SSL based on the RSA algorithm.
browser clients will have to communicate with the switch through HTTPS protocol instead of HTTP protocol.
function is enabled or disabled.
-30-
Page 42
MNS-BB Software User Guide
LE2425A(access)##
Syntax: ssl <enable|disable>
LE2425A(access)## ssl enable SSL is enabled.
To see the status of SSL and Web
Syntax: show ssl LE2425A# show ssl SSL/TLS is enabled.
Syntax: show web LE2425A# show web HTTP is enabled. Current HTTP type is secure.
If SSL is disabled, LE2425A#show web HTTP is enabled. Current HTTP type is unsecured.
-31-
Page 43
MNS-BB Software User Guide
7.0 Using Authorized IP Managers to Protect Against Unauthorized Access
7.1 Authorized IP Manager Features
This feature enables you to enhance security on the switch by using IP addresses to authorize which stations (PCs or workstations) can access the switch. Thus, having the correct passwords is not sufficient for accessing the switch through the network unless the station attempting access is also included in the switch’s Authorized IP Managers configuration. Access controls cover:
Telnet (CLI ) SNMP (network management) Web (Web Interface) Up to 25 authorized manager addresses, where each address applies to either a single management station or a group of stations
Note This feature does not protect access to the switch through a modem or direct connection to the Console (RS-232) port. Also, if the IP address assigned to an authorized management station is configured in another station, the other station can gain management access to the switch even though a duplicate IP address condition exists. For these reasons, you should enhance your network’s security by keeping physical access to the switch restricted to authorized personnel, using the password features built into the switch, and preventing unauthorized access to data on your management stations.
7.2 Access Levels
For each authorized manager address, you can configure either of these access levels:
7.2.1 Authorizing Single Stations:
The table entry authorizes a single management station to have IP access to the switch. To use this method, just enter the IP address of an authorized management station in the Authorized Manager IP column, and leave the IP Mask set to 255.255.255.255. This is the easiest way to use the Authorized Managers feature.
7.2.2 Authorizing Multiple Stations:
The table entry uses the IP Mask to authorize access to the switch from a defined group of stations. This is useful if you want to easily authorize several stations to have access to the switch without typing in an entry for every station. All stations in the group are defined by the one Authorized Manager IP table entry and its associated IP mask and will have the same access level.
To configure the switch for authorized manager access, enter the appropriate Authorized Manager IP value and specify an IP Mask. The IP Mask determines how the Authorized Manager IP value is used for allowing or denying access to the switch by a management station.
7.3 Overview of IP Mask Operation
The default IP Mask is 255.255.255.255 and allows switch access only to a station having an IP address that is identical to the Authorized Manager IP parameter value. (“255” in an octet of the mask means that only the exact value in the corresponding octet of the Authorized Manager IP parameter is allowed in the IP address of an authorized management station.) However, you can alter the mask and the Authorized Manager IP parameter to specify ranges of authorized IP addresses. For example, a mask of 255.255.255.0 and any value for the Authorized Manager IP parameter allows a range of 0 through 255 in the 4 addresses for IP management access (excluding 0 for the network and 255 for broadcasts). A mask of
255.255.255.252 uses the 4 addresses (252,253,254,and 255) for management station access.
Note The IP Mask is a method for recognizing whether a given IP address is authorized for management access to the switch. This mask serves a different purpose than IP subnet masks and is applied in a different manner.
th
octet of the authorized IP address. This enables a block of up to 254 IP
th
octet of a given Authorized Manager IP address to authorize four IP
-32-
Page 44
MNS-BB Software User Guide
7.4 CLI: Viewing and Configuring Authorized IP Managers
Listing the Switch’s Current Authorized IP Manager(s) Use the show ip-access command to list IP stations authorized to access the switch. For example:
Example of the Show IP Authorized-Manager Display The above example shows an Authorized IP Manager List that allows stations to access the switch for a specific service.
LE2425A#access <enter> LE2425A(access)##
Configuring IP Authorized Managers for the Switch
Syntax: allow ip=<ipaddress> mask=<netmask> service=<name|list>
To Authorize Manager Access. This command authorizes access for any station having an IP address of 10.28.227.0 through 10.28.227.255for Telnet service: LE2425A(access)## allow ip=10.28.227.101 mask = 255.255.255.0 service=telnet
Similarly, the next command authorizes access for any station having an IP address of 10.28.227.101 through 103 for snmp service: LE2425A(access)##allow ip=10.28.227.101 mask=255.255.255.252 service=snmp,telnet
You can deny a service(s) for a specific IP/Net mask also as shown below. Syntax: deny ip=<ipaddress> mask=<netmask> service=<name|list> LE2425A(access)## deny ip=10.28.227.101 mask = 255.255.255.0 service=telnet
To Edit an Existing Access Entry. To change the mask or access level for an existing entry, use the entry’s IP address and enter the new value(s).
LE2425A(access)## deny ip=10.28.227.101 mask = 255.255.255.0 service=web The above command replaces the existing mask and access level for IP address 10.28.227.101 with
255.255.255.0 and web denied service.
LE2425A(access)## allow ip=10.28.227.101 mask = 255.255.0.0 service=web The above command replaces the existing mask and access level for IP address 10.28.227.101 with
255.255.0.0 and allowed web service.
User can also remove a specific entry or all the entries using ‘remove’ comma nd Syntax: remove ip=<ipaddress> mask=<netmask> LE2425A(access)##remove ip=10.28.227.101 mask=255.255.255.0
Access entry removed
To remove all the entries
Syntax: removeall LE2425A(access)##removeall Do you want to remove all Access Entries? [ 'Y' or 'N'] Y All access entries are removed
7.5 Building IP Masks
The IP Mask parameter controls how the switch uses an Authorized Manager IP value to recognize the IP addresses of authorized manager stations on your network.
-33-
Page 45
MNS-BB Software User Guide
7.5.1 Configuring One Station Per Authorized Manager IP Entry
This is the easiest way to apply a mask. If you have ten or fewer management and/or operator stations, you can configure them quickly by simply adding the address of each to the Authorized Manager IP list with 255.255.255.255 for the corresponding mask. For example, if you configure an IP address of 10.28.227.125 with an IP mask of 255.255.255.255, only a station having an IP address of 10.28.227.125 has management access to the switch.
IP Mask
Authorized Manager IP
Table: Analysis of IP Mask for Single-Station Entries
7.5.2 Configuring Multiple Stations Per Authorized Manager IP
The mask determines whether the IP address of a station on the network meets the criteria you specify. That is, for a given Authorized Manager entry, the switch applies the IP mask to the IP address you specify to determine a range of authorized IP addresses for management access. As described above, that range can be as small as one IP address (if 255 is set for all octets in the mask), or can include multiple IP addresses (if one or more octets in the mask are set to less than 255).
If a bit in an octet of the mask is “on” (set to 1), then the corresponding bit in the IP address of a potentially authorized station must match the same bit in the IP address you entered in the Au thorized Manager IP list. Conversely, if a bit in an octet of the mask is “off” (set to 0), then the corresponding bit in the IP address of a potentially authorized station on the network does not have to match its counterpart in the IP address you entered in the Authorized Manager IP list. Thus, in the example shown above, a “255” in an IP Mask octet (all bits in the octet are “on”) means only one value is allowed for that octet—the value you specify in the corresponding octet of the Authorized Manager IP list. A “0” (all bits in the octet are “off”) means that any value from 0 to 255 is allowed in the corresponding octet in the IP address of an authorized station. You can also specify a series of values that are a subset of the 0-255 range by using a value that is greater than 0, but less than 255.
IP Mask
Authorized Manager IP
IP Mask
Authorized Manager IP
st
Octet 2nd Octet 3rd Octet 4th Octet
1
255 255 255 255
10 28 227 125
st
Octet 2nd Octet 3rd Octet 4th Octet
1
255 255 0 255
10 33 248 1
255 238 0 255
10 247 100 195
Device Access
The “255” in each octet of the mask specifies that only the exact value in that octet of the corresponding IP address is allowed. This mask allows management access only to a station having an IP address of 10.28.227.125.
Device Access
This combination specifies an authorized IP address of 10.33.xxx.1. It could be applied, for example, to a sub netted network where each subnet is defined by the third octet and includes a management station defined by the value of “1” in the fourth octet of the station’s IP address.
Allows 230, 231, 246, and 247 in the 2nd octet, and 194, 195, 198, 199 in the 4th octet.
Table: Analysis of IP Mask for Multiple-Station Entries
NOTE: User can set maximum 25 rules (Allow/Deny). 26
-34-
th
rule will overwrite the first rule.
Page 46
MNS-BB Software User Guide
7.6 Operating and Troubleshooting Notes:
7.6.1 Network Security Precautions:
You can enhance your network’s security by keeping physical access to the switch restricted to authorized personnel, using the password features built into the switch, and preventing unauthorized access to data on your management stations.
Modem and Direct Console Access: Configuring authorized IP manager does not protect against access to the switch through a modem or direct Console (RS-232) port connection.
7.6.2 Duplicate IP Addresses: If the IP address configured in an authorized management station is also configured in another station, the other station can gain management access to the switch even though a duplicate IP address condition exists.
7.6.3 Web Proxy Servers: If you use the web browser interface to access the switch from an authorized IP manager station, it is recommended that you avoid the use of a web proxy server in the path between the station and the switch. This is because switch access through a web proxy server requires that you first add the web proxy server to the Authorized Manager IP list. This reduces security by opening switch access to anyone who uses the web proxy server. The following two options outline how to eliminate a web proxy server from the path between a station and the switch:
Even if you need proxy server access enabled in order to use other applications, you can still eliminate proxy service for web access to the switch. To do so, add the IP address or DNS name of the switch to the non-proxy, or “Exceptions” list in the web browser interface you are using on the authorized station. (e.g. in Microsoft Explorer go to tools, internet options, connections, lan settings, use a proxy server check, and advanced and enter it there). If you don’t need proxy server access at all on the authorized station, then just disable the proxy server feature in the station’s web browser interface.
7.6.4 Global Access
User can authorize the services globally. Here is the list of commands. snmp <enable|disable> dhcp <enable|disable> telnet <enable|disable> web <enable|disable> ssl <enable|disable>
For example, LE2425A(access)##snmp disable It disables the SNMP Access to everyone.
7.7 Web: Viewing and Configuring Global Access Information
In the web browser interface:
1. Click on the [Administration]
2. Click on [Access Ctrl].
4. Click on [Add] button.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
7.7.1 Web: Viewing and Configuring System Information
In the web browser interface:
1. Click on the [Administration]
2. Click on [System].
4. Click on [Modify] button.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
-35-
Page 47
MNS-BB Software User Guide
8.0 SNMP: Configuration for Network Management Applications
This chapter includes:
An overview of SNMP management for the switch.
SNMPv1, v2 and v3 support.
Bitview and Hubview through SNMPc.
Configuring the LE2425A and LEV2525A switches for:
• SNMP management
• SNMP Communities
• Traps Configuration
Information on advanced management through RMON
To implement SNMP management, you must configure the switch with an appropriate IP address.
8.1 Overview
You can manage the switch via SNMP from a network management station. For this purpose, Blackbox recommends the SNMPc, an easy-to-install and use network management
platform that runs on Windows based PC’s. It uses the SNMP and RMON agents statistical sampling software that is included in the switch to provide powerful, but easy-to-use traffic monitoring and network activity analysis tools.
8.2 SNMP v1, v2 and v3
LE2425A and LEV2525A switches support all three versions of SNMP viz SNMP v1, v2 and v3. User can switch between version 1 and version 3. (For details, please read section: SNMPv3)
Note: SNMPv3 supports all three versions.
8.3 BitView and HubView
The BitView and HubView can be seen through SNMPc (Management PC Software).
LE2425A and LEV2525A’s that have BitView and HubView definitions can be managed graphically. BitView displays a bitmap image that matches the faceplate of the device, whereas HubView is a more generic view that shows the layout of the device, but always uses the same picture elements. BitView is functionally similar to HubView, but displays a more realistic image of supported devices. Generally, all the LEDs and other graphical elements available on the device front panel can be displayed with BitView. As with HubView, you can select a device slot or port, and then a menu to operate on the selected item.
LE2425A: Bitview
-36-
Page 48
MNS-BB Software User Guide
LEV2525A : Bitview
8.4 SNMP Management Features
SNMP management features on the switch include: SNMP version 1
Security via configuration of SNMP communities Event reporting via SNMP Managing the switch with an SNMP network management tool Supported Standard MIBs include:
• SNMP MIB-II (RFC 1213)
• Bridge MIB (RFC 1493) ifGeneralGroup, ifRcvAddressGroup, ifStackGroup
• RMON MIB (RFC 1757)
• RMON: groups 1, 2, 3, and 9 (Statistics, Events, Alarms, and History)
• Version 1 traps (Warm Start, Cold Start, Link Up, Link Down, Authentication Failure, Rising
Alarm,
Falling Alarm)
• SNMPv3 RFCs (Please see SNMPv3 section for details)
Blackbox Proprietary MIB
8.5 Configuring for SNMP Access to the Switch
SNMP access requires an IP address and subnet mask configured on the switch. In other words, Network stacks should be configured with an IP address and subnet mask. Once an IP address has been configured, we can follow the same steps as configuring the CLI (see CLI section 6.5) to configure the SNMP Access.
To authenticate the SNMP Manager station, you need to add the IP Address of the Manager station.
This is a security feature of LE2425A and LEV2525A Switches to authenticate the SNMP
console station.
Go to SNMP configuration mode. (i.e., LE2425A(SNMP)##) LE2425A# snmp <enter> LE2425A(SNMP)##
Syntax: mgrip <add|delete> ip=<ipaddress>
Note: If SNMP console is not added to the LE2425A and LEV2525A switch, then user will not be
able to access the
SNMP agent.
-37-
Page 49
MNS-BB Software User Guide
To configure and add the appropriate traps please see the CLI section of this chapter.
8.6 CLI: Viewing and Configuring Community Names
8.6.1 Listing Community Names
This command lists the data for currently configured SNMP community names. Syntax: show snmp
LE2425A# show snmp
This example lists the data for all communities in a switch; that is, both the default "public" community name and another community named "private". The configured community values are
SNMP CONFIGURATION INFORMATION
-------------------------------------------------------­ SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : enabled SNMP Access Status : enabled SNMP MANAGERS INFO
----------------------------------
SNMP TRAP STATIONS INFO
---------------------------------------­SNMP Manager and Traps are not yet configured.
8.7 Configuring Community Names and Values
If you do not specify restricted or unrestricted for the read/write MIB access, the switch automatically restricts the community to read access for the MIB.
8.7.1 Adding SNMP Communities in the Switch
The following SNMP command add new SNMP communities:
Syntax: community [write=<string>] [read=<string>] [trap=<string>]
LE2425A(snmp)## community write=”private” read=”public” trap=”netman”
8.7.2 Adding SNMP Traps in the Switch
The following SNMP command adds a new SNMP Trap:
Syntax: traps <add|delete> type=<Snmp|Rmon|Snmp,Rmon|Enterprise|Snmp,Enterprise|Rmon, Enterprise|All> ip=<ipaddress>
LE2425A(snmp)## traps add type=all ip=192.168.1.2
SNMP traps allow SNMP management programs (E.g., Castle Rock SNMPc and HP Openview) to have alerts on the SNMP station when defined events occur.
8.7.3 Add or Modify system parameters
The following command to add or modify the system Name, System Contact or System Location.
Syntax: setvar [sysname|syscontact|syslocation]=<string> LE2425A(snmp)## setvar sysname=LE2425A LE2425A(snmp)## setvar syscontact=techsupport@blackbox.com
-38-
Page 50
MNS-BB Software User Guide
8.8 Using the CLI To List Current SNMP Trap Receivers
This command lists the currently configured trap receivers along with the current SNMP community name data.
Syntax: show snmp In the next example, the show snmp command shows that the switch has been previously configured to send SNMP traps to management stations belonging to the “public” and “private” communities.
LE2425A(snmp)## show snmp
SNMP CONFIGURATION INFORMATION
-----------------------------­ SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : enabled SNMP Access Status : enabled
SNMP MANAGERS INFO
-----------------­ IP Address = 192.168.1.21
SNMP TRAP STATIONS INFO
----------------------­ IP Address = 192.168.1.21 Trap Type = All
8.9 SNMP version 3 (SNMPv3)
Simple Network Management Protocol Version 3 (SNMPv3) is an interoperable standards-based protocol for network management. SNMPv3 provides secure access to devices by a combination of authenticating and encrypting packets over the network. The security features provided in SNMPv3 are:
Message integrity---Ensuring that a packet has not been tampered with in-transit.
Authentication---Determining the message is from a valid source.
Encryption---Scrambling the contents of a packet prevent it from being seen by an unauthorized
source.
SNMPv3 provides for both security models and security levels. A security model is an authentication strategy that is set up for a user and the group in which the user resides. A security level is the permitted level of security within a security model. A combination of a security model and a security level will determine which security mechanism is employed when handling an SNMP packet. Three security models are available: SNMPv1, SNMPv2c, and SNMPv3. Table below identify what the combinations of security models and levels mean:
Table: SNMP Security Models and Levels
Mode
Level Authentication Encryptio
l
v1 noAuthNoPri
v
v2c noAuthNoPri
v
v3 noAuthNoPri Username No Uses a username match for authentication.
Community String
Community String
What Happens
n
No Uses a community string match for
authentication.
No Uses a community string match for
authentication.
-39-
Page 51
MNS-BB Software User Guide
v
v3 authNoPriv MD5 No Provides authentication based on the
HMAC-MD5 or HMAC-SHA algorithms.
v3 authPriv MD5 DES Provides authentication based on the
HMAC-MD5 or HMAC-SHA algorithms. Provides DES 56-bit encryption in addition to authentication based on the CBC-DES (DES-56) stand
Note the following about SNMPv3 objects:
Each user belongs to a group.
A group defines the access policy for a set of users.
An access policy is what SNMP objects can be accessed for reading, and writing.
A group determines the list of notifications its users can receive.
A group also defines the security model and security level for its users.
8.9.1 Benefits
Data can be collected securely from SNMP devices without fear of the data being tampered with or
corrupted.
Confidential information, for example, SNMP Set command packets that change a router's
configuration, can be encrypted to prevent its contents from being exposed on the network.
8.9.2 List of Terms authentication---The process of ensuring message integrity and protection against message replays.
It includes both data integrity and data origin authentication.
authoritative SNMP engine---One of the SNMP copies involved in network communication designated to be the allowed SNMP engine to protect against message replay, delay, and redirection. The security keys used for authenticating and encrypting SNMPv3 packets are generated as a function of the authoritative SNMP engine's engine ID and user passwords. When an SNMP message expects a response (for example, get exact, get next, set request), the receiver of these messages is authoritative. When an SNMP message does not expect a response, the sender is authoritative.
community string---A text string used to authenticate messages between a management station and an SNMP v1/v2c engine.
data integrity---A condition or state of data in which a message packet has not been altered or destroyed in an unauthorized manner.
data origin authentication---The ability to verify the identity of a user on whose behalf the message is supposedly sent. This ability protects users against both message capture and replay by a different SNMP engine, and against packets received or sent to a particular user that use an incorrect password or security level.
encryption---A method of hiding data from an unauthorized user by scrambling the contents of an SNMP packet.
group---A set of users belonging to a particular security model. A group defines the access rights for all the users belonging to it. Access rights define what SNMP objects can be read, written to, or created. In addition, the group defines what notifications a user is allowed to receive.
notification host---An SNMP entity to which notifications (traps and informs) are to be sent.
notify view---A view name (not to exceed 64 characters) for each group that defines the list of
notifications that can be sent to each user in the group.
-40-
Page 52
MNS-BB Software User Guide
privacy---An encrypted state of the contents of an SNMP packet where they are prevented from being disclosed on a network. Encryption is performed with an algorithm called CBC-DES (DES-56).
read view---A view name (not to exceed 64 characters) for each group that defines the list of object identifiers (OIDs) that are accessible for reading by users belonging to the group. security level---A type of security algorithm performed on each SNMP packet. The three levels are: noauth, auth, and priv. noauth authenticates a packet by a string match of the user name. auth authenticates a packet by using either the HMAC MD5 algorithms. priv authenticates a packet by using either the HMAC MD5 algorithms and encrypts the packet using th e CBC-DES (DES-56) algorithm.
security model---The security strategy used by the SNMP agent. Currently, MNS-BB supports three security models: SNMPv1, SNMPv2c, and SNMPv3.
Simple Network Management Protocol (SNMP)---A network management protocol that provides a means to monitor and control network devices, and to manage configurations, statistics collection, performance, and security.
Simple Network Management Protocol Version 2c (SNMPv2c)---The second version of SNMP, it supports centralized and distributed network management strategies, and includes improvements in the Structure of Management Information (SMI), protocol operations, management architecture, and security.
SNMP engine---A copy of SNMP that can either reside on the local or remote device.
SNMP group---A collection of SNMP users that belong to a common SNMP list that defines an
access policy, in which object identification numbers (OIDs) are both read-accessible and write­accessible. Users belonging to a particular SNMP group inherit all of these attributes defined by the group.
SNMP user---A person for which an SNMP management operation is performed. For informs, the user is the person on a remote SNMP engine who receives the informs.
SNMP view---A mapping between SNMP objects and the access rights available for those objects. An object can have different access rights in each view. Access rights indicate whether the object is accessible by either a community string or a user.
write view---A view name (not to exceed 64 characters) for each group that defines the list of object identifiers (OIDs) that are able to be created or modified by users of the group.
8.9.3 Supported MIBs and RFCs
This feature supports the following RFCs: RFC 1901-1908 – SNMPv2 RFC 2271-2275 – SNMPv3
RFC 1901, Introduction to Community-Based SNMPv2. SNMPv2 Working Group.
RFC 1902, Structure of Management Information for Version 2 of the Simple Network Management
Protocol (SNMPv2). SNMPv2 Working Group.
RFC 1903, Textual Conventions for Version 2 of the Simple Network Management Protocol
(SNMPv2). SNMPv2 Working Group.
RFC 1904, Conformance Statements for Version 2 of the Simple Network Management Protocol
(SNMPv2). SNMPv2 Working Group.
RFC 1905, Protocol Operations for Version 2 of the Simple Network Management Protocol
(SNMPv2). SNMPv2 Working Group.
RFC 1906, Transport Mappings for Version 2 of the Simple Network Management Protocol
(SNMPv2).
RFC 1907, Management Information Base for Version 2 of the Simple Network Management
Protocol (SNMPv2). SNMPv2 Working Group.
-41-
Page 53
MNS-BB Software User Guide
RFC 1908, Coexistence between Version 1 and Version 2 of the Internet-standard Network
Management Framework. SNMPv2 Working Group.
RFC 2104, Keyed Hashing for Message Authentication
RFC 2271, An Architecture for Describing SNMP Management Frameworks.
RFC 2272, Message Processing and Dispatching for the Simple Network Management Protocol
(SNMP).
RFC 2273, SNMPv3 Applications.
RFC 2274, User-Based Security Model (USM) for version 3 of the Simple Network Management
Protocol (SNMPv3).
RFC 2275, View-Based Access Control Model (VACM) for the Simple Network Management
Protocol (SNMP).
8.9.4 CLI
Syntax: set snmp type=<v1|all>
This command lets the user choose which SNMP version the LE2425A and LEV2525A SNMP agent support. If the value is “v1”, the agent will only support SNMPv1 access. If “all”, the agent supports v1, v2c and v3 SNMP accesses. Note: By default SNMPv1 is enabled.
LE2425A#set snmp type=v1 LE2425A#show snmp
SNMP CONFIGURATION INFORMATION
-----------------------------­ SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : disabled SNMP Access Status : enabled
SNMP MANAGERS INFO
-----------------­ SNMP TRAP STATIONS INFO
-----------------------
LE2425A#set snmp type=all LE2425A#show snmp
SNMPv3 Configuration Information ================================== System Name : LE2425A System Location : Lawrence, PA System Contact : support@blackbox.com Authentication Trap : Disabled Default Trap Comm : public V3 Engine ID : LE2425
Syntax: show snmp This command shows simple SNMP agent configuration such as system name, location, contact, etc. Depending on agent support type, it either shows v1 configuration or v3 configuration.
LE2425A#show snmp
SNMPv3 Configuration Information ================================== System Name : LE2425A System Location : Lawrence, PA System Contact : support@blackbox.com Authentication Trap : Disabled
-42-
Page 54
MNS-BB Software User Guide
Default Trap Comm : public V3 Engine ID : LE2425
Syntax: setvar[sysname|syscontact|syslocation]=<string> This command sets the system name, contact and location. All parameters are optional but a user must supply at least one parameter.
LE2425A(snmpv3)##setvar sysname=my_LE syscontact=admin syslocation=lab
Syntax: quickcfg This command is a quick setup for snmpv3 configuration. It automatically configures a default VACM (view-based access control model). This allows any manager station to access the LE2425A and LEV2525A switch. Either via v1, v2c or v3 models. The community name is “public”. This command is only intended for first time users and may be changed by administrators who want more strict access.
LE2425A(snmpv3)#quickcfg
This will enable default VACM.
Do you wish to proceed? [ 'Y' or 'N' ] Quick configuration done, default VACM enabled
Syntax: engineid string=<string> The agent has to have an engineID to be able to respond to SNMPv3 messages. The default engine ID value is “6K_v3Engine”. This command allows the user to change the engine ID.
LE2425A(snmpv3)##engineid string=LE2425
Engine ID is set successfully
LE2425A(snmpv3)##show-engineid
Engine ID : LE2425
Syntax: authtrap <enable|disable> This command enables or disables authentication traps generation.
LE2425A(snmpv3)##authtrap enable
Authentication trap status is set successfully
Syntax: show-authtrap This shows the current value of authentication trap status.
LE2425A(snmpv3)##show-authtrap
Authentication Trap Status: Disabled
Syntax: deftrap community=<string>
This command defines the default community string to be used when sending traps. When user does not specify the trap community name when setting a trap station using the “trap” command, the default trap community name is used.
LE2425A(snmpv3)##deftrap community=mysecret
Default trap community is set successfully
Syntax: show-deftrap
-43-
Page 55
MNS-BB Software User Guide
This shows the current value of default trap.
LE2425A(snmpv3)##show-deftrap
Default Trap Community : public
Syntax: trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<host-ip>] [community=<string>] [port=<1-65534>]
This command is used to define the trap and inform manager stations. The station can receive v1, v2 traps and/or inform notifications. An inform notification is an acknowledgments that a trap has been received. A user can add up to 5 stations.
LE2425A(snmpv3)##trap add id=1 type=v1 host=10.21.1.100
Entry is added successfully
Syntax: show-trap [id=<id>] This commands shows the configured trap stations in tabular format. id – [optional] the trap entry number in the table.
LE2425A(snmpv3)##show-trap
LE2425A(snmpv3)##show-trap id=1
Syntax: com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>]
This command is part of the VACM model. This specifies the mapping from a source/community pair to a security name. A user can specify up to 10 entries.
LE2425A(snmpv3)##com2sec add id=1 secname=public source=default community=public
Entry is added successfully
Syntax: show-com2sec [id=<id>]
LE2425A(snmpv3)##show-com2sec
LE2425A(snmpv3)##show-com2sec id=1
-44-
Page 56
MNS-BB Software User Guide
Syntax: group <add|delete> id=<id> [groupname=<name>] [model=<v1|v2c|usm>] [com2secid=<com2sec-id>]
This command is part of the VACM. This directive defines the mapping from sec model/sec name to group. A sec model is one of v1, v2c, or usm. User can specify up to 10 entries.
LE2425A(snmpv3)##group add id=1 groupname=v1 model=v1 com2secid=1
Entry is added successfully
Syntax: show-group [id=<id>]
This command shows all or specific group entries. id – [optional] this is the entry number and when specified, this shows a specific entry.
LE2425A(snmpv3)##show-group
ID Group Name Sec. Model Com2Sec ID ====================================== 1 v1 v1 1 2 -- -- -­ 3 -- -- -­ 4 -- -- -­ 5 -- -- -­ 6 -- -- -­ 7 -- -- -­ 8 -- -- -­ 9 -- -- -­ 10 -- -- --
LE2425A(snmpv3)##show-group id=1
Group ID : 1 Group Name : v1 Model : v1 Com2Sec ID : 1
Syntax: view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>]
[subtree=<oid>] [mask=<hex-string>]
This is part of the VACM commands. A view defines a manager or group or manager stations what it can access inside the MIB object tree. A user can define up to 10 entries.
LE2425A(snmpv3)##view add id=1 viewname=all type=included subtree=.1
Entry is added successfully
Syntax: show-view [id=<id>] This command shows all or specific view entries.
LE2425A(snmpv3)##show-view
ID View Name Type Subtree Mask ============================================= 1 all included .1 ff 2 -- -- -- --
-45-
Page 57
MNS-BB Software User Guide
3 -- -- -- -­ 4 -- -- -- -­ 5 -- -- -- -­ 6 -- -- -- -­ 7 -- -- -- -­ 8 -- -- -- -­ 9 -- -- -- -­ 10 -- -- -- --
LE2425A(snmpv3)##show-view id=1
View ID : 1 View Name : all Type : included Subtree : .1 Mask : ff
Syntax: access <add|delete> id=<id> [accessname=<name>]
[model=<v1|v2c|usm|any>] [level=<noauth|auth|priv>] [read=<none|view-id>] [write=<none|view-id>] [notify=<none|view-id>] [context=<none|context-string>] [prefix=<exact|prefix>]
This is also a part of VACM commands, the access command maps from group/security model/security level to a view. A user can add up to 10 access entries.
LE2425A(snmpv3)##access add id=1 accessname=v1 model=v1 level=noauth read=1
write=none notify=none
Entry is added successfully
Syntax: show-access [id=<id>] This command shows all or specific access entries.
LE2425A(snmpv3)##show-access
ID View Name Model Level R/View W/View N/View Context Prefix == =============== ===== ====== ====== ====== ====== ======== 1 v1 v1 noauth 1 none none "" exact 2 -- -- -- -- -- -- -- -­ 3 -- -- -- -- -- -- -- -­ 4 -- -- -- -- -- -- -- -­ 5 -- -- -- -- -- -- -- -­ 6 -- -- -- -- -- -- -- -­ 7 -- -- -- -- -- -- -- -­ 8 -- -- -- -- -- -- -- -­ 9 -- -- -- -- -- -- -- -­ 10 -- -- -- -- -- -- -- --
LE2425A(snmpv3)##show-access id=1
Access ID : 1 Access Name : v1 Sec. Model : v1 Sec. Level : noauth Read View ID : 1 Write View ID : none Notify View ID : none Context : "" Prefix : exact
-46-
Page 58
MNS-BB Software User Guide
Syntax: user <add|delete> id=<id> [username=<name>] [usertype=<readonly|readwrite>]
[authpass=<pass-phrase>] [privpass=<pass-phrase>] [level=<noauth|auth|priv>] [subtree=<oid>]
For quick v3 USM based security, this command adds user entries. One can add up to 5 users. Right now, the agent only support noauth and auth-md5 for v3 authentication and auth-des for priv authentication.
LE2425A(snmpv3)## user add id=1 username=RAJ usertype=readwrite
Syntax: show-user [id=<id>] This command shows all or specific user entries.
8.10 RMON
The switch supports RMON (Remote Monitoring) on all connected network segments. This allows for troubleshooting and optimizing your network.
The LE2425A and LEV2525A switches provide the hardware-based RMON counters in the switch chipset. The switch manager CPU polls these counters periodically to collect the statistics in a format that compiles with the RMON MIB definition. The following RMON groups are supported:
Ethernet Statistics Group - maintains utilization and error statistics for the switch
port being monitored.
History Group – gathers and stores periodic statistical samples from previous
Statistics Group.
Alarm Group – allows a network administrator to define alarm thresholds for any
MIB variable.
Log and Event Group – allows a network administrator to define actions based on
alarms. SNMP Traps are generated when RMON Alarms are triggered.
The RMON agent automatically runs in the switch. Use the RMON management station on your network to enable or disable specific RMON traps and events.
8.10.1 Adding RMON Communities in the Switch
The following RMON commands add new RMON communities: history def-owner = <string>
statistics def-owner = <string> alarm def-owner = <string> event def-owner = <string> e.g., LE2425A(rmon)## event def-owner = “test” The show command lists the RMON data of specified type. Syntax: show rmon <stats|hist|event|alarm>
LE2425A(snmp)##show rmon event
RMON Event Default Owner : monitor
RMON Event Default Community: public
8.11 Web: Viewing and Configuring SNMP Parameters
In the web browser interface:
1. Click on the [Administration]
2. Click on [SNMP].
-47-
Page 59
MNS-BB Software User Guide
You can modify community names, add SNMP manager station or add trap station from this menu.
9.0 Monitoring and Analyzing Switch Operation
9.1 Overview
The LE2425A and LEV2525A Switches have several built-in tools for monitoring, analyzing, and troubleshooting switch and network operations:
Status: Includes options for displaying general Switch information, management address data, and MAC addresses.
Event Log: Lists Switch operating events and Alert events.
Configurable trap receivers: Uses SNMP to enable management stations on your network to
receive the SNMP traps from the Switch.
Port monitoring (mirroring): Copies all traffic from the specified ports to a designated monitoring port.
9.2 Port Monitoring (Mirroring) Features
You can designate a port for monitoring traffic of one port (at a time) on the Switch. The Switch monitors the network activity by copying all traffic from the specified monitoring source (monitor port) to the designated monitoring (mirror or sniffer) port, to which a network analyzer can be attached.
9.2.1 CLI: Configuring Port Monitoring
You must use the following configuration sequence to configure port monitoring in the CLI:
1. Assign a monitoring (mirroring) or sniffer port.
2. Designate the port to monitor.
To list the ports assigned to mirror (receive monitored traffic) and the ports being monitored you need to use the command below: Syntax: show port-mirror For example, if you assign port 12 as the monitoring port and configure the Switch to monitor port 3, show port-mirror displays the following:
LE2425A # show port-mirror Port mirroring is Enabled Monitor Port is : 3 Sniffer Port is : 12
Configuring the monitor port assigns or removes a monitoring port. This must be executed from the configuration level. Removing the monitor port disables port monitoring and resets the monitoring parameters to their factory-default settings.
LE2425A # port-mirror <enter> LE2425A(port-mirror)##
syntax: setport monitor=<monitor port number> sniffer=<sniffer port number> For example, to assign port 12 as the monitoring port and 3 as the monitored port, type
LE2425A(port-mirror)## setport monitor=3 sniffer=12 Port 3 set as Monitor Port Port 12 set as Sniffer Port
To turn on or off the port monitoring
syntax: prtmr <enable|disable>
-48-
Page 60
MNS-BB Software User Guide
LE2425A(port-mirror)## prtmr enable Port Mirroring Enabled
LE2425A(port-mirror)## prtmr disable Port Mirroring Disabled
Note: Port Mirroring cannot be enabled until or unless user assigns the monitor and sniffer ports.
9.3 Limitation
One port can monitor at a time.
Source port and sniffer port must be the members of the same VLAN.
9.4 Web: Viewing Port Monitor status
In the web browser interface:
1. Click on the [Configuration]
2. Click on [Port].
3. Click on [Mirroring].
4. Click on [Modify] button.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
-49-
Page 61
MNS-BB Software User Guide
10.0 Optimizing Port Usage
10.1 Overview
This chapter includes:
Configuring port, status, mode (speed and duplex), and flow control parameters.
Configuration screens corresponding to the port numbers on the front of the switch.
10.2 CLI: Viewing Port Status and Configuring Port Parameters
From the CLI commands, you can configure and view all port parameter settings and view all port status indicators.
10.2.1 Port Status and Configuration Features
Status or Parameter Description
---------------------------------- -------------------­Status Enable (default): The port is ready for a network connection.
Disable: The port will not operate even when properly connected
in a network. Use this setting if the port needs to be shut down for diagnostic purposes or while you are making topology changes.
Link Up: The port senses a linkbeat.
Down: The port is not enabled, has no cables connected, or is experiencing a network error. For troubleshooting information, see the installation manual you received with the switch. See also chapter 10, “ Troubleshooting” (in this manual).
Mode The port’s speed and duplex (data transfer operation) setting.
10/100Base-T ports:
Auto (default): Senses speed and negotiates with the port at the other end of the link for data transfer operation (half-duplex or full-duplex). Note: Ensure that the device attached to the port is configured for the same setting that you selected here. Also, if “ Auto” is used, the device to which the port is connected must operate in compliance with the IEEE 802.3u “Auto Negotiation” standard for 100Base-T networks. If the other device does not comply with the 802.3u standard, or is not set to “Auto”, then the port configuration on the switch must be manually set to match the port configuration on the other device. To see what the switch negotiated for the Auto setting, use the CLI show port command.
Possible port setting combinations for copper ports.
9 10HDx: 10 Mbps, Half-Duplex 9 10FDx: 10 Mbps, Full-Duplex 9 100HDx: 100 Mbps, Half-Duplex 9 100FDx: 100 Mbps, Full-Duplex
Possible port settings for 100FX ports:
9 100FDx (default): 100 Mbps, Full-Duplex 9 100HDx: 100 Mbps, Half-Duplex
Possible port settings for 10FL ports:
9 10HDx (default): 10 Mbps, Half-Duplex 9 10FDx: 10 Mbps, Full-Duplex
100/1000Base-T ports:
Auto (default): Senses speed and negotiates with the port at the other end of the link for port operation (MDI-X or MDI).
-50-
Page 62
MNS-BB Software User Guide
To see what the switch negotiated for the Auto setting, use the CLI show port command.
9 1000Fdx: 1000 Mbps (1Gbps), Full-Duplex only 9 100Fdx: 100 Mbps, Full-Duplex
Notes:
• To change the port speed on a transceiver port you are required to reboot the switch.
• Ensure that the device attached to the port is configured for the same setting that you selected here. Also, if “ Auto” is used, the device the port is connected to must also be configured to “ Auto” and operate in compliance with the IEEE 802.3ab “ Auto Negotiation” standard for 1000Base-T networks.
Gigabit fiber-optic ports (Gigabit-SX and Gigabit-LX):
9 1000FDx (default): 1000 Mbps (1 GBPS), Full Duplex
only
Auto: The port operates at 1000FDx and auto-negotiates flow control with the device connected to the port.
Flow Control Disabled (default): The port will not generate flow control
packets and drops received flow control packets.
Enabled: The port uses 802.3x Link Layer Flow Control, generates flow control packets, and processes received flow control packets. With the port mode set to “Auto” (the default) and “Flow Control” set to enabled, the switch negotiates Flow Control o n the indicated port. If the port mode is not set to “Auto”, or if “Flow Control” is disabled on the port, then Flow Control is not used.
Back Pressure Disabled (default): The port will no t h ave
congestion control.
Enabled: The port uses 802.3 Layer 2 back off algorithms. Back
pressure-based congestion control on half-duplex, 10-Mbps Ethernet ports.
10.2.2 Port Status and Configuration Commands
From the CLI, you can configure and view all port parameter settings and all port status indicators. Please see CLI section for details.
10.2.3 Using the CLI to View Port Status
Use the following commands to display port status and configuration:
show port: Lists the full status and configuration for all ports on the switch.
Syntax: show port LE2425A# show port
Back pressure-based
-51-
Page 63
MNS-BB Software User Guide
Syntax: show port=<Port number>: Lists the status of the specific port.
LE2425A# show port=2
10.2.4 Using the CLI to Configure Ports
You can configure one or more of the following port parameters under device module. LE2425A#device <enter>
LE2425A(device)##
For details on each option, see Table above.
Syntax: setport port=<port|list|range> [name=<name>] [speed=<10|100>] [duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>]
For example, to configure ports 1 through 4 and port 7 for 100Mbps full-duplex, you would enter this command:
Note: The factory default setting for 10/100 copper ports is "Auto-negotiation Enabled". Before changing the port setting of a copper port, you have to ‘Disable’ the Auto- negotiation
LE2425A(device)## setport port=1-4,7 speed=100 duplex=full
Similarly, to configure a single port with the settings in the above command, you could enter the same command with only the one port identified.
LE2425A(device)## setport port=7 speed=100 duplex=full
If port 8 was disabled, and you wanted to enable it and configure it for 100FDx you could do so with the following command.
LE2425A(device)## setport port=8 status=enable speed=100 duplex=full
To set flowcontrol Syntax: flowcontrol xonlimit=<value> xofflimit=<value>
Where, xonlimit can be from 3 to 127, default value is 4 xofflimit from 3 to 127, default value is 6
LE2425A#show flowcontrol
XOnLimit : 4 XOffLimit : 6
To set BackPressure Syntax: backpressure rxthreshold=<value>
Where,
-52-
Page 64
MNS-BB Software User Guide
rxthreshold value can be from 3 to 127, default is 28
LE2425A#show backpressure
Rx Buffer Threshold : 28
To set the Age Time
Syntax: setage time=<timeout-period> Note: Default value is 300 seconds.
LE2425A#show age
Address table age time = 300
10.3 Web: Viewing Port Status and Configuring Port Parameters
In the web browser interface:
1. Click on the Configuration.
2. Click on [Port].
3. Click on [Settings].
4. Select a port to modify.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
10.4 Broadcast Storm Protection
One of the best features of the LE2425A and LEV2525A switches is its ability to keep broadcast storms from spreading throughout a network. Network storms are characterized by an excessive number of broadcast packets being sent over the network. These storms can occur if network equipment is configured incorrectly, network software is not properly functioning, or poorly designed programs (including some network games) are used. Storms can reduce network performance and cause bridges, routers, workstations, servers and PC's to slow down or even crash.
10.4.1 How does it works
The LE2425A and LEV2525A are capable of detecting and limiting storms on each interface (Port). A network administrator can set the maximum number of broadcast frames (Threshold value) that are permitted from a particular interface every second. If that maximum number is exceeded, a storm condition is declared. Once it is determined that a storm is occurring on an interface, any additional broadcast packets received on that interface will be dropped until the storm is determined to be over. The storm is determined to be over when a one-second period elapses with no broadcast packets received on that interface.
10.4.2 CLI: To Enable/Disable the broadcast Protection
Syntax: broadcast-protect <enable|disable> LE2425A(device)##broadcast-protect enable
Broadcast Storm Protection enabled
10.4.3 To set the Threshold value
Syntax: rate-threshold port=<port|list|range> rate=<frms/sec> In most situations, you will not need to set the Storm Thresholds. However, if intensive
broadcast messaging is typical to the network protocols used in your network environment, you may wish to control the maximum number of broadcast messages or frames per second that will be bridged from a particular host. If the maximum value of broadcast per second is exceeded, the Access Point will drop all subsequent messages of that type from that source address.
10.4.4 How to Protect against Broadcast Storms
Syntax: broadcast-protect enable LE2425A(device)##broadcast-protect enable
LE2425A#show broadcast-protect
-53-
Page 65
MNS-BB Software User Guide
============================================================= PORT | STATUS | THRESHOLD (frms/sec) | CURR RATE (frms/sec) | ACTIVE ============================================================= 1 Enabled 4294967295 0 NO 2 Enabled 4294967295 0 NO 3 Enabled 4294967295 0 NO 4 Enabled 4294967295 0 NO 5 Enabled 4294967295 0 NO 6 Enabled 4294967295 0 NO 7 Enabled 4294967295 0 NO 8 Enabled 4294967295 0 NO 9 Enabled 4294967295 0 NO 10 Enabled 4294967295 0 NO 11 Enabled 4294967295 0 NO 12 Enabled 4294967295 0 NO 13 Enabled 4294967295 0 NO 14 Enabled 4294967295 0 NO 15 Enabled 4294967295 0 NO 16 Enabled 4294967295 0 NO 17 Enabled 4294967295 0 NO 18 Enabled 4294967295 0 NO 19 Enabled 4294967295 0 NO 20 Enabled 4294967295 4000 YES 21 Enabled 4294967295 0 NO 22 Enabled 4294967295 0 NO 23 Enabled 4294967295 0 NO 24 Enabled 4294967295 0 NO
25 Enabled 4294967295 0 NO
In this example Port 20 has broadcast packets To avoid the packet storm you need to set up the threshold value. Threshold value should be less than the current rate.
LE2425A(Device)## rate-threshold port=20 rate= 3500 LE2425A(Device)## show broadcast-protect ============================================================= PORT | STATUS | THRESHOLD (frms/sec) | CURR RATE (frms/sec) | ACTIVE =============================================================
1 Enabled 4294967295 0 NO 2 Enabled 4294967295 0 NO 3 Enabled 4294967295 0 NO 4 Enabled 4294967295 0 NO 5 Enabled 4294967295 0 NO 6 Enabled 4294967295 0 NO 7 Enabled 4294967295 0 NO 8 Enabled 4294967295 0 NO 9 Enabled 4294967295 0 NO 10 Enabled 4294967295 0 NO 11 Enabled 4294967295 0 NO 12 Enabled 4294967295 0 NO 13 Enabled 4294967295 0 NO 14 Enabled 4294967295 0 NO 15 Enabled 4294967295 0 NO 16 Enabled 4294967295 0 NO 17 Enabled 4294967295 0 NO 18 Enabled 4294967295 0 NO 19 Enabled 4294967295 0 NO
20 Enabled 3500 4000 YES
21 Enabled 4294967295 0 NO 22 Enabled 4294967295 0 NO 23 Enabled 4294967295 0 NO 24 Enabled 4294967295 0 NO 25 Enabled 4294967295 0 NO
User can also disable/enable a particular port or a set of ports for broadcast storm protection.
-54-
Page 66
MNS-BB Software User Guide
11.0 QoS (Quality of Service)
11.1 Overview
Quality of Service (QoS) refers to the capability of a network to provide better service to selected network traffic over various technologies, including Frame Relay, Asynchronous Transfer Mode (ATM), Ethernet and 802.1 networks, SONET, and IP-routed networks that may use any or all of these underlying technologies. The primary goal of QoS is to provide priority including dedicated bandwidth.
11.2 QoS Concepts
Fundamentally, QoS enables you to provide better service to certain flows. This is accomplished by either raising the priority of a flow or limiting the priority of another flow. When using congestion­management tools, you try to raise the priority of a flow by queuing and servicing queues in different ways. The queue management tool used for congestion avoidance raises priority by dropping lower­priority flows before higher-priority flows. Policing and shaping provide priority to a flow by limiting the throughput of other flows.
The LE2425A and LEV2525A switches support QoS as specified in the IEEE 802.1p and 802.1Q standards. QoS can be important in network environments where there are time-critical applications, such as voice transmission or video conferencing, which can be adversely effected by packet transfer delays. QoS was designed to address this problem. The 802.1p standard outlines eight levels of priority, 0 to 7, with 0 the lowest priority and 7 the highest. The LE2425A and LEV2525A switches have two priority queues, 1 (low) and 0 (high). When a tagged packet enters a switch port, the switch responds by placing the packet into one of the two queues
11.3 IP Precedence: Differentiated QoS
IP precedence utilizes the 3 precedence bits in the IPv4 header's Type of Service (ToS) field to specify class of service for each packet. You can partition traffic in up to eight classes of service using IP precedence. The queuing technologies throughout the network can then use this signal to provide the appropriate expedited handling.
This Diagram Shows the IP Precedence ToS Field in an IP Packet Header
The 3 most significant bits (correlating to binary settings 32, 64, and 128) of the Type of Service (ToS) field in the IP header constitute the bits used for IP precedence. These bits are used to provide a priority from 0 to 7 for the IP packet.
Because only 3 bits of the ToS byte are used for IP precedence, you need to differentiate these bits from the rest of the ToS byte.
11.4 DiffServ
QoS (quality of service) refers to the level of preferential treatment a packet receives when it is being sent through a network. QoS allows time sensitive packets, such as voice and video, to be given priority over time insensitive packets, such as data. Differentiated services (DiffServ or DS) is a set of technologies defined by the IETF (Internet Engineering Task Force) to provide quality of service for traffic on IP networks.
DiffServ is designed for use at the edge of the enterprise where corporate traffic enters the service provider environment. DiffServ is a layer-3 protocol and requires no specific layer-2 capability,
-55-
Page 67
MNS-BB Software User Guide
allowing it to be used in the LAN, MAN, and WAN. DiffServ works by tagging each packet (at the originating device or an intermediate switch) for the requested level of serv ice it requires across the network.
DiffServ inserts a 6-bit DiffServ code point (DSCP) in the TOS (type of service) field of the IP header, as shown in the picture above. Information in the DSCP allows nodes to determine the per hop behavior (PHB), which is an observable forwarding behavior for each packet. Per hop behaviors are defined in according to:
Resources required (e.g., bandwidth, buffer size)
Priority (based on application or business requirements)
Traffic characteristics (e.g., delay, jitter, packet loss)
Nodes implement PHBs through buffer management and packet scheduling mechanisms. This hop-by-hop allocation of resources is the basis by which DiffServ provides quality of service fo r different types of communications traffic.
11.5 PQ: Priority Queuing
PQ ensures that important traffic gets the fastest handling at each point where it is used. It was designed to give strict priority to important traffic. Priority queuing can flexibly prioritize according to network protocol (for example IP, IPX, or AppleTalk), incoming interface, packet size, source/destination address, and so on. In PQ, each packet is placed in one of two queues—high or low—based on an assigned priority. Packets that are not classified by th is priority list mechanism fall into the normal queue. Note: LE2425A and LEV2525A Switches support two priority queues, 1 (low) and 0 (high) During transmission, the algorithm gives higher-priority queues absolute preferential treatment over low-priority queues.
11.6 QoS Management
The introduction discussed a common method (but by no means the only method) for QoS management. For baselining a network, you can use RMON probes and an application (such as Traffic Director) to develop a good understanding of traffic characteristics. RMON probes provide more complete information. In addition, targeted applications should be baselined (this is commonly measured by response time). This information helps to validate any QoS deployment. From this data, QoS policy is set and deployed.
Once deployed, it is important to evaluate the QoS policies and deployment and to decide whether additional services are needed. In addition, RMON probes should still continue to monitor the network because the traffic characteristics likely will change. A constant look at network traffic will help with changing trends and allow a network administrator to address new network requirements
-56-
Page 68
MNS-BB Software User Guide
more expeditiously.
11.7 QoS on Ethernet
The LE2425A and LEV2525A Switches have the capability to provide QoS at Layer 2. At Layer 2, the frame uses type of service (ToS) as specified in IEEE 802.1p . ToS uses 3 bits, just like IP precedence, and maps well from Layer 2 to layer 3, and vice versa.
The switches have the capability to differentiate frames based on ToS settings. When two queues are present (high or low), frames can be placed in either and serviced via the weight set on all ports. This placement of queues, added to the weight set plus the particular tag setting on a packet allows each queue to have different service levels.
The QoS implementations provided mapping of ToS (or IP precedence) to CoS (class of service). In this instance, an Ethernet frame CoS setting can be mapped to the ToS byte of the IP packet, and vice versa. A ToS level of 1 equals a CoS level of 1. This provides end-to-end priority for the traffic flow.
11.8 CLI
LE2425A and LEV2525A Switches support three types of QoS; Port based, Tag based and ToS based (Layer 3).
11.8.1 To set the QoS type on the switch.
LE2425A#qos <enter> LE2425A(qos)##
Note: QoS is disabled by default on the switch. Set QoS <type> [ports] [priority] [tos] [tag] : Sets the QOS for a particular port. The following types
of QOS are supported:
a. Port QOS b. Tag QOS c. Tos QOS (Layer 3) d. None.
Note: Not all packets received on a port have high priority. IGMP and BPDU packets have high priority by default.
11.8.2 Functions of QoS settings:
Port QOS: If we set a port to high priority then all the packets received on that port will be assigned
to high priority regardless of the type of the packet.
TAG QOS: If a packet contains a tag, the port (if tag QoS is enabled) on which the packet was received then looks to see at which level that tag value is set. Regardless of the tag value, if there is a tag, that packet is automatically assigned high priority.
TOS QOS: (Layer 3) When a port is set to TOS QOS, the most significant 6-bits of the IPv4 packet (which has 64 bits) are used. If the 6 bits are set to TOS QOS for the specific port number the packet went to, that packet is assigned high priority by that port.
Syntax: setqos type=<port|tag|tos|none> [port=<port|list|range>] [priority=<high|low>] [tos=<0-63|list|range>][tag=<0-7|list|range>]
Depending on the type of QOS, the corresponding field has to be set. For example, for QOS type tag, the tag levels have to be set, and for QOS type ToS, the ToS levels have to be set. If the priority field is not set, it then defaults to low priority. ToS has 64 levels and the valid values are 0-63 and a tagged packet has 8 levels and the valid values are 0-7.
Note: Setting type to none will clear the QOS (Disable) for all the ports.
Set port weight: Sets the port priority weight for All the ports. Once the weight is set, all the ports
-57-
Page 69
MNS-BB Software User Guide
will be the same weight across the switch. The valid value for weight is 0-7.
Syntax: set-weight weight=<0-7>
Note A weight is a number calculated from the IP precedence setting for a packet in flow. This
weight is used in an algorithm to determine when the packet will be serviced.
Weight settings can be viewed using the show-portweight command.
As mentioned previously, the switch is capable of detecting higher-priority packets marked with precedence by the IP forwarder and can schedule them faster, providing superior response time for this traffic. The IP Precedence field has values between 0 (the default) and 7. As the precedence value increases, the algorithm allocates more bandwidth to that traffic to make sure that it is served more quickly when congestion occurs. We can assign a weight to each flow, which determines the transmit order for queued packets. In this scheme, lower weights (set on all ports) are provided more service. IP precedence serves as a divisor to this weighting factor. For instance, traffic with an IP Precedence field value of 7 gets a lower weight than traffic with an IP Precedence field value of 3, and thus has priority in the transmit order.
Syntax: set-weight weight=<0-7>
Once you set the Port weight, the hardware will interpret the weight setting for all ports as outlined below:
Hardware Interpretation
Setting 0 - 1 packet transmitted from HIGH, 1 packet from LOW 1 - 2 packet transmitted from HIGH, 1 packet from LOW 2 - 4 packet transmitted from HIGH, 1 packet from LOW 3 - 6 packet transmitted from HIGH, 1 packet from LOW 4 - 8 packet transmitted from HIGH, 1 packet from LOW 5 - 10 packet transmitted from HIGH, 1 packet from LOW 6 - 12 packet transmitted from HIGH, 1 packet from LOW 7 - All packets transmitted from HIGH, 0 packets from LOW.
show portweight : Shows the global port priority weight.
Syntax: show-portweight
Note: Port weight can be assign only globally (the whole switch has the same setting)
LE2425A(qos)##show-portweight Port priority Weight set to 1 High : 1 Low.
Show qos : It shows the QoS information. Syntax: show qos [type=<port|tag|tos>] [port=<port|list|range>]
For example, To set the QoS type as “Port” and set particular ports (1-5) with high priority.
LE2425A(qos)##setqos type=port port=1-5 priority=high
To see the QoS status.
-58-
Page 70
MNS-BB Software User Guide
LE2425A(qos)##show qos
To see the QoS type LE2425A(qos)##show qos type=port
To set QoS type Tag,
This command will set the bits making tag levels 0, 4 and 7 high priority. LE2425A(qos)##setqos type=tag port=6-10 tag=0,4,7 priority=high
To show the tag level (0-7) LE2425A(qos)##show qos type=tag
Note: The default setting for traffic class is the low priority queue.
All tagged frames will be directed to either the low or high priority queue as specified.
11.9 To tag untagged packets.
When a packet is received untagged and has to be transmitted, with an addition of 802.1Q tag on transmit, then 802.1p priority tag is assigned depending on the untag value set. Hence if you set untag port=1 tag=2 priority=low, untagged packets received on that port will be tagged with a priority low upon transmit.
set-untag : The 802.1p user priority assigned to untagged received packets to be transmitted as tagged from the priority queue 1/0.
-59-
Page 71
MNS-BB Software User Guide
Syntax: set-untag port=<port|list|range> priority=<high|low> tag=<0-7>
11.10 Web: Configure QoS
In the web browser interface:
1. Click on the [Configuration]
2. Click on [QoS].
3. Click on [Modify].
4. After you make the desired changes, click on [OK] button.
5. Click [Save] to save the configuration.
12.0 IGMP
12.1 Overview
In a network where IP multicast traffic is transmitted for various multimedia applications, you can use the switch to reduce unnecessary bandwidth usage on a per-port basis by configuring IGMP (Internet
-60-
Page 72
MNS-BB Software User Guide
Group Management Protocol controls). In the factory default state (IGMP disabled), the switch forwards all IGMP traffic to all ports, which can cause unnecessary bandwidth usage on ports not belonging to multicast groups. Enabling IGMP allows the ports to detect IGMP queries, report packets and manage IP multicast traffic through the switch.
12.2 Purpose
The purpose of IGMP Snooping is to limit multicast traffic to only those LAN segments that are interested in receiving the messages. In normal switch operations without IGMP, IP multicast traffic is flooded through out the whole LAN. It is flooded because a switch usually learns MAC address by looking in to the source address field of all the frames it receives. However, since a multicast address is never used as a source address for a packet (it has several false addresses which are not unique) and since they do not appear in the MAC address table (because they are not real), the switch has no method for learning them. The most efficient method to weed them out is to use IGMP Snooping. With IGMP Snooping the switch intercepts the IGMP messages (multicast messages only) from the host itself and updates its MAC table accordingly.
IGMP is useful in multimedia applications such as LAN TV, desktop conferencing, and collaborative computing, where there is multipoint communication; that is, communication from one to many hosts, or communication originating from many hosts and destined for many other hosts. In such multipoint applications, IGMP will be configured on the hosts, and multicast traffic will be generated by one or more servers (inside or outside of the local network). Switches in the network (that support IGMP) can then be configured to direct the multicast traffic to only the ports where needed.
Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch. If no other querier is detected, the switch will then also function as the querier. (If you need to disable the querier feature, you can do so through the IGMP configuration MIB. Refer to “Changing the Querier Configuration Setting”)
12.3 IGMP Operating Features
In the factory default configuration, IGMP is disabled. IGMP works only on default VLAN (DEFAULT_VLAN; VID = 1). When you use either the CLI or the Telnet interface to enable IGMP on the switch, the switch forwards IGMP traffic only to ports belonging to multicast groups.
¾ Auto/Blocked/Forward: You can use the console to configure individual ports to any of the following
states:
Auto (the default): Causes the switch to interpret IGMP packets and to filter IP multicast traffic
based on the IGMP packet information for ports belonging to a multicast group. This means that IGMP traffic will be forwarded on a specific port only if an IGMP host or multicast router is connected to the port.
Blocked: Causes the switch to drop all IGMP transmissions received from a specific port and to
block all outgoing IP Multicast packets for that port. This has the effect of preventing IGMP traffic from moving through specific ports.
Forward: Causes the switch to forward all IGMP and IP multicast transmissions through the
port.
¾ Querier: In the default state (enabled), eliminates the need for a multicast router. In most cases,
Blackbox recommends that you leave this parameter in the default “enabled” state even if you have a multicast router performing the querier function in your multicast group.
12.4 Benefit
The IGMP Snooping feature enables the switch to monitor the flow of queries from the router and reports from the host nodes to build its own multicast membership lists. It uses the lists to forward multicast packets only to switch ports where there are host nodes that are members of multicast groups. This improves switch performance and network security by further restricting the flow of multicast packets only to those switch ports connected to host nodes. Without IGMP Snooping, the switch would flood all multicast packets out all of its ports, except the port on which it received the packet. Such flooding of packets can negatively impact switch and network performance.
-61-
Page 73
MNS-BB Software User Guide
12.5 How IGMP Operates
The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, multicast routers, and hosts that support IGMP. (In the LE2425A and LEV2525A Switches implementation of IGMP, a multicast router is not necessary as long as a switch is configured to support IGMP with the querier feature enabled.) A set of hosts, routers, and/or switches that send or receive multicast data streams to or from the same source(s) is termed a multicast group, and all devices in the group use the same multicast group address. The multicast group running version 2 of IGMP uses three fundamental types of messages to communicate:
Query: A message sent from the querier (multicast router or switch) asking for a response from
each host belonging to the multicast group. If a multicast router supporting IGMP is not present, then the switch must assume this function in order to elicit group membership information from the hosts on the network. (If you need to disable the querier feature, you can do so through the CLI, using the IGMP configuration MIB. See “Changing the Querier Configuration Setting” on page “Configuring the Querier Function”)
Report: A message sent by a host to the querier to indicate that the host wants to be or is a
member of a given group indicated in the report message.
Leave Group: A message sent by a host to the querier to indicate that the host has ceased to be a
member of a specific multicast group. Thus, IGMP identifies members of a multicast group (within a subnet) and allows IGMP-configured hosts (and routers) to join or leave multicast groups.
12.6 IGMP Data.
To display data showing active group addresses, reports, queries, querier access port, and active group address data (port, type, and access), see “CLI Section”.
12.7 Role of the Switch
When IGMP is enabled on the switch, it examines the IGMP packets it receives:
To learn which of its ports are linked to IGMP hosts and multicast routers/ queriers belonging to any multicast group. To become a querier if a multicast router/querier is not discovered on the network.
Once the switch learns the port location of the hosts belonging to any particular multicast group, it can direct group traffic to only those ports, resulting in bandwidth savings on ports where group members do not reside. The following example illustrates this operation.
Figure (below) shows a network running IGMP.
PCs 1 and 4, switch 2, and all of the routers are members of an IP multicast group. (The
routers operate as queriers.)
Switch 1 ignores IGMP traffic and does not distinguish between IP multicast group members
and non-members. Thus, it is sending large amounts of unwanted multicast traffic out the
ports to PCs 2 and 3.
Switch 2 is recognizing IGMP traffic and learns that PC 4 is in the IP multicast group
receiving multicast data from the video server (PC X). Switch 2 then sends the multicast data
only to the port for PC 4, thus avoiding unwanted multicast traffic on the ports for PCs 5 and
6.
-62-
Page 74
MNS-BB Software User Guide
Figure: The Advantage of Using IGMP
The next figure (below) shows a network running IP multicasting using IGMP without a multicast router. In this case, the IGMP-configured switch runs as a querier. PCs 2, 5, and 6 are members of the same IP multicast group. IGMP is configured on switches 3 and 4. Either of these switches can operate as querier because a multicast router is not present on the network. (If an IGMP switch does not detect a querier, it automatically assumes this role, assuming the querier feature is enabled—the default—within IGMP.)
Figure: Isolating IP Multicast Traffic in a Network
In the above figure, the multicast group traffic does not go to switch 1 and beyond because either
the port on switch 3 that connects to switch 1 has been configured as blocked or there are no
-63-
Page 75
MNS-BB Software User Guide
hosts connected to switch 1 or switch 2 that belong to the multicast group.
For PC 1 to become a member of the same multicast group without flooding IP multicast traffic
on all ports of switches 1 and 2, IGMP must be configured on both switches 1 and 2, and the port on Switch 3 that connects to Switch 1 must be unblocked.
12.8 IP Multicast Filters
IP multicast addresses occur in the range from 224.0.0.0 through 239.255.255.255 (which corresponds to the Ethernet multicast address range of 01005e-000000 through 01005e-7fffff). Devices such as the LE2425A or LEV2525A having static Traffic/Security filters configured with a “Multicast” filter type and a “Multicast Address” in this range will continue in effect unless IGMP learns of a multicast group destination in this range. In that case, IGMP takes over the filtering function for the multicast destination address(es) for as long as the IGMP group is active. If the IGMP group subsequently deactivates, the static filter resumes control over traffic to the multicast address formerly controlled by IGMP.
12.9 Reserved Addresses Excluded from IP Multicast (IGMP) Filtering.
Traffic to IP multicast groups in the IP address range of 224.0.0.0 to 224.0.0.255 will always be flooded because addresses in this range are “well known” or “reserved” addresses. Thus, if IP Multicast is enabled and there is an IP multicast group within the reserved address range, traffic to that group will be flooded instead of filtered by the switch.
12.10 IGMP Support
LE2425A and LEV2525A support IGMP version 1 and version 2. The switch can act either as a querier or a nonquerier. The querier router periodically sends general query messages to solicit group membership information. Hosts on the network that are members of a multicast group send report messages. When a host leaves a group, it sends a leave group message.
The difference between Version 1 and Version 2 is that version 1 does not have a “Leave” mechanism for the host.
LE2425A and LEV2525A do support pruning when there is a leave message or a time expires on a port, they prune the multicast group membership on that port.
Note: The LE2425A and LEV2525A support only the default VLAN. It can be enabled within a port VLAN, tagged VLAN, or no VLAN. It can snoop up to 256 Multicast Groups.
12.11 CLI
12.11.1 Enable/disable IGMP
Syntax: igmp <enable/disable> Note: By default IGMP is disable.
To enable and disable IGMP in the switch, first go to IGMP context using the command “igmp” or “configure igmp”.
LE2425A##igmp LE2425A(igmp)##
LE2425A(igmp)##igmp disable
IGMP is disabled
LE2425A(igmp)##igmp enable
IGMP is enabled
-64-
Page 76
MNS-BB Software User Guide
12.11.2 Showing IGMP Configuration
To show current IGMP operation, use the command “show igmp” available globally in the command line. For example:
LE2425A#show igmp
IGMP State shows if IGMP is turned on (Enable) or off (Disable).
Immediate Leave provides a mechanism for a particular host that wants to leave a multicast group. It disables the port (where the leave message is received) ability to transmit multicast traffic.
Querier shows where the switch is acting a querier or a non-querier.
Querier interval shows the time period in seconds on which the switch sends general host-query
messages.
Querier response interval specifies maximum amount of time in seconds that can elapse between when the querier sends a host-query message and when it receives a response from a host.
12.11.3 Showing Snooped Multicast Groups
Using the command “show-group” in IGMP command context will show the multicast groups being snooped. For example:
LE2425A(igmp)##show-group
The GroupIp column shows the multicast groups. PortNo shows the port where the multicast group is being detected. Timer shows the amount of time left in seconds before the group port will be deleted (will not be able to route multicast traffic) if the switch does not receive a membership report. Leave pending column shows the number of leave messages received from this port.
12.11.4 Showing Detected Router Ports
To view detected IGMP-enabled router ports, use the command “show-router” in the IGMP command context. For example:
LE2425A(igmp)##show-router
RouterIp PortNo Timer
--------------------------------------
10.21.1.250 9 25
12.11.5 Enable/Disable Immediate Leave Processing
To enable or disable the switch to immediately process a host sending a leave message rather that wait for the timer to expire, use the command “set-leave” in the IGMP command context.
Syntax: set-leave <enable|disable> LE2425A(igmp)##set-leave enable
IGMP immediate leave status is enabled
-65-
Page 77
MNS-BB Software User Guide
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Enabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10
LE2425A(igmp)##set-leave disable IGMP immediate leave status is disabled
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10
12.11.6 Enable/Disable Switch as Querier
To enable or disable a switch as IGMP querier, use the command “set-querier” in the IGMP command context.
Syntax: set-querier <enable|disable> LE2425A(igmp)##set-querier enable
IGMP querier status is enabled
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10
LE2425A(igmp)##set-querier disable
IGMP querier status is disabled
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 125 Querier Response Interval : 10
12.12 Setting the Host Membership Query Interval
The IGMP querier router periodically sends general host-query messages. These messages are sent to ask for group membership information. This is sent to the all-system multicast group address,
224.0.0.1.
Note: The default value is 125 seconds. The valid range can be from 60 to 127 seconds. To set the value, use the command “set-qi” in the IGMP command context.
Syntax: set-qi interval=<value> LE2425A(igmp)##set-qi interval=127
Query interval successfully set
-66-
Page 78
MNS-BB Software User Guide
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 127 Querier Response Interval : 10
12.13 Setting the Query Response Interval
The query response interval is the maximum amount of time that can elapse between when the querier router sends a host-query message and when it receives a response from a host.
Note: The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the maximum value because of an internal calculation that is dependent on the value of the Query Interval.
Syntax: set-qri interval=<value>
LE2425A(igmp)##set-qri interval=11
Query response interval successfully set
LE2425A(igmp)##show igmp
IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 125 Querier Response Interval : 11
Every port can be individually set to three different IGMP modes (please see section “Showing IGMP Port Mode”). To set port mode, you use the command “set-port” in the IGMP command context.
User can use the console to configure individual ports to any of the following states: Auto/Blocked/Forward (As described above in IGMP Operating Features).
Auto – lets IGMP control whether the port should or should not participate sending multicast
traffic
Block – manually configures the port to always block multicast traffic
Forward – manually configures the port to always forward multicast traffic
12.14 Configure IGMP Port Mode
Syntax: set-port port=< port|list|range>> mode=<auto|forward|block>
LE2425A(igmp)##set-port port=1-2 mode=forward
Port mode is set.
12.14.1 Showing Port Configuration
To view the current setting of Ports in respect of IGMP.
-67-
Page 79
MNS-BB Software User Guide
Syntax: show-port LE2425A(igmp)## show-port
Note: The default mode is Auto.
12.15 Web: Configure and View
In the web browser interface:
1. Click on the [Configuration].
2. Click on [IGMP].
3. Click on [Information].
4. Click on [Modify] button.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
-68-
Page 80
MNS-BB Software User Guide
13.0 Spanning Tree Protocol (STP)
13.1 STP Features
The switch uses the IEEE 802.1D Spanning Tree Protocol (STP). When this STP is enabled, it ensures that only one path at a time is active between any two nodes on the network. In networks where more than one physical path exists between two nodes, STP ensures only a single path is active by blocking all redundant paths. Enabling STP is necessary in such networks because having more than one path between a pair of nodes causes loops in the network which can result in duplication of messages. This duplication leads to a “broad-cast storm” that can bring down the network. Note: You should enable STP in any switch that is part of a redundant physical link (loop topology). (It is recommended that you enable STP on all switches belonging to a loop topology.)
As recommended in the IEEE 802.1Q VLAN standard, the LE2425A and LEV2525A Switches use single-instance STP. This means a single spanning tree is created to make sure there are no network loops associated with any of the connections to the switch. This works regardless of whether VLANs are configured on the switch. Thus, these switches do not distinguish between VLANs when identifying redundant physical links.
13.2 Feature Default
enable/disable STP disabled reconfiguring general operation priority: 32768 max age: 20 s hello time: 2 s fwd. delay: 15 s reconfiguring per-port STP path cost: var priority: 128 mode: norm monitoring STP n/a
In the factory default configuration, STP is off. If a redundant link (loop) exists between nodes in your network, you should enable Spanning Tree.
Note STP retains its current parameter settings when disabled. Thus, if you disable STP, then later re­enable it, the parameter settings will be the same as before STP was disabled. Caution Because the switch automatically gives faster links a higher priority, the default STP parameter settings are usually adequate for spanning tree operation. Also because incorrect STP settings can adversely affect network performance, you should not make changes unless you have a strong understanding of how STP operates. For more on STP, see the IEEE 802.1D standard.
13.3 Viewing the Current STP Configuration.
Regardless of whether STP is disabled (the default), this command lists the switch’s full STP configuration, including general settings and port settings.
Syntax: show stp <config | port | age> LE2425A# show stp config STP Bridge Configuration:
In the default configuration, STP appears as shown here:
Spanning Tree Enabled(Global) :NO Spanning Tree Enabled(Ports) :YES, 9,10,11,12,13,14,15,16,17,18,19,20,21,22 Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2 Bridge Max Age :20 Root Port :0 Root Path Cost :0 Designated Root :80:00:00:20:06:25:00:11 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
-69-
Page 81
MNS-BB Software User Guide
13.3.1 Explaining Parameters in Detail
The following parameters are explained in detail.
Spanning Tree Enabled(Global): This field indicates whether STP is enabled or disabled globally i.e. if the values is YES, all ports have STP enabled, otherwise, all ports have STP disabled.
Spanning Tree Enabled(Ports): This field indicates which ports have STP enabled.
Bridge Priority: This field specifies the switch (bridge) priority value which is used along with the
switch MAC address to determine the root device. Lower values mean higher priority. Value ranges from 0 to 65535. Default value is 32768.
Bridge Forward Delay: This field indicates the time duration the switch will wait from listening to learning states and from learning to forwarding states. The value ranges from 4 to 30 seconds. Default value is 15.
Bridge Hello Time: When the switch is the root device, this is the time between messages being transmitted. The value is from 1 to 10 seconds. Default value is 2 seconds.
Bridge Max Age: This is the maximum age a received message with STP information is allowed by the switch before the switch checks all messages and updates the address table again. Value ranges from 6 to 40 seconds with default value of 20 seconds.
Root Port: This field indicates the port number, which is elected as the root port of the switch.
Root Path Cost: This field indicates the root ports path cost. A path cost is assigned to individual
ports for the switch to determine which ports are the forwarding points. A higher cost means more loops, a lower cost means fewer loops. More loops equal more traffic and a slower system.
Designated Root: This field shows the MAC address of the bridge in the network elected or designated as the root bridge.
Designated Root Priority: This field shows the designated root bridge’s priority.
Root Bridge Forward Delay: This field indicates the designated root bridge’s forward delay. This is
the time the switch waits from the listening to the forwarding state. The default is 15 seconds. Can be set between 4-30 seconds.
Root Bridge Hello Time: This field indicates the designated root bridge’s hello time.
Root Bridge Max Age: This field indicates the designated root bridge’s Max Age.
13.3.2 Showing STP Configuration by Port
To show STP configuration by ports, an example shows below
LE2425A#show stp ports STP Port Configuration:
-----------------------------------------------------------------------------------------­Port# Type Priority Path Cost State Des. Bridge Des. Port
-----------------------------------------------------------------------------------------­01 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:00:62 80:01 02 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:00:62 80:02 03 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:00:62 80:03 04 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:00:62 80:04 05 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:00:62 80:05 06 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:00:62 80:06 07 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:00:62 80:07 08 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:00:62 80:08
-70-
Page 82
MNS-BB Software User Guide
The command above outputs the result in tabular format. The explanation of each column in the table is shown below:
Port#: This field indicates the port number. Value ranges from 01 to max number of ports in the switch.
Type: This field indicates the type of port.
Port Priority: STP uses this to determine which ports are used for forwarding. Lower the number
means higher priority. Value ranges from 0 to 255. Default is 128.
Path Cost: This is the assigned port cost value used for the switch to determine the forwarding points. Values range from 1 to 65535.
State: This indicates the STP state of individual ports. Values can be Listening, Learning, Forwarding, Blocking and Disabled.
Des. Bridge: This is the port’s designated root bridge.
Des. Port: This is the port’s designated root port.
13.4 Enabling or Disabling STP.
Enabling STP implements the spanning-tree protocol for all physical ports on the switch, regardless of whether multiple VLANs are configured. Disabling STP removes protection against redundant loops that can significantly slow or halt a network.
Go to STP configuration mode to configure STP.
Syntax: stp <enter>
LE2425A#stp <enter> LE2425A(stp)##
To enable/disable STP
Syntax: stp <enable|disable> Default: Disabled
This command enables STP with the current parameter settings or disables STP without losing the most recently configured parameter settings. (To learn how the switch handles parameter changes, how to test changes without losing the previous settings, and how to replace previous settings with new settings, see appendix C, “ Switch Memory and Configuration”.) When enabling STP, you can also include the STP general and per-port parameters described in the next two sections. When you use the “no” form of the command, you can do so only to disable STP. (STP parameter settings are not changed when you disable STP, and cannot be included with the no spanning-tree command.
Caution: Because incorrect STP settings can adversely affect network performance, Blackbox recommends that you use the default STP parameter settings. You should not change these settings unless you have a strong understanding of how STP operates. For more on STP, see the IEEE 802.1D standard.
LE2425A(stp)## stp enable
-71-
Page 83
MNS-BB Software User Guide
13.5 Reconfiguring General STP Operation on the Switch.
This command enables STP (if it is not already enabled) and configures one or more of the following parameters:
General STP Operating Parameters Name Default Range Function
priority 32768 0 - 65535 Specifies the priority value used along with the switch MAC address to determine which device is root. The lower a
priority value, the higher the priority. maximum-age 20 seconds 6 – 40 sec Maximum received message age the switch allows for STP info before discarding messages and receiving new messages.
Name Default Range Function
hello-time 2 seconds 1 - 10 sec Time between message transmission when switch is the root. forward-delay 15 seconds 4 – 30 sec Time the switch waits before
transitioning from the listening to the learning state, and
between the learning state to the forwarding state.
Syntax to set the above-mentioned parameters:
priority port=<number|list|range> value=<0-255 / 0-65535> cost port=<number|list|range> value=<0-65535> time forward-delay=<4-30> hello=<1-10> age=<6-40>
Default: See table above.
For example, to enable STP with a maximum-age of 30 seconds and a hello-time of 3 seconds with forward delay of 15 secs: LE2425A(stp)## timers forward-delay=15 hello= 3 age= 30
13.6 Globally Enabling or Disabling STP
To globally enable or disable STP on the switch, one must be in the STP context in CLI. The following command sequence shows enabling and disabling STP globally.
LE2425A(stp)##show stp config STP Configuration:
Spanning Tree Enabled(Global) :NO
Spanning Tree Enabled(Ports) :YES, 1,2,3,4,5,6,7,8 Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2 Bridge Max Age :20 Root Port :1 Root Path Cost :100 Designated Root :80:00:00:01:96:ed:a7:80 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
-72-
Page 84
MNS-BB Software User Guide
LE2425A(stp)##stp enable Successfully set the STP status
LE2425A(stp)##show stp config
STP Configuration:
Spanning Tree Enabled(Global) :YES
Spanning Tree Enabled(Ports) :YES, 1,2,3,4,5,6,7,8 Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2 Bridge Max Age :20 Root Port :1 Root Path Cost :100 Designated Root :80:00:00:01:96:ed:a7:80 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
To disable STP, just issue the command stp disable under the STP CLI context.
To enable/disable STP by ports, the port port=<number|list|range> status=<enable/disable> is used. An example shows below. LE2425A(stp)##show stp config
STP Configuration: Spanning Tree Enabled(Global) :YES
Spanning Tree Enabled(Ports) :NO
Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2 Bridge Max Age :20 Root Port :0 Root Path Cost :0 Designated Root :80:00:00:20:06:25:00:62 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
LE2425A(stp)##port port=1-8 status=enable Successfully set the STP status for port 1 Successfully set the STP status for port 2 Successfully set the STP status for port 3 Successfully set the STP status for port 4 Successfully set the STP status for port 5 Successfully set the STP status for port 6 Successfully set the STP status for port 7 Successfully set the STP status for port 8
LE2425A(stp)##show stp config
STP Configuration: Spanning Tree Enabled(Global) :YES
Spanning Tree Enabled(Ports) :YES, 1,2,3,4,5,6,7,8
Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2
-73-
Page 85
MNS-BB Software User Guide
Bridge Max Age :20 Root Port :1 Root Path Cost :100 Designated Root :80:00:00:01:96:ed:a7:80 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
LE2425A(stp)##
13.7 Changing STP Bridge Parameter Values
To change bridge priority parameters, the user must be in STP CLI context. Using the command priority value=<0-65535>.
LE2425A(stp)##show stp config
STP Configuration:
Spanning Tree Enabled(Global) :YES Spanning Tree Enabled(Ports) :YES, 1,2,3,4,5,6,7,8
Bridge Priority :32768 Bridge Forward Delay :15 Bridge Hello Time :2 Bridge Max Age :20
Root Port :1 Root Path Cost :100 Designated Root :80:00:00:01:96:ed:a7:80 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20 LE2425A(stp)##priority value=65535
Successfully set the bridge priority
To change bridge STP timing parameters, use the command time forward-delay=<4-30> hello=<1- 10> age=<6-40>.
LE2425A(stp)##time forward-delay=4 hello=1 age=6 Successfully set the bridge time parameters
LE2425A(stp)##show stp config
STP Configuration: Spanning Tree Enabled(Global) :YES Spanning Tree Enabled(Ports) :YES, 1,2,3,4,5,6,7,8
Bridge Priority :65535 Bridge Forward Delay :4 Bridge Hello Time :1 Bridge Max Age :6
Root Port :1 Root Path Cost :100 Designated Root :80:00:00:01:96:ed:a7:80 Designated Root Priority :32768 Root Bridge Forward Delay :15 Root Bridge Hello Time :2 Root Bridge Max Age :20
-74-
Page 86
MNS-BB Software User Guide
13.8 Changing STP Port Parameter Values
To change the STP port priority, use the command priority port=<number|list|range> value=<0­255> under the STP CLI context.
LE2425A(stp)##show stp ports
STP Port Configuration:
----------------------------------------------------------------------------------------------­Port# Type Priority Path Cost State Des. Bridge Des. Port
-----------------------------------------------------------------------------------------------
01 TP(10/100) 128 100 Forwarding 80:00:00:01:96:ed:a7:80 80:20
02 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:02 03 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:03 04 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:04 05 TP(10/100) 128 19 Forwarding ff:ff:00:20:06:25:00:62 80:05 06 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:06 07 TP(10/100) 128 19 Forwarding ff:ff:00:20:06:25:00:62 80:07 08 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:08
LE2425A(stp)##priority port=01 value=50 Successfully set the priority for port 1
To change STP port cost, use the command, use the cost port=<number|list|range> value=<0- 65535>.
LE2425A(stp)##cost port=1 value=200 Successfully set the path cost for port 1
LE2425A(stp)##show stp ports
STP Port Configuration:
---------------------------------------------------------------------------------------------­Port# Type Priority Path Cost State Des. Bridge Des. Port
----------------------------------------------------------------------------------------------
01 TP(10/100) 50 200 Forwarding 80:00:00:01:96:ed:a7:80 80:20
02 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:02 03 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:03 04 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:04 05 TP(10/100) 128 19 Forwarding ff:ff:00:20:06:25:00:62 80:05 06 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:06 07 TP(10/100) 128 19 Forwarding ff:ff:00:20:06:25:00:62 80:07 08 TP(10/100) 128 100 Disabled ff:ff:00:20:06:25:00:62 80:08
13.9 How STP Operates
The switch automatically senses port identity and type, and automatically defines po rt cost and priority for each type. The console interface allows you to adjust the Cost and Priority for each port. It also allows you to adjust the mode for each port and the global STP parameter values for the switch. While allowing only one active path through a network at any time, STP retains any redundant physical path to serve as a backup (blocked) path in case the existing active path fails. Thus, if an active path fails, STP automatically activates (unblocks) an available backup to serve as the new active path for as long as the original active path is down.
13.10 Web: View and Configure STP Parameters
In the web browser interface:
1. Click on the [Configuration].
2. Click on [Port].
3. Click on [Settings].
4. Select a port to modify
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration.
-75-
Page 87
MNS-BB Software User Guide
14.0 Rapid Spanning Tree Protocol (RSTP)
Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w) is an evolution of the Spanning Tree Protocol (STP) (802.1D standard) and provides for faster spanning tree convergence after a topology change.
Use spanning tree protocol to ensure that only one active path at a time exists between any two nodes on the network. In networks where there is more than one physical, active path between any two nodes, enabling spanning tree ensures a single active path between such nodes by blocking all redundant paths. Without spanning tree, having more than one active path between a pair of nodes causes loops in the network, which can result in duplication of messages, leading to a “broadcast storm” that can bring down the network.
Note: User should enable spanning tree operation in any switch that is part of a redundant physical link (loop topology). (It is recommended that you do so on all switches belonging to a loop topology.) This topic is covered in more detail under chapter “Spanning Tree Protocol”.
14.1 How Spanning Tree Operates
The switch automatically senses port identity and type, and automatically defines spanning-tree parameters for each type, as well as parameters that apply across the switch. You can use the default values for these parameters, or adjust them as needed. While allowing only one active path through a network at any time, spanning tree retains any redundant physical path to serve as a redundant (blocked) path in case the existing active path fails. Thus, if an active path fails, spanning tree automatically activates (unblocks) an available redundant to serve as the new active path for as long as the original active path is down.
In the factory default, spanning tree operation is disabled. If a redundant link (loop) exists between nodes in your network, user should enable the spanning tree operation of their choice.
14.3 RSTP Concepts
The 802.1d Spanning Tree Protocol was developed to allow the construction of robust networks that incorporate redundancy while pruning the active topology of the network to prevent loops. While STP is effective, it requires that frame transfer must halt after a link outage until all bridges in the network are sure to be aware of the new topology. Using the Spanning Tree Protocol (IEEE 802.1d) recommended values, this period lasts 30 seconds.
Rapid Spanning Tree Protocol (IEEE 802.1w) is a further evolution of the 802.1d Spanning Tree Protocol. It replaces the settling period with an active handshake between bridges that guarantees topology information to be rapidly propagated through the network. RSTP converges in less than one second. RSTP also offers a number of other significant innovations, including:
• Topology changes in STP must be passed to the root bridge before they can be propagated to the network. Topology changes in RSTP can be originated from and acted upon by any designated bridges, leading to more rapid propagation of address information.
• STP recognizes one state, blocking, for ports that should not forward. RSTP explicitly recognizes two blocking roles, alternate and backup port roles, including them in computations of when to learn and forward.
• STP relays configuration messages received on the root port out its designated ports. If an STP bridge fails to receive a message from its neighbor it cannot be sure where along the path to the root a failure occurred. RSTP bridges generate their own configuration messages, even if they fail to receive one from the root bridge. This leads to quicker failure detection.
• RSTP offers edge port recognition, allowing ports at the edge of the network to forward frames immediately after activation while at the same time protecting them against loops.
• An improvement to age configuration messages more quickly to prevent them from “going around in circles” in the event of a loop.
There are three RSTP states: Discarding, Learning and Forwarding. The discarding state is entered when the port is first taken into service. The port does not learn addresses in this state and does not participate in frame transfer. The port looks for STP traffic in order to determine its role in the network. When it is determined that the port will play an active part in the network, the state will change to Learning. The learning state is entered when the port is preparing to play an active member of the network. The port learns addresses in this state but does not
-76-
Page 88
MNS-BB Software User Guide
participate in frame transfer. In a network of RSTP bridges the time spent in this state is usually quite short. RSTP bridges operating in STP compatibility mode will spend 6 to 40 seconds in this state. After ‘learning’ the bridge will place the port in the forwarding state. The port both learns addresses and participates in frame transfer while in this state.
14.4 Spanning Tree Options: RSTP (802.1w) and STP (802.1D)
14.4.1 RSTP (802.1w)
The IEEE 802.1D version of spanning tree (STP) can take a fairly long time to resolve all the possible paths and to select the most efficient path through the network. The IEEE 802.1w Rapid Reconfiguration Spanning Tree (RSTP) significantly reduces the amount of time it takes to establish the network path. The result is reduced network downtime and improved network robustness. In addition to faster network reconfiguration, RSTP also implements greater ranges for port path costs to accommodate the higher and higher connection speeds that are being implemented. RSTP is designed to be compatible with IEEE 802.1D STP, and Blackbox recommends that you employ it in your network.
14.4.2 STP (802.1D)
The IEEE 802.1D version of spanning tree has been in wide use and can coexist in a network in which RSTP (802.1w) has been introduced. If your network currently uses 802.1D STP and you are not yet ready to implement RSTP, you can apply STP to the switch until such time as you are ready to move ahead with RSTP. STP offers the full range of STP features found in earlier product releases.
14.5 Transitioning from STP to RSTP
IEEE 802.1w RSTP is designed to be compatible with IEEE 802.1D STP. Even if all the other devices in your network are using STP, you can enable RSTP on your switch, and even using the default configuration values, your switch will interoperate effectively with the STP devices. If any of the switch ports are connected to switches or bridges on your network that do not support RSTP, RSTP can still be used on this switch. RSTP automatically detects when the switch ports are connected to non-RSTP devices in the spanning tree and communicates with those devices using
802.1D STP BPDU packets. Because RSTP is so much more efficient at establishing the network path, it is highly recommended that all your network devices be updated to support RSTP. RSTP offers convergence times of less than one second under optimal circumstances. To make the best use of RSTP and achieve the fastest possible convergence times, though, there are some changes that you should make to the RSTP default configuration.
Note Under some circumstances, it is possible for the rapid state transitions employed by RSTP to result in an increase in the rates of frame duplication and disordering in the switched LAN. In order to allow RSTP switches to support applications and protocols that may be sensitive to frame duplication and disordering, setting the Force Protocol Version parameter to STP-compatible allows RSTP to be operated with the rapid transitions disabled. The value of this parameter applies to all ports on the switch.
As indicated above, one of the benefits of RSTP is the implementation of a larger range of port path costs, which accommodates higher network speeds. New default values have also been implemented for the path costs associated with the different network speeds. This can create some incompatibility between devices running the older 802.1D STP and your switch running RSTP.
14.6 Configuring Rapid Reconfiguration Spanning Tree (RSTP) This section describes the operation of the IEEE 802.1w Rapid Spanning Tree Protocol (RSTP).
Note: The default switch configuration has active spanning tree (STP) and disabled.
14.6.1 Optimizing the RSTP Configuration
To optimize the RSTP configuration on your switch, follow these steps
1. Set the switch to support RSTP (STP is the default): Syntax:
2. Save and Reboot the switch.
3. Enable RSTP Spanning Tree
set stp type=rstp
-77-
Page 89
MNS-BB Software User Guide
Syntax: rstp enable
4. Set the “point-to-point” value to off on all ports that are connected to shared LAN segments (that is, to connections to hubs). The default value is auto. Syntax: port port=<number|list|range> p2p= off
5. Set the “edge-port” value to YES for all ports connected to other switches, bridges, and hubs. Syntax: port port=<number|list|range> edge=enable
6. Set the “migration” value to YES for all ports that are connected to devices that are known to be running IEEE 802.1D spanning tree.
Syntax: port port=<number|list|range> migration=enable
14.7 CLI
14.7.1 Main Context Commands
Switch between STP and RSTP
Syntax: set stp type=<stp|rstp> LE2425A# set stp type=rstp
This command sets the current STP to either STP or RSTP.
To see the active STP (STP or RSTP)
Syntax: show active-stp LE2425A# show active-stp
This command shows which one (STP or RSTP) is currently active. e.g., RSTP is currently active.
To see the current configuration
Syntax: show stp config LE2425A#show stp config
To see the current status Syntax: show stp ports LE2425A#show stp ports
14.7.2 RSTP Context Commands
This context contains all the RSTP related commands and can only be executed when RSTP is active. If RSTP is not active, trying to execute these commands will create an error message. Most of the commands are very similar to STP, but may have extra parameters.
-78-
Page 90
MNS-BB Software User Guide
Go to RSTP configuration mode to configure RSTP. Syntax: rstp <enter> LE2425A#rstp <enter> LE2425A(rstp)##
To Enable RSTP (Global)
Syntax: rstp <enable | disable> LE2425A(rstp)## rstp enable This command enables or disables the RSTP globally.
To Enable RSTP (Per Port Basis) Syntax: port port=<number|list|range> [status=<enable/disable>] [migration=<enable|disable>] [edge=<enable|disable>] [p2p=<enable|disable>]
port – a port or list of ports status – enable or disable RSTP on that port(s). migration – enable or disable migration on the port(s). edge - set the current port as an edge port (end station) p2p - set the current port as point to point.
Note: By default all ports are enable for RSTP.
User can disable the specific port for RSTP. LE2425A(rstp)##Port port=15 status=disable
LE2425A(rstp)##show stp ports
To Force the Protocol
Syntax: forceversion <stp|rstp> This command sets the stp or RSTP compatibility mode.
Syntax: show-forceversion User can see the current forced version using this command.
LE2425A(rstp)##show-forceversion Force Version : Normal RSTP
To set cost, priority and timers Syntax: cost port=<number|list|range> value=<0-65535>
This command sets the cost of the port(s). Note on Path Cost RSTP implements a greater range of path costs and new default path cost values to account for higher network speeds. These values are different than the values defined by 802.1D STP as shown below.
Port Type 802.1D STP Path Cost RSTP Path Cost
10 Mbps 100 2000000 100 Mbps 19 200000 1 Gbps 4 20000 10 Gbps 2 2000
Because the maximum value for the path cost allowed by 802.1D STP is 65535, devices running that version of spanning tree cannot be configured to match the values defined by RSTP, at least for 10 Mbps and 100 Mbps ports. In LANs where there is a mix of devices running 802.1D STP and RSTP, you should reconfigure the devices so the path costs match for ports with the same network speeds.
-79-
Page 91
MNS-BB Software User Guide
Syntax: priority [port=<number|list|range>] value=<0-255 / 0-65535>
This command sets the priority to the port(s).
Syntax: timers forward-delay=<4-30> hello=<1-10> age=<6-40>
forward-delay - set forward time delay (4-30 seconds) hello - set hello timer (1-10 seconds) age - set age (6-40 seconds)
Syntax: show-timers This command shows the current timer settings LE2425A(rstp)##show-timers
Forward Delay Timer : 15 sec Hello Timer : 2 sec Max Age : 20 sec
Syntax: show-mode This command shows the ports migration, edge and p2p properties. LE2425A(rstp)##show-mode
You can also see the Port setting of the specific ports. E.g., LE2425A(rstp)##show-mode port=9,15
14.8 Reconfiguring Per-Port Spanning Tree Values
You can configure one or more of the following parameters, which affect the spanning tree operation of the specified ports only:
14.8.1 Per-Port RSTP Parameters Parameter Default Description edge-port Yes
This identifies ports that are connected to end nodes. During spanning tree establishment, these ports transition immediately to the Forwarding state. Disable this feature on all switch ports that are connected to another switch, or bridge, or hub. Use the “no” option on the spanning tree command to disable edge-port.
migration Yes
Ports with migration set to true are forced to send out RSTP BPDUs for 3 seconds. This allows for switches that are running RSTP to establish their connection quickly and for switches running 802.1D STP to be identified. If the whole-switch parameter Force-Version is set to “stp-compatible”, the migration setting is ignored and STP BPDUs are sent out all ports.
path-cost 10 Mbps – 2 000 000 100 Mbps – 200 000 1 Gbps – 20 000 Assigns an individual port cost that the switch uses to determine which ports are the forwarding ports. The range is 1 to 200,000,000 or auto. By default, this parameter is automatically determined by the port type, as shown by the different default values. If you have previously configured a specific value for this parameter, you can issue the command with the auto option to restore the automatic setting feature.
-80-
Page 92
MNS-BB Software User Guide
Please see the Note on Path Cost on page 14-15 for information on compatibility with devices running 802.1D STP for the path cost values.
point-to-point(p2p) Auto
This parameter is used to tell the port if it is connected to a point-to-point link . Default parameter is auto and the switch will automatically set the force-false value on all ports that it detects are not running at full duplex. All connections to hubs are not full duplex. You can also set this parameter to ON, such as to another switch or bridge or to an end node (force- true). This parameter should be set to OFF (force-false) for all ports that are connected to a hub, which is a shared LAN segment.
priority 128
This parameter is used by RSTP to determine the port(s) to use for forwarding.The port with the lowest number has the highest priority. The range is 0 to 240, but you configure the value by entering a multiple of 16. You enter a value in the range 0 - 15. The default value of 128.
-81-
Page 93
MNS-BB Software User Guide
15.0 Port-Based Virtual LANs (Static VLANs)
A VLAN is a group of ports designated by the switch as belonging to the same broadcast domain. (That is, all ports carrying traffic for a particular subnet address would normally belong to the same VLAN.) Note: This section describes static VLANs, which are VLANs you manually configure with a name, VLAN ID (VID), and port assignments. Using a VLAN, you can group users by logical function instead of physical location. This helps to control bandwidth usage by allowing you to group high­bandwidth users on low-traffic segments and to organize users from different LAN segments according to their need for common resources.
By default, the LE2425A and LEV2525 switches are VLAN (Port based) enabled and allow up to 32 VLANs. The port-based nature of the configuration allows interoperation with older switches that require a separate port for each VLAN.
15.1 General Use and Operation
Port-based VLANs are typically used to enable broadcast traffic reduction and to increase security. A group of network users assigned to a VLAN form a broadcast domain that is separate from other VLANs that may be configured on a switch. Packets are forwarded only between ports that are designated for the same VLAN. Thus, all ports carrying traffic for a particular subnet address should be configured to the same VLAN. Cross-domain broadcast traffic in the switch is eliminated and bandwidth is saved by not allowing packets to flood out all ports. An external router is required to enable separate VLANs on a switch to communicate with each other.
15.2 VLAN Support and the Default VLAN
In the factory default configuration, VLAN support is enabled and all ports on the switch belong to the default VLAN (named DEFAULT-VLAN). This places all ports in the switch into one physical broadcast domain. You can partition the switch into multiple virtual broadcast domains by adding one or more additional VLANs and moving ports from the default VLAN to the new VLANs. (The switch supports up to 32 VLANs.) You can change the name of the default VLAN, but you cannot change the default VLAN’s VID (which is always “1”). Although you can remove all ports from the default VLAN, this VLAN is always present.
The LE2425A and LEV2525A Switches Port Based VLAN operate by restricting the broadcast and multicast traffic between the ports. A packet with a broadcast address or with an unknown destination address is forwarded only to ports that share VLAN membership with the source port. Unnecessary repeating of broadcast packets is thus avoided, conserving bandwidth. Packets destined to known addresses are forwarded normally.
Always start all VLANs before editing the default Vlan.
Note:
Syntax: start vlan=all Then, edit id=<vlan Id> [name=<vlan name>] port=<number|list|range>
To display the current VLAN, use the CLI show vlan command.
Syntax: show vlan type=port
15.3 General Steps for Using VLANs
1. Plan your VLAN strategy and create a map of the logical topology that will result from configuring VLANs. Include consideration for the interaction between VLANs.
2. Configure at least one VLAN in addition to the default VLAN.
3. Assign the desired switch ports to the new VLAN(s).
-82-
Page 94
MNS-BB Software User Guide
Notes on Using VLANs
You can rename the default VLAN, but you cannot change its VID (1) or delete it
from the switch.
Any ports not specifically assigned to an other VLAN will remain assigned to the
DEFAULT-VLAN.
Changing the number of VLANs supported on the switch requires the SAVE
command.
15.4 CLI: Configuring VLAN Parameters
In the factory default state, all ports on the switch belong to the default VLAN (DEFAULT-VLAN) and are in the same broadcast/multicast domain. You can configure up to 31 additional static VLANs by adding new VLAN names, and then assigning one or more ports to each VLAN. (The switch accepts a maximum of 32 VLANs, including the default VLAN ).
NOTE: LE2425A and LEV2525A support one type of VLAN at a time. The user has to set the VLAN type before configuration.
Steps:
To set the type of Vlan that you are going to use.
Syntax: set vlan type=<port|tag|none>
LE2425A#set vlan type=port VLAN set to Port-based.
Go to Configuration mode
Syntax: configure vlan type=port OR vlan type=port LE2425A#vlan type=port LE2425A(port-vlan)##
Add VLAN
Syntax: add id=<vlan Id> [name=<vlan name>] port=<number|list|range>
LE2425A(port-vlan)## add id=2 name=test port=1-10
Start Vlan
Syntax: start vlan=<name|number|list|range> LE2425A(port-vlan)## start vlan=all
Save the configuration
Syntax: save
LE2425A(port-vlan)##save
Saving current configuration...
Configuration saved
15.4.1 Displaying the Switch’s VLAN Configuration.
The next command lists the VLANs currently running in the switch, with VID, VLAN name, and VLAN status. LE2425A# show vlan type=port
VLAN ID : 1 Name : Default VLAN Status : Active
======================== PORT | STATUS ======================== 1 | DOWN 2 | DOWN 3 | DOWN 4 | DOWN 5 | DOWN 6 | DOWN
-83-
Page 95
MNS-BB Software User Guide
7 | DOWN 8 | DOWN 25 | DOWN
VLAN ID : 2 Name : Engg Status : Active
======================== PORT | STATUS ======================== 9 | UP 10 | DOWN 11 | DOWN 12 | DOWN 13 | DOWN 14 | DOWN 15 | DOWN 16 | DOWN 17 | DOWN 18 | DOWN
VLAN ID : 3 Name : Mktg Status : Active
======================== PORT | STATUS ======================== 18 | DOWN 19 | DOWN 20 | DOWN 21 | DOWN 22 | DOWN 23 | DOWN 24 | DOWN
15.4.2 Displaying the Configuration for a Particular VLAN
This command uses the VID to identify and display the data for a specific static VLAN.
Syntax: show vlan type=port [<id=vlanid>]
LE2425A# show vlan type=port id=2
VLAN ID : 2 Name : Engg Status : Active
======================== PORT | STATUS ======================== 9 | UP 10 | DOWN 11 | DOWN 12 | DOWN 13 | DOWN 14 | DOWN 15 | DOWN 16 | DOWN 17 | DOWN 18 | DOWN
15.5 Creating a New Static VLAN
15.5.1 Changing the VLAN Context Level.
With this command, entering a new VID creates a new static VLAN. Entering the VID or name of an existing static VLAN places you in the context level for that VLAN.
Syntax: add id=<vlan Id> [name=<vlan name>] port=<number|list|range>
-84-
Page 96
MNS-BB Software User Guide
This command creates a new static VLAN (if a VLAN with that VID does not already exist) and places you in that VLAN’s context level. If you do not use the name option, the switch uses “ VLAN” and the new VID to automatically name the VLAN. If the VLAN already exists, the switch places you in the context level for that VLAN. For example, to create a new static VLAN with a VID of 32: LE2425A(vlan-port)## add id=32 name=Fin port=10,11,12 Port vlan added successfully
LE2425A# show vlan type=port id=32
VLAN ID : 32 Name : Fin Status : Pending
======================== PORT | STATUS ======================== 10 | DOWN 11 | DOWN 12 | DOWN
To enable the new VLAN type the following: LE2425A(vlan-port)## start vlan =<ID or port list> For example, LE2425A(vlan-port)## start vlan = 32 Resulting,
VLAN ID : 32 Name : Fin Status : Active
======================== PORT | STATUS ======================== 10 | DOWN 11 | DOWN 12 | DOWN
15.6 Effect of VLANs on Other Switch Features
15.6.1 VLAN Restrictions
A port must be a member of at least one VLAN. In the factory default configuration, all ports are
assigned to the default VLAN (DEFAULT-VLAN; VID = 1).
Before you can delete a VLAN, you can optionally re-assign all ports in the VLAN to another VLAN.
Ports that are members of other VLANs will retain these memberships while all other ports will fall back into the default VLAN.
The LE2425A and LEV2525A switches support port based VLANs. Each port is configured to be
member of one or more VLANs. A port can communicate with another port only if both the ports share membership in the same VLAN. A specific port can be a member of more than one VLAN.
Note: Since the higher-level network protocols rely upon broadcasts to discover network addresses of other stations, normal communication will not be possible between ports with no common VLAN membership. However, it is sometimes possible to send a frame to another port if the destination address is known. This happens since the switching hardware filters packets that are to be broadcast.
15.7 Web: Viewing and Configuring VLAN Parameters
In the web browser interface you can do the following:
Add VLANs
Rename VLANs
Remove VLANs
Configure GVRP security
Select a active VLAN
15.7.1 To configure static VLAN port parameters
1. Click on the [Configuration] tab.
-85-
Page 97
MNS-BB Software User Guide
2. Click on [VLAN].
3. Click on desired VLAN, Port or Tag.
4. Click on [Add/Delete] button.
5. After you make the desired changes, click on [OK] button.
6. Click [Save] to save the configuration. For web-based Help on how to use the web browser interface screen, click on the [Help] button provided on the web browser screen.
16.0 TAG Based VLAN
16.1 Introduction
TAG based VLANs are used to filter packets arriving at a particular po rt or set o f ports. Th e filtering
-86-
Page 98
MNS-BB Software User Guide
is based on the TAG information contained in the packet. Hence, we can drop or allow through packets arriving on a set of ports based on the source TAG information contained in the packets.
16.2 VLAN Tagging Information
VLAN tagging enables traffic from more than one VLAN to use the same port. (Even when two or more VLANs use the same port they remain as separate domains and cannot receive traffic from each other without going through an external router.) As mentioned earlier, a “tag” is simply a unique VLAN identification number (VLAN ID, or VID) assigned to a VLAN at the time that you configure the VLAN name in the switch. In the LE2425A and LEV2525A switches, the tag can be any number from 1 to 4095 that is not already assigned to a VLAN. When you subsequently assign a port to a given VLAN, you must implement the VLAN tag (VID) if the port will carry traffic for more than one VLAN. Otherwise, the port VLAN assignment can remain “untagged” because the tag is not needed. On a given switch, this means you should use the “Untagged” designation for a port VLAN assignment where the port is connected to a non 802.1Q-compliant device or is assigned to only one VLAN. Use the “Tagged” designation on at least one of the VLAN’s when the port is assigned to more than one VLAN or the port is connected to a device that does comply with the 802.1Q standard.
Ports 1-6: Untagged Port 7: Red VLAN Untagged Green VLAN Tagged
Ports 1-4: Untagged Port 5: Red VLAN Untagged
Example of Tagged and Untagged VLAN Port Assignments
For example, if port 7 on an 802.1Q-compliant switch is assigned to only the Red VLAN, the assignment can remain “untagged” because the port will forward traffic only for the Red VLAN. However, if both the Red and Green VLANs are assigned to port 7, then at least one of those VLAN assignments must be “tagged” so that Red VLAN traffic can be distinguished from Green VLAN traffic. The above illustration shows this concept.
¾ In switch X:
Suppose the ports X1 - X6 each only have one VLAN per port. The VLANs assigned can all be
untagged. Red VLAN traffic will go out only the Red ports; Green VLAN traffic will go out only the Green ports, and so on. Devices connected to these ports do not have to be 802.1Qcompliant.
However, if both the Red VLAN and the Green VLAN are assigned to port X7, at least one of the
VLANs must be tagged for this port.
-87-
Page 99
MNS-BB Software User Guide
¾ In switch Y:
VLANs assigned to ports Y1 - Y4 can all be untagged if there is only one VLAN assignment per port.
Devices connected to these single VLAN ports do not have to be 802.1Q-compliant.
If both the Red VLAN and the Green VLAN are assigned to port Y5, at least one of the VLANs must
be tagged for this port. In both switches: The ports on the link between the two switches must be configured the same. Referring to figure 9-54 (above), the Red VLAN can be untagged on port X7 and Y5 and the Green VLAN can be tagged on port X7 and Y5, or vice-versa if the Red and Green VLAN’s are both on the link.
Note: Each 802.1Q-compliant VLAN must have its own unique VID number, and that VLAN must be given the same VID in every device in which it is configured. That is, if the Red VLAN has a VID of 10 in switch X, then 10 must also be used for the Red VID in switch Y.
VLAN tagging gives you several options:
Since the purpose of VLAN tagging is to allow multiple VLANs on the same port, any port that has
only one VLAN assigned to it can be configured as “Untagged” (the default).
Any port that has two or more VLANs assigned to it can have one VLAN assignment for that port as
“Untagged”. All other VLANs assigned to the same port must be configured as “Tagged”. (There can be no more than one Untagged VLAN on a port.)
If all end nodes on a port comply with the 802.1Q standard and are configured to use the correct VID,
then, you can configure all VLAN assignments on a port as “Tagged” if doing so makes it easier to manage your VLAN assignments, or for security reasons.
16.3 Rules of Tag Vlan Operation
After you select a VLAN mode for the system and create VLAN interfaces with VLAN characteristics such as IEEE 802.1Q or no tagging and port membership, the system determines the details of VLAN operation by observing two main types of rules:
Ingress rules - Assign an incoming frame to a specific VLAN.
Egress rules - Use standard bridging rules to determine whether the frame is forwarded, flooded,
or filtered. These rules also determine the tag status of the transmitted frame.
These rules are classified in the IEEE 802.1Q standard. In addition, the system relies on some system­specific rules.
16.3.1 Ingress Rules
These rules determine the VLAN to which an incoming frame belongs. The frame is assigned to the VLAN that matches most closely. A protocol match hierarchy is used to find the most specific match. The ingress rules, which are classified according to your VLAN mode, use the following process to determine the most specific match:
1 . IEEE 802.1Q tag VID value 2 . The default VLAN (an untagged VLAN with all ports and a VID of 1), or any port-based VLAN
Ingress Rules for VLANs
If the frame is an IEEE 802.1Q tagged frame, the frame is assigned to the VLAN if the VID of
the frame matches that of the VLAN. If there is no VID match, the frame is dropped.
If the frame is not tagged, the frame is assigned to the VLAN if the receive port is untagged (that
is, if tagging is set to none) and if the receive port of the frame matches that of the VLAN. If there is no match, the frame is dropped.
16.3.2 Egress Rules
These rules determine whether the outgoing frame is forwarded, filtered (dropped), or flooded; they also determine the frame's tag status. The frame is forwarded out of the port in the VID 2 VLAN (where the address is known) and with the tag status of that port.
Standard Bridging Rules for Outgoing Frames
The frame is handled according to these bridging rules: If the transmit port is tagged and is not a member of the assigned VLAN, the frame is dropped. If the frame's destination address matches an address that was learned on the receive port, it is filtered (dropped).
-88-
Page 100
MNS-BB Software User Guide
If the frame's destination address matches an address that was learned on a port other than the receive port, it is forwarded to that port. If a frame with an unknown, multicast, or broadcast destination address is received, then it is flooded (that is, forwarded to all ports on the VLAN that is associated with the frame, except the port o n which it was received). If the frame's destination address matches a MAC address of one of the bridge's ports, it is further processed, not forwarded immediately. This type of frame is a management/configuration frame, such as a SNMP get/set PDU, Administration Console Telnet packet, or a Web Management Interface http packet.
Tag Status Rules
After the VLAN and the transmit ports are determined for the frame, the tag status rules determine whether the frame is transmitted with an IEEE 802.1Q tag:
For each port on which a frame is to be transmitted, if that port is tagged for the VLAN that is
associated with the frame, transmit the frame as a tagged frame.
For each port on which a frame is to be transmitted, if that port is not tagged for the VLAN that is
associated with the frame, transmit the frame as an untagged frame
16.4 CLI
LE2425A and LEV2525A Switches support one type of VLAN at a time. The user has to set the VLAN type before configuration. LE2425A# set vlan type=<port|tag|none> For Tag VLAN, LE2425A# set vlan type=tag
Than, go to Vlan configuration mode by typing, LE2425A# vlan type=tag
To add a TAG based VLAN we use the following command: LE2425A(tag-vlan)## add id=<vlan Id> [name=<vlan name>] port=<number|list|range> where,
id is a valid VLAN ID. Its value has to be between 1 and 4095. name is an optional field which is used to name a VLAN. port is a valid range/list of ports or a single port which is to be add ed to the VLAN.
Note: When a new TAG VLAN is added, the VLAN’s state is set to ‘pending’, to activate the VLAN, use the start command described below.
To delete a TAG VLAN use the following command: LE2425A(tag-vlan)## delete vlan=<name|number|list|range> where,
vlan is the name or VLAN ID which is to be deleted.
This field also accepts range of VLAN ID values. Note: An active VLAN cannot be deleted. The VLAN has to be stopped before it can be deleted. Only VLAN’s in pending state can be deleted.
To edit/change the VLAN settings use the following command: LE2425A(tag-vlan)##editid=<vlanId>[name=<vlanname>] port=<number|list|range> where,
id is an exisiting VLAN ID. name is an optional field which is the name of the VLAN. port is valid range/list of ports or a single port.
Note: An active VLAN cannot be edited. The VLAN has to be stopped before it can be edited. Only VLAN’s in pending state can be edited.
To start/activate a VLAN use the following command: LE2425A(tag-vlan)## start vlan=<all|name|number|list|range> where,
vlan is the name or VLAN ID which is to be started/activated. This field also accepts range of VLAN ID values. To activate all the ‘pending’ VLAN’s, use ‘all’ instead of VLAN ID’s or VLAN name.
-89-