Black Box LBS216AE-R3 User Manual

Page 1
16 Ports Nway Fast Ethernet Switch
User’s Manual
Page 2
2
FCC Warning
This device has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and radiates radio frequency energy and, if not installed and used in accordance with the user’s manual, may cause interference in which case user will be required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user many be required to take adequate measures.
Page 3
3
Table Of Contents
Chapter 1 ............................................................................................1
Introduction ....................................................................................1
Key Features ...................................................................................2
Chapter 2 ...........................................................................................3
Package Contents ............................................................................3
Chapter 3 . ..........................................................................................4
Front Panel Layout .......................................................................4
A. 16 RJ-45 10/100Mbps Switch Ports ....................................4
B. LED Indicators Of 16 Port 10/100Mbps Switch .................4
C. LED Definitions ..................................................................4
Power LED ....................................................................4
10/ 100M LED …………..……………………..………4
Link/ACT LED ……………………………………..….4
Real Panel Layout .........................................................................5
A. AC Input ..............................................................................5
Chapter 4 . ..........................................................................................5
Rack Mounting ............................................................................... 5
Chapter 5 . ................................................................................. 6
Installation ...................................................................................... 6
A. How to connect the Switch to PCs, servers, and other network
devices ..............................................................................6
B. How to Up-Link the Switch to a Switch or a Hub ............7
Chapter 6 ...........................................................................................8
Technical Specifications ...............................................................8
Appendix ………………………………………………………... ...10
A. ANSI/TIA/EIA-568-A PLUG & Twisted-pair Cable ........ 10
B. EIA568A pin assignment ...................................................10
C. Recommend CAT5 UTP specifications .............................10
Page 4
-1-
Chapter 1
.
16 Ports Nway Fast Ethernet Switch
Introduction
The Switch provides 16 10/100Mbps ports. It was designed for easy installation and high performance in an environment where traffic on the network and the number of user increasing continuously.
The 19-inch standard rack-mount size was specifically designed for ROBO (Remote Office & Branch Office) and medium to large workgroups. The Switch can be installed where space is limited; moreover it provides smooth network migration and easy upgrade to network capacity.
Page 5
2
Key Features
16 Ports 10/100Base-T/TX Auto-negotiation and
Auto-MDIX Switch. Built-in storage of 8K MAC addresses. 19-inch Rack-mount size 1 U high design. Support Auto MDIX crossover capabilities.
Broadcast storm control Store & Forward switching methods Flow control fully supported:
Half-duplex mode Æ back-pressure flow control.
Full duplex mode Æ 802.3x pause frame flow control.
Provided Non-blocking & Non-head-of-line blocking full
wire speed forwarding.
Auto-learning of networking configurations Provided front panel reset button Status LEDs: Power, 10/100M, Link/Activity And
Full/Half-duplex
Smart plug & play
Page 6
3
Chapter 2
Package Contents
Before you start to install the Switch, please verify your package that contains the following items:
One Fast Ethernet Switch
Rack-mount Kit For Rack Installation
One Power Cord
One User’s Manual
Note: If any of these items is found missing or damaged, please contact your local supplier for replacement.
Page 7
4
Chapter 3
Front Panel Layout
A. 16 RJ-45 10/100Mbps Switch Ports
There are 1~16 RJ-45 connectors on the front panel for connecting to servers, workstation or other network devices. The Switch provides 16 10/100Mbps switching ports that could sense the 10/100M speed and negotiate Full/Half-duplex mode automatically. These switching ports allow users connect the Switch to 10Base-T and 100Base-TX devices.
B. LED Indicators of 16 Port 10/100Mps Switch
LED Color Status Description No. Of LED
Power Yellow On Power on 1
On Port is on the 100M status 16 (1~16) 10/100M Green Off Port is on the 10M status 16 (1~16) On 10/100Mbps port for connection 16 (1~16) LINK/ACT. Green Flashing 10/100Mbps for data activating 16 (1~16)
C. LED Definitions
Power LED
On The unit is powered on and ready for use. Off The unit is powered off.
10/100M LED
On The port is on the 100Mbps status. Off The port is on the 10Mbps status.
LINK/ACT LED
On The port is ready for 10/100Mbps connection. Flashing The data is transmitted or received on the port.
Page 8
5
Rear Panel Layout
A AC input.
AC input (90-260V/AC, 50-60Hz) UL Safety.
Chapter 4
Rack Mounting
Optional Rack-mounting brackets are available to mount Switch in standard EIA 19-inch rack. 16 port 10/100Mbps Switch is supplied with two mounting brackets and eight screws. And please assemble according to the following steps. First, put the Switch on the flat surface. Locate the mounting brackets on the sides of the Switch with the mounting holes on each. Next, insert the screw through the bracket and into the bracket mounting holes in the Switch. Then, place the Switch in to 19-inch rack.
Page 9
6
Chapter 5
Installation
Note: The Switch supports the AUTO-MDIX function. Just make sure
the twisted-pair cables meet the ANSI/EIA/TIA 568A(straight-through) or 568B(crossover) specification.
A. How to connect the Switch to PCs, servers, and other network
devices
Connect straight-through twisted-pair cable (Cat. 5) to the Switch and PCs, servers and other network devices. Then the network environment can be built easily as the following figure showed.
Page 10
7
B. How to UP-Link the Switch to a Switch or a Hub
Use CAT5 twisted pair cable to connect the Switch to another Switch or Hub on any port. Don’t worry about to use straight-through cable or crossover cable. The switch support AUTO-MDIX on all port.
Chapter 6
Page 11
8
Technical Specifications
1. Standards Compliance
- IEEE 802.3 10BASE-T; IEEE 802.3u 100BASE-TX
2. Number Of Ports
- 16 integrated ports (10/100Mbps Nway port)
3. Fully Flow Control Supported
- Half-duplex mode: Backpressure
- Full-duplex mode: IEEE 802.3x
4. Network Transmission Media
- 10Base–T Cat. 3, 4, 5 UTP/STP
- 100Base–TX Cat. 5 UTP/STP
5. Network Status Monitoring LEDs
- Per port: LINK/ACT, 10/100M
- System: POWER
6. Buffer Memory
- RAM: 4M bits per device
- RAM buffer dynamically allocated for each port
7. Filter/Forward Rate
- Packet Filtering/ Forwarding Rates (64Bytes)
-100Mbps port - 148,800pps
-10Mbps port - 14,880pps
8. MAC Address
- Up to 8K per device
9. Power
- AC input (90-260V/AC, 50-60Hz) UL Safety
10. Power Consumption
- 15 Watts (Max)
11. Operating Temperature
- 0~ 60
12. Store Temperature
- -20~ 90
Page 12
9
13. Humidity
- 10% ~90% RH (Non-condensing)
14. Dimension (L × W × H)
- 440mm × 220mm × 44mm
15. Weight
- 2.5Kg
16. Safety & EMI Certificates
- CE & FCC-A
Page 13
10
Appendix
A. ANSI/TIA/EIA-568-A PLUG & Twisted-pair Cable
The IEE802.3u Standards permits the use of category 3, 4, 5 or better balanced cable pairs, installed according to ANSI/EIA-568-A. This appendix provides pinout and brief information for the CAT5 unshielded twisted pair cables . B. EIA568A pin assignment:
Pin Number Assignment
1 2
Plus data transmission (Pair 3)
Minus data transmission (Pair 3)
3 6
Plus data receiver (Pair 2)
Minus data receiver (Pair 2)
4 5
Not used by 10BASE-T and
100Base-TX (Data pair 1)
7 8
Not used by 10BASE-T and
100Base-TX (Data Pair 4)
C. Recommend CAT5 UTP specifications
Physical:
FR-PVC cable construction Cable Type: 4-pair unshielded-twisted pair solid copper Conductors: 24 AWG, solid bare annealed copper Operating temperature: -20 0C to +75 0C
Electrical:
Impedance: 100 ±15 % Near-End Cross-talk: 38dB @ 100 MHz Attenuation: 22 dB/100 m typical @ 100 MHz Maximum DC resistance : 9.38 / 100 m (24 AWG) at 200C Maximum DC insulation resistance 150M/km
Page 14
11
DOC-UMWR240X001
Loading...