Black Box LB9007A-SC-R3 User Manual

October, 2003
Express Ethernet Switch
LB9007A-SC-R3
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com
Express Ethernet Switch LB9007A-SC-R3
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
RADIO FREQUENCY INTERFERENCE STATEMENT
Normas Oficiales Mexicanas (NOM)
INSTRUCCIONES DE SEGURIDAD
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
2
Express Ethernet Switch LB9007A-SC-R3
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
3
Express Ethernet Switch LB9007A-SC-R3
About This Manual
This manual describes the Black Box Express Ethernet Switch LB9007A-SC-R3 in these basic sections:
Product Features
Installation
Product Features
This section examines the key features, the physical features, and the product specifications of each model.
Installation
This section leads with a Quick Tip, and continues with a detailed description of Connecting to Power and Connecting to Your Network with the two types of cable: copper-based and fiber-optic. The section concludes with instructions on using the Uplink Function.
4
Express Ethernet Switch LB9007A-SC-R3
Table of Contents
About This Manual .......................................................................................4
Packing List ...................................................................................................6
Introduction...................................................................................................6
Product Features .................................................................................................................6
Front Panel .........................................................................................................................7
LEDs...................................................................................................................................7
Installation.....................................................................................................8
Selecting a Site for the Switch............................................................................................8
Connecting to Your Network .............................................................................................8
Specifications.................................................................................................9
5
Express Ethernet Switch LB9007A-SC-R3
Packing List
The switch
User’s manual
One AC power cord
Introduction
Designed in reliable metal case, LB9007A-SC-R3 is a compact size Fast Ethernet switch that has 7 ports 10/100Base-TX plus 1 port FX with multi-mode SC connector. It is the internal power supply version of LB8418A.
By using standard auto-negotiation and the inclusion of Auto-MDIX, LB9007A-SC-R3 provides a cost-effective way of integrating legacy 10Mbps with 100Mbps networks while eliminating problems arises from cabling difficulties. Auto-sensing MDI/MDIX allows every TX port on LB9007A-SC-R3 automatically detect the Ethernet cable type (straight or crossover) being used and make adjustment to link over that cable to another PC, switch or hub.
Fiber ports on LB9007A series accommodate various requirements on your network environment. Products equipped with multi-mode SC or ST connectors are listed as LB9007A-SC-R3 & LB9007A-ST-R3 respectively. MT-RJ, VF-45, LC and single mode fiber connectors with various distances are available through special order. Please contact customer support at 724-246-5500 for more information.
The bridging function of LB9007A series provides a solution for extending the distance between two networks segments. The non-blocking switching architecture satisfies the great demand in multimedia and imaging applications. LB9007A series meets a variety of installation requirements. It is an economical solution providing multimedia networking with space conservation.
Product Features
7 ports 10/100BaseTX & 1 port 100Base multi-mode FX with SC connector
All TX ports are auto-MDIX, auto-negotiation on 10/100Mbps speed and full/half
duplex mode
Broadcast storming filter function
True non-blocking architecture
Full wire-speed forwarding rate
Store-and-forward mechanism
Back pressure and IEEE802.3x compliant flow control
Supports 2K MAC addresses
Supports 1M bits buffer memory
Front panel power and port status LEDs
Space saving compact size
6
Express Ethernet Switch LB9007A-SC-R3
Front Panel
The front panel of LB9007A-SC-R3 has eight ports and an array of LED indicators to provide you with instant feedback on the status of the switch.
LEDs
The array of LED indicators on the front panel conveys status and configuration information to help you monitor and troubleshoot the switch.
Figure 1: Front panels
n Power: This LED comes on when the switch is connected to the power.
o Port Status: Each port has a LED, indicating the port status.
p SC Fiber Port: The distance of the multi-mode fiber is up to 2KM.
Table 1: Port Status
LED State Indication
LNK/ACT
Power Port Status SC Fiber Port
The port has established a valid network connection.
Steady
LNK stands for LINK.
The port is transmitting or receiving data.
Flashing
ACT stands for ACTIVITY.
7
Express Ethernet Switch LB9007A-SC-R3
Installation
Selecting a Site for the Switch
As with any electronic device, you should place the switch where it will not be subject to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to
40 degrees Celsius). The relative humidity should be less than 90 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for IEC 801-3, Level 2 (3V/M) field strength. Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on the side of the switch or the fan exhaust port on the rear of the switch. The power outlet should be within 1.8meter (6 feet) of the switch.
Connecting to Your Network
Connect network cables from computers or network segments to the TX ports on the unit.
Table 2: Cabling Information
Speed Connector Port Speed
Half/Full Duplex
100BaseTX RJ-45 100/200 Mbps
10BaseT RJ-45 10/20 Mbps
100BaseFX
Multi-mode
100BaseFX
Single-mode
SC, ST, MT-RJ,
VF-45, or LC
SC 100/200 Mbps
100/200 Mbps
100 m, Category 5 STP/UTP
100 m, Category 3, 4, or 5 STP/UTP
Up to 2km, 50 or 62.5/125µm Multi­mode fiber cable
Up to 75km, 9 or 10/125µm Single­mode fiber cable
Cable
8
Specifications
Express Ethernet Switch LB9007A-SC-R3
Applicable Standards
LED Indicators
Cable
Switching Methods
Forwarding Rate
AC Input
Power consumption
Operating Temperature
Storage Temperature
IEEE 802.3, 10BaseT,
IEEE 802.3u, 100BaseTX/FX
Per unit – Power Status
Per Port – LNK/ACT
10BaseT 2-pair UTP/STP Cat. 3,4,5, up to 100m
100BaseTX 2-pair UTP/STP Cat.5, up to 100m
100BaseFX 50 or 62.5/125µm Multi-mode fiber optic cable, up to 2km
100BaseFX 9 or 10/125µm Single-mode fiber optic cable, up to 75km
Store-and-Forward
14,880pps for 10Mbps,
148,800pps for 100Mbps
100~240VAC, 50-60Hz
3.3VDC, 2.5A, 8.25W max.
0°C~40°C (32°F~104°F)
-25°C~70°C (-13F°~158°F)
Humidity
Emissions
Dimensions
Weight
10%~90%, non-condensing
FCC part 15 Class A, CE Mark
W254 x D135 x H35mm compact size
1.6kg (3.5lb.)
9
Loading...