Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENT
Class B Digital Device. This equipment has been tested and found to comply with the limits for a
Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular installation. This equipment generates, uses,
and can radiate radio frequency energy, and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. If this equipment does cause
harmful interference to radio or telephone reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult an experienced radio/TV technician for help.
Caution:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
To meet FCC requirements, shielded cables and power cords are required to connect this device to a
personal computer or other Class B certified device.
Express Ethernet Switch
This digital apparatus does not exceed the Class B limits for radio noise emission from digital
apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la classe B prescrites dans le Règlement sur le brouillage radioélectrique
publié par le ministère des Communications du Canada.
Normas Oficiales Mexicanas (NOM)
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato
eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser
respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño,
lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean
recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el
fabricante.
2
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en
las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio
calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La
colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede
bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire
por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores,
registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el
instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no
sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni
pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los
contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del
fabricante.
Express Ethernet Switch
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo
periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la
cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
3
Preface
This manual describes how to install and use the provided Ethernet switch, which
features two ports that automatically sense the presence of 100Mbps or 10Mbps
Ethernet networks. 100BASE-FX fiber ports are also available for this product
series.
To get the most out of this manual, you should have an understanding of
networking concepts such as bridges, IEEE 802.3 10BASE-T Ethernet and
100BASE-TX Fast Ethernet, and local area networks (LANs).
Appendix A - Connector Pinouts.......................................................................................11
Figure 7: RJ-45 Connector and Cable Pins...................................................................... 12
Express Ethernet Switch
5
Introduction
Product Features
This switch provides following features:
♦ 1x 10/100TX and 1x 100FX port
♦ Full-duplex and half-duplex capability on TX ports.
♦ Auto-negotiation for speed and Auto-MDIX on TX port.
♦ Compliance with IEEE802.3, 10Base-T, IEEE802.3u, 100Base-TX
and 100Base-FX standards.
♦ Comprehensive array of LED indicators that communicate the status
of the switch and troubleshooting information.
♦ Features store-and-forward architecture with wire-speed filtering and
forwarding rates.
♦ Dynamic learning mode automatically adjusts to the network
configuration.
♦ Runt and CRC filtering eliminates erroneous packets to optimize
network bandwidth.
♦ Full compatibility with standard Ethernet applications,
internetworking systems and client-side adapters to minimize
migration costs.
Express Ethernet Switch
6
Express Ethernet Switch
Packing List
When you unpack the switch, you should find the items listed below. Please
inspect the contents, and report any apparent damage or missing items
immediately to your authorized reseller.
• The two-port Ethernet switch
• User's Manual
• AC power cord
Front Panel
The front panel of this switch has two ports and an array of LED indicators to
provide you with instant feedback on the switch
status.
Figure 1: Front panel of the 10/100TX and 100FX Switch
Ports
The TX port of this switch is capable of accepting either a 10BASE-T or a
100BASE-TX network. It automatically senses and adapts itself to the
presence of either network standard. The fiber port on the Ethernet switch is
capable of accepting 100Base-FX connections only.
Cable Length
The maximum distance between a node and a directly connected switch port
on a 100BASE-TX network is 100 meters with Category 5 shielded twistedpair (STP) cable or unshielded twisted-pair (UTP) cable. On a 10BASE-T
network, it may range up to 100 meters with Category 3, 4, or 5 STP/UTP
cable.
As for the length of fiber connection between a switch and a Data Terminal
Equipment, it is capable of spanning at most 2 kilometers (1.24 miles) using
62.5/125 µm multi-mode fiber-optic cable or up to 75 kilometers using
10/125 µm single-mode fiber optic cable.
Table 3: Cable Specifications
7
Express Ethernet Switch
Speed Connect
100BaseTX RJ-45 100/200
10BaseT RJ-45 10/20 Mbps 100 m, Category 3, 4,
100BaseFX
Multi-mode
100BaseFX
Single-mode
or
SC, ST,
MT-RJ,
VF-45, or
LC
SC 100/200
Port Speed
Half/Full
Duplex
Mbps
100/200
Mbps
Mbps
Cable
100 m, Category 5
STP/UTP
or 5 STP/UTP
Up to 2km, 50 or
62.5/125µm Multimode fiber cable
Up to 75km, 9 or
10/125µm Single-mode
fiber cable
LEDs
The array of LED indicators on the front panel conveys status and
configuration information to help you monitor and troubleshoot the switch.
Figure 2: LED Indicators
8
n Port Status
There are two LED ( LNK/ACT, FDX/COL ) for 100Base-FX port and three
LED ( LNK/ACT, FDX/COL, SPEED ) for 10/100Base-TX port to show
status information. The LEDs are identified by a corresponding array of
captions located above and below the LEDs on the front panel.
LNK/ACT:
There are two LNK/ACT LEDs on the front panel:
The LED next to TX port indicates status on TX port, and the one next to
FX port indicates status on FX port.
When the LED is illuminating whenever the port is connected to another
working networked device and flashing when the port is transmitting or
receiving data.
FDX/COL:
There are two FDX/COL LEDs on the front panel:
The LED next to TX port indicates status on TX port, and the one next to
FX port indicates status on FX port.
The LED is illuminating when the port is operating in full-duplex mode. The
LED is off when the port is operating in half-duplex mode.
The LED is flashing when the switch detects packet collisions on the port.
Express Ethernet Switch
100:
The low-right LED is illuminating whenever the switch detects the TX port
is connected to a 100BASE-TX segment. The LED is off when the TX port
is connected to a 10BASE-T segment.
9
o Power
This LED will be on when the switch is connected to a power supply and turned on.
Rear Panel
The power cord receptacle and on/off switch is located on the rear panel of
the switch.
Figure 3: Rear Panel
Installation
Express Ethernet Switch
This chapter presents step-by-step installation instructions for the two-port
switch.
Selecting a Site for the Switch
As with any electronic device, you should place the switch where it will not
be subjected to extreme temperatures, humidity, or electromagnetic
interference. Specifically, the site you select should meet the following
requirements:
• The room temperature should be between 32 and 104 degrees Fahrenheit
(0 to 40 degrees Celsius).
• The relative humidity should be less than 90 percent, non-condensing.
• Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
• Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on the side of the switch or the fan exhaust port at the
rear of the switch.
• The power outlet should be within 1.8 Meters of the switch.
Detailed specifications may be found on page 11.
Connecting to Power
Connect the supplied AC power cord to the receptacle on the back of the
switch, and then plug the cord into a standard AC outlet with a voltage range
from 100 to 250 AC.
10
Express Ethernet Switch
Turn the Ethernet switch on by flipping the ON/OFF switch on the rear of
the unit to the I (ON) position. The O position is OFF.
Connecting to Your Network
Connect cables to computers or network segments into the RJ-45 ports on
the front of this switch. The non-fiber ports support 10BASE-T or
100BASE-TX with full or half duplex. The fiber port on the switch supports
100BASE-FX with full or half duplex.
The cable for RJ-45 ports must be a Category 5 unshielded twisted-pair (
UTP) cable for 100BASE-TX, or Category 3, 4, or 5 UTP cable for
10BASE-T. The cable for fiber port must be a 62.5/125 micron fiber-optic
cable for 100BASE-FX.
Specifications
Applicable Standards:
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX, 100Base-FX
Ports
one 10/100TX auto-negotiation port and one 100Base-FX port