Black Box LB532A-M User Manual

Page 1
LB532A-M
DeeSel.1 Industrial Ethernet Extender Multi-Drop Unit, G-SHDSL 2-Wir e, 5.7 Mbps
Get multi-drop Ethernet extension over twisted pair with distances of 4.3 miles per hop.
Page 2
724-746-5500 | blackbox.com
Black Box Ethernet Extenders
TABLE OF CONTENTS
1. General Information .....................................................................................9
1.1 Features ..............................................................................................9
1.2 Description.......................................................................................... 9
1.3 Power Input Connector....................................................................... 9
2. Configuration............................................................................................. 10
2.1 Hardware (DIP-switch) Configuration ...............................................10
2.2 DIP Switch Settings.......................................................................... 11
DIP Switch Settings: Data Rate ............................................. 11
Ethernet Management Port.................................................... 14
3. Installation.................................................................................................. 16
3.1 Connecting the Interface ...................................................................16
3.2 Connecting the Ethernet Interface.................................................... 17
3.3 Connecting external AC universal power supply.............................. 18
4. Operation................................................................................................... 19
4.1 Power-up ..........................................................................................19
4.2 LED Status Monitors......................................................................... 19
Power (Green) ....................................................................... 20
Line Link (Green) (C1 and C2 ports)...................................... 20
ETH Link (Green)................................................................... 20
5. Software Upgrade...................................................................................... 20
A. Specifications............................................................................................. 21
A.1 Line Rate ..........................................................................................21
A.2 Ethernet Interface .............................................................................21
A.3 Status LEDs ......................................................................................21
Power (Green) ....................................................................... 21
Line Link (Green) (C1 and C2 ports)...................................... 21
ETH Link (Green)................................................................... 21
A.4 Configuration ....................................................................................21
A.5 Power and Power Supply Specifications ..........................................21
A.6 Transmission Line .............................................................................22
A.7 Line Coding .......................................................................................22
A.8 Line Interface ....................................................................................22
A.9 Physical Connection .........................................................................22
A.10 Environment ...................................................................................... 22
A.11 Third Party Software Licenses ..........................................................23
Page 3
724-746-5500 | blackbox.com
Page 3
B. Interface Pinouts........................................................................................ 23
B.1 Line Port (C1, C2) .............................................................................23
B.2 Ethernet Port ....................................................................................23
Page 4
724-746-5500 | blackbox.com
Black Box Ethernet Extenders
RADIO FREQUENCY INTERFERENCE STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Sub p art B of Part 15 of FCC rules, whi ch ar e de si gne d to pr ovi de rea
­sonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compli­ance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règle
-
ment sur le brouillage radioélectrique publié par Industrie Canada.
Page 5
724-746-5500 | blackbox.com
Page 5
INSTRUCCIONES DE SEGURIDAD
(Normas Oficiales Mexicanas Electrical Safety Statement)
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para refer­encia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instru cciones de oper­ación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctric o n o deb erá s er us ado c erc a del ag ua —por ej em plo , c erc a de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las in strucc iones de op eració n. Todo otro servicio de berá s er refer
-
ido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera q ue s u p os ici ón no i nte rfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléc trico d eber se r situado fuer a del a lcance d e fuente s de c alor c omo radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificado
-
res) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo par
-
ticular atención a los contactos y receptáculos donde salen del aparato.
Page 6
724-746-5500 | blackbox.com
Black Box Ethernet Extenders
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomenda­ciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuida do deb e s er tom ado de tal manera qu e o bje cto s liq uidos no sean de rram a­dos sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A. El cable de poder o el contacto ha sido dañado; u B. Objectos han caído o líquido ha sido derramado dentro del aparato; o C. El aparato ha sido expuesto a la lluvia; o D. El aparato pa rece no operar no rmalm ente o m uest ra un ca mbio e n su de sem-
peño; o
E. El aparato ha sido tirado o su cubierta ha sido dañada.
Page 7
724-746-5500 | blackbox.com
Page 7
SAFETY WHEN WORKING WITH ELECTRICITY
This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
Do not open the device when the power cord is con­nected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
For devices with an external power adapter, the power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compli­ance with local regulatory requirements.
For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.
For DC powered dev ices, ensur e that the inte rconnecting cables are rated for pr oper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
WAN, LAN & PSTN ports (connections) may have hazard­ous volt ag es present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous network volt­ages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
Do not work on the device or connect or disconnect cables during periods of lightning activity.
WARNIN
G
Page 8
724-746-5500 | blackbox.com
Black Box Ethernet Extenders
In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa rate this prod uct from othe r waste and scrap and deliver to the WEEE col­lection system in your country for recycling.
This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electroni c printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the following to pre­vent ESD:
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensur­ing that it makes good sk in c ontact. Connect the clip to an unpainted surface of the chas­sis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must oper­ate effectively. If no wrist strap is available, ground yourself by touching th e metal p art of the chassis.
W
ARNIN
G
W
ARNIN
G
W
ARNIN
G
Page 9
724-746-5500 | blackbox.com
Page 9
1. GENERAL INFORMATION
Thank you for your purchase of this Black Box product. This product has been thor­oughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Black Box Technical Support at 724-746-5500 or info@Black Box.com.
1.1 FEATURES
• High speed extension with speeds up to 5.696 Mbps
• Two 2-wire line connections via built-in RJ-45 ports (C1 and C2)
• Four auto 10- or 100Base-T and full or half-duplex Ethernet ports for direct con­nection of four Ethernet devices
• Extends Ethernet up to 3.4 m iles (5 .48 k m) u sing 24 AWG/0.5mm wire (192 kbp s speed) per hop
• DIN Rail mount
• -40 to 85ºC operating temperature
1.2 DESCRIPTION
The Black Box LB532A-M Multi-Drop Ethernet Extenders are easy to use and take advantage of existing copper twisted-pair infrastructure to connect Ethernet networks or devices at high speeds over long distances. Operating over standard 0.5 mm voice­grade wiring, the LB532A-M delivers speeds up to 5.7 Mbps and extends Ethernet connections across distances ranging from 11,000 ft (2.2 miles or 3.5 km) to 18,000 ft (3.4 miles or 5.4 8 k m) per ho p. Whether you need co nne ct to a re mo te offices, kiosks , guard stations, train stations, digital sensors or IP cameras— Blac k Box Ethernet Extenders offer the industry’s optimum combination of speed and distance. Black Box Ethernet Extenders ensure hassle-free set-up and operation, while achieving the high
­est possible line rate for the required dista nce and el ec tro-m ag neti c en vi ronm en t. The LB532A-M temperature specs allow for operation at -40 to 85ºC.
1.3 POWER INPUT CONNECTOR
The LB532A-M comes with an external AC universal power supply. (For additional specifications and details on power and power supply, see
Appendix A.5 on page 21.)
• The power connection to the LB532A-M is a terminal block
• Rated voltage: 5 VDC
Page 10
724-746-5500 | blackbox.com
Page 10
Black Box Ethernet Extenders
• Rated current: 1 A DC
Figure 1. Terminal block power connection
• Output from power supply: 5 VDC, 1A regulated (± 5%)
• Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
2. CONFIGURATION
You can configure the LB532A-M only through the hardware configuration via DIP
switches.
2.1 HARDWARE (DIP-SWITCH) CONFIGURATION
The only configurable parameter is the data rate, set by DIP switches S4-2 through S4-8 (see
Table 2 on page 11). All other DIP switches should remain in the OFF posi­tion. When configuring the data rate, set the DIP switches to the desired rate before applying power to the LB532A-M.
NOTE: Factory Default Configuration: 5.696 Mbps (DIP switches are all OFF)
NOTE: The default configuration for the LB532A-M is 89 timeslots (5695 kbps).
The external AC adapter shall be a lis ted limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator . Ens ure that the AC pow er cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet that has earth
ground.
Table 1: LB532A-M configurable parameters
Parameter Description
Possible
Values
Data Rate/ Timeslots
Defines the number of timeslots. The data rate is calculated by the equation:
data rate = timeslots x 64k.
1-72 timeslots
Power
+ -
CAUTIO
N
Page 11
724-746-5500 | blackbox.com
Page 11
Configuration
Figure 2. Underside of LB532A-M showing location of DIP switches
DIP switches S1 and S3 must all be in the OFF position. DIP switch S4, positions 2–8 are us ed to configure the data ra te. Th is figu re s hows the DIP switch orientation with respect to ON and OFF positions is consistent for all
switches.
2.2 DIP SWITCH SETTINGS
Once the device is powered up and operating in DIP switch configuration mode, you cannot change configuration until you power it down again.
DIP Switch Settings: Data Rate
Switches S4-2 through S4-8 define the line rate.
Table 2: S4-2 throught S4-8 Data Rate DIP switch settings
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
OFF OFF OFF OFF OFF OFF ON 192 OFF OFF OFF OFF OFF ON OFF 256 OFF OFF OFF OFF OFF ON ON 320 OFF OFF OFF OFF ON OFF OFF 384 OFF OFF OFF OFF ON OFF ON 448 OFF OFF OFF OFF ON ON OFF 512 OFF OFF OFF OFF ON ON ON 576 OFF OFF OFF ON OFF OFF OFF 640 OFF OFF OFF ON OFF OFF ON 704 OFF OFF OFF ON OFF ON OFF 768
OFF
ON
1 2 3 4 5 6 7 8
ON
Page 12
724-746-5500 | blackbox.com
Page 12
Black Box Ethernet Extenders
OFF OFF OFF ON OFF ON ON 832 OFF OFF OFF ON ON OFF OFF 896 OFF OFF OFF ON ON OFF ON 960 OFF OFF OFF ON ON ON OFF 1024 OFF OFF OFF ON ON ON ON 1088 OFF OFF ON OFF OFF OFF OFF 1152 OFF OFF ON OFF OFF OFF ON 1216 OFF OFF ON OFF OFF ON OFF 1280 OFF OFF ON OFF OFF ON ON 1344 OFF OFF ON OFF ON OFF OFF 1408 OFF OFF ON OFF ON OFF ON 1472 OFF OFF ON OFF ON ON OFF 1536 OFF OFF ON OFF ON ON ON 1600 OFF OFF ON ON OFF OFF OFF 1664 OFF OFF ON ON OFF OFF ON 1728 OFF OFF ON ON OFF ON OFF 1792 OFF OFF ON ON OFF ON ON 1856 OFF OFF ON ON ON OFF OFF 1920 OFF OFF ON ON ON OFF ON 1984 OFF OFF ON ON ON ON OFF 2048 OFF OFF ON ON ON ON ON 2112 OFF ON OFF OFF OFF OFF OFF 2176 OFF ON OFF OFF OFF OFF ON 2240 OFF ON OFF OFF OFF ON OFF 2304 OFF ON OFF OFF OFF ON ON 2368 OFF ON OFF OFF ON OFF OFF 2432 OFF ON OFF OFF ON OFF ON 2496 OFF ON OFF OFF ON ON OFF 2560 OFF ON OFF OFF ON ON ON 2624 OFF ON OFF ON OFF OFF OFF 2688 OFF ON OFF ON OFF OFF ON 2752 OFF ON OFF ON OFF ON OFF 2816 OFF ON OFF ON OFF ON ON 2880 OFF ON OFF ON ON OFF OFF 2944 OFF ON OFF ON ON OFF ON 3008
Table 2: S4-2 throught S4-8 Data Rate DIP switch settings
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
Page 13
724-746-5500 | blackbox.com
Page 13
Configuration
OFF ON OFF ON ON ON OFF 3072 OFF ON OFF ON ON ON ON 3136 OFF ON ON OFF OFF OFF OFF 3200 OFF ON ON OFF OFF OFF ON 3264 OFF ON ON OFF OFF ON OFF 3328 OFF ON ON OFF OFF ON ON 3392 OFF ON ON OFF ON OFF OFF 3456 OFF ON ON OFF ON OFF ON 3520 OFF ON ON OFF ON ON OFF 3584 OFF ON ON OFF ON ON ON 3648 OFF ON ON ON OFF OFF OFF 3712 OFF ON ON ON OFF OFF ON 3776 OFF ON ON ON OFF ON OFF 3840 OFF ON ON ON OFF ON ON 3904 OFF ON ON ON ON OFF OFF 3968 OFF ON ON ON ON OFF ON 4032 OFF ON ON ON ON ON OFF 4096 OFF ON ON ON ON ON ON 4160
ON OFF OFF OFF OFF OFF OFF 4224 ON OFF OFF OFF OFF OFF ON 4288 ON OFF OFF OFF OFF ON OFF 4352 ON OFF OFF OFF OFF ON ON 4416 ON OFF OFF OFF ON OFF OFF 4480 ON OFF OFF OFF ON OFF ON 4544 ON OFF OFF OFF ON ON OFF 4608 ON OFF OFF OFF ON ON ON 4672 ON OFF OFF ON OFF OFF OFF 4736 ON OFF OFF ON OFF OFF ON 4800 ON OFF OFF ON OFF ON OFF 4864 ON OFF OFF ON OFF ON ON 4928 ON OFF OFF ON ON OFF OFF 4992 ON OFF OFF ON ON OFF ON 5056 ON OFF OFF ON ON ON OFF 5120 ON OFF OFF ON ON ON ON 5184
Table 2: S4-2 throught S4-8 Data Rate DIP switch settings
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
Page 14
724-746-5500 | blackbox.com
Page 14
Black Box Ethernet Extenders
Ethernet Management Port
The LB532A-M offers a 10/100 Ethernet port to view the current DIP switch settings via Telnet sessions. The Ethernet interface default IP address is 192.168.200.1. Log into the LB532A-M management port using the password superuser.
Through the Ethernet management port, the following variables can be configured or
monitored:
status: Shows the general configuration and status of the unit
info: Shows system information
upgrade: Enables the system upgrade prompt
Line Status Command. The status command shows the following line status informa­tion: sync st ate , lin k s t ate , lin k s pee d, erro r cou nte rs, line condition, noi se marg in, and test mode status.
The following status information is available through the Command Line Interface:
sync state: Out of Sync, Acquiring Sync, In Sync, or Losing Sync
link state: In Progress, Success, Deactivated, or Idle
NOTE: Link S tate vs. Sync S tate—The Link State describes whether the line is train­ing (in progress), linked (success), deactivated (we don’t have an option to deactivate the modem, so the user should not see this), or idle.
NOTE: The Sync State describes whether no sync words have been found (out of sync), there are no sync w ord errors (in sy nc ), o r whether we are transitioning from out of sync to in sy nc (acqui ring sync) or vi ce vers a (losin g sync) . Typically, when the li nk is training, the sync state goes from out of sync to acquiring sync to in sync.
ON OFF ON OFF OFF OFF OFF 5248 ON OFF ON OFF OFF OFF ON 5312 ON OFF ON OFF OFF ON OFF 5376 ON OFF ON OFF OFF ON ON 5440 ON OFF ON OFF ON OFF OFF 5504 ON OFF ON OFF ON OFF ON 5568 ON OFF ON OFF ON ON OFF 5632 ON OFF ON OFF ON ON ON 5696
Table 2: S4-2 throught S4-8 Data Rate DIP switch settings
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
Page 15
724-746-5500 | blackbox.com
Page 15
Configuration
actual rate: The actual rate at which the link is running (minus overhead).
noise margin: Th e max imum tol erable increa se in e xterna l nois e power th at stil l allows for BER of less than 1x 10–7.
error counters: The following error counters are available: CRC and LOSW (Loss of Sync Word)
Help Commands. The following commands are provided to help the user find the cor­rect command:
help: Lists all the commands that the console recognizes
Example Command Line Interface Session.
LB532A-M Command Shell Password: LB532A-M> status c1: configuration:
link mode: remote link rate: 5696 line probe: disabled
status:
actual rate: 0 loss of signal: unavailable noise margin: 0 snr: 0 sync state: out of sync link state: idle power scale: 0dB
error counters:
crc: 0 losw: 0
c2:
configuration:
link mode: local link rate: 5696 line probe: disabled
status:
actual rate: 0 loss of signal: unavailable noise margin: 0 snr: 0 sync state: out of sync link state: idle power scale: 0dB
Page 16
724-746-5500 | blackbox.com
Page 16
Black Box Ethernet Extenders
error counters:
crc: 0 losw: 0
LB532A-M> exit
NOTE: The line probe feature is a future product enhancement.
3. INSTALLATION
Once the LB532A-M is properly configured, it is ready to connect to the line interface and to the power source. This section explains how to make these connections.
Figure 3. LB532A-M front panel connectors
3.1 CONNECTING THE INTERFACE
The LB532A-M supports communication between two DTE devices using 24 AWG (0.5
mm) wire up to:
• 18,000 feet (3.4 miles or 5.48 km) at 192 kbps per hop
• 11,000 feet (2.2 miles or 3.5 km) at 5696 kbps per hop
Two things are essential:
1. These units work in pairs with any LB532A-L, LB532A-R, LB512A-L or LB512A­R model. Every local line port should connect to a remote line port.
Page 17
724-746-5500 | blackbox.com
Page 17
Installation
Figure 4. Local to remote connection
2. To function properly, the LB532A-M needs one twisted pair of metallic wire. This twisted pair must be unconditioned, dry, metallic wire, between 19 (0.9mm) and 26 AWG (0.4mm) (the higher number gauges will limit distance). Standard dial­up telephone circuits, or leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable.
The RJ-45 line connector on the LB532A-M’s twisted pair interface is polarity insensi­tive and is wired for a two-wire interface.
3.2 CONNECTING THE ETHERNET INTERFACE
This section describes how to connect the Ethernet ports to your network equipment.
The RJ-4 5 ports labeled E thernet are the Auto-MDIX 10/100Base-T interface. These ports are designed to connect directly to a 10/100Base-T device or network. You may connect these ports to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, cur­rent, anticipated temperature, flammability, and mechanical serviceability.
CAUTIO
N
Page 18
724-746-5500 | blackbox.com
Page 18
Black Box Ethernet Extenders
3.3 CONNECTING EXTERNAL AC UNIVERSAL POWER SUPPLY
The LB532A-M is equipped with the terminal block power connection already on the unit (see
Figure 5). For addtional information only, see Figure 6 for details on how to
install the power supply.
Figure 5. LB532A-M bottom panel power connector
Figure 6. Power supply installation
To connect the AC power sup ply, determine the positi ve le ad and negative l ead on the power adapter. Insert the positive lead into the openin g on th e termi nal bl ock l abeled + and the negative lead into the opening on the terminal block labeled -. Tighten the screws on the block to secure the wires. The LB532A-M powers up as soon as it is connected to an AC power source—there is no power switch.
Page 19
724-746-5500 | blackbox.com
Page 19
Operation
4. OPERATION
Once the LB532A-M is properly configured and installed, it should operate transpar­ently. The fol lowi ng se ctions describe po w er-up , reading the LED s tatus monitors, and using the built-in loopback test modes.
4.1 POWER-UP
To apply power to the LB532A-M, first be sure that you have read section 1.3, “Power Input Connector” on page 9, and that the unit is connected to the appropriate power source. Power up the unit.
4.2 LED STATUS MONITORS
There are four LED s th at p rov id e feedback on th e s t at e of the unit. Fig ure 7 shows the location of the front panel LEDs.
Figure 7. LB532A-M front panel LEDs
The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator . Ens ure that the AC pow er cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet that has earth ground.
CAUTIO
N
Page 20
724-746-5500 | blackbox.com
Page 20
Black Box Ethernet Extenders
Power (Green)
The Power LED glows solid during normal operation. At startup, during the POST, the LED blinks on ce ev ery s ec ond . If th e PO ST fai ls , th e u ni t do es no t e nte r no rma l ope ra
-
tion, and the LED blinks once every 0.4 seconds.
Line Link (Green) (C1 and C2 ports)
On both C1 and C2 ports, the Line LED glows solid while a link is established. While the link is training, it blinks once every second.
ETH Link (Green)
The Ethernet Link LEDs show that there is an active phy s ical connection to the con­sole, or an active physical connection to an Ethernet device.
5. SOFTWARE UPGRADE
The software upgrade feature is available through TFTP. The software upgrade takes approximately 1 to 2 minutes to complete. To upgrade the software:
1. Connect to the LB532A-M via the Ethernet management port and a Telnet ses­sion at 192.168.200.1.
2. Enter the upgrade <TFTP server IP address>:/<filename> command to begin the upgrade.
After approximately 1 to 2 minutes, the LB532A-M will operate with the upgraded
software.
Page 21
724-746-5500 | blackbox.com
Page 21
Software Upgrade
A. SPECIFICATIONS
A.1 LINE RATE
192 to 5696 kbps (64k increments; 3-89 timeslots)
A.2 ETHERNET INTERFACE
Four RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
A.3 STATUS LEDS
Power (Green)
The Power LED glows solid during normal operation. At startup, during the POST, the LED blinks on ce ev ery s ec ond . If th e PO ST fai ls , th e u ni t do es no t e nte r no rma l ope ra
-
tion, and the LED blinks once every 0.4 seconds.
Line Link (Green) (C1 and C2 ports)
On both C1 and C2 ports, the Line LED glows solid while a link is established. While the link is training, it blinks once every second.
ETH Link (Green)
The Ethe rnet Link LEDs show that there is an active physical network connection to the Cons ole or an Ethernet device.
A.4 CONFIGURATION
Configuration is done only with externally accessible DIP switches.
NOTE: Factory Default Configuration: 5.696 Mbps (DIP switches are all OFF)
A.5 POWER AND POWER SUPPLY SPECIFICATIONS
The LB532A-M comes with an external universal AC power supply.
• The power connection to the LB532A-M is a terminal block (see Figure 8 on page 22)
• There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.
• Rated voltage: 5 VDC
Page 22
724-746-5500 | blackbox.com
Page 22
Black Box Ethernet Extenders
• Rated current: 1 A DC
Figure 8. Terminal block power connection
• Output from power supply: 5 VDC, 1A, regulated (± 5%)
• Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
A.6 TRANSMISSION LINE
Single Twisted Pair
A.7 LINE CODING
TC-PAM (Trellis Coded Pulse Amplitude Modulation)
A.8 LINE INTERFACE
Transformer coupled, 2500 Vrms isola tion
A.9 PHYSICAL CONNECTION
Two RJ-45 ports, 2-wire polarity insensitive pins 4 and 5
A.10 ENVIRONMENT
Operating temp: -40 to 185°F (-40 to 85°C) Relative Humidity: 8 to 90% non-condensing Altitude: 0 to 15,000 feet (0 to 4,600 meters)
The external AC adapter shall be a lis ted limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator . Ens ure that the AC pow er cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet that has earth ground.
Power
+ -
CAUTIO
N
Page 23
724-746-5500 | blackbox.com
Page 23
Specifications
A.11 THIRD PARTY SOFTWARE LICENSES
NOTE: The LB532A-M include s software developed under third party licenses.
B. INTERFACE PINOUTS
B.1 LINE PORT (C1, C2)
NOTE: N/C is “no connection.” Although denoted as Tip and Ring, the line ports are not polarity sensitive.
B.2 ETHERNET PORT
NOTE: Pins not listed are not used.
Table 3: RJ-45 connector
Pin Signal
1N/C 2N/C 3N/C 4Tip 5Ring 6N/C 7N/C 8N/C
Table 4: RJ-45 socket 10/100Base-T
Pin Signal
1TX+ 2TX­3RX+ 6RX-
Page 24
LB532A-M version 1
Loading...