Black Box ISU2011-8-EURO, ISU2011-4-EURO, ISU2011-4-UK, ISU2011-8-UK User Manual

4-Port BRI-Hub (UK): ISU2011-4-UK
4-Port BRI-Hub (Euro): ISU2011-4-EURO
8-Port BRI-Hub (UK): ISU2011-8-UK
8-Port BRI-Hub (Euro): ISU2011-8-EURO
BRI-Hub
TECHNICAL:
SALES:
FAX:
ADDRESS:
WEB:
BRI-Hub
How To Contact your Local Black Box
Italy: Australia:
Black Box Italia S.P.A Black Box Catalog Australia PTY LTD Tel: 0227400280 Tel: 0398797100 Fax: 0227400219 Fax: 0398702955 Web Site: www.blackbox.it
Deutschland: Brazil:
Black Box Deutschland Black Box Do Brasil. Tel: 0811/5541-0 Tel: (011) 5515-4000 Fax: 0811/5541-499 Fax: (011) 5515-4002 Web Site: www.blackbox-deutschland.com Web Site: www.blackbox.com.br
Switzerland: Canada:
Datacom Black Box Services AG Black Box Canada Corp. Tel: 0554517070 Tel: 0416-736-8000 Fax: 0554517075 Fax: 0416-736-7348 Web Site: www.black-box.ch Web Site: www.blackbox.com
Netherlands: Mexico:
Black Box Datacom BV Black Box De Mexico S.A. de C.V Tel: 03032417799 Tel: 05-420-0100 Fax: 0302414746 Fax: 05-420-0123 Web Site: www.blackbox.nl/ Web Site: www.blackbox.com.mx
Belgium: Japan:
Black Box Black Box Catalog Tel: 027258550 Tel: 03-3820-5011 Fax: 027259212 Fax: 03-3820-5010 Web Site: www.blackbox.be Web Site: www.blackbox.co.jp/
France: U.S.A
Black Box Catalogue Black Box Corporation Tel: 0145606700 Tel: 724-746-5500 Fax: 0145606747 Fax: 724-746-0746 Web Site: www.blackbox.fr Web Site: www.blackbox.com
Spain: Chile
Black Box Comunicaciones S.A. Black Box Chile Tel: 34 91 663 0200 Tel: 00 562 223 8811 Fax: 34 91 661 84 35 Fax: 00 562 225 1002 Web Site: www.blackbox.es Web Site: www.Blackbox.cl
SALES: 0118 965 5100
2
BRI-Hub
Contents
Introduction............................................................................................................................... 4
Description of functions................................................................................................ 4
Options.......................................................................................................................... 5
BRI-Hub............................................................................................................ 5
BRI-Hub S......................................................................................................... 5
Technical Specifications ........................................................................................................... 6
SO Interface BRI........................................................................................................... 6
Common Features ......................................................................................................... 6
Power supply................................................................................................................. 6
Power Supply ................................................................................................................ 7
Sound Emission............................................................................................................. 7
S0-Interface............................................................................................................................... 6
Parts List.................................................................................................................................... 7
Installation................................................................................................................................. 8
Tabletop......................................................................................................................... 8
Wall mount.................................................................................................................... 8
Rack Mount................................................................................................................... 8
Power Supply ............................................................................................................................ 9
BRI-Hub........................................................................................................................ 9
BRI-Hub-S .................................................................................................................... 9
Connecting the Hub................................................................................................................. 10
Power Failure Operation ............................................................................................. 11
Termination Resistors ..................................................................................... 13
Operation................................................................................................................................. 14
Displays and Controls ................................................................................................. 14
Displays........................................................................................................... 14
Controls........................................................................................................... 14
Maintenance............................................................................................................................ 14
Cleaning ...................................................................................................................... 14
Troubleshooting ...................................................................................................................... 15
TECHNICAL: 0118 931 2233
3
BRI-Hub
Introduction
Within the data communications and LAN industry it is well known that a structured cabling concept using a star topology has significant advantages, such easier maintenance, unproblematic changes in the configuration and faster fault finding. Last but not least, a structured cabling concept may be used for all kinds of LAN-, WAN and telecommunications technologies.
Nevertheless, with ISDN a bus has to be formed to connect several users to one Basic Rate Interface (BRI), but a bus cannot be formed with a star topology. Alternatively a complete BRI must be dedicated to one user (point to point configuration), which is in many cases not feasible or too expensive.
By using the active star BRI-Hub it is now possible to use the struct ured star-cabling concept for ISDN. In addition the distance between the NT and the TEs may be extended because of the use of point-to-point links between the BRI-Hub and the TEs. It is also possible to use the "extended passive bus configuration" (distance up to 1000m) if all connections to the TEs are in the same range of distance (+/- 50m).
The Phantom Feed unit can be used with the BRI-Hub to provide power to all 4 or 8 ports on the BRI-Hub.
Description of functions
The BRI-Hub converts the ISDN BRI bus structure to a set of point-to-point connections, which are connected within the BRI-Hub to form a 'logical bus'. At this, the BRI-Hub makes it possible to hook up ISDN terminals via a maximum of 8 lines with the maximum length of 150 m each. Up to 1000 m is possible in a special configuration. Every port forms a separate electrical segment. Through this wiring faults don't affect other segments.
4
SALES: 0118 965 5100
BRI-Hub
If a BRI needs to be made available in several rooms, it used to be necessary to install a bus from the server room through all rooms. (See picture ‘old’). Now star wiring can be used with BRI-Hub, which comes to use also for telephone and local area networks (see picture 'with BRI-Hub').
Options
BRI-Hub
This option derives its power from the power supply provided.
BRI-Hub S
This option derives power from the S-Bus and uses an internal DC-DC converter to adapt the voltage to power itself – no external power supply is required. This option is available as a special request from Black Box.
Both of the above options can be used in conjunction with the Phantom Feed, a device used to provide power on each of the hub’s S interfaces.
TECHNICAL: 0118 931 2233
5
Loading...
+ 11 hidden pages